The performance of data-driven models relies heavily on the amount and quality of training samples, so it might deteriorate significantly in the regions where samples are scarce. The objective of this paper is to deve...The performance of data-driven models relies heavily on the amount and quality of training samples, so it might deteriorate significantly in the regions where samples are scarce. The objective of this paper is to develop an online SVR model updating strategy to track the change in the process characteristics efficiently with affordable computational burden. This is achieved by adding a new sample that violates the Karush–Kuhn–Tucker conditions of the existing SVR model and by deleting the old sample that has the maximum distance with respect to the newly added sample in feature space. The benefits offered by such an updating strategy are exploited to develop an adaptive model-based control scheme, where model updating and control task perform alternately.The effectiveness of the adaptive controller is demonstrated by simulation study on a continuous stirred tank reactor. The results reveal that the adaptive MPC scheme outperforms its non-adaptive counterpart for largemagnitude set point changes and variations in process parameters.展开更多
In this paper, we have rigorously analyzed a model to find the effective control strategies on the transmission dynamics of a vector-borne disease. It is proved that the global dynamics of the disease are completely d...In this paper, we have rigorously analyzed a model to find the effective control strategies on the transmission dynamics of a vector-borne disease. It is proved that the global dynamics of the disease are completely determined by the basic reproduction number. The numerical simulations (using MatLab and Maple) of the model reveal that the precautionary measures at the aquatic and adult stage decrease the number of new cases of dengue virus. Numerical simulation indicates that if we take the precautionary measures seriously then it would be more effective than even giving the treatment to the infected individuals.展开更多
In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence i...In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence it is necessary to design a system that regulates output parameters, such as voltage and frequency, and thereby provides a constant voltage and frequency output from the wind energy conversion system. Matrix converter is used in the proposed solution as the main power conditioner as a more efficient alternative when compared to traditional back-back converter structure. To control the output voltage, a vector modulation based refined control structure is used. A power tracker is included to maximize the mechanical output power of the turbine. Over current protection and clamp circuit input protection have been introduced to protect the system from over current. It reduces the spikes generated at the output of the converter. The designed system is capable of supplying an output voltage of constant frequency and amplitude within the expected ranges of input during the operation. The matrix converter control using direct modulation method, modified Venturini modulation method and vector modulation method was simulated, the results were compared and it was inferred that vector modulation method was superior to the other two methods. With the proposed technique, voltage transfer ratio and harmonic profile have been improved compared to the other two modulation techniques. The behaviour of the system is corroborated by MATLAB Simulink, and hardware is realized using an FPGA controller. Experimental results are found to be matching with the simulation results.展开更多
功率同步控制和矢量控制均是多端柔性直流输电系统(multi-terminal voltage source converter based high voltage direct current transmission,VSC-MTDC)中换流站的可选控制方式。与更加常用的矢量控制方式相比,功率同步控制方式的...功率同步控制和矢量控制均是多端柔性直流输电系统(multi-terminal voltage source converter based high voltage direct current transmission,VSC-MTDC)中换流站的可选控制方式。与更加常用的矢量控制方式相比,功率同步控制方式的原理与同步发电机类似,进而显现了相近的控制特性,更适用于与交流电网的弱连接,有利于交流电网的功角和频率稳定性,但其缺点是在直流侧故障下,换流站会出现较大的直流电压波动,恶化系统的动态特性。为了使换流站能够在不同的电网运行工况下匹配最合适的控制方式,提出一种可切换的控制策略,实现了在同一换流站中功率同步和矢量控制方式并存,并可依据需求实现无扰动自动切换。最后以PSCAD中搭建的三端交直流系统为例,演示和验证了同步切换控制策略的可行性。展开更多
基金Supported by the National Basic Research Program of China(2012CB720500)Postdoctoral Science Foundation of China(2013M541964)Fundamental Research Funds for the Central Universities(13CX05021A)
文摘The performance of data-driven models relies heavily on the amount and quality of training samples, so it might deteriorate significantly in the regions where samples are scarce. The objective of this paper is to develop an online SVR model updating strategy to track the change in the process characteristics efficiently with affordable computational burden. This is achieved by adding a new sample that violates the Karush–Kuhn–Tucker conditions of the existing SVR model and by deleting the old sample that has the maximum distance with respect to the newly added sample in feature space. The benefits offered by such an updating strategy are exploited to develop an adaptive model-based control scheme, where model updating and control task perform alternately.The effectiveness of the adaptive controller is demonstrated by simulation study on a continuous stirred tank reactor. The results reveal that the adaptive MPC scheme outperforms its non-adaptive counterpart for largemagnitude set point changes and variations in process parameters.
文摘In this paper, we have rigorously analyzed a model to find the effective control strategies on the transmission dynamics of a vector-borne disease. It is proved that the global dynamics of the disease are completely determined by the basic reproduction number. The numerical simulations (using MatLab and Maple) of the model reveal that the precautionary measures at the aquatic and adult stage decrease the number of new cases of dengue virus. Numerical simulation indicates that if we take the precautionary measures seriously then it would be more effective than even giving the treatment to the infected individuals.
文摘In this paper, a hybrid control strategy for a matrix converter fed wind energy conversion system is presented. Since the wind speed may vary, output parameters like power, frequency and voltage may fluctuate. Hence it is necessary to design a system that regulates output parameters, such as voltage and frequency, and thereby provides a constant voltage and frequency output from the wind energy conversion system. Matrix converter is used in the proposed solution as the main power conditioner as a more efficient alternative when compared to traditional back-back converter structure. To control the output voltage, a vector modulation based refined control structure is used. A power tracker is included to maximize the mechanical output power of the turbine. Over current protection and clamp circuit input protection have been introduced to protect the system from over current. It reduces the spikes generated at the output of the converter. The designed system is capable of supplying an output voltage of constant frequency and amplitude within the expected ranges of input during the operation. The matrix converter control using direct modulation method, modified Venturini modulation method and vector modulation method was simulated, the results were compared and it was inferred that vector modulation method was superior to the other two methods. With the proposed technique, voltage transfer ratio and harmonic profile have been improved compared to the other two modulation techniques. The behaviour of the system is corroborated by MATLAB Simulink, and hardware is realized using an FPGA controller. Experimental results are found to be matching with the simulation results.
文摘功率同步控制和矢量控制均是多端柔性直流输电系统(multi-terminal voltage source converter based high voltage direct current transmission,VSC-MTDC)中换流站的可选控制方式。与更加常用的矢量控制方式相比,功率同步控制方式的原理与同步发电机类似,进而显现了相近的控制特性,更适用于与交流电网的弱连接,有利于交流电网的功角和频率稳定性,但其缺点是在直流侧故障下,换流站会出现较大的直流电压波动,恶化系统的动态特性。为了使换流站能够在不同的电网运行工况下匹配最合适的控制方式,提出一种可切换的控制策略,实现了在同一换流站中功率同步和矢量控制方式并存,并可依据需求实现无扰动自动切换。最后以PSCAD中搭建的三端交直流系统为例,演示和验证了同步切换控制策略的可行性。