期刊文献+
共找到19,081篇文章
< 1 2 250 >
每页显示 20 50 100
Simulation of the SMILE Soft X-ray Imager response to a southward interplanetary magnetic field turning 被引量:1
1
作者 Andrey Samsonov Graziella Branduardi-Raymont +3 位作者 Steven Sembay Andrew Read David Sibeck Lutz Rastaetter 《Earth and Planetary Physics》 EI CSCD 2024年第1期39-46,共8页
The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magne... The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magnetic field turning and produce SXI count maps with a 5-minute integration time.By making assumptions about the magnetopause shape,we find the magnetopause standoff distance from the count maps and compare it with the one obtained directly from the magnetohydrodynamic(MHD)simulation.The root mean square deviations between the reconstructed and MHD standoff distances do not exceed 0.2 RE(Earth radius)and the maximal difference equals 0.24 RE during the 25-minute interval around the southward turning. 展开更多
关键词 magnetOPAUSE magnetic reconnection solar wind charge exchange southward interplanetary magnetic field numerical modeling Solar wind magnetosphere Ionosphere Link Explorer(SMILE) Soft X-ray Imager
下载PDF
Optimization of magnetic field design for Hall thrusters based on a genetic algorithm
2
作者 谭睿 杭观荣 王平阳 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期82-92,共11页
Magnetic field design is essential for the operation of Hall thrusters.This study focuses on utilizing a genetic algorithm to optimize the magnetic field configuration of SPT70.A 2D hybrid PIC-DSMC and channel-wall er... Magnetic field design is essential for the operation of Hall thrusters.This study focuses on utilizing a genetic algorithm to optimize the magnetic field configuration of SPT70.A 2D hybrid PIC-DSMC and channel-wall erosion model are employed to analyze the plume divergence angle and wall erosion rate,while a Farady probe measurement and laser profilometry system are set up to verify the simulation results.The results demonstrate that the genetic algorithm contributes to reducing the divergence angle of the thruster plumes and alleviating the impact of high-energy particles on the discharge channel wall,reducing the erosion by 5.5%and 2.7%,respectively.Further analysis indicates that the change from a divergent magnetic field to a convergent magnetic field,combined with the upstream shift of the ionization region,contributes to the improving the operation of the Hall thruster. 展开更多
关键词 magnetic field design genetic algorithm divergence angle erosion of discharge channel convergent magnetic field
下载PDF
Probing the peripheral self-generated magnetic field distribution in laser-plasma magnetic reconnection with Martin-Puplett interferometer polarimeter
3
作者 张雅芃 姚嘉文 +2 位作者 刘正东 马作霖 仲佳勇 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期129-134,共6页
Magnetic reconnection of the self-generated magnetic fields in laser-plasma interaction is an important laboratory method for modeling high-energy density astronomical and astrophysical phenomena.We use the Martin-Pup... Magnetic reconnection of the self-generated magnetic fields in laser-plasma interaction is an important laboratory method for modeling high-energy density astronomical and astrophysical phenomena.We use the Martin-Puplett interferometer(MPI)polarimeter to probe the peripheral magnetic fields generated in the common magnetic reconnection configuration,two separated coplanar plane targets,in laser-target interaction.We introduce a new method that can obtain polarization information from the interference pattern instead of the sinusoidal function fitting of the intensity.A bidirectional magnetic field is observed from the side view,which is consistent with the magneto-hydro-dynamical(MHD)simulation results of self-generated magnetic field reconnection.We find that the cancellation of reverse magnetic fields after averaging and integration along the observing direction could reduce the magnetic field strength by one to two orders of magnitude.It indicates that imaging resolution can significantly affect the accuracy of measured magnetic field strength. 展开更多
关键词 laser-plasma experiment POLARIMETER self-generated magnetic field magnetic reconnection
下载PDF
Analytical computation of magnetic field in coil-dominated superconducting quadrupole magnets based on racetrack coils
4
