Based on fuzzy Gaussian mixture model (FGMM) and support vector regression (SVR),an improved version of non-intrusive objective measurement for assessing quality of output speech without inputting clean speech is ...Based on fuzzy Gaussian mixture model (FGMM) and support vector regression (SVR),an improved version of non-intrusive objective measurement for assessing quality of output speech without inputting clean speech is proposed for narrowband speech.Its perceptual linear predictive (PLP) features extracted from clean speech and clustered by FGMM are used as an artificial reference model.Input speech is separated into three classes,for each a consistency parameter between each feature pair from test speech signals and its counterpart in the pre-trained FGMM reference model is calculated and mapped to an objective speech quality score using SVR method.The correlation degree between subjective mean opinion score (MOS) and objective MOS is analyzed.Experimental results show that the proposed method offers an effective technique and can give better performances than the ITU-T P.563 method under most of the test conditions for narrowband speech.展开更多
Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and ...Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and poor anti-vibration ability,a non-intrusive flowrate measurement and monitoring system of plant-protection UAS was developed based on pump voice signal analysis.It is mainly composed of STM32 processor,microphone and signal-conditioning circuit.By collecting and analyzing the voice signal of the pump in the UAS,the monitoring system will output the real-time values of spraying flowrate and amount.An extraction model was developed to determine operation status and primary frequency of the pump based on voice signal analysis.Real-time spray flowrate can be determined from the real-time extracted primary frequency and the fitted correlation formulas of spraying flowrate under outlet area and pump primary frequency.The flowrate correlation equation of one certain pump from 4-rotor UAS 3WQFTX-1011S was obtained,the max deviation rate of fitted spray flowrate was only 2.8%.In primary frequency extraction test,the error rate of primary frequency extraction was less than 1%.In the 4-rotor UAS flight tests:the max deviation of operating starting/end point was only 0.7 s and the max deviation of extracted total operating time was only 0.8 s;the deviation of extracted spray flowrate was less than 2%,and the max deviation rate of total spray amount was 3.2%.This research could be used as a guidance for plant-protection UAS non-intrusive flowrate measurement and monitoring.展开更多
We propose a new non-intrusive flow measurement method using the distributed feedback fiber laser(DFB-FL)as a sensor to monitor flow in the pipe.The relationship between the wavelength of the DFB-FL and the liquid flo...We propose a new non-intrusive flow measurement method using the distributed feedback fiber laser(DFB-FL)as a sensor to monitor flow in the pipe.The relationship between the wavelength of the DFB-FL and the liquid flow rate in the pipeline is derived.Under the guidance of this theory,the design and test of the flow sensor is completed.The response curve is relatively flat in the frequency range of 10 Hz to 500 Hz,and the response of the flow sensor has high linearity.The flow from 0.6 m^3/h to 25.5 m^3/h is accurately measured under the energy analysis method in different frequency intervals.A minimum flow rate of 0.046 m/s is achieved.The experimental results demonstrate the feasibility of the new non-intrusive flow measurement method based on the DFB-FL and accurate measurement of small flow rates.展开更多
Accurate prediction of hypersonic boundary-layer transition plays an important role in thermal protection system design of hypersonic vehicles.Restricted by the capability of spatial diagnostics for hypersonic boundar...Accurate prediction of hypersonic boundary-layer transition plays an important role in thermal protection system design of hypersonic vehicles.Restricted by the capability of spatial diagnostics for hypersonic boundary-layer study,quite a lot of problems of hypersonic boundary-layer transition,such as nonlinearity and receptivity,remain outstanding.This work reports the application of focused laser differential interferometer to instability wave development across hypersonic boundary-layer on a flared cone model.To begin with,the focused laser differential interferometer is designed and set up in a Mach number 6 hypersonic quiet wind tunnel with the focal point in the laminar boundary-layer of a 5 degree half-angle flared cone model.Afterwards,instability experiments are carried out by traversing the focal point throughout the hypersonic boundary-layer and the density fluctuation along the boundary-layer profile is measured and analyzed.The results show that three types of instability waves ranging from 10 k Hz to over 1 MHz are co-existing in the hypersonic boundary-layer,indicating the powerful capability of focused laser differential interferometer in dynamic response resolution for instability wave study in hypersonic flow regime;furthermore,quantitative analyses including spectra and bicoherence analysis of instability waves throughout the hypersonic boundary-layer for both cold and heated cone models are performed.展开更多
A mini-vane four-rod radio frequency quadruple (RFQ) accelerator has been built for neutron imaging. The RFQ will operate at 201.5 MHz, and its length is 2.7 m. The original electric field distribution along the elect...A mini-vane four-rod radio frequency quadruple (RFQ) accelerator has been built for neutron imaging. The RFQ will operate at 201.5 MHz, and its length is 2.7 m. The original electric field distribution along the electrodes is not flat. The resonant frequency needs to be tuned to the operating value. And the frequency needs to be compensated for temperature change during high power RF test and beam test. As tuning such a RFQ is difficult, plate tuners and stick tuners are designed. This paper will present the tuners design, the tuning procedure, and the RF properties of the RFQ.展开更多
文摘Based on fuzzy Gaussian mixture model (FGMM) and support vector regression (SVR),an improved version of non-intrusive objective measurement for assessing quality of output speech without inputting clean speech is proposed for narrowband speech.Its perceptual linear predictive (PLP) features extracted from clean speech and clustered by FGMM are used as an artificial reference model.Input speech is separated into three classes,for each a consistency parameter between each feature pair from test speech signals and its counterpart in the pre-trained FGMM reference model is calculated and mapped to an objective speech quality score using SVR method.The correlation degree between subjective mean opinion score (MOS) and objective MOS is analyzed.Experimental results show that the proposed method offers an effective technique and can give better performances than the ITU-T P.563 method under most of the test conditions for narrowband speech.
