BACKGROUND Aseptic acetabular loosening can result from various factors that can be categorized into groups:patient-related,surgeon-related and implant-related.We present a case of a 63-year-old patient who at first u...BACKGROUND Aseptic acetabular loosening can result from various factors that can be categorized into groups:patient-related,surgeon-related and implant-related.We present a case of a 63-year-old patient who at first underwent a total hip arthro-plasty(THA)using a metal-on-metal bearing due to hip arthrosis.Follow-up visits revealed no complications after the procedure.Two years after the THA,acetabular component loosening occurred due to subsequent trauma of the opposite hip,necessitating a revision THA using a ceramic-on-ceramic bearing.CASE SUMMARY We aim to illustrate a rare case where the primary reason for undergoing THA revision was not only incomplete bone graft incorporation but also improper limb load distribution.Following the revision arthroplasty,a 9-year follow-up visit revealed improvements in all evaluation measures on questionnaire compared to the state before surgery:Harris Hip Score(before surgery:15;after surgery:95),Western Ontario and McMaster Universities Arthritis Index(before surgery:96;after surgery:0),and Visual Analogue Scale(before surgery:10;after surgery:1).CONCLUSION Opposite-hip trauma caused a weight transfer to the limb after a THA procedure.This process led to a stress shielding effect,resulting in acetabular component loosening.展开更多
[Objective] This study was conducted to explore the effects of deep loos- ening on soil structure and the activity of maize root system, to provide a theoreti- cal basis for the efficient and rational use of water res...[Objective] This study was conducted to explore the effects of deep loos- ening on soil structure and the activity of maize root system, to provide a theoreti- cal basis for the efficient and rational use of water resources. [Method] Three differ- ent loosening treatments for maize in ridges were performed in field trials as fol- lows: conventional ridge tillage, loosening the cm in spring (deep loosening in spring), and depth of 30 cm in autumn (deep loosening in soils between rows to a depth of 30 oosening the soils between rows to a autumn). Then the soil properties and the development of root system were measured to evaluate the effects of different loosening methods. [Result] Soil compactness was significantly reduced after deep loosening in spring, There were significant differences in soil compactness in 0-20 cm depth and soil bulk density in 0-40 cm depth between deep loosening in spring and deep loosening in autumn, deep loosening in spring and conventional ridge tillage. The soil water holding capacity was also significantly different between the two deep loosening treatments and conventional ridge tillage. Moreover, the root ac- tive absorption area of maize of deep loosening in spring was higher than that of conventionai ridge tillage. [Conclusion] Deep loosening can reduce soil compactness, bulk density, and improve soil water holding capacity, soil water content and the root activity of maize. Deep loosening in spring is better in soil improvement be- cause spring is closer to the growth period of crops than autumn. So, deep loosen- ing is conducive to the improvement of soil compactness and structure.展开更多
AIM To assess serum levels of RANK-ligand(RANKL) and osteoprotegerin(OPG) as biomarkers for periprosthetic joint infection(PJI) and compare their accuracy with standard tests.METHODS One hundred and twenty patients pr...AIM To assess serum levels of RANK-ligand(RANKL) and osteoprotegerin(OPG) as biomarkers for periprosthetic joint infection(PJI) and compare their accuracy with standard tests.METHODS One hundred and twenty patients presenting with a painful total knee or hip arthroplasty with indication for surgical revision were included in this prospective clinical trial. Based on standard diagnostics(joint aspirate, microbiological, and histological samples) and Musculoskeletal Infection Society consensus classification,patients were categorized into PJI, aseptic loosening,and control groups. Implant loosening was assessed radiographically and intraoperatively. Preoperative serum samples were collected and analyzed for RANKL, OPG, calcium, phosphate, alkaline phosphatase(AP), and the bone-specific subform of AP(b AP). Statistical analysis was carried out, testing for significant differences between the three groups and between stable and loose implants. RESULTS All three groups were identical in regards to age, gender, and joint distribution. No statistically significant differences in the serum concentration of RANKL(P = 0.16) and OPG(P = 0.45) were found between aseptic loosening and PJI, with a trend towards lower RANKL concentrations and higher OPG concentrations in the PJI group. The RANKL/OPG ratio was significant for the comparison between PJI and non-PJI(P = 0.005). A ratio > 60 ruled out PJI in all cases(specificity: 100%, 95%CI: 89, 11% to 100.0%) but only 30% of non-PJI patients crossed this threshold. The positive predictive value remained poor at any cut-off. In the differentiation between stable and loose implants, none of the parameters measured(calcium, phosphate, AP, and b AP) showed a significant difference, and only AP and b AP measurements showed a tendency towards higher values in the loosened group(with P = 0.09 for AP and P = 0.19 for b AP). CONCLUSION Lower RANKL and higher OPG concentrations could be detected in PJI, without statistical significance.展开更多
