期刊文献+
共找到18,118篇文章
< 1 2 250 >
每页显示 20 50 100
Drilling-based measuring method for the c-φ parameter of rock and its field application 被引量:1
1
作者 Bei Jiang Fenglin Ma +5 位作者 Qi Wang Hongke Gao Dahu Zhai Yusong Deng Chuanjie Xu Liangdi Yao 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第1期65-76,共12页
The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(R... The technology of drilling tests makes it possible to obtain the strength parameter of rock accurately in situ. In this paper, a new rock cutting analysis model that considers the influence of the rock crushing zone(RCZ) is built. The formula for an ultimate cutting force is established based on the limit equilibrium principle. The relationship between digital drilling parameters(DDP) and the c-φ parameter(DDP-cφ formula, where c refers to the cohesion and φ refers to the internal friction angle) is derived, and the response of drilling parameters and cutting ratio to the strength parameters is analyzed. The drillingbased measuring method for the c-φ parameter of rock is constructed. The laboratory verification test is then completed, and the difference in results between the drilling test and the compression test is less than 6%. On this basis, in-situ rock drilling tests in a traffic tunnel and a coal mine roadway are carried out, and the strength parameters of the surrounding rock are effectively tested. The average difference ratio of the results is less than 11%, which verifies the effectiveness of the proposed method for obtaining the strength parameters based on digital drilling. This study provides methodological support for field testing of rock strength parameters. 展开更多
关键词 Digital drilling Rock crushing zone c-u parameter measurement method Field application
下载PDF
A LASER-SCANNING NON-CONTACT MEASURING METHOD FOR ROUNDNESS ERRORS 被引量:1
2
作者 宋甲午 张国玉 +3 位作者 安志勇 李成志 景红薇 高玉军 《兵工学报》 EI CAS CSCD 北大核心 2000年第1期-,共3页
利用激光狭缝扫描原理和光电传感技术,提出了一种用于测量大型回转体类零件圆度误差的激光扫描非接触测量方法和测量系统。本文详细论述了测量系统及其测量原理、工件安装偏心误差的分离技术和计算机实时数据处理系统,实验结果证实了... 利用激光狭缝扫描原理和光电传感技术,提出了一种用于测量大型回转体类零件圆度误差的激光扫描非接触测量方法和测量系统。本文详细论述了测量系统及其测量原理、工件安装偏心误差的分离技术和计算机实时数据处理系统,实验结果证实了这种测量方法的可行性。 展开更多
关键词 圆度误差 激光狭缝扫描 非接触测量 偏心误差 A LASER-SCANNING non-contact measuring
下载PDF
CNC NON-CONTACT MEASURING SYSTEM FOR FREEFORM SURFACE 被引量:3
3
作者 JuHua Wang Wen Chen Zichen Li Jian Wang Hengkui Institute of Production Engineering, Zhejiang University, Hangzhou 310027, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第2期103-106,共4页
Developing CNC measuring method on the base of coordinate machine can make the best of the hardware resource of CNC system and realize the integration of CAD/CAM/CAT. Based on the evenly spaced parallel planes scannin... Developing CNC measuring method on the base of coordinate machine can make the best of the hardware resource of CNC system and realize the integration of CAD/CAM/CAT. Based on the evenly spaced parallel planes scanning, a new adaptive digitizing approach for freeform surface namely arc length extrapolation is put forward. By this way, the digitizing approach can be added to the CNC system, while the system's hardware and software are not changed. 展开更多
关键词 REVERSE engineering Freeform surface DIGITALIZATION CNC non-contact measurement ARC EXTENSION
下载PDF
Application of the body of revolution finite-element method in a re-entrant cavity for fast and accurate dielectric parameter measurements
4
作者 冯天琦 余承勇 +1 位作者 李恩 石玉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期36-44,共9页
In dielectrometry,traditional analytical and numerical algorithms are difficultly employed in complex resonant cavities.For a special kind of structure(a rotating resonant cavity),the body of revolution finite-element... In dielectrometry,traditional analytical and numerical algorithms are difficultly employed in complex resonant cavities.For a special kind of structure(a rotating resonant cavity),the body of revolution finite-element method(BOR-FEM)is employed to calculate the resonant parameters and dielectric parameters.In this paper,several typical resonant structures are selected for analysis and verification.Compared with the resonance parameter values in the literature and the simulation results of commercial software,the error of the BOR-FEM calculation is less than 0.9%and a single solution time is less than 1 s.Reentrant coaxial resonant cavities loaded with dielectric materials are analyzed using this method and compared with simulation results,showing good agreement.Finally,in this paper,the established BOR-FEM method is successfully applied with a machined cavity for the accurate measurement of the complex dielectric constant of dielectric materials.The test specimens were machined from polytetrafluoroethylene,fused silica and Al_(2)O_(3),and the test results showed good agreement with the literature reference values. 展开更多
