AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmenta...AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.展开更多
AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffract...AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffractive trifocal intraocular lenses(IOL).METHODS:During this retrospective observational study,patients who received bilateral FLACS combined with implantation of two different types of diffractive trifocal IOLs were evaluated.According to the IOLs’different types and design,the patients were divided into AT LISA tri839MP group(tri839 group)and AcrySof PanOptix TFNT00 group(TFNT group).Study parameters included preoperative and postoperative uncorrected distance visual acuity(UDVA)at 5 m,uncorrected near visual acuity(UNVA)at 30 cm and 40 cm,uncorrected intermediate visual acuity(UIVA)at 60 cm and 80 cm,postoperative refractive status,objective visual qualities and total high order aberrations(HOAs)postoperatively.The postoperative complications were also recorded.RESULTS:Totally 56 eyes of 28 patients(tri839 group,n=26;TFNT group,n=30)were included.Preoperative baseline characteristics between groups were not statistically significantly different.UDVA was not significantly different between groups except for 1wk follow-up due to the postoperative corneal edema.TFNT group showed statistically significant better UNIA at 60 cm than tri839 group at the 1wk(0.05±0.19 vs 0.15±0.10 logMAR,P=0.013),1mo(0.05±0.12 vs 0.15±0.09 logMAR,P=0.001)and 3mo(0.04±0.12 vs 0.15±0.11 logMAR,P=0.001)follow-up,while tri839 group showed statistically significant better UNIA at 80 cm than TFNT group at the 1d(0.14±0.15 vs 0.20±0.14 logMAR,P=0.041)and 1mo(0.09±0.07 vs 0.14±0.10 logMAR,P=0.042)follow-up.Postoperative refractive status showed stable at every visit.Modulated transfer function(MTF)values and strehl ratio(SR)values were improved and HOAs were lower significantly after surgery.CONCLUSION:FLACS with bilateral implantations of both tri839 and TFNT00 can achieve satisfactory natural whole-course vision,high postoperative refractive stability and good visual quality but without significantly difference.iTrace aberration instrument can accurately evaluate the visual quality under different status.展开更多
AIM:To compare visual performance of wavefrontguided laser in situ keratomileusis(LASIK) with iris-registration(Wg-LASIK group) and conventional LASIK(LASIK group) one year after surgery and analyze the correlation be...AIM:To compare visual performance of wavefrontguided laser in situ keratomileusis(LASIK) with iris-registration(Wg-LASIK group) and conventional LASIK(LASIK group) one year after surgery and analyze the correlation between wavefront aberrations and visual performance.·METHODS:Eight hundred and fifty-two myopic eyes of 430 patients were enrolled in this prospective study and divided into two groups:Wg-LASIK group(436eyes) and LASIK group(416 eyes).A Wavescan Wavefront aberrometer was used to analyze Zernike coefficients and the root-mean-square(RMS) of higher order aberrations,and Optec 6500 visual function instrument was used to measure contrast sensitivity(CS)before and 3,6,12 months after surgery.·RESULTS:The mean spherical equivalent(SE) in WgLASIK group was significantly better than those in LASIK group one year after surgery(P =0.024).Wg-LASIK eyes showed better CS values than LASIK eyes at all spatial frequencies with and without glare after surgery(P all【0.01).Moreover,the increase of higher RMS(RMSh),coma,RMS3,RMS4,RMS5 in Wg-LASIK group were significantly lower than those in LASIK group 1 year after surgery(P all 【0.05).The increase of coma,spherical aberration(SA),RMS3 and RMS4 in Wg-LASIK and coma and RMS3 in LASIK group were negatively correlated with reduction of contrast sensitivity 1 year after surgery.·CONCLUSION:A significant better visual performance is got in Wg-LASIK group compared with LASIK group 1year after surgery,and the Wg-LASIK is particularly suitable for eyes with high-magnitude RMSh.展开更多
AIM: To compare the visual functional outcomes with accommodating and multifocal intraocular lenses(IOLs).METHODS: Our retrospective comparative study included 51 patients(60 eyes) received implantation of an ac...AIM: To compare the visual functional outcomes with accommodating and multifocal intraocular lenses(IOLs).METHODS: Our retrospective comparative study included 51 patients(60 eyes) received implantation of an accommodating IOL(Tetraflex;16 patients,20 eyes),a refractive multifocal IOL(Re Zoom;18 patients,20 eyes),or a diffractive multifocal IOL(ZMA00;17 patients,20 eyes).Subjective refraction,visual acuity,contrast sensitivity(CS),intraocular aberration,and subjective photic phenomena were detected at 3mo after surgery.RESULTS: The spherical equivalent in the three groups was-0.38±0.54 D,0.14±0.56 D,and 0.35±0.41 D,respectively.No statistically significant differences were found in uncorrected and corrected distance visual acuity and uncorrected intermediate visual acuity among the groups(P=0.39).The Re Zoom group had significantly better distance-corrected intermediate visual acuity than the ZMA00 group(P=0.003).The ZMA00 group had significantly better near visual acuity than the other groups(P〈0.05).Better contrast sensitivity values were observed in the Tetraflex group under most of the spatial frequencies conditions(P=0.025).The total aberration was lowest in the ZMA00 group(P=0.000),and the spherical aberration was highest in the Tetraflex group(P=0.000).The three groups had similar frequency of ghosting and glare,and the Tetraflex group had a low rate of halos(P=0.01).CONCLUSION: Both accommodating and multifocal IOLs can successfully restore distance and uncorrected intermediate visual acuities.Tetraflex accommodating IOLs perform better in CS and with less halos of photic phenomena.Re Zoom refractive multifocal IOLs havebetter performance in distance-corrected intermediate visual acuity than ZMA00 diffractive multifocal IOLs,and the latter achieved better near visual acuity and efficiently decreased the optical aberration.展开更多