基金The research was supported by National Key R&D Program of China(Grant No.2017YFD0701000,2018YFD0200900)China Agriculture Research System of MOF and MARA(Grant No.CARS-12)Chinese Academy of Agricultural Sciences Fundamental Research Funds(Grant No.SR201903).
文摘Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and poor anti-vibration ability,a non-intrusive flowrate measurement and monitoring system of plant-protection UAS was developed based on pump voice signal analysis.It is mainly composed of STM32 processor,microphone and signal-conditioning circuit.By collecting and analyzing the voice signal of the pump in the UAS,the monitoring system will output the real-time values of spraying flowrate and amount.An extraction model was developed to determine operation status and primary frequency of the pump based on voice signal analysis.Real-time spray flowrate can be determined from the real-time extracted primary frequency and the fitted correlation formulas of spraying flowrate under outlet area and pump primary frequency.The flowrate correlation equation of one certain pump from 4-rotor UAS 3WQFTX-1011S was obtained,the max deviation rate of fitted spray flowrate was only 2.8%.In primary frequency extraction test,the error rate of primary frequency extraction was less than 1%.In the 4-rotor UAS flight tests:the max deviation of operating starting/end point was only 0.7 s and the max deviation of extracted total operating time was only 0.8 s;the deviation of extracted spray flowrate was less than 2%,and the max deviation rate of total spray amount was 3.2%.This research could be used as a guidance for plant-protection UAS non-intrusive flowrate measurement and monitoring.
基金supported by the National Natural Science Foundation of China(No.61605101)the Focus of R&D Projects of Shandong Province(No.2019GSF111065).
文摘We propose a new non-intrusive flow measurement method using the distributed feedback fiber laser(DFB-FL)as a sensor to monitor flow in the pipe.The relationship between the wavelength of the DFB-FL and the liquid flow rate in the pipeline is derived.Under the guidance of this theory,the design and test of the flow sensor is completed.The response curve is relatively flat in the frequency range of 10 Hz to 500 Hz,and the response of the flow sensor has high linearity.The flow from 0.6 m^3/h to 25.5 m^3/h is accurately measured under the energy analysis method in different frequency intervals.A minimum flow rate of 0.046 m/s is achieved.The experimental results demonstrate the feasibility of the new non-intrusive flow measurement method based on the DFB-FL and accurate measurement of small flow rates.
基金the State Key Laboratory for Turbulence&Complex Systems of Peking University for their support in this studysupport of National Numerical Wind-tunnel(No.2018-ZT1A03)+1 种基金National Natural Science Foundation of China grant(No.11702106)Fundamental Research Funds for the Central Universities(2019kfyXKJC001)。
文摘Accurate prediction of hypersonic boundary-layer transition plays an important role in thermal protection system design of hypersonic vehicles.Restricted by the capability of spatial diagnostics for hypersonic boundary-layer study,quite a lot of problems of hypersonic boundary-layer transition,such as nonlinearity and receptivity,remain outstanding.This work reports the application of focused laser differential interferometer to instability wave development across hypersonic boundary-layer on a flared cone model.To begin with,the focused laser differential interferometer is designed and set up in a Mach number 6 hypersonic quiet wind tunnel with the focal point in the laminar boundary-layer of a 5 degree half-angle flared cone model.Afterwards,instability experiments are carried out by traversing the focal point throughout the hypersonic boundary-layer and the density fluctuation along the boundary-layer profile is measured and analyzed.The results show that three types of instability waves ranging from 10 k Hz to over 1 MHz are co-existing in the hypersonic boundary-layer,indicating the powerful capability of focused laser differential interferometer in dynamic response resolution for instability wave study in hypersonic flow regime;furthermore,quantitative analyses including spectra and bicoherence analysis of instability waves throughout the hypersonic boundary-layer for both cold and heated cone models are performed.
基金supported by the National Natural Science Foundation of China (Grant No. 107035020)the National Basic Research Program of China (Grant No. 2010CB833106)
文摘A mini-vane four-rod radio frequency quadruple (RFQ) accelerator has been built for neutron imaging. The RFQ will operate at 201.5 MHz, and its length is 2.7 m. The original electric field distribution along the electrodes is not flat. The resonant frequency needs to be tuned to the operating value. And the frequency needs to be compensated for temperature change during high power RF test and beam test. As tuning such a RFQ is difficult, plate tuners and stick tuners are designed. This paper will present the tuners design, the tuning procedure, and the RF properties of the RFQ.