关键词 MICROWAVE resonance method dielectric measurement coaxial resonant cavity
下载PDF
A Content-Based Medical Image Retrieval Method Using Relative Difference-Based Similarity Measure
5
作者 Ali Ahmed Alaa Omran Almagrabi Omar MBarukab 《Intelligent Automation & Soft Computing》 SCIE 2023年第8期2355-2370,共16页
Content-based medical image retrieval(CBMIR)is a technique for retrieving medical images based on automatically derived image features.There are many applications of CBMIR,such as teaching,research,diagnosis and elect... Content-based medical image retrieval(CBMIR)is a technique for retrieving medical images based on automatically derived image features.There are many applications of CBMIR,such as teaching,research,diagnosis and electronic patient records.Several methods are applied to enhance the retrieval performance of CBMIR systems.Developing new and effective similarity measure and features fusion methods are two of the most powerful and effective strategies for improving these systems.This study proposes the relative difference-based similarity measure(RDBSM)for CBMIR.The new measure was first used in the similarity calculation stage for the CBMIR using an unweighted fusion method of traditional color and texture features.Furthermore,the study also proposes a weighted fusion method for medical image features extracted using pre-trained convolutional neural networks(CNNs)models.Our proposed RDBSM has outperformed the standard well-known similarity and distance measures using two popular medical image datasets,Kvasir and PH2,in terms of recall and precision retrieval measures.The effectiveness and quality of our proposed similarity measure are also proved using a significant test and statistical confidence bound. 展开更多
关键词 Medical image retrieval feature extraction similarity measure fusion method
下载PDF
Improved calibration method for displacement transformation coefficient in optical and visual measurements
6
作者 Haopeng Li Zurong Qiu 《Nanotechnology and Precision Engineering》 CAS CSCD 2023年第1期12-25,共14页
Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement trans... Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement transformation coefficient(DTC)of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process,and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view(FFOV).To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands,a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV.First,an image coordinate system,a pixel measurement coordinate system,and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM.In addition,marker spots in the FFOV are selected,and the DTCs at the marker spots are obtained from calibration experiments.Also,a fitting method based on locally weighted scatterplot smoothing(LOWESS)is selected,and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots.Finally,the calibrated distribution functions of the DTCs are applied to the LVDMM,and experiments conducted to verify the displacement measurement accuracies are reported.The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than±15μm and±19μm,respectively,and that for oblique displacement is better than±24μm.Compared with the traditional calibration method,the displacement measurement error in the FFOV is now 90%smaller.This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV,and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated. 展开更多
关键词 Displacement transformation coefficient(DTC) Laser and vision-based displacement measuring module(LVDMM) Displacement measurement Locally weighted scatterplot smoothing(LOWESS) Calibration method
下载PDF
THE STUDY ON MEASURING TECHNIQUE OF PARTIAL DISCHARGE IN GAS INSULATED SWITCHGEAR USING ULTRA HIGH FREQUENCY METHOD WITH EXTERNAL SENSORS 被引量:1
7
作者 李忠 冯允平 《Journal of Pharmaceutical Analysis》 SCIE CAS 2005年第2期7-10,15,共5页
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ... Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn’t limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals’ amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique. 展开更多