The performance evaluation of the process industry, which has been a popular topic nowadays, can not only find the weakness and verify the resilience and reliability of the process, but also provide some suggestions t...The performance evaluation of the process industry, which has been a popular topic nowadays, can not only find the weakness and verify the resilience and reliability of the process, but also provide some suggestions to improve the process benefits and efficiency. Nevertheless, the performance assessment principally concentrates upon some parts of the entire system at present, for example the controller assessment. Although some researches focus on the whole process, they aim at discovering the relationships between profit, society, policies and so forth, instead of relations between overall performance and some manipulated variables, that is, the total plant performance. According to the big data of different performance statuses, this paper proposes a hierarchical framework to select some structured logic rules from monitored variables to estimate the current state of the process. The variables related to safety and profits are regarded as key factors to performance evaluation. To better monitor the process state and observe the performance variation trend of the process, a classificationvisualization method based on kernel principal component analysis(KPCA) and self-organizing map(SOM) is established. The dimensions of big data produced by the process are first reduced by KPCA and then the processed data will be mapped into a two-dimensional grid chart by SOM to evaluate the performance status. The monitoring method is applied to the Tennessee Eastman process. Monitoring results indicate that off-line and on-line performance status can be well detected in a two-dimensional diagram.展开更多
When conducting company performance evaluations,the traditional method cannot reflect the distribution characteristics of the company’s operating conditions in the entire securities market.Gephi is an efficient tool ...When conducting company performance evaluations,the traditional method cannot reflect the distribution characteristics of the company’s operating conditions in the entire securities market.Gephi is an efficient tool for data analysis and visualization in the era of big data.It can convert the evaluation results of all listed companies into nodes and edges,and directly display them in the form of graphs,thus making up for the defects of traditional methods.This paper will take all the listed companies in the Shanghai and Shenzhen Stock Exchange as the analysis object.First uses tushare and web crawlers to collect the financial statement data of these companies.And then,uses the Economic Value Added model to calculate the EVA of each listed company and build graph data.Next,import the graph data into gephi to generate the distribution graph of all listed companies’performance,and summarize the distribution characteristics of business performance.Finally,select a listed company that you want to analyze in detail,using the traditional DuPont analysis method to conduct micro level visualization analysis of the business performance to find the main factors affecting the company’s operating performance.Incorporating gephi into traditional performance analysis methods will make the results of traditional analytical methods more effective and complete.展开更多
A ransomware attack that interrupted the operation of Colonial Pipeline(a large U.S.oil pipeline company),showed that security threats by malware have become serious enough to affect industries and social infrastructu...A ransomware attack that interrupted the operation of Colonial Pipeline(a large U.S.oil pipeline company),showed that security threats by malware have become serious enough to affect industries and social infrastructure rather than individuals alone.The agents and characteristics of attacks should be identified,and appropriate strategies should be established accordingly in order to respond to such attacks.For this purpose,the first task that must be performed is malware classification.Malware creators are well aware of this and apply various concealment and avoidance techniques,making it difficult to classify malware.This study focuses on new features and classification techniques to overcome these difficulties.We propose a behavioral performance visualization method using utilization patterns of system resources,such as the central processing unit,memory,and input/output,that are commonly used in performance analysis or tuning of programs.We extracted the usage patterns of the system resources for ransomware to performbehavioral performance visualization.The results of the classification performance evaluation using the visualization results indicate an accuracy of at least 98.94%with a 3.69%loss rate.Furthermore,we designed and implemented a framework to perform the entire process—from data extraction to behavioral performance visualization and classification performance measurement—that is expected to contribute to related studies in the future.展开更多