作者 Chuang Shen Ying-Shun Zhu Fu-San Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期119-135,共17页
Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufact... Currently,three types of superconducting quadrupole magnets are used in particle accelerators:cos 2θ,CCT,and serpentine.However,all three coil configurations have complex spatial geometries,which make magnet manufacturing and strain-sensitive superconductor applications difficult.Compared with the three existing quadrupole coils,the racetrack quadrupole coil has a simple shape and manufacturing process,but there have been few theoretical studies.In this paper,the two-dimensional and three-dimensional analytical expressions for the magnetic field in coil-dominated racetrack superconducting quadrupole magnets are presented.The analytical expressions of the field harmonics and gradient are fully resolved and depend only on the geometric parameters of the coil and current density.Then,a genetic algorithm is applied to obtain a solution for the coil geometry parameters with field harmonics on the order of 10^(-4).Finally,considering the practical engineering needs of the accelerator interaction region,electromagnetic design examples of racetrack quadrupole magnets with high gradients,large apertures,and small apertures are described,and the application prospects of racetrack quadrupole coils are analyzed. 展开更多
关键词 Superconducting quadrupole magnet Racetrack coil Multipole field Genetic algorithm magnetic design
下载PDF
Revolutionizing plasmonic platform via magnetic field-assisted confined ultrafast laser deposition of high-density,uniform,and ultrafine nanoparticle arrays
5
作者 Jin Xu Lingfeng Wang +5 位作者 Peilin Yang Haoqing Jiang Huai Zheng Licong An Xingtao Liu Gary J Cheng 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2024年第3期428-438,共11页
The remarkable capabilities of 2D plasmonic surfaces in controlling optical waves havegarnered significant attention.However,the challenge of large-scale manufacturing of uniform,well-aligned,and tunable plasmonic sur... The remarkable capabilities of 2D plasmonic surfaces in controlling optical waves havegarnered significant attention.However,the challenge of large-scale manufacturing of uniform,well-aligned,and tunable plasmonic surfaces has hindered their industrialization.To address this,we present a groundbreaking tunable plasmonic platform design achieved throughmagnetic field(MF)assisted ultrafast laser direct deposition in air.Through precise control of metal nanoparticles(NPs),with cobalt(Co)serving as the model material,employing an MF,and fine-tuning ultrafast laser parameters,we have effectively converted coarse and non-uniform NPs into densely packed,uniform,and ultrafine NPs(~3 nm).This revolutionary advancement results in the creation of customizable plasmonic‘hot spots,’which play a pivotal role insurface-enhanced Raman spectroscopy(SERS)sensors.The profound impact of this designable plasmonic platform lies in its close association with plasmonic resonance and energyenhancement.When the plasmonic nanostructures resonate with incident light,they generate intense local electromagnetic fields,thus vastly increasing the Raman scattering signal.This enhancement leads to an outstanding 2–18 fold boost in SERS performance and unparalleled sensing sensitivity down to 10^(-10)M.Notably,the plasmonic platform also demonstratesrobustness,retaining its sensing capability even after undergoing 50 cycles of rinsing andre-loading of chemicals.Moreover,this work adheres to green manufacturing standards,making it an efficient and environmentally friendly method for customizing plasmonic‘hot spots’inSERS devices.Our study not only achieves the formation of high-density,uniform,and ultrafine NP arrays on a tunable plasmonic platform but also showcases the profound relation betweenplasmonic resonance and energy enhancement.The outstanding results observed in SERS sensors further emphasize the immense potential of this technology for energy-relatedapplications,including photocatalysis,photovoltaics,and clean water,propelling us closer to a sustainable and cleaner future. 展开更多
关键词 magnetic field manipulation laser deposition metasurface SERS
下载PDF
Reconstruction of poloidal magnetic field profiles in field-reversed configurations with machine learning in laser-driven ion-beam trace probe