关键词 gas insulated switchgear partial discharge ultra high frequency finite-difference time-domain (FDTD) method measurEMENT external sensor
下载PDF
The Method for Measuring the Loop Resistance and the Temperature Rise Calculation of GIS Conductor Pole 被引量:1
8
作者 Li Zhou Tiecheng Lu Bo Zhang 《Journal of Power and Energy Engineering》 2015年第4期306-312,共7页
This paper studies the method for measuring the loop resistance of GIS conductor pole based on the super capacitor producing impulse current up to several thousand amperes. This method overcomes the limitations of con... This paper studies the method for measuring the loop resistance of GIS conductor pole based on the super capacitor producing impulse current up to several thousand amperes. This method overcomes the limitations of conventional diagnostic method. Typical GIS conductor poles are chosen. Based on FEA and lab tests, the effect of different forms of current and contact condition, relationship between the temperature of contact and the loop resistance is researched. In full- scale testing under realistic operating conditions on the new 220 kV GIS using prototype instrumentation a very good sensitivity in an early stage was obtained. 展开更多
关键词 The method for measuring the Loop Resistance and the Temperature RISE CALCULATION of GIS Conductor POLE
下载PDF
A Rapid Method for Measuring Seed Protein Content in Cowpea (<i>Vigna unguiculata</i>(L.) Walp) 被引量:1
9
作者 Yuejin Weng Ainong Shi +5 位作者 Waltram Second Ravelombola Wei Yang Jun Qin Dennis Motes David Octor Moseley Pengyin Chen 《American Journal of Plant Sciences》 2017年第10期2387-2396,共10页
Cowpea (Vigna unguiculata (L.) Walp), a legume crop that is grown in the worldwide, provides beneficial proteins for human consumption and animal feeding. In comparison, Rapid N analyzer as traditional method, has bee... Cowpea (Vigna unguiculata (L.) Walp), a legume crop that is grown in the worldwide, provides beneficial proteins for human consumption and animal feeding. In comparison, Rapid N analyzer as traditional method, has been widely used to measure protein content through the percentage of total nitrogen in the seed’s grounded powder. Near-Infrared Reflectance (NIR) has commonly been used to measure protein content in soybean seeds using whole grain without the need of seed grinding, which makes it possible to obtain fast results at a lower cost-per-analysis than the traditional combustion method. The specific objective of this study is to test a rapid method for measuring cowpea seed protein content by the NIR analyzer comparing to the traditional rapid N analyzer. A total of 240 cowpea genotypes were used in this study, including six seed coat colors, black, blackeye, browneye, cream, pinkeye, and red with 40 cowpea genotypes. The results showed that a linear relationship exists between the NIR analyzer and the Rapid N analyzer in the six different color groups. The correlation efficiency (r) between the seed protein contents from NIR and Rapid N was higher for pinkeye seed (r = 0.867), blackeye (0.771), cream (0.729), browneye (0.700), and red (0.623), respectively, but lower for black seeds, indicating that the NIR analyzer can be used to measure protein content for cowpea seeds with the five types of seed coat except black. Overview, the cowpea seed protein content measured from the NIR analyzer showed a little higher seed protein content. A series of regression models with different seed coat color have been built to adjust to protein content of colorful cowpea seeds from the NIR analyzer. But, it is not recommended to use for black color seeds due to a very low correlation efficiency (r) value with 0.184. 展开更多
关键词 COWPEA Seed PROTEIN CONTENT PROTEIN measurement method Rapid N ANALYZER Near-Infrared Reflectance (NIR) Vigna unguiculata
下载PDF
Arc Extraction Analysis for Circularity Measurement of Small Cylindrical Parts by the Segmenting-stitching Method
10
作者 ZHAO Jiali WU Dan +2 位作者 ZHANG Liang SHEN Bobo LI Qiaolin 《Instrumentation》 2023年第3期1-11,共11页