Objective: To explore the influence of probucol-assisted retinal photocoagulation therapy on the visual performance and serum biochemical indexes in patients with early proliferative diabetic retinopathy. Methods: A t...Objective: To explore the influence of probucol-assisted retinal photocoagulation therapy on the visual performance and serum biochemical indexes in patients with early proliferative diabetic retinopathy. Methods: A total of 170 patients with early proliferative DR who were treated in the hospital between December 2014 and May 2017 were retrospectively analyzed and divided into the control group (n=107) who received retinal photocoagulation therapy alone and the probucol group (n=63) who received probucol-assisted retinal photocoagulation therapy. The differences in the contents of visual performance indexes as well as serum angiogenesis indexes, inflammatory mediators and oxidative stress indexes were compared between the two groups before treatment and after 6 weeks of treatment. Results: Before treatment, the differences in the levels of visual performance indexes as well as serum contents of angiogenesis indexes, inflammatory mediators and oxidative stress indexes were not statistically significant between the two groups of patients. After 6 weeks of treatment, mean vision, 30 visual acuity and 30-60 visual acuity of probucol group were higher than those of control group;serum angiogenesis indexes HIF-1, VEGF and Ang-2 contents were lower than those of control group;serum inflammatory mediators ICAM-1, IL-2, IL-23 and TNF-α contents were lower than those of control group;serum oxidative stress index MDA content was lower than that of control group whereas TAC content was higher than that of control group. Conclusion: Probucol-assisted retinal photocoagulation therapy can effectively optimize the visual performance and promote the homeostasis recovery in patients with early proliferative diabetic retinopathy.展开更多
Background:This study evaluated the VIsion PERformance(VIPER)simulator’s ability to assess the functional visual performance in warfighters conducting civilian and military tasks.Methods:Thirty service members,aged 2...Background:This study evaluated the VIsion PERformance(VIPER)simulator’s ability to assess the functional visual performance in warfighters conducting civilian and military tasks.Methods:Thirty service members,aged 25–35 years old with a best corrected distance visual acuity(VA)better than or equal to 20/20 or logarithm of the minimum angle of resolution(logMAR)0.00,were randomized to locate and identify road signs and mock improvised explosive devices(IEDs)under either daytime conditions or with infrared imagery,with(cc)and without(sc)wearing their habitual correction.Participants also underwent binocular uncorrected(UDVA)and corrected(CDVA)visual assessment,refraction,contrast sensitivity testing and wavefront aberrometry.Results:The mean age was 28.47 years.The manifest spherical equivalent was–3.16±1.75 diopters(D),the UDVA in both eyes(OU)was logMAR 0.83±0.47,and the CDVA OU was–0.11±0.06.For VIPER,the mean difference in the detection distance(DD)for road signs ccDD vs.scDD was(76.7±52.8)m(P<0.001).The average difference in identification distance(ID)ccID vs.scID was(13.9±6.3)m(P<0.001).The mean accuracies were 83.5%and 27.9%for cc and sc,respectively(P<0.001).The regression analysis indicated that a 1.6 m change in the distance accounts for a 1%change in the accuracy(P=0.002).Without correction,a 4.1 m change accounts for a 1%change in the accuracy(P<0.001).The average IED ccDD was(29.9±8.2)m,and that for scDD was(13.2±13.6)m(P<0.001).The average IED ccID was(32.2±6.2)m and that for the scID was(7.4±10.3)m(P<0.001).The mean IED identification accuracy was 46.7 and 11.4%for cc and sc,respectively(P<0.001).Conclusions:The preliminary results reflect VIPER’s ability to assess functional visual performance when detecting and identifying signs and IEDs.Furthermore,VIPER is able to detect performance changes with and without correction.展开更多
Visual and pictorial materials are extensively used in teaching listening comprehension textbooks. Although the use of still image is currently implemented in some distinguished testing systems, video test is not a po...Visual and pictorial materials are extensively used in teaching listening comprehension textbooks. Although the use of still image is currently implemented in some distinguished testing systems, video test is not a popular modality due to the fact that this kind of test may result in test-takers' confusion during the test. In the present study, a sample of 80 Iranian EFL (English as a Foreign Language) students was selected to compare their performance on three different modalities of listening test: audio-only test, pictorial (listening with still image test), and visual (video) listening test. The analysis of one-way repeated measure ANOVA (Analysis of Variance) was used to compare the students' scores. The results of Bonferroni Post Hoc Test confirm that there were significant differences in scores among audio-only, pictorial, and visual tests. The results of this study highlight the greater performance of students in pictorial listening test which is statistically significant.展开更多
