Aimed at the disadvantages of secondary damage to oil layers caused by the conventional bull-heading water control technique, a thermo-sensitive temporary plugging agent for water control was synthesized by water solu...Aimed at the disadvantages of secondary damage to oil layers caused by the conventional bull-heading water control technique, a thermo-sensitive temporary plugging agent for water control was synthesized by water solution polymerization and applied in the field with a new secondary temporary plugging technique. The optimization and performance evaluation of thermo-sensitive temporary plugging agent were carried out through laboratory experiments. The optimized formula is as follows:(6%-8%) acrylamide +(0.08%-0.12%) ammonium persulfate +(1.5%-2.0%) sepiolite +(0.5%-0.8%) polyethylene glycol diacrylate. The thermo-sensitive temporary plugging agent is suitable for formation temperatures of 70-90 ?C, it has high temporary plugging strength(5-40 k Pa), controllable degradation time(1-15 d), the apparent viscosity after degradation of less than 100 m Pa?S and the permeability recovery value of simulated cores of more than 95%. Based on the research results, secondary temporary plugging technique was used in a horizontal well in the Jidong Oilfield. After treatment, the well saw a drop of water cut to 27%, and now it has a water cut of 67%, its daily increased oil production was 4.8 t, and the cumulative oil increment was 750 t, demonstrating that the technique worked well in controlling water production and increasing oil production.展开更多
Plugging agent treatment and acid stimulation have completely different mechanisms for improving injection profiles. In this paper, a hybrid procedure is introduced to reduce the damage of the plugging agent to low a...Plugging agent treatment and acid stimulation have completely different mechanisms for improving injection profiles. In this paper, a hybrid procedure is introduced to reduce the damage of the plugging agent to low and medium permeability zones and the penetration radius of acid into high permeability zones. The procedure is: First inject plugging agent to block high permeability zones, and then inject acid to remove plugging agent damage from the low and medium permeability zones and stimulate them. To perform this procedure successfully, three kinds of plugging agents, namely strong strength plugging agent for the wells with fractures or high permeability streaks, weak gel for those with thick layer in which serious heterogeneity exists, temporary plugging agent for those in which the absorption ability of high permeability zones needs maintaining, were screened out for use in different reservoirs. Several acid systems were evaluated to be compatible with the three kinds of plugging agents. The objectives of this paper are:(1)To show the screen results about the compatible plugging agent and acid; 2 To show how to optimize the operation process;(3)To tell some experience gained ( ) from the oilfield applications of this technique. From Jan. 2001 to Dec. 2002, 46 operations using this procedure were carried out in Weicheng and Mazhai Oilfields of SINOPEC. Results show that the average benefit/cost ratio is over 3.5. Experience acquired from these applications was summarized in the paper.展开更多
基金Supported by the National Key Special Science and Technology Project(2016ZX05015-002)PetroChina Key Special Science and Technology Project(2016E-0104)
文摘Aimed at the disadvantages of secondary damage to oil layers caused by the conventional bull-heading water control technique, a thermo-sensitive temporary plugging agent for water control was synthesized by water solution polymerization and applied in the field with a new secondary temporary plugging technique. The optimization and performance evaluation of thermo-sensitive temporary plugging agent were carried out through laboratory experiments. The optimized formula is as follows:(6%-8%) acrylamide +(0.08%-0.12%) ammonium persulfate +(1.5%-2.0%) sepiolite +(0.5%-0.8%) polyethylene glycol diacrylate. The thermo-sensitive temporary plugging agent is suitable for formation temperatures of 70-90 ?C, it has high temporary plugging strength(5-40 k Pa), controllable degradation time(1-15 d), the apparent viscosity after degradation of less than 100 m Pa?S and the permeability recovery value of simulated cores of more than 95%. Based on the research results, secondary temporary plugging technique was used in a horizontal well in the Jidong Oilfield. After treatment, the well saw a drop of water cut to 27%, and now it has a water cut of 67%, its daily increased oil production was 4.8 t, and the cumulative oil increment was 750 t, demonstrating that the technique worked well in controlling water production and increasing oil production.
文摘Plugging agent treatment and acid stimulation have completely different mechanisms for improving injection profiles. In this paper, a hybrid procedure is introduced to reduce the damage of the plugging agent to low and medium permeability zones and the penetration radius of acid into high permeability zones. The procedure is: First inject plugging agent to block high permeability zones, and then inject acid to remove plugging agent damage from the low and medium permeability zones and stimulate them. To perform this procedure successfully, three kinds of plugging agents, namely strong strength plugging agent for the wells with fractures or high permeability streaks, weak gel for those with thick layer in which serious heterogeneity exists, temporary plugging agent for those in which the absorption ability of high permeability zones needs maintaining, were screened out for use in different reservoirs. Several acid systems were evaluated to be compatible with the three kinds of plugging agents. The objectives of this paper are:(1)To show the screen results about the compatible plugging agent and acid; 2 To show how to optimize the operation process;(3)To tell some experience gained ( ) from the oilfield applications of this technique. From Jan. 2001 to Dec. 2002, 46 operations using this procedure were carried out in Weicheng and Mazhai Oilfields of SINOPEC. Results show that the average benefit/cost ratio is over 3.5. Experience acquired from these applications was summarized in the paper.