Existing research on the competitive failure relationship,failure mechanism,and influencing factors of bolt loosening and fatigue under different preloads is insufficient.This study analyzes the competitive failure re...Existing research on the competitive failure relationship,failure mechanism,and influencing factors of bolt loosening and fatigue under different preloads is insufficient.This study analyzes the competitive failure relationship between bolt loosening and fatigue under composite excitation through competitive failure tests of bolt loosening and fatigue under different preloads.The results indicated that the failure mode of the bolt is only related to the load ratio(R)and is unrelated to the initial preload and excitation amplitude,which only determine the failure life of the bolt.The small axial loads of composite excitation can restrain bolt failure,and the significant degree of this restraining effect is differ-ent for different preloads.Subsequently,a fracture analysis of the bolt was performed to verify the competitive failure relationship of the bolt from a microscopic perspective,and the competitive failure mechanism of the bolt was deter-mined.Based on the findings,we propose a calculation equation for the optimal preload of 8.8 grade high-strength bolts that can serve as a reference for engineering applications.展开更多
BACKGROUND The majority of published data report the results of biomechanical tests of various design pedicle screw performance.The clinical relevance and relative contribution of screw design to instrumentation stabi...BACKGROUND The majority of published data report the results of biomechanical tests of various design pedicle screw performance.The clinical relevance and relative contribution of screw design to instrumentation stability have been insufficiently studied.AIM To estimate the contribution of screw design to rate of pedicle screw loosening in patients with degenerative diseases of the lumbar spine.METHODS This study is a prospective evaluation of 175 patients with degenerative diseases and instability of the lumbar spine segments.Participants underwent spinal instrumentation employing pedicle screws with posterior only or transforaminal interbody fusion.Follow-up was for 18 mo.Patients with signs of pedicle screw loosening on computed tomography were registered;logistic regression analysis was used to identify the factors that influenced the rate of loosening.RESULTS Parameters included in the analysis were screw geometry,type of thread,external and internal screw diameter and helical pitch,bone density in Hounsfield units,number of levels fused,instrumentation without anterior support,laminectomy,and unilateral and bilateral total facet joint resection.The rate of screw loosening decreased with the increment in outer diameter,decrease in core diameter and helical pitch.The rate of screw loosening correlated positively with the number of fused levels and decreasing bone density.Bilateral facet joint removal significantly favored pedicle screw loosening.The influence of other factors was insignificant.CONCLUSION Screw parameters had a significant impact on the loosening rate along with bone quality characteristics,the number of levels fused and the extensiveness of decompression.The significance of the influence of screw parameters was comparable to those of patient-and surgery-related factors.Pedicle screw loosening was influenced by helical pitch,inner and outer diameter,but screw geometry and thread type were insignificant factors.展开更多
Bolted connections are commonly used in aerospace structures.Once the bolts on the aircraft are damaged or loose,the consequence will be disastrous.Therefore,monitoring bolt loosening is especially required.However,pe...Bolted connections are commonly used in aerospace structures.Once the bolts on the aircraft are damaged or loose,the consequence will be disastrous.Therefore,monitoring bolt loosening is especially required.However,periodic manual inspection costs much money and time.And it is very difficult to achieve multi-point monitoring for many bolted structures in an aircraft.Therefore,a low-cost,reliable detection method based on wireless sensor networks is presented.The reed switch is selected as a sensor for bolt loosening monitor.The chip PT2262 and PT2272are chosen as hardware codec chip for multi-point placement.A wireless transmitter and receiver circuit is designed on 315 MHz frequency.The codec chip and the wireless transmission are triggered by the reed switches.Bolt loosening is detected by the receiving terminal and indicated by light and sound alarms.The wireless transmitter and the receiver circuit are tested and the monitoring system is verified by experiments.The results show that bolt loosening can be effectively detected within 300 m.The developed sensor network is expected to solve multi-point bolt detection problems and provide a low-cost and reliable monitoring technology.展开更多