In this paper,we introduce the design and implementation of ParaVT,which is a visual performance analysis and parallel debugging tool.In ParaVT,we propose an automated instrumentation mechanism.Based on this mechanism...In this paper,we introduce the design and implementation of ParaVT,which is a visual performance analysis and parallel debugging tool.In ParaVT,we propose an automated instrumentation mechanism.Based on this mechanism,ParaVT automatically analyzes the performance bottleneck of parallel applications and provides a visual user interface to monitor and analyze the performance of parallel programs.In addition,it also supports certain extensions.展开更多
AIM:To determine the effects of change in light conditions on refractive error and visual functions including visual acuity,stereopsis and contrast sensitivity.METHODS:This cross-sectional study was conducted in the o...AIM:To determine the effects of change in light conditions on refractive error and visual functions including visual acuity,stereopsis and contrast sensitivity.METHODS:This cross-sectional study was conducted in the optometry clinic of the Shahid Beheshti School of Rehabilitation on 48 students in 2021-2022.All of them had eye health and normal visual function and could have refractive errors or not.Light intensity of 4 lx was considered equivalent to photopic light condition and light intensity of 1 lx was considered to be equivalent to mesopic light condition.The amount of refractive error was checked by auto refractometer and its changes in mesopic light condition were subjectively measured.Also,visual acuity,stereopsis and contrast sensitivity(in five spatial frequencies of 1.5,3,6,12,and 18 cycles per degree),were measured first in photopic light condition and then in mesopic light condition,by Snellen control vision chart,stereo butterfly test and the M&S technology monitor test respectively.RESULTS:In the 48 student subjects with an average age of 22.69±3.56y,mean of refractive error as sphere equivalent,visual acuity and stereopsis were-1.25±1.74 diopters,0 logMAR,44.37±13.03 seconds of arc,respectively in photopic light condition while in mesopic light was equal to-1.56±1.75 diopters,0.12±0.09 logMAR and 50.62±33.35 seconds of arc,respectively.The mean of contrast sensitivity measured at spatial frequencies of 1.5,3,6,12,and 18 cycles per degree in photopic condition was equal to 2.38±0.04,2.37±0.07,2.04±0.21,1.27±0.32,0.82±0.27 logarithm of contrast sensitivity,respectively and in mesopic lighting condition was equal to 2.34±0.12,2.30±0.16,1.84±0.28,1.02±0.28,0.63±0.24 logarithm of contrast sensitivity,respectively.Statistical analysis showed a significant difference between the two lighting conditions in all evaluated variables[refractive error(P<0.001),visual acuity(P<0.001),stereopsis(P=0.008)and contrast sensitivity(P<0.001)].CONCLUSION:The refractive error of the student subjects in mesopic light condition change towards myopia,and its amount is clinically significant.Also,the examination and comparison of the factors of visual acuity,stereopsis and contrast sensitivity in these two lighting conditions show that the decrease in brightness level to the mesopic level causes a decrease in the aforementioned visual functions.展开更多
In visible light positioning systems,some scholars have proposed target tracking algorithms to balance the relationship among positioning accuracy,real-time performance,and robustness.However,there are still two probl...In visible light positioning systems,some scholars have proposed target tracking algorithms to balance the relationship among positioning accuracy,real-time performance,and robustness.However,there are still two problems:(1)When the captured LED disappears and the uncertain LED reappears,existing tracking algorithms may recognize the landmark in error;(2)The receiver is not always able to achieve positioning under various moving statuses.In this paper,we propose an enhanced visual target tracking algorithm to solve the above problems.First,we design the lightweight recognition/demodulation mechanism,which combines Kalman filtering with simple image preprocessing to quickly track and accurately demodulate the landmark.Then,we use the Gaussian mixture model and the LED color feature to enable the system to achieve positioning,when the receiver is under various moving statuses.Experimental results show that our system can achieve high-precision dynamic positioning and improve the system’s comprehensive performance.展开更多
基金Supported by the“Municipal School(College)Joint Funding(Zhongnanshan Medical Foundation of Guangdong Province)Project”of Guangzhou Municipal Science and Technology Bureau(No.202201020458)the“Guangzhou Health Science and Technology General Guidance Project(Western Medicine Project)”of Guangzhou Municipal Health Commission(No.20231A011083).
