期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Non-Intrusive Objective Speech Quality Measurement Based on Fuzzy GMM and SVR for Narrowband Speech
1
作者 王晶 张莹 +1 位作者 赵胜辉 匡镜明 《Journal of Beijing Institute of Technology》 EI CAS 2010年第1期76-81,共6页
Based on fuzzy Gaussian mixture model (FGMM) and support vector regression (SVR),an improved version of non-intrusive objective measurement for assessing quality of output speech without inputting clean speech is ... Based on fuzzy Gaussian mixture model (FGMM) and support vector regression (SVR),an improved version of non-intrusive objective measurement for assessing quality of output speech without inputting clean speech is proposed for narrowband speech.Its perceptual linear predictive (PLP) features extracted from clean speech and clustered by FGMM are used as an artificial reference model.Input speech is separated into three classes,for each a consistency parameter between each feature pair from test speech signals and its counterpart in the pre-trained FGMM reference model is calculated and mapped to an objective speech quality score using SVR method.The correlation degree between subjective mean opinion score (MOS) and objective MOS is analyzed.Experimental results show that the proposed method offers an effective technique and can give better performances than the ITU-T P.563 method under most of the test conditions for narrowband speech. 展开更多
关键词 non-intrusive measurement objective speech quality fuzzy Gaussian mixture model (FGMM) support vector regression (SVR)
下载PDF
Non-intrusive flowrate measurement and monitoring system of plant-protection unmanned aircraft systems based on pump voice analysis 被引量:1
2
作者 Yang Xu Xinyu Xue +1 位作者 Zhu Sun Wei Gu 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2021年第3期58-65,共8页
Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and ... Application of Unmanned Aircraft Systems(UAS)for plant protection is becoming a common tool in agricultural field management.To avoid shortcomings of intrusive flowrate sensors including poor measurement accuracy and poor anti-vibration ability,a non-intrusive flowrate measurement and monitoring system of plant-protection UAS was developed based on pump voice signal analysis.It is mainly composed of STM32 processor,microphone and signal-conditioning circuit.By collecting and analyzing the voice signal of the pump in the UAS,the monitoring system will output the real-time values of spraying flowrate and amount.An extraction model was developed to determine operation status and primary frequency of the pump based on voice signal analysis.Real-time spray flowrate can be determined from the real-time extracted primary frequency and the fitted correlation formulas of spraying flowrate under outlet area and pump primary frequency.The flowrate correlation equation of one certain pump from 4-rotor UAS 3WQFTX-1011S was obtained,the max deviation rate of fitted spray flowrate was only 2.8%.In primary frequency extraction test,the error rate of primary frequency extraction was less than 1%.In the 4-rotor UAS flight tests:the max deviation of operating starting/end point was only 0.7 s and the max deviation of extracted total operating time was only 0.8 s;the deviation of extracted spray flowrate was less than 2%,and the max deviation rate of total spray amount was 3.2%.This research could be used as a guidance for plant-protection UAS non-intrusive flowrate measurement and monitoring. 展开更多
关键词 plant protection UAS voice signal analysis non-intrusive flowrate measurement monitoring system
原文传递
Non-intrusive flow measurement based on a distributed feedback fiber laser
3
作者 Jiasheng Ni Ying Shang +6 位作者 Chen Wang Wenan Zhao Chang Li Bing Cao Sheng Huang Chang Wang Gangding Peng 《Chinese Optics Letters》 SCIE EI CAS CSCD 2020年第2期44-47,共4页
We propose a new non-intrusive flow measurement method using the distributed feedback fiber laser(DFB-FL)as a sensor to monitor flow in the pipe.The relationship between the wavelength of the DFB-FL and the liquid flo... We propose a new non-intrusive flow measurement method using the distributed feedback fiber laser(DFB-FL)as a sensor to monitor flow in the pipe.The relationship between the wavelength of the DFB-FL and the liquid flow rate in the pipeline is derived.Under the guidance of this theory,the design and test of the flow sensor is completed.The response curve is relatively flat in the frequency range of 10 Hz to 500 Hz,and the response of the flow sensor has high linearity.The flow from 0.6 m^3/h to 25.5 m^3/h is accurately measured under the energy analysis method in different frequency intervals.A minimum flow rate of 0.046 m/s is achieved.The experimental results demonstrate the feasibility of the new non-intrusive flow measurement method based on the DFB-FL and accurate measurement of small flow rates. 展开更多
关键词 DFB-FL FLOW non-intrusive measurement ENERGY analysis FREQUENCY INTERVAL
原文传递
Application of focused laser differential interferometer to hypersonic boundary-layer instability study 被引量:4
4
作者 Tao YU Youde XIONG +1 位作者 Jiaquan ZHAO Jie WU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2021年第5期17-26,共10页
Accurate prediction of hypersonic boundary-layer transition plays an important role in thermal protection system design of hypersonic vehicles.Restricted by the capability of spatial diagnostics for hypersonic boundar... Accurate prediction of hypersonic boundary-layer transition plays an important role in thermal protection system design of hypersonic vehicles.Restricted by the capability of spatial diagnostics for hypersonic boundary-layer study,quite a lot of problems of hypersonic boundary-layer transition,such as nonlinearity and receptivity,remain outstanding.This work reports the application of focused laser differential interferometer to instability wave development across hypersonic boundary-layer on a flared cone model.To begin with,the focused laser differential interferometer is designed and set up in a Mach number 6 hypersonic quiet wind tunnel with the focal point in the laminar boundary-layer of a 5 degree half-angle flared cone model.Afterwards,instability experiments are carried out by traversing the focal point throughout the hypersonic boundary-layer and the density fluctuation along the boundary-layer profile is measured and analyzed.The results show that three types of instability waves ranging from 10 k Hz to over 1 MHz are co-existing in the hypersonic boundary-layer,indicating the powerful capability of focused laser differential interferometer in dynamic response resolution for instability wave study in hypersonic flow regime;furthermore,quantitative analyses including spectra and bicoherence analysis of instability waves throughout the hypersonic boundary-layer for both cold and heated cone models are performed. 展开更多
关键词 Bicoherence analysis Focused laser differential interferometer Hypersonic boundary-layer instability non-intrusive measurement Wind tunnel experiment
原文传递
Tuner design and RF test of a four-rod RFQ
5
作者 QuanFeng Zhou (1) Kun Zhu (1) +4 位作者 ZhiYu Guo (1) MingLei Kang (1) ShuLi Gao (1) YuanRong Lu (1) JiaEr Chen (1) 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2011年第S2期271-273,共3页
A mini-vane four-rod radio frequency quadruple (RFQ) accelerator has been built for neutron imaging. The RFQ will operate at 201.5 MHz, and its length is 2.7 m. The original electric field distribution along the elect... A mini-vane four-rod radio frequency quadruple (RFQ) accelerator has been built for neutron imaging. The RFQ will operate at 201.5 MHz, and its length is 2.7 m. The original electric field distribution along the electrodes is not flat. The resonant frequency needs to be tuned to the operating value. And the frequency needs to be compensated for temperature change during high power RF test and beam test. As tuning such a RFQ is difficult, plate tuners and stick tuners are designed. This paper will present the tuners design, the tuning procedure, and the RF properties of the RFQ. 展开更多
关键词 four-rod RFQ electric-field DISTRIBUTION RF tuning RF measurement
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部