This paper establishes a non-linear finite element model (NFEM) of L4-L5 lumbar spinal segment with accurate three-dimensional solid ligaments and intervertebral disc. For the purpose, the intervertebral disc and surr...This paper establishes a non-linear finite element model (NFEM) of L4-L5 lumbar spinal segment with accurate three-dimensional solid ligaments and intervertebral disc. For the purpose, the intervertebral disc and surrounding ligaments are modeled with four-nodal three-dimensional tetrahedral elements with hyper-elastic material properties. Pure moment of 10 N·m without preload is applied to the upper vertebral body under the loading conditions of lateral bending, backward extension, torsion, and forward flexion, respectively. The simulate relationship curves between generalized forces and generalized displacement of the NFEM are compared with the in vitro experimental result curves to verify NFEM. The verified results show that: (1) The range of simulated motion is a good agreement with the in vitro experimental data; (2) The NFEM can more effectively reffect the actual mechanical properties than the FE model using cable and spring elements ligaments; (3) The NFEM can be used as the basis for further research on lumbar degenerative diseases.展开更多
1 Introduction Mengla Basin is a sub-basin in southern evaporitebearing Lanping-Simao Basin.There are many salt springs in the basin.In 2012,11 spring samples were collected for analyses of chemistry and boron,hydroge...1 Introduction Mengla Basin is a sub-basin in southern evaporitebearing Lanping-Simao Basin.There are many salt springs in the basin.In 2012,11 spring samples were collected for analyses of chemistry and boron,hydrogen and oxygen展开更多
<p align="left"> <span style="font-family:Verdana;">The present study evaluates the effects of occlusal loading on an implant-supported dental implant with external hexagon dental impla...<p align="left"> <span style="font-family:Verdana;">The present study evaluates the effects of occlusal loading on an implant-supported dental implant with external hexagon dental implant-abutment systems, using the finite element method analysis. Tensile analyses were performed to simulate different axial and obliquous masticatory loads. The influence of the variations in the contouring conditions of the interfaces was analyzed to weigh the osseointegration with linear and non-linear cases, by means of a parametric design. The geometry selected to place the prostheses was a jaw section, considering the properties of the set of cortical and trabecular bones. The results show that for non-linear contour conditions, the stress presents smaller value distributions and signals a different place in the screw-implant interface as the factor of the greater weight in this study. The location indicated that von Mises stress concentrations are not exclusive to the contact regions studied, moving to an area that is not in direct contact with the non-linear contact interfaces. In addition, the direction of load with an angle of 15 degrees presented the highest values of von Mises stress.</span> </p>展开更多
Over the years, there has been increased research interest in the application of Nitinol as an actuator, due to its shape memory behaviour, simplicity, high power-to-weight ratio, compactness, and extreme high fatigue...Over the years, there has been increased research interest in the application of Nitinol as an actuator, due to its shape memory behaviour, simplicity, high power-to-weight ratio, compactness, and extreme high fatigue resistance to cyclic motion, and noiseless operation. Nitinol has found application in tactile displays which reproduce tactile parameters such as texture and shape, depending on the application. This paper presents the effects of thermal interference between adjacent Nitinol spring actuators in a tactile display. The tactile display is made of a 3 by 3 pin array whose spatial resolution was varied from 4 mm to 6 mm in steps of 1 mm while a current of 1.5 A was used to actuate 8 of the springs, and the centre spring was left unactivated to observe the thermal effects on it due to the heat gradient formed. A Finite Element (FE) model was developed using COMSOL Multiphysics and the results were further verified through experimentation. In both cases, there was visible thermal interference between actuators. The increase in spatial resolution saw a decrease in thermal interference by 12.7%. Using a fan to introduce forced convection, reduced the thermal interference in the simulation by 20% and during experimentation by 11%. The results of this research indicate a spatial resolution of 6 mm reduced the thermal inference to a negligible rate. However, thermal interference could not be eliminated with these two methods.展开更多
The equilibrium equations and the functional for tubing buckling in arbitrary straight wells are derived. The entire buckling process of tubing in deviated wells is analyzed for the first time by utilizing the finite ...The equilibrium equations and the functional for tubing buckling in arbitrary straight wells are derived. The entire buckling process of tubing in deviated wells is analyzed for the first time by utilizing the finite element method. The effects of gravity and torques on the buckling are included in the analyses and the calculated results are well compared with existing solutions. It is shown that the buckling only occurs at the lower portion of the tubing where the axial load is the largest, and the contact force of the well, the bending moment of the tubing and the buckling displacement of this portion vary periodically. The buckling spreads upwards from the bit with the increase of axial load. There is no buckling at the upper portion of the tubing where the bending moment is zero. And the contact force of this section increases only slightly with the increase of the axial load. With the increase of the deviation angle, the length of buckling portion and buckling displacement amplitude decrease, the contact force increases with the increase of load at the upper portion and its amplitude decreases at the lower buckling section, the bending moment remains zero at the upper portion and its amplitude decreases at the lower buckling portion. The buckling displacement increases with the increase of the torque, but the increment is very small.展开更多
基金supported by the National Natural Science Foundation of China (10832012, 10872078 and10972090)Scientific Advancing Front and Interdiscipline Innovation Project of Jilin University (200903169)
文摘This paper establishes a non-linear finite element model (NFEM) of L4-L5 lumbar spinal segment with accurate three-dimensional solid ligaments and intervertebral disc. For the purpose, the intervertebral disc and surrounding ligaments are modeled with four-nodal three-dimensional tetrahedral elements with hyper-elastic material properties. Pure moment of 10 N·m without preload is applied to the upper vertebral body under the loading conditions of lateral bending, backward extension, torsion, and forward flexion, respectively. The simulate relationship curves between generalized forces and generalized displacement of the NFEM are compared with the in vitro experimental result curves to verify NFEM. The verified results show that: (1) The range of simulated motion is a good agreement with the in vitro experimental data; (2) The NFEM can more effectively reffect the actual mechanical properties than the FE model using cable and spring elements ligaments; (3) The NFEM can be used as the basis for further research on lumbar degenerative diseases.