In low rectal cancer surgery,the section of rectum destal to the lower tumor maigin is relaxed and lengthened after fully isolation of the organ. This would facilitate the adoption of anus saving operation.Before and ...In low rectal cancer surgery,the section of rectum destal to the lower tumor maigin is relaxed and lengthened after fully isolation of the organ. This would facilitate the adoption of anus saving operation.Before and after fully isolation of the rectum in low ratal cancer surgery, the distance between the lower tumor margin and the anorectal line was measured by the same rectuscope introduced through the anus.The two results were compared .The average lengthening was less than 1 cm if the lower tumor marginanorectal line distance was 5 cm.It was 1─2 cm if the lower tumor margin-anorectal distance was 6 cm.It was more than 2 cm if the distance was 7─9 cm.The loosening and lengthening of the rectal canal was related to the presence of lymphnode metastasis and the skill of the operator.The lengthening was also influenced by the body build of the patient,involvement of the rectal circumference and the Dukes stage. Modified Park's operation,trans abdominosacral resection with anastormosis of rectum,and anterior resection on transpubic approach are indicated for those in whom the lower tumor margin-anorectal line distance was 5 cm The rectectomy-anastomosis in the abdominal cavity(Dixon's operation)is indicated for those in whom the lower tumor margin-anorectal line was 6 cm.If manual anastomosis is difficult,stapling device may be used. The anus saving resection is easy if the distance was 7─9 cm.展开更多
BACKGROUND Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.CASE SUMMARY We describe t...BACKGROUND Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.CASE SUMMARY We describe the case of a 78-year-old woman who had recurrence of back pain 5 years after lumbar spine posterior decompression and instrumented fusion.Lumbar spine radiographs showed hardware loosening and magnetic resonance imaging showed adjacent segment disease.Revision surgery revealed evidence of metallosis intraoperatively.CONCLUSION Spinal metallosis can present several years after instrumentation.Radiography and computed tomography may demonstrate hardware loosening secondary to metallosis.Blood metal concentrations associated with spinal metallosis have yet to be established.Hence,metallosis is still an intraoperative and histopathological diagnosis.The presence of metallosis after spinal instrumentation likely indicates a more complex underlying problem:Pseudarthrosis,failure to address sagittal balance,infection,and cross-threading of set screws.Hence,identifying metallosis is important,but initiating treatment promptly for symptomatic implant loosening is of greater paramount.展开更多
Objective To observe IL-1B,IL-6 and TNF-a level change of the joint fluid in the experimental knee joint degeneration and the effect of the local loosening therapy.Methods Thirty rabbits were divided into 3 groups at ...Objective To observe IL-1B,IL-6 and TNF-a level change of the joint fluid in the experimental knee joint degeneration and the effect of the local loosening therapy.Methods Thirty rabbits were divided into 3 groups at random:ten in the normal contrast group,ten in the blank model group and ten in the loosening therapy group to observe the IL-1B,IL-6 and TNF-a change of the joint fluid before and after the treatment in each group.Result IL-1B,IL-6 and TNF-a level in the blank model group was obviously higher than that in the normal group.(P<0.05).IL-1B,IL-6 and TNF-a level in the treatment group was obviously lower than that in the normal group.(P<0.05).Conclusions 1)IL-1B,IL-6 and TNF-a level of the joint fluid in the blank model group was obviously higher than that in the normal group.2)Loosening soft tissues of the knees can improve IL-1B,IL-6 and TNF-a level of the joint fluid.展开更多
A novel technique of electroforming with orbital moving cathode was carried out for the fabrication of non-rotating thin-walled parts.This technique features a large number of insulating and insoluble hard particles a...A novel technique of electroforming with orbital moving cathode was carried out for the fabrication of non-rotating thin-walled parts.This technique features a large number of insulating and insoluble hard particles as a real-time polishing to the cathode.When cathode moves,hard particles polish its surface and provide the nickel non-rotating parts with near-mirror finishing.Morphology,microstructure,surface roughness and micro hardness of deposits fabricated by novel method were studied in contrast with the sample produced by traditional electroforming methods.Theoretical analysis and experimental results showed that the novel technique could effectively remove the hydrogen bubbles and nodules,disturb the crystal nucleation,and refine the grains of layer.The mechanical properties were significantly improved over traditional method.The micro-hardness of the layer was in a uniform distribution ranging from 345 HV to 360 HV.It was confirmed that this technique had practical significance to non-rotating thin-walled parts.展开更多
Recently,reform on charges against dangerous driving has stirred up debate among the public.A new stipulation by China’s Supreme People’s court which took effect on May 1 granted judges the discretion to decide whet...Recently,reform on charges against dangerous driving has stirred up debate among the public.A new stipulation by China’s Supreme People’s court which took effect on May 1 granted judges the discretion to decide whether someone caught driving under the influence of alcohol should be held criminal responsible by taking into account how drunk the person is,road conditions and the seriousness of damages.展开更多