6
作者 徐栩涛 徐田超 +4 位作者 肖池阶 张祖煜 何任川 袁瑞鑫 许平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期83-87,共5页
The diagnostic of poloidal magnetic field(B_(p))in field-reversed configuration(FRC),promising for achieving efficient plasma confinement due to its highβ,is a huge challenge because B_(p)is small and reverses around... The diagnostic of poloidal magnetic field(B_(p))in field-reversed configuration(FRC),promising for achieving efficient plasma confinement due to its highβ,is a huge challenge because B_(p)is small and reverses around the core region.The laser-driven ion-beam trace probe(LITP)has been proven to diagnose the B_(p)profile in FRCs recently,whereas the existing iterative reconstruction approach cannot handle the measurement errors well.In this work,the machine learning approach,a fast-growing and powerful technology in automation and control,is applied to B_(p)reconstruction in FRCs based on LITP principles and it has a better performance than the previous approach.The machine learning approach achieves a more accurate reconstruction of B_(p)profile when 20%detector errors are considered,15%B_(p)fluctuation is introduced and the size of the detector is remarkably reduced.Therefore,machine learning could be a powerful support for LITP diagnosis of the magnetic field in magnetic confinement fusion devices. 展开更多
关键词 FRC LITP poloidal magnetic field diagnostics machine learning
下载PDF
Customized modulation on plasma uniformity by non-uniform magnetic field in capacitively coupled plasma
7
作者 王森 张权治 +2 位作者 马方方 Maksudbek YUSUPOV 王友年 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期79-87,共9页
A two-dimensional fluid model based on COMSOL Multiphysics is developed to investigate the modulation of static magnetic field on plasma homogeneity in a capacitively coupled plasma(CCP)chamber. To generate a static m... A two-dimensional fluid model based on COMSOL Multiphysics is developed to investigate the modulation of static magnetic field on plasma homogeneity in a capacitively coupled plasma(CCP)chamber. To generate a static magnetic field, direct current is applied to a circular coil located at the top of the chamber. By adjusting the magnetic field's configuration, which is done by altering the coil current and position, both the plasma uniformity and density can be significantly modulated. In the absence of the magnetic field, the plasma density exhibits an inhomogeneous distribution characterized by higher values at the plasma edge and lower values at the center. The introduction of a magnetic field generated by coils results in a significant increase in electron density near the coils. Furthermore, an increase in the sets of coils improves the uniformity of the plasma. By flexibly adjusting the positions of the coils and the applied current,a substantial enhancement in overall uniformity can be achieved. These findings demonstrate the feasibility of using this method for achieving uniform plasma densities in industrial applications. 展开更多
关键词 COMSOL capacitively coupled plasma plasma uniformity magnetic field
下载PDF
Spin-polarized pairing induced by the magnetic field in the Bernal bilayer graphene
8
作者 黄妍 周涛 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期650-654,共5页
Recent experimental findings have demonstrated the occurrence of superconductivity in Bernal bilayer graphene when induced by a magnetic field.In this study,we conduct a theoretical investigation of the potential pair... Recent experimental findings have demonstrated the occurrence of superconductivity in Bernal bilayer graphene when induced by a magnetic field.In this study,we conduct a theoretical investigation of the potential pairing symmetry within this superconducting system.By developing a theoretical model,we primarily calculate the free energy of the system with p+ip-wave parallel spin pairing,p+ip-wave anti-parallel spin pairing and d+i d-wave pairing symmetry.Our results confirm that the magnetic field is indeed essential for generating the superconductivity.We discover that the p+ip-wave parallel spin pairing leads to a lower free energy for the system.The numerical calculations of the energy band structure,zero-energy spectral function and density of states for each of the three pairing symmetries under consideration show a strong consistency with the free energy results. 展开更多