文摘AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.
基金Supported by Medical Science and Technology Research Foundation Project of Guangdong Province(No.C2021087)The Scientific Research Foundation Project of Guangzhou Aier Eye Hospital,Jinan University(No.GA2023004).
文摘AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffractive trifocal intraocular lenses(IOL).METHODS:During this retrospective observational study,patients who received bilateral FLACS combined with implantation of two different types of diffractive trifocal IOLs were evaluated.According to the IOLs’different types and design,the patients were divided into AT LISA tri839MP group(tri839 group)and AcrySof PanOptix TFNT00 group(TFNT group).Study parameters included preoperative and postoperative uncorrected distance visual acuity(UDVA)at 5 m,uncorrected near visual acuity(UNVA)at 30 cm and 40 cm,uncorrected intermediate visual acuity(UIVA)at 60 cm and 80 cm,postoperative refractive status,objective visual qualities and total high order aberrations(HOAs)postoperatively.The postoperative complications were also recorded.RESULTS:Totally 56 eyes of 28 patients(tri839 group,n=26;TFNT group,n=30)were included.Preoperative baseline characteristics between groups were not statistically significantly different.UDVA was not significantly different between groups except for 1wk follow-up due to the postoperative corneal edema.TFNT group showed statistically significant better UNIA at 60 cm than tri839 group at the 1wk(0.05±0.19 vs 0.15±0.10 logMAR,P=0.013),1mo(0.05±0.12 vs 0.15±0.09 logMAR,P=0.001)and 3mo(0.04±0.12 vs 0.15±0.11 logMAR,P=0.001)follow-up,while tri839 group showed statistically significant better UNIA at 80 cm than TFNT group at the 1d(0.14±0.15 vs 0.20±0.14 logMAR,P=0.041)and 1mo(0.09±0.07 vs 0.14±0.10 logMAR,P=0.042)follow-up.Postoperative refractive status showed stable at every visit.Modulated transfer function(MTF)values and strehl ratio(SR)values were improved and HOAs were lower significantly after surgery.CONCLUSION:FLACS with bilateral implantations of both tri839 and TFNT00 can achieve satisfactory natural whole-course vision,high postoperative refractive stability and good visual quality but without significantly difference.iTrace aberration instrument can accurately evaluate the visual quality under different status.
文摘AIM:To compare visual performance of wavefrontguided laser in situ keratomileusis(LASIK) with iris-registration(Wg-LASIK group) and conventional LASIK(LASIK group) one year after surgery and analyze the correlation between wavefront aberrations and visual performance.·METHODS:Eight hundred and fifty-two myopic eyes of 430 patients were enrolled in this prospective study and divided into two groups:Wg-LASIK group(436eyes) and LASIK group(416 eyes).A Wavescan Wavefront aberrometer was used to analyze Zernike coefficients and the root-mean-square(RMS) of higher order aberrations,and Optec 6500 visual function instrument was used to measure contrast sensitivity(CS)before and 3,6,12 months after surgery.·RESULTS:The mean spherical equivalent(SE) in WgLASIK group was significantly better than those in LASIK group one year after surgery(P =0.024).Wg-LASIK eyes showed better CS values than LASIK eyes at all spatial frequencies with and without glare after surgery(P all【0.01).Moreover,the increase of higher RMS(RMSh),coma,RMS3,RMS4,RMS5 in Wg-LASIK group were significantly lower than those in LASIK group 1 year after surgery(P all 【0.05).The increase of coma,spherical aberration(SA),RMS3 and RMS4 in Wg-LASIK and coma and RMS3 in LASIK group were negatively correlated with reduction of contrast sensitivity 1 year after surgery.·CONCLUSION:A significant better visual performance is got in Wg-LASIK group compared with LASIK group 1year after surgery,and the Wg-LASIK is particularly suitable for eyes with high-magnitude RMSh.