文摘BACKGROUND Aseptic acetabular loosening can result from various factors that can be categorized into groups:patient-related,surgeon-related and implant-related.We present a case of a 63-year-old patient who at first underwent a total hip arthro-plasty(THA)using a metal-on-metal bearing due to hip arthrosis.Follow-up visits revealed no complications after the procedure.Two years after the THA,acetabular component loosening occurred due to subsequent trauma of the opposite hip,necessitating a revision THA using a ceramic-on-ceramic bearing.CASE SUMMARY We aim to illustrate a rare case where the primary reason for undergoing THA revision was not only incomplete bone graft incorporation but also improper limb load distribution.Following the revision arthroplasty,a 9-year follow-up visit revealed improvements in all evaluation measures on questionnaire compared to the state before surgery:Harris Hip Score(before surgery:15;after surgery:95),Western Ontario and McMaster Universities Arthritis Index(before surgery:96;after surgery:0),and Visual Analogue Scale(before surgery:10;after surgery:1).CONCLUSION Opposite-hip trauma caused a weight transfer to the limb after a THA procedure.This process led to a stress shielding effect,resulting in acetabular component loosening.
基金Supported by National Maize Industry Technology System(CARS-02-38)Science and Technology Development Project of Jilin Province(LFGC14308)Special Fund for Scientific Research in the Public Interest(201303125-03)
文摘[Objective] This study was conducted to explore the effects of deep loos- ening on soil structure and the activity of maize root system, to provide a theoreti- cal basis for the efficient and rational use of water resources. [Method] Three differ- ent loosening treatments for maize in ridges were performed in field trials as fol- lows: conventional ridge tillage, loosening the cm in spring (deep loosening in spring), and depth of 30 cm in autumn (deep loosening in soils between rows to a depth of 30 oosening the soils between rows to a autumn). Then the soil properties and the development of root system were measured to evaluate the effects of different loosening methods. [Result] Soil compactness was significantly reduced after deep loosening in spring, There were significant differences in soil compactness in 0-20 cm depth and soil bulk density in 0-40 cm depth between deep loosening in spring and deep loosening in autumn, deep loosening in spring and conventional ridge tillage. The soil water holding capacity was also significantly different between the two deep loosening treatments and conventional ridge tillage. Moreover, the root ac- tive absorption area of maize of deep loosening in spring was higher than that of conventionai ridge tillage. [Conclusion] Deep loosening can reduce soil compactness, bulk density, and improve soil water holding capacity, soil water content and the root activity of maize. Deep loosening in spring is better in soil improvement be- cause spring is closer to the growth period of crops than autumn. So, deep loosen- ing is conducive to the improvement of soil compactness and structure.
基金Supported by The"Deutsche Arthrose-Hilfe e.V.",No.P192-A362-2009-12
文摘AIM To assess serum levels of RANK-ligand(RANKL) and osteoprotegerin(OPG) as biomarkers for periprosthetic joint infection(PJI) and compare their accuracy with standard tests.METHODS One hundred and twenty patients presenting with a painful total knee or hip arthroplasty with indication for surgical revision were included in this prospective clinical trial. Based on standard diagnostics(joint aspirate, microbiological, and histological samples) and Musculoskeletal Infection Society consensus classification,patients were categorized into PJI, aseptic loosening,and control groups. Implant loosening was assessed radiographically and intraoperatively. Preoperative serum samples were collected and analyzed for RANKL, OPG, calcium, phosphate, alkaline phosphatase(AP), and the bone-specific subform of AP(b AP). Statistical analysis was carried out, testing for significant differences between the three groups and between stable and loose implants. RESULTS All three groups were identical in regards to age, gender, and joint distribution. No statistically significant differences in the serum concentration of RANKL(P = 0.16) and OPG(P = 0.45) were found between aseptic loosening and PJI, with a trend towards lower RANKL concentrations and higher OPG concentrations in the PJI group. The RANKL/OPG ratio was significant for the comparison between PJI and non-PJI(P = 0.005). A ratio > 60 ruled out PJI in all cases(specificity: 100%, 95%CI: 89, 11% to 100.0%) but only 30% of non-PJI patients crossed this threshold. The positive predictive value remained poor at any cut-off. In the differentiation between stable and loose implants, none of the parameters measured(calcium, phosphate, AP, and b AP) showed a significant difference, and only AP and b AP measurements showed a tendency towards higher values in the loosened group(with P = 0.09 for AP and P = 0.19 for b AP). CONCLUSION Lower RANKL and higher OPG concentrations could be detected in PJI, without statistical significance.