关键词 SUPERCONDUCTIVITY magnetic field induction pairing symmetry Bernal bilayer graphene
下载PDF
Effect of external magnetic field on the instability of THz plasma waves in nanoscale graphene field-effect transistors
9
作者 张丽萍 孙宗耀 +1 位作者 李佳妮 苏俊燕 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期683-689,共7页
The instability of plasma waves in the channel of field-effect transistors will cause the electromagnetic waves with THz frequency.Based on a self-consistent quantum hydrodynamic model,the instability of THz plasmas w... The instability of plasma waves in the channel of field-effect transistors will cause the electromagnetic waves with THz frequency.Based on a self-consistent quantum hydrodynamic model,the instability of THz plasmas waves in the channel of graphene field-effect transistors has been investigated with external magnetic field and quantum effects.We analyzed the influence of weak magnetic fields,quantum effects,device size,and temperature on the instability of plasma waves under asymmetric boundary conditions numerically.The results show that the magnetic fields,quantum effects,and the thickness of the dielectric layer between the gate and the channel can increase the radiation frequency.Additionally,we observed that increase in temperature leads to a decrease in both oscillation frequency and instability increment.The numerical results and accompanying images obtained from our simulations provide support for the above conclusions. 展开更多
关键词 graphene field-effect transistors external magnetic field radiation frequency instability increment
下载PDF
Effect of antenna helicity on discharge characteristics of helicon plasma under a divergent magnetic field
10
作者 孙萌 徐晓芳 +3 位作者 王陈文 尹贤轶 陈强 张海宝 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期50-59,共10页
The characteristics of the blue core phenomenon observed in a divergent magnetic field helicon plasma are investigated using two different helical antennas, namely right-handed and lefthanded helical antennas. The mod... The characteristics of the blue core phenomenon observed in a divergent magnetic field helicon plasma are investigated using two different helical antennas, namely right-handed and lefthanded helical antennas. The mode transition, discharge image, spatial profiles of plasma density and electron temperature are diagnosed using a Langmuir probe, a Nikon D90 camera,an intensified charge-coupled device camera and an optical emission spectrometer, respectively.The results demonstrated that the blue core phenomenon appeared in the upstream region of the discharge tube at a fixed magnetic field under both helical antennas. However, it is more likely to appear in a right-handed helical antenna, in which the plasma density and ionization rate of the helicon plasma are higher. The spatial profiles of the plasma density and electron temperature are also different in both axial and radial directions for these two kinds of helical antenna. The wavelength calculated based on the dispersion relation of the bounded whistler wave is consistent with the order of magnitude of plasma length. It is proved that the helicon plasma is part of the wave mode discharge mechanism. 展开更多
关键词 helicon plasma non-uniform magnetic field helical antenna blue core discharge mechanism
下载PDF
Acetaminophen overdose-induced acute liver injury can be alleviated by static magnetic field
11
作者 Han-Xiao Chen Xin-Yu Wang +11 位作者 Biao Yu Chuan-Lin Feng Guo-Feng Cheng Lei Zhang Jun-Jun Wang Ying Wang Ruo-Wen Guo Xin-Miao Ji Wen-Jing Xie Wei-Li Chen Chao Song Xin Zhang 《Zoological Research》 SCIE CSCD 2024年第3期478-490,共13页
Acetaminophen(APAP),the most frequently used mild analgesic and antipyretic drug worldwide,is implicated in causing 46%of all acute liver failures in the USA and between 40%and 70%in Europe.The predominant pharmacolog... Acetaminophen(APAP),the most frequently used mild analgesic and antipyretic drug worldwide,is implicated in causing 46%of all acute liver failures in the USA and between 40%and 70%in Europe.The predominant pharmacological intervention approved for mitigating such overdose is the antioxidant N-acetylcysteine(NAC);however,its efficacy is limited in cases of advanced liver injury or when administered at a late stage.In the current study,we discovered that