基金supported by grants from the National Program on Key Basic Research Project of China (973 Program, 2011CB403004)
文摘1 Introduction Mengla Basin is a sub-basin in southern evaporitebearing Lanping-Simao Basin.There are many salt springs in the basin.In 2012,11 spring samples were collected for analyses of chemistry and boron,hydrogen and oxygen
文摘<p align="left"> <span style="font-family:Verdana;">The present study evaluates the effects of occlusal loading on an implant-supported dental implant with external hexagon dental implant-abutment systems, using the finite element method analysis. Tensile analyses were performed to simulate different axial and obliquous masticatory loads. The influence of the variations in the contouring conditions of the interfaces was analyzed to weigh the osseointegration with linear and non-linear cases, by means of a parametric design. The geometry selected to place the prostheses was a jaw section, considering the properties of the set of cortical and trabecular bones. The results show that for non-linear contour conditions, the stress presents smaller value distributions and signals a different place in the screw-implant interface as the factor of the greater weight in this study. The location indicated that von Mises stress concentrations are not exclusive to the contact regions studied, moving to an area that is not in direct contact with the non-linear contact interfaces. In addition, the direction of load with an angle of 15 degrees presented the highest values of von Mises stress.</span> </p>
文摘Over the years, there has been increased research interest in the application of Nitinol as an actuator, due to its shape memory behaviour, simplicity, high power-to-weight ratio, compactness, and extreme high fatigue resistance to cyclic motion, and noiseless operation. Nitinol has found application in tactile displays which reproduce tactile parameters such as texture and shape, depending on the application. This paper presents the effects of thermal interference between adjacent Nitinol spring actuators in a tactile display. The tactile display is made of a 3 by 3 pin array whose spatial resolution was varied from 4 mm to 6 mm in steps of 1 mm while a current of 1.5 A was used to actuate 8 of the springs, and the centre spring was left unactivated to observe the thermal effects on it due to the heat gradient formed. A Finite Element (FE) model was developed using COMSOL Multiphysics and the results were further verified through experimentation. In both cases, there was visible thermal interference between actuators. The increase in spatial resolution saw a decrease in thermal interference by 12.7%. Using a fan to introduce forced convection, reduced the thermal interference in the simulation by 20% and during experimentation by 11%. The results of this research indicate a spatial resolution of 6 mm reduced the thermal inference to a negligible rate. However, thermal interference could not be eliminated with these two methods.
文摘The equilibrium equations and the functional for tubing buckling in arbitrary straight wells are derived. The entire buckling process of tubing in deviated wells is analyzed for the first time by utilizing the finite element method. The effects of gravity and torques on the buckling are included in the analyses and the calculated results are well compared with existing solutions. It is shown that the buckling only occurs at the lower portion of the tubing where the axial load is the largest, and the contact force of the well, the bending moment of the tubing and the buckling displacement of this portion vary periodically. The buckling spreads upwards from the bit with the increase of axial load. There is no buckling at the upper portion of the tubing where the bending moment is zero. And the contact force of this section increases only slightly with the increase of the axial load. With the increase of the deviation angle, the length of buckling portion and buckling displacement amplitude decrease, the contact force increases with the increase of load at the upper portion and its amplitude decreases at the lower buckling section, the bending moment remains zero at the upper portion and its amplitude decreases at the lower buckling portion. The buckling displacement increases with the increase of the torque, but the increment is very small.