基金Supported by National Natural Science Foundation of China(Grant No.51675446)Independent Subject of State Key Laboratory of Traction Power(Grant No.2019TPL-T13).
文摘Existing research on the competitive failure relationship,failure mechanism,and influencing factors of bolt loosening and fatigue under different preloads is insufficient.This study analyzes the competitive failure relationship between bolt loosening and fatigue under composite excitation through competitive failure tests of bolt loosening and fatigue under different preloads.The results indicated that the failure mode of the bolt is only related to the load ratio(R)and is unrelated to the initial preload and excitation amplitude,which only determine the failure life of the bolt.The small axial loads of composite excitation can restrain bolt failure,and the significant degree of this restraining effect is differ-ent for different preloads.Subsequently,a fracture analysis of the bolt was performed to verify the competitive failure relationship of the bolt from a microscopic perspective,and the competitive failure mechanism of the bolt was deter-mined.Based on the findings,we propose a calculation equation for the optimal preload of 8.8 grade high-strength bolts that can serve as a reference for engineering applications.
文摘BACKGROUND The majority of published data report the results of biomechanical tests of various design pedicle screw performance.The clinical relevance and relative contribution of screw design to instrumentation stability have been insufficiently studied.AIM To estimate the contribution of screw design to rate of pedicle screw loosening in patients with degenerative diseases of the lumbar spine.METHODS This study is a prospective evaluation of 175 patients with degenerative diseases and instability of the lumbar spine segments.Participants underwent spinal instrumentation employing pedicle screws with posterior only or transforaminal interbody fusion.Follow-up was for 18 mo.Patients with signs of pedicle screw loosening on computed tomography were registered;logistic regression analysis was used to identify the factors that influenced the rate of loosening.RESULTS Parameters included in the analysis were screw geometry,type of thread,external and internal screw diameter and helical pitch,bone density in Hounsfield units,number of levels fused,instrumentation without anterior support,laminectomy,and unilateral and bilateral total facet joint resection.The rate of screw loosening decreased with the increment in outer diameter,decrease in core diameter and helical pitch.The rate of screw loosening correlated positively with the number of fused levels and decreasing bone density.Bilateral facet joint removal significantly favored pedicle screw loosening.The influence of other factors was insignificant.CONCLUSION Screw parameters had a significant impact on the loosening rate along with bone quality characteristics,the number of levels fused and the extensiveness of decompression.The significance of the influence of screw parameters was comparable to those of patient-and surgery-related factors.Pedicle screw loosening was influenced by helical pitch,inner and outer diameter,but screw geometry and thread type were insignificant factors.
基金supported by the National Natural Science Foundation of China (Nos.51105209,61401211, 51175267)the China Postdoctoral Science Foundation (Nos.2012M511760, 2013T60540)+3 种基金the Specialized Research Fund for the Doctoral Program of Higher Education (No.20113219120005)the Jiangsu Province Science and Technology Support Program (No.BE2012034)the Ministry of Science & Technology of Zhengzhou (No. 131PPTGG425)the Zijin Intelligent Program of Nanjing University of Science and Technology (No. 2013ZJ0203)
文摘Bolted connections are commonly used in aerospace structures.Once the bolts on the aircraft are damaged or loose,the consequence will be disastrous.Therefore,monitoring bolt loosening is especially required.However,periodic manual inspection costs much money and time.And it is very difficult to achieve multi-point monitoring for many bolted structures in an aircraft.Therefore,a low-cost,reliable detection method based on wireless sensor networks is presented.The reed switch is selected as a sensor for bolt loosening monitor.The chip PT2262 and PT2272are chosen as hardware codec chip for multi-point placement.A wireless transmitter and receiver circuit is designed on 315 MHz frequency.The codec chip and the wireless transmission are triggered by the reed switches.Bolt loosening is detected by the receiving terminal and indicated by light and sound alarms.The wireless transmitter and the receiver circuit are tested and the monitoring system is verified by experiments.The results show that bolt loosening can be effectively detected within 300 m.The developed sensor network is expected to solve multi-point bolt detection problems and provide a low-cost and reliable monitoring technology.