treatment with a moderate intensity static magnetic field(SMF)notably reduced the mortality rate in mice subjected to high-dose APAP from 40%to 0%,proving effective at both the initial liver injury stage and the subsequent recovery stage.During the early phase of liver injury,SMF markedly reduced APAPinduced oxidative stress,free radicals,and liver damage,resulting in a reduction in multiple oxidative stress markers and an increase in the antioxidant glutathione(GSH).During the later stage of liver recovery,application of vertically downward SMF increased DNA synthesis and hepatocyte proliferation.Moreover,the combination of NAC and SMF significantly mitigated liver damage induced by high-dose APAP and increased liver recovery,even 24 h post overdose,when the effectiveness of NAC alone substantially declines.Overall,this study provides a noninvasive non-pharmaceutical tool that offers dual benefits in the injury and repair stages following APAP overdose.Of note,this tool can work as an alternative to or in combination with NAC to prevent or minimize liver damage induced by APAP,and potentially other toxic overdoses. 展开更多
关键词 ACETAMINOPHEN Acute liver injury Static magnetic fields Oxidative stress DNA synthesis
下载PDF
Model of self-generated magnetic field generation from relativistic laser interaction with solid targets
12
作者 严睿 邹德滨 +9 位作者 赵娜 杨晓虎 蒋祥瑞 胡理想 徐新荣 周泓宇 余同普 卓红斌 邵福球 银燕 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期511-517,共7页
Generation of self-generated annular magnetic fields at the rear side of a solid target driven by relativistic laser pulse is investigated by using theoretical analysis and particle-in-cell simulations.The spatial str... Generation of self-generated annular magnetic fields at the rear side of a solid target driven by relativistic laser pulse is investigated by using theoretical analysis and particle-in-cell simulations.The spatial strength distribution of magnetic fields can be accurately predicted by calculating the net flow caused by the superposition of source flow and return flow of hot electrons.The theoretical model established shows good agreement with the simulation results,indicating that the magnetic-field strength scales positively to the temperature of hot electrons.This provides us a way to improve the magnetic-field generation by using a micro-structured plasma grating in front of the solid target.Compared with that for a common flat target,hot electrons can be effectively heated with the well-designed grating size,leading to a stronger magnetic field.The spatial distribution of magnetic fields can be modulated by optimizing the grating period and height as well as the incident angle of the laser pulse. 展开更多
关键词 self-generated magnetic field laser solid-target interaction micro-structured plasma grating
下载PDF
An Investigation into Forced Convection of a Nanofluid Flowing in a Rectangular Microchannel under the Influence of a Magnetic Field
13
作者 Muataz S.Alhassan Ameer A.Alameri +4 位作者 Andrés Alexis Ramírez-Coronel I.B.Sapaev Azher M.Abed David-Juan Ramos-Huallpartupa Rahman S.Zabibah 《Fluid Dynamics & Materials Processing》 EI 2024年第2期311-323,共13页
In line with recent studies,where it has been shown that nanofluids containing graphene have a stronger capacity to boost the heat transfer coefficient with respect to ordinary nanofluids,experiments have been conducted ... In line with recent studies,where it has been shown that nanofluids containing graphene have a stronger capacity to boost the heat transfer coefficient with respect to ordinary nanofluids,experiments have been conducted using water with cobalt ferrite/graphene nanoparticles.In particular,a circular channel made of copper subjected to a constant heatflux has been considered.As nanoparticles are sensitive to the presence of a magneticfield,different conditions have been examined,allowing both the strength and the frequency of such afield to span relatively wide ranges and assuming different concentrations of nanoparticles.According to thefindings,the addition of nanoparticles to thefluid causes its rotation speed to increase by a factor of two,whereas ultraviolet radiation plays a negligible role.The amount of time required to attain the maximum rotation speed of the nanofluid and the Nusselt number have been measured under both constant and alternating magneticfields for a ferrofluid with a concentration of 0.5%and atflow Reynolds number of 550 and 1750. 展开更多