基金Supported by the National Natural Science Foundation of China(No.81600721)the Key Laboratory Program of Shandong Eye Institute(NO.2014-1)+2 种基金Medicine Science and Technology Development Program of Shandong Province(No.2015WS0204)the Science and Technology plan of Qingdao,China(No.15-9-1-35-jch)the Innovation Project of Shandong Academy of Medical Sciences
文摘AIM: To compare the visual functional outcomes with accommodating and multifocal intraocular lenses(IOLs).METHODS: Our retrospective comparative study included 51 patients(60 eyes) received implantation of an accommodating IOL(Tetraflex;16 patients,20 eyes),a refractive multifocal IOL(Re Zoom;18 patients,20 eyes),or a diffractive multifocal IOL(ZMA00;17 patients,20 eyes).Subjective refraction,visual acuity,contrast sensitivity(CS),intraocular aberration,and subjective photic phenomena were detected at 3mo after surgery.RESULTS: The spherical equivalent in the three groups was-0.38±0.54 D,0.14±0.56 D,and 0.35±0.41 D,respectively.No statistically significant differences were found in uncorrected and corrected distance visual acuity and uncorrected intermediate visual acuity among the groups(P=0.39).The Re Zoom group had significantly better distance-corrected intermediate visual acuity than the ZMA00 group(P=0.003).The ZMA00 group had significantly better near visual acuity than the other groups(P〈0.05).Better contrast sensitivity values were observed in the Tetraflex group under most of the spatial frequencies conditions(P=0.025).The total aberration was lowest in the ZMA00 group(P=0.000),and the spherical aberration was highest in the Tetraflex group(P=0.000).The three groups had similar frequency of ghosting and glare,and the Tetraflex group had a low rate of halos(P=0.01).CONCLUSION: Both accommodating and multifocal IOLs can successfully restore distance and uncorrected intermediate visual acuities.Tetraflex accommodating IOLs perform better in CS and with less halos of photic phenomena.Re Zoom refractive multifocal IOLs havebetter performance in distance-corrected intermediate visual acuity than ZMA00 diffractive multifocal IOLs,and the latter achieved better near visual acuity and efficiently decreased the optical aberration.
基金Supported by the National Natural Science Foundation of China(61590923,61422303,21376077)
文摘The performance evaluation of the process industry, which has been a popular topic nowadays, can not only find the weakness and verify the resilience and reliability of the process, but also provide some suggestions to improve the process benefits and efficiency. Nevertheless, the performance assessment principally concentrates upon some parts of the entire system at present, for example the controller assessment. Although some researches focus on the whole process, they aim at discovering the relationships between profit, society, policies and so forth, instead of relations between overall performance and some manipulated variables, that is, the total plant performance. According to the big data of different performance statuses, this paper proposes a hierarchical framework to select some structured logic rules from monitored variables to estimate the current state of the process. The variables related to safety and profits are regarded as key factors to performance evaluation. To better monitor the process state and observe the performance variation trend of the process, a classificationvisualization method based on kernel principal component analysis(KPCA) and self-organizing map(SOM) is established. The dimensions of big data produced by the process are first reduced by KPCA and then the processed data will be mapped into a two-dimensional grid chart by SOM to evaluate the performance status. The monitoring method is applied to the Tennessee Eastman process. Monitoring results indicate that off-line and on-line performance status can be well detected in a two-dimensional diagram.
基金This research is funded by the National Social Science Fund Project,grant number 14BJL086.This research is funded by the Open Foundation for the University Innovation Platform in the Hunan Province,grant number 18K103Hunan Provincial Natural Science Foundation of China,grant number 2017JJ2016+2 种基金Accurate crawler design and implementation with a data cleaning function,National Students innovation and entrepreneurship of training program,grant number 201811532010This research work is implemented at the 2011 Collaborative Innovation Center for Development and Utilization of Finance and Economics Big Data Property,Universities of Hunan Province.Open project,grant number 20181901CRP03,20181901CRP04,20181901CRP05National Social Science Fund Project:Research on the Impact Mechanism of China’s Capital Space Flow on Regional Economic Development(Project No.14BJL086)。
文摘When conducting company performance evaluations,the traditional method cannot reflect the distribution characteristics of the company’s operating conditions in the entire securities market.Gephi is an efficient tool for data analysis and visualization in the era of big data.It can convert the evaluation results of all listed companies into nodes and edges,and directly display them in the form of graphs,thus making up for the defects of traditional methods.This paper will take all the listed companies in the Shanghai and Shenzhen Stock Exchange as the analysis object.First uses tushare and web crawlers to collect the financial statement data of these companies.And then,uses the Economic Value Added model to calculate the EVA of each listed company and build graph data.Next,import the graph data into gephi to generate the distribution graph of all listed companies’performance,and summarize the distribution characteristics of business performance.Finally,select a listed company that you want to analyze in detail,using the traditional DuPont analysis method to conduct micro level visualization analysis of the business performance to find the main factors affecting the company’s operating performance.Incorporating gephi into traditional performance analysis methods will make the results of traditional analytical methods more effective and complete.