To reduce the stitching error of circularity measurement of small cylindrical workpieces(Diameter less than 3 mm)by the segmenting-stitching method,arc contour extraction is analyzed in this paper.The coordinates of c... To reduce the stitching error of circularity measurement of small cylindrical workpieces(Diameter less than 3 mm)by the segmenting-stitching method,arc contour extraction is analyzed in this paper.The coordinates of cross-sectional circle of a small cylindrical part are segmented into several equal arcs to be obtained by a two-dimensional coordinate measuring machine.The circularity contour of the small cylindrical part can be formed by stitching a series of arc contours which are calculated by the obtained arc coordinate data.Due to the different measuring pressure angles of different measuring positions,the accuracy of obtained arc coordinate points is different.The bigger the pressure angle is,the accurate the obtained arc coordinate data are.The experiments show that the accuracy of two ends of the arc data is not as good as the central part.Therefore,the two ends of the obtained arc data are appropriately to be cut off,namely,only the central part of the arc data are extracted to be used for the stitching.As a result,the mean value of the matching coefficient is enhanced by 12%,the deviation between the overlap part of the neighbouring arc contour is reduced by 26%,and the average curvature of the arc contours is improved with the extraction method.Thus,the accuracy of the stitched circularity contour can be improved by this extraction procedure in the segmenting-stitching method for the circularity measurement of the small cylindrical parts. 展开更多
关键词 Circularity measurement Arc Extraction Small Cylindrical Workpiece Segmenting-stitching method
下载PDF
Self-heating Probe Instrument and Method for Measuring High Temperature Melting Volume Change Rate of Material 被引量:2
11
作者 WANG Junwei WANG Zhiping +1 位作者 LU Yang CHENG Bo 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第2期371-376,共6页
The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics ... The castings defects are affected by the melting volume change rate of material. The change rate has an important effect on running safety of the high temperature thermal storage chamber, too. But the characteristics of existing measuring installations are complex structure, troublesome operation and low precision. In order to measure the melting volume change rate of material accurately and conveniently, a self-designed measuring instrument, self-heating probe instrument, and measuring method are described. Temperature in heating cavity is controlled by PID temperature controller; melting volume change rate υ and molten density are calculated based on the melt volume which is measured by the instrument. Positive and negative υ represent expansion and shrinkage of the sample volume after melting, respectively. Taking eutectic LiF+CaF2 for example, its melting volume change rate and melting density at 1 123 K are -20.6% and 2 651 kg/m-3 measured by this instrument, which is only 0.71% smaller than literature value. Density and melting volume change rate of industry pure aluminum at 973 K and analysis pure NaCl at 1 123 K are detected by the instrument too. The measure results are agreed with report values. Measuring error sources are analyzed and several improving measures are proposed. In theory, the measuring errors of the change rate and molten density which are measured by the self-designed instrument is nearly 1/20-1/50 of that measured by the refitted mandril thermal expansion instrument. The self-designed instrument and method have the advantages of simple structure, being easy to operate, extensive applicability for material, relatively high accuracy, and most importantly, temperature and sample vapor pressure have little effect on the measurement accuracy. The presented instrument and method solve the problems of complicated structure and procedures, and large measuring errors for the samples with high vapor pressure by existing installations. 展开更多
关键词 体积变化率 测量装置 测量仪器 高温熔融 材料 热探针 温度控制器 密度计算
下载PDF
Measuring methods for three kinds of polyhydroxyalkanoates from activated sludge by gas chromatography
12
作者 陈玮 陈志强 +2 位作者 吕炳南 温沁雪 张运海 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期113-118,共6页