关键词 Nano fluid rectengular tube magnetic field
下载PDF
Stress corrosion cracking behavior of buried oil and gas pipeline steel under the coexistence of magnetic field and sulfate-reducing bacteria
14
作者 Jian-Yu He Fei Xie +3 位作者 Dan Wang Guang-Xin Liu Ming Wu Yue Qin 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期1320-1332,共13页
Magnetic field and microorganisms are important factors influencing the stress corrosion cracking(SCC)of buried oil and gas pipelines. Once SCC occurs in buried pipelines, it will cause serious hazards to the soil env... Magnetic field and microorganisms are important factors influencing the stress corrosion cracking(SCC)of buried oil and gas pipelines. Once SCC occurs in buried pipelines, it will cause serious hazards to the soil environment. The SCC behavior of X80 pipeline steel under the magnetic field and sulfate-reducing bacteria(SRB) environment was investigated by immersion tests, electrochemical tests, and slow strain rate tensile(SSRT) tests. The results showed that the corrosion and SCC sensitivity of X80 steel decreased with increasing the magnetic field strength in the sterile environment. The SCC sensitivity was higher in the biotic environment inoculated with SRB, but it also decreased with increasing magnetic field strength, which was due to the magnetic field reduces microbial activity and promotes the formation of dense film layer. This work provided theoretical guidance on the prevention of SCC in pipeline steel under magnetic field and SRB coexistence. 展开更多
关键词 magnetic field Sulfate-reducing bacteria Film layer Stress corrosion cracking Oil and gas pipelines
下载PDF
Magnetic Field Controllable Photocurrent Properties in BiFe_(0.9)Ni_(0.1)O_(3)/La_(0.7)Sr_(0.3)MnO_(3) Laminate Thin Film
15
作者 Guanzhong Huo Ke Wang +5 位作者 Qingying Ye Shuiyuan Chen Chao Su Yuxiang Zhang Guilin Chen Zhigao Huang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第2期381-388,共8页
This paper reports a multifunctional magnetic-photoelectric laminate device based on the integration of spintronic material(La_(0.7)Sr_(0.3)MnO_(3))and multiferroic(Ni-doped BiFeO_(3)),in which the repeatable modulati... This paper reports a multifunctional magnetic-photoelectric laminate device based on the integration of spintronic material(La_(0.7)Sr_(0.3)MnO_(3))and multiferroic(Ni-doped BiFeO_(3)),in which the repeatable modulation effect on the photoelectric properties were achieved by applying external magnetic fields.More obviously,photocurrent density(J)of the laminate was largely enhanced,the change rate of J up to 287.6%is obtained.This sensing function effect should be attributed to the low-field magnetoresistance effect in perovskite manganite and the scattering of spin photoelectron in multiferroic material.The laminate perfectly combines the functions of sensor and controller,which can not only reflect the intensity of environmental magnetic field,but also modulate the photoelectric conversion performance.This work provides an alternative and facile way to realize multi-degree-of-freedom control for photoelectric conversion performances and lastly miniaturize multifunction device. 展开更多
关键词 bismuth ferrite low-field magnetoresistance effect magnetic field modulation perovskite manganite PHOTOCURRENT
下载PDF
Effects of vacuum magnetic field region on the compact torus trajectory in a tokamak plasma
16
作者 董期龙 张洁 +28 位作者 兰涛 肖持进 庄革 陈晨 周永康 吴捷 龙婷 聂林 卢鹏程 王天雄 邬佳仁 邓鹏 汪兴康 柏泽琪 黄玉华 李杰 薛雷 阿迪力江 毛文哲 周楚 刘阿娣 吴征威 谢锦林 丁卫星 刘万东 陈伟 钟武律 许敏 段旭如 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期23-39,共17页