基金This work was supported by the Institute of Information&Communications Technology Planning&Evaluation(IITP)(Project No.2019-0-00426%,10%)the ICT R&D Program of MSIT/IITP(Project No.2021-0-01816,A Research on Core Technology of Autonomous Twins for Metaverse,10%)National Research Foundation of Korea(NRF)grant funded by the Korean government(Project No.NRF-2020R1A2C4002737%,80%).
文摘A ransomware attack that interrupted the operation of Colonial Pipeline(a large U.S.oil pipeline company),showed that security threats by malware have become serious enough to affect industries and social infrastructure rather than individuals alone.The agents and characteristics of attacks should be identified,and appropriate strategies should be established accordingly in order to respond to such attacks.For this purpose,the first task that must be performed is malware classification.Malware creators are well aware of this and apply various concealment and avoidance techniques,making it difficult to classify malware.This study focuses on new features and classification techniques to overcome these difficulties.We propose a behavioral performance visualization method using utilization patterns of system resources,such as the central processing unit,memory,and input/output,that are commonly used in performance analysis or tuning of programs.We extracted the usage patterns of the system resources for ransomware to performbehavioral performance visualization.The results of the classification performance evaluation using the visualization results indicate an accuracy of at least 98.94%with a 3.69%loss rate.Furthermore,we designed and implemented a framework to perform the entire process—from data extraction to behavioral performance visualization and classification performance measurement—that is expected to contribute to related studies in the future.
文摘Objective: To explore the influence of probucol-assisted retinal photocoagulation therapy on the visual performance and serum biochemical indexes in patients with early proliferative diabetic retinopathy. Methods: A total of 170 patients with early proliferative DR who were treated in the hospital between December 2014 and May 2017 were retrospectively analyzed and divided into the control group (n=107) who received retinal photocoagulation therapy alone and the probucol group (n=63) who received probucol-assisted retinal photocoagulation therapy. The differences in the contents of visual performance indexes as well as serum angiogenesis indexes, inflammatory mediators and oxidative stress indexes were compared between the two groups before treatment and after 6 weeks of treatment. Results: Before treatment, the differences in the levels of visual performance indexes as well as serum contents of angiogenesis indexes, inflammatory mediators and oxidative stress indexes were not statistically significant between the two groups of patients. After 6 weeks of treatment, mean vision, 30 visual acuity and 30-60 visual acuity of probucol group were higher than those of control group;serum angiogenesis indexes HIF-1, VEGF and Ang-2 contents were lower than those of control group;serum inflammatory mediators ICAM-1, IL-2, IL-23 and TNF-α contents were lower than those of control group;serum oxidative stress index MDA content was lower than that of control group whereas TAC content was higher than that of control group. Conclusion: Probucol-assisted retinal photocoagulation therapy can effectively optimize the visual performance and promote the homeostasis recovery in patients with early proliferative diabetic retinopathy.
文摘Background:This study evaluated the VIsion PERformance(VIPER)simulator’s ability to assess the functional visual performance in warfighters conducting civilian and military tasks.Methods:Thirty service members,aged 25–35 years old with a best corrected distance visual acuity(VA)better than or equal to 20/20 or logarithm of the minimum angle of resolution(logMAR)0.00,were randomized to locate and identify road signs and mock improvised explosive devices(IEDs)under either daytime conditions or with infrared imagery,with(cc)and without(sc)wearing their habitual correction.Participants also underwent binocular uncorrected(UDVA)and corrected(CDVA)visual assessment,refraction,contrast sensitivity testing and wavefront aberrometry.Results:The mean age was 28.47 years.The manifest spherical equivalent was–3.16±1.75 diopters(D),the UDVA in both eyes(OU)was logMAR 0.83±0.47,and the CDVA OU was–0.11±0.06.For VIPER,the mean difference in the detection distance(DD)for road signs ccDD vs.scDD was(76.7±52.8)m(P<0.001).The average difference in identification distance(ID)ccID vs.scID was(13.9±6.3)m(P<0.001).The mean accuracies were 83.5%and 27.9%for cc and sc,respectively(P<0.001).The regression analysis indicated that a 1.6 m change in the distance accounts for a 1%change in the accuracy(P=0.002).Without correction,a 4.1 m change accounts for a 1%change in the accuracy(P<0.001).The average IED ccDD was(29.9±8.2)m,and that for scDD was(13.2±13.6)m(P<0.001).The average IED ccID was(32.2±6.2)m and that for the scID was(7.4±10.3)m(P<0.001).The mean IED identification accuracy was 46.7 and 11.4%for cc and sc,respectively(P<0.001).Conclusions:The preliminary results reflect VIPER’s ability to assess functional visual performance when detecting and identifying signs and IEDs.Furthermore,VIPER is able to detect performance changes with and without correction.