文摘In low rectal cancer surgery,the section of rectum destal to the lower tumor maigin is relaxed and lengthened after fully isolation of the organ. This would facilitate the adoption of anus saving operation.Before and after fully isolation of the rectum in low ratal cancer surgery, the distance between the lower tumor margin and the anorectal line was measured by the same rectuscope introduced through the anus.The two results were compared .The average lengthening was less than 1 cm if the lower tumor marginanorectal line distance was 5 cm.It was 1─2 cm if the lower tumor margin-anorectal distance was 6 cm.It was more than 2 cm if the distance was 7─9 cm.The loosening and lengthening of the rectal canal was related to the presence of lymphnode metastasis and the skill of the operator.The lengthening was also influenced by the body build of the patient,involvement of the rectal circumference and the Dukes stage. Modified Park's operation,trans abdominosacral resection with anastormosis of rectum,and anterior resection on transpubic approach are indicated for those in whom the lower tumor margin-anorectal line distance was 5 cm The rectectomy-anastomosis in the abdominal cavity(Dixon's operation)is indicated for those in whom the lower tumor margin-anorectal line was 6 cm.If manual anastomosis is difficult,stapling device may be used. The anus saving resection is easy if the distance was 7─9 cm.
文摘BACKGROUND Spinal metallosis is a rare complication following spinal instrumentation whereby an inflammatory response to the metal implants results in the development of granulomatous tissue.CASE SUMMARY We describe the case of a 78-year-old woman who had recurrence of back pain 5 years after lumbar spine posterior decompression and instrumented fusion.Lumbar spine radiographs showed hardware loosening and magnetic resonance imaging showed adjacent segment disease.Revision surgery revealed evidence of metallosis intraoperatively.CONCLUSION Spinal metallosis can present several years after instrumentation.Radiography and computed tomography may demonstrate hardware loosening secondary to metallosis.Blood metal concentrations associated with spinal metallosis have yet to be established.Hence,metallosis is still an intraoperative and histopathological diagnosis.The presence of metallosis after spinal instrumentation likely indicates a more complex underlying problem:Pseudarthrosis,failure to address sagittal balance,infection,and cross-threading of set screws.Hence,identifying metallosis is important,but initiating treatment promptly for symptomatic implant loosening is of greater paramount.
基金Project(99JJy2081)supported by the Natural Science Foundation of Hunan Province
文摘Objective To observe IL-1B,IL-6 and TNF-a level change of the joint fluid in the experimental knee joint degeneration and the effect of the local loosening therapy.Methods Thirty rabbits were divided into 3 groups at random:ten in the normal contrast group,ten in the blank model group and ten in the loosening therapy group to observe the IL-1B,IL-6 and TNF-a change of the joint fluid before and after the treatment in each group.Result IL-1B,IL-6 and TNF-a level in the blank model group was obviously higher than that in the normal group.(P<0.05).IL-1B,IL-6 and TNF-a level in the treatment group was obviously lower than that in the normal group.(P<0.05).Conclusions 1)IL-1B,IL-6 and TNF-a level of the joint fluid in the blank model group was obviously higher than that in the normal group.2)Loosening soft tissues of the knees can improve IL-1B,IL-6 and TNF-a level of the joint fluid.
基金Funded partly by the National Natural Science Foundation of China(No.50975143)the Aviation Science Funds,China (No.2009ZE52048)
文摘A novel technique of electroforming with orbital moving cathode was carried out for the fabrication of non-rotating thin-walled parts.This technique features a large number of insulating and insoluble hard particles as a real-time polishing to the cathode.When cathode moves,hard particles polish its surface and provide the nickel non-rotating parts with near-mirror finishing.Morphology,microstructure,surface roughness and micro hardness of deposits fabricated by novel method were studied in contrast with the sample produced by traditional electroforming methods.Theoretical analysis and experimental results showed that the novel technique could effectively remove the hydrogen bubbles and nodules,disturb the crystal nucleation,and refine the grains of layer.The mechanical properties were significantly improved over traditional method.The micro-hardness of the layer was in a uniform distribution ranging from 345 HV to 360 HV.It was confirmed that this technique had practical significance to non-rotating thin-walled parts.
文摘Recently,reform on charges against dangerous driving has stirred up debate among the public.A new stipulation by China’s Supreme People’s court which took effect on May 1 granted judges the discretion to decide whether someone caught driving under the influence of alcohol should be held criminal responsible by taking into account how drunk the person is,road conditions and the seriousness of damages.