The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tok... The trajectory of the compact torus(CT)within a tokamak discharge is crucial to fueling.In this study,we developed a penetration model with a vacuum magnetic field region to accurately determine CT trajectories in tokamak discharges.This model was used to calculate the trajectory and penetration parameters of CT injections by applying both perpendicular and tangential injection schemes in both HL-2A and ITER tokamaks.For perpendicular injection along the tokamak's major radius direction from the outboard,CTs with the same injection parameters exhibited a 0.08 reduction in relative penetration depth when injected into HL-2A and a 0.13reduction when injected into ITER geometry when considering the vacuum magnetic field region compared with cases where this region was not considered.In addition,we proposed an optimization method for determining the CT's initial injection velocity to accurately calculate the initial injection velocity of CTs for central fueling in tokamaks.Furthermore,this paper discusses schemes for the tangential injection of CT into tokamak discharges.The optimal injection angle and CT magnetic moment direction for injection into both HL-2A and ITER were determined through numerical simulations.Finally,the kinetic energy loss occurring when the CT penetrated the vacuum magnetic field region in ITER was reduced byΔEk=975.08 J by optimizing the injection angle for the CT injected into ITER.These results provide valuable insights for optimizing injection angles in fusion experiments.Our model closely represents actual experimental scenarios and can assist the design of CT parameters. 展开更多
关键词 compact torus central fueling vacuum magnetic field region penetration mechanism optimization parameters
下载PDF
Suppression of stimulated Brillouin and Raman scatterings using an alternating frequency laser and transverse magnetic fields
17
作者 程瑞锦 李晓旬 +11 位作者 王清 刘德基 黄卓明 吕帅宇 周远志 张舒童 李雪铭 陈祖杰 王强 刘占军 曹莉华 郑春阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期545-553,共9页
A novel scheme to suppress both stimulated Brillouin scattering(SBS) and stimulated Raman scattering(SRS) by combining an alternating frequency(AF) laser and a transverse magnetic field is proposed. The AF laser allow... A novel scheme to suppress both stimulated Brillouin scattering(SBS) and stimulated Raman scattering(SRS) by combining an alternating frequency(AF) laser and a transverse magnetic field is proposed. The AF laser allows the laser frequency to change discretely and alternately over time. The suppression of SBS is significant as long as the AF difference is greater than the linear growth rate of SBS or the alternating time of the laser frequency is shorter than the linear growth time of SBS. However, the AF laser proves ineffective in suppressing SRS, which usually has a much higher linear growth rate than SBS. To remedy that, a transverse magnetic field is included to suppress the SRS instability. The electrons trapped in the electron plasma waves(EPWs) of SRS can be accelerated by the surfatron mechanism in a transverse magnetic field and eventually detrapped. While continuously extracting energy from EPWs, the EPWs are dissipated and the kinetic inflation of SRS is suppressed. The one-dimensional particle-in-cell simulation results show that both SBS and SRS can be effectively suppressed by combining the AF laser with a transverse magnetic field with tens of Tesla. The total reflectivity can be dramatically reduced by more than one order of magnitude. These results provide a potential reference for controlling SBS and SRS under the related parameters of inertial confinement fusion. 展开更多
关键词 stimulated Brillouin scattering stimulated Raman scattering alternating frequency laser transverse magnetic field
下载PDF
Effect of interplanetary magnetic field B_(x)on the polar electrojets as observed by CHAMP and Swarm satellites
18
作者 Hui Wang ChengZhi Wang YunFang Zhong 《Earth and Planetary Physics》 EI CAS CSCD 2024年第2期382-390,共9页
Based on 16 years of magnetic field observations from CHAMP and Swarm satellites,this study investigates the influence of the Interplanetary Magnetic Field(IMF)Bx component on the location and peak current density of ... Based on 16 years of magnetic field observations from CHAMP and Swarm satellites,this study investigates the influence of the Interplanetary Magnetic Field(IMF)Bx component on the location and peak current density of the polar electrojets(PEJs).We find that the IMF Bx displays obvious local time,seasonal,and hemispherical effects on the PEJs,as follows:(1)Compared to other local times,its influence is weakest at dawn and dusk.(2)In the midnight sectors of both hemispheres,the IMF Bx tends to amplify the westward PEJ when it is<0 in the Northern Hemisphere and when it is>0 in the Southern Hemisphere;this effect is relatively stronger in the local winter hemisphere.(3)At noontime,the IMF Bx intensifies the eastward current when it is<0 in the Northern Hemisphere;in the Southern Hemisphere when it is>0,it reduces the westward current;this effect is notably more prominent in the local summer hemisphere.(4)Moreover,the noontime eastward current shifts towards higher latitudes,while the midnight westward current migrates towards lower latitudes when IMF Bx is<0 in the Northern Hemisphere and when it is>0 in the Southern Hemisphere. 展开更多