文摘Visual and pictorial materials are extensively used in teaching listening comprehension textbooks. Although the use of still image is currently implemented in some distinguished testing systems, video test is not a popular modality due to the fact that this kind of test may result in test-takers' confusion during the test. In the present study, a sample of 80 Iranian EFL (English as a Foreign Language) students was selected to compare their performance on three different modalities of listening test: audio-only test, pictorial (listening with still image test), and visual (video) listening test. The analysis of one-way repeated measure ANOVA (Analysis of Variance) was used to compare the students' scores. The results of Bonferroni Post Hoc Test confirm that there were significant differences in scores among audio-only, pictorial, and visual tests. The results of this study highlight the greater performance of students in pictorial listening test which is statistically significant.
文摘In this paper,we introduce the design and implementation of ParaVT,which is a visual performance analysis and parallel debugging tool.In ParaVT,we propose an automated instrumentation mechanism.Based on this mechanism,ParaVT automatically analyzes the performance bottleneck of parallel applications and provides a visual user interface to monitor and analyze the performance of parallel programs.In addition,it also supports certain extensions.
文摘AIM:To determine the effects of change in light conditions on refractive error and visual functions including visual acuity,stereopsis and contrast sensitivity.METHODS:This cross-sectional study was conducted in the optometry clinic of the Shahid Beheshti School of Rehabilitation on 48 students in 2021-2022.All of them had eye health and normal visual function and could have refractive errors or not.Light intensity of 4 lx was considered equivalent to photopic light condition and light intensity of 1 lx was considered to be equivalent to mesopic light condition.The amount of refractive error was checked by auto refractometer and its changes in mesopic light condition were subjectively measured.Also,visual acuity,stereopsis and contrast sensitivity(in five spatial frequencies of 1.5,3,6,12,and 18 cycles per degree),were measured first in photopic light condition and then in mesopic light condition,by Snellen control vision chart,stereo butterfly test and the M&S technology monitor test respectively.RESULTS:In the 48 student subjects with an average age of 22.69±3.56y,mean of refractive error as sphere equivalent,visual acuity and stereopsis were-1.25±1.74 diopters,0 logMAR,44.37±13.03 seconds of arc,respectively in photopic light condition while in mesopic light was equal to-1.56±1.75 diopters,0.12±0.09 logMAR and 50.62±33.35 seconds of arc,respectively.The mean of contrast sensitivity measured at spatial frequencies of 1.5,3,6,12,and 18 cycles per degree in photopic condition was equal to 2.38±0.04,2.37±0.07,2.04±0.21,1.27±0.32,0.82±0.27 logarithm of contrast sensitivity,respectively and in mesopic lighting condition was equal to 2.34±0.12,2.30±0.16,1.84±0.28,1.02±0.28,0.63±0.24 logarithm of contrast sensitivity,respectively.Statistical analysis showed a significant difference between the two lighting conditions in all evaluated variables[refractive error(P<0.001),visual acuity(P<0.001),stereopsis(P=0.008)and contrast sensitivity(P<0.001)].CONCLUSION:The refractive error of the student subjects in mesopic light condition change towards myopia,and its amount is clinically significant.Also,the examination and comparison of the factors of visual acuity,stereopsis and contrast sensitivity in these two lighting conditions show that the decrease in brightness level to the mesopic level causes a decrease in the aforementioned visual functions.
基金supported by the Guangdong Basic and Applied Basic Research Foundation No.2021A1515110958National Natural Science Foundation of China No.62202215+1 种基金SYLU introduced high-level talents scientific research support plan,Chongqing University Innovation Research Group(CXQT21019)Chongqing Talents Project(CQYC201903048)。
文摘In visible light positioning systems,some scholars have proposed target tracking algorithms to balance the relationship among positioning accuracy,real-time performance,and robustness.However,there are still two problems:(1)When the captured LED disappears and the uncertain LED reappears,existing tracking algorithms may recognize the landmark in error;(2)The receiver is not always able to achieve positioning under various moving statuses.In this paper,we propose an enhanced visual target tracking algorithm to solve the above problems.First,we design the lightweight recognition/demodulation mechanism,which combines Kalman filtering with simple image preprocessing to quickly track and accurately demodulate the landmark.Then,we use the Gaussian mixture model and the LED color feature to enable the system to achieve positioning,when the receiver is under various moving statuses.Experimental results show that our system can achieve high-precision dynamic positioning and improve the system’s comprehensive performance.