Gas chromatography determination of polyhydroxyalkanoates has been common;however,the pretreatment steps are often complex,and gas chromatography operation conditions are not given in detail.In this study,gas chromato... Gas chromatography determination of polyhydroxyalkanoates has been common;however,the pretreatment steps are often complex,and gas chromatography operation conditions are not given in detail.In this study,gas chromatography is used for analyzing PHB,PHV and PH2MV,three majors of PHAs in activated sludge.The sample was centrifuged at a speed of 4000 r/min for the separation of floc and supernatant,freezen,and dried for 12 h in vacuum freezing drier;and then transferred to the fridge for freezing to ice and drying for 12 h in vacuum freezing drier;then chloroform and a simple composition digestion solution including methanol,sulfuric acid and benzoic acid was added;digested at 105 ℃ for 6 h;cooled to room temperature,the lower solution of the result can be used for analyzing.Samples were analyzed by gas chromatography with FID detector and auto sampler;the standard curve of standard material shows an excellent linear relationship with correlation coefficients larger than 0.99;the relative standard deviation (RSD) of sludge samples is less than 1%.The recovery rates of each sample are between 95%-105%.The GC analysis time of each PHA sample is shorter than 10 minutes. 展开更多
关键词 POLYHYDROXYALKANOATES activated sludge gas chromatography measuring method
下载PDF
NEW METHOD FOR MEASURING SECONDARY ELECTRON EMISSION OF THERMIONIC CATHODE AND ITS APPLICATION
13
作者 陈德森 孙学民 《Journal of Electronics(China)》 1990年第3期273-279,共7页
By using correlation-detection technique and improving structure of the test tube,the background noise of thermionic-electrons and space charge effect are restrained.The sec-ondary emission coefficient δ of thermioni... By using correlation-detection technique and improving structure of the test tube,the background noise of thermionic-electrons and space charge effect are restrained.The sec-ondary emission coefficient δ of thermionic cathode at high temperature has been studied.Theδ of impregnated scandate cathodes increases exponentially with increasing temperature at lowenergy and current of the bombardment electrons;at high energy or current of the bombardmentelectrons the temperature has little effect on δ.The research shows that an enhanced thermionicemission occurred when the cathode works at high temperature and under electron bombardment.These phenomena are discussed in terms of “internal field model”. 展开更多
关键词 Thermionic CATHODE method for measuring SECONDARY electron emission SCANDATE CATHODE INTERNAL field model
下载PDF
Simulation on Calculation Accuracy of Three Methods for Live Line Measuring the Parameters of Transmission Lines with Mutual Inductance
14
作者 Jianjun Su Ronghua Zhang +6 位作者 Demin Cui Yongqiang Chai Xiaobo Li Chengxue Zhang Peiyan Li Zhijian Hu Yingying Hu 《Energy and Power Engineering》 2013年第4期1435-1439,共5页
Live line measurement methods can reduce the loss of power outages and eliminate interference. There are three live line measurement methods including integral method, differential method and algebraic method. A simul... Live line measurement methods can reduce the loss of power outages and eliminate interference. There are three live line measurement methods including integral method, differential method and algebraic method. A simulation model of?two coupled parallel transmission lines spanning on the same towers is built in PSCAD and the calculation errors of these three methods are compared with different sampling frequencies by using of Matlab. The effect of harmonic on calculation is also involved. The simulation results indicate that harmonic has the least effect on the algebraic method which provides stable result and small error. 展开更多
关键词 Lines with Mutual INDUCTANCE Zero Sequence Parameters LIVE LINE measurement ALGEBRAIC method Differential method INTEGRAL method
下载PDF
Method of Predicting Water Content in Crude Oil Based on Measuring Range Automatic Switching
15
作者 陈祥光 朱文博 +1 位作者 赵军 任磊 《Journal of Beijing Institute of Technology》 EI CAS 2010年第1期87-91,共5页
Water content in output crude oil is hard to measure precisely because of wide range of dielectric coefficient of crude oil caused by injected dehydrating and demulsifying agents.The method to reduce measurement error... Water content in output crude oil is hard to measure precisely because of wide range of dielectric coefficient of crude oil caused by injected dehydrating and demulsifying agents.The method to reduce measurement error of water content in crude oil proposed in this paper is based on switching measuring ranges of on-line water content analyzer automatically.Measuring precision on data collected from oil field and analyzed by in-field operators can be impressively improved by using back propogation (BP) neural network to predict water content in output crude oil.Application results show that the difficulty in accurately measuring water-oil content ratio can be solved effectively through this combination of on-line measuring range automatic switching and real time prediction,as this method has been tested repeatedly on-site in oil fields with satisfactory prediction results. 展开更多
