A cascaded system of electrical discharges (Non-thermal plasma), catalyst andadsorption process was investigated for the removal of oxides of nitrogen (NO_x) and carbonmonoxide (CO) from a Diesel engine raw exhaust. T...A cascaded system of electrical discharges (Non-thermal plasma), catalyst andadsorption process was investigated for the removal of oxides of nitrogen (NO_x) and carbonmonoxide (CO) from a Diesel engine raw exhaust. The three processes were separately studied first,and then the cascaded processes, namely plasma-catalyst and plasma-adsorbent, were investigated. Inthis paper main emphasis was laid on the effect of carbonaceous soot oxidation on the plasmatreatment process. While the cascaded plasma-catalyst process exhibits a higher CO removal, thecascaded plasma-adsorbent process exhibits a higher NO_x removal. The experiments were conductedunder no-load. The plasma and adsorbent reactors were kept at room temperature throughout theexperiment while the catalyst reactor was kept at 200℃ / 300℃.展开更多
文摘A cascaded system of electrical discharges (Non-thermal plasma), catalyst andadsorption process was investigated for the removal of oxides of nitrogen (NO_x) and carbonmonoxide (CO) from a Diesel engine raw exhaust. The three processes were separately studied first,and then the cascaded processes, namely plasma-catalyst and plasma-adsorbent, were investigated. Inthis paper main emphasis was laid on the effect of carbonaceous soot oxidation on the plasmatreatment process. While the cascaded plasma-catalyst process exhibits a higher CO removal, thecascaded plasma-adsorbent process exhibits a higher NO_x removal. The experiments were conductedunder no-load. The plasma and adsorbent reactors were kept at room temperature throughout theexperiment while the catalyst reactor was kept at 200℃ / 300℃.