关键词 polar electrojet interplanetary magnetic field Bx local time asymmetry hemispheric difference
下载PDF
High-resolution imaging of magnetic fields of banknote anti-counterfeiting strip using fiber diamond probe
19
作者 赵旭彤 何飞越 +5 位作者 薛雅文 马文豪 殷筱晗 夏圣开 曾明菁 杜关祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期720-727,共8页
Counterfeiting of modern banknotes poses a significant challenge,prompting the use of various preventive measures.One such measure is the magnetic anti-counterfeiting strip.However,due to its inherent weak magnetic pr... Counterfeiting of modern banknotes poses a significant challenge,prompting the use of various preventive measures.One such measure is the magnetic anti-counterfeiting strip.However,due to its inherent weak magnetic properties,visualizing its magnetic distribution has been a longstanding challenge.In this work,we introduce an innovative method by using a fiber optic diamond probe,a highly sensitive quantum sensor designed specifically for detecting extremely weak magnetic fields.We employ this probe to achieve high-resolution imaging of the magnetic fields associated with the RMB 50denomination anti-counterfeiting strip.Additionally,we conduct computer simulations by using COMSOL Multiphysics software to deduce the potential geometric characteristics and material composition of the magnetic region within the anti-counterfeiting strip.The findings and method presented in this study hold broader significance,extending the RMB 50 denomination to various denominations of the Chinese currency and other items that employ magnetic anti-counterfeiting strips.These advances have the potential to significantly improve and promote security measures in order to prevent the banknotes from being counterfeited. 展开更多
关键词 banknote anti-counterfeiting strip nitrogen-vacancy(NV)centers magnetic field imaging numerical simulation
下载PDF
Diagnosing ratio of electron density to collision frequency of plasma surrounding scaled model in a shock tube using low-frequency alternating magnetic field phase shift
20
作者 吴明兴 谢楷 +3 位作者 刘艳 徐晗 张宝 田得阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期519-530,共12页
A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic... A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic field through the plasma to directly measure the ratio of the plasma loop average electron density to collision frequency.An equivalent circuit model is used to analyze the relationship of the phase shift of the magnetic field component of LF electromagnetic waves with the plasma electron density and collision frequency.The applicable range of the LF method on a given plasma scale is analyzed.The upper diagnostic limit for the ratio of the electron density(unit:m^(-3))to collision frequency(unit:Hz)exceeds 1×10^(11),enabling an electron density to exceed 1×10^(20)m^(-3)and a collision frequency to be less than 1 GHz.In this work,the feasibility of using the LF phase shift to implement the plasma diagnosis is also assessed.Diagnosis experiments on shock tube equipment are conducted by using both the electrostatic probe method and LF method.By comparing the diagnostic results of the two methods,the inversion results are relatively consistent with each other,thereby preliminarily verifying the feasibility of the LF method.The ratio of the electron density to the collision frequency has a relatively uniform distribution during the plasma stabilization.The LF diagnostic path is a loop around the model,which is suitable for diagnosing the plasma that surrounds the model.Finally,the causes of diagnostic discrepancy between the two methods are analyzed.The proposed method provides a new avenue for diagnosing high-density enveloping plasma. 展开更多
关键词 low-frequency alternating magnetic field phase shift shock-tube plasma diagnosis electron density collision frequency
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部