关键词 water content in crude oil prediction method BP network measuring range automatic switching
下载PDF
A Novel Method for Measuring Electro-optic Coefficient of Poled Polymer Waveguide
16
《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1998年第1期16-19,共4页
ANovelMethodforMeasuringElectro-opticCoefficientofPoledPolymerWaveguideYANGLijun,GENGWanzhen,XUJiandong,HONG... ANovelMethodforMeasuringElectro-opticCoefficientofPoledPolymerWaveguideYANGLijun,GENGWanzhen,XUJiandong,HONGJing(杨黎俊)(耿完桢)(徐建... 展开更多
关键词 徐建 COEFFICIENT Poled measuring method 杨黎
下载PDF
MEASURING PRECISION OF INDUCED POLARIZATION METHOD
17
作者 He,Jishan(Central South University of Technology,Changsha 410083) 《中国有色金属学会会刊:英文版》 CSCD 1994年第4期1-6,共6页
MEASURINGPRECISIONOFINDUCEDPOLARIZATIONMETHOD¥He,Jishan(CentralSouthUniversityofTechnology,Changsha410083)Ab... MEASURINGPRECISIONOFINDUCEDPOLARIZATIONMETHOD¥He,Jishan(CentralSouthUniversityofTechnology,Changsha410083)Abstract:Onthepremi... 展开更多
关键词 measuring PRECISION induced POLARIZATION method (IP) DUAL-FREQUENCY IP FREQUENCY DOMAIN IP time IP
下载PDF
Definition,measuring methods and status of carbon information disclosure in Chinese enterprises
18
作者 CHEN Hua WANG Hai-yan 《Ecological Economy》 2015年第4期393-400,共8页
From the perspective of carbon disclosure goal,the paper defined the detail types of contents about carbon information disclosure,then constructed the carbon information disclosure index,by using the indices to 2011 a... From the perspective of carbon disclosure goal,the paper defined the detail types of contents about carbon information disclosure,then constructed the carbon information disclosure index,by using the indices to 2011 annual report of A-share listed companies in Shanghai and Shenzhen Security Exchange,we found that Chinese enterprises' carbon disclosure scattered,industry structure quite different characteristics,quantity information and quality information asymmetry. 展开更多
关键词 CARBON information DISCLOSURE content DEFINITION measuring methods STATUS DESCRIPTION
下载PDF
Non-invasive glucose measuring apparatus based on conservation of energy method 被引量:1
19
作者 陈真诚 金星亮 +2 位作者 朱健铭 王弟亚 张婷婷 《Journal of Central South University》 SCIE EI CAS 2009年第6期982-986,共5页
A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardwa... A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed,which can measure blood glucose level (BGL) frequently,conveniently and painlessly. The hardware and software of this apparatus were designed,and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism,and the relationship between convection,evaporation,radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method,using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other,and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A:100%,region B:0%). Accordingly,it is feasible to measure BGL with COEM. 展开更多
关键词 节约能源法 血糖水平 测量仪 非侵入式 MSP430F149 全自动生化分析仪 能量守恒定律 基础
下载PDF
An overview on observational instruments and measuring methods for dewfall 被引量:1
20
作者 Qiang Zhang XiaoCui Hao +2 位作者 XiaoMei Wen Sheng Wang Jian Zeng 《Research in Cold and Arid Regions》 2011年第1期78-85,共8页
This paper systematically summarizes previous measuring methods and observational instruments for the magnitude of dewfall on land surface,analyzes the characteristics of common observational instruments for land surf... This paper systematically summarizes previous measuring methods and observational instruments for the magnitude of dewfall on land surface,analyzes the characteristics of common observational instruments for land surface dewfall,and describes several ba-sic dewfall measurement methods.Moreover,the basic principles of these methods and instruments are interpreted,and their ad-vantages,disadvantages,and applicability are analyzed.Recommendations for the further improvement of these observational in-struments and the development of dewfall measuring methods are presented,and new technologies and scientific proposals for exploiting dewfall are elucidated. 展开更多
关键词 表面结露 测量方法 观测仪器 综述 适用性 土地
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部