Various land use and land cover(LULC)products have been produced over the past decade with the development of remote sensing technology.Despite the differences in LULC classification schemes,there is a lack of researc...Various land use and land cover(LULC)products have been produced over the past decade with the development of remote sensing technology.Despite the differences in LULC classification schemes,there is a lack of research on assessing the accuracy of their application to croplands in a unified framework.Thus,this study evaluated the spatial and area accuracies of cropland classification for four commonly used global LULC products(i.e.,MCD12Q1V6,GlobCover2009,FROM-GLC and GlobeLand30)based on the harmonised FAO criterion,and quantified the relationships between four factors(i.e.,slope,elevation,field size and crop system)and cropland classification agreement.The validation results indicated that MCD12Q1 and GlobeLand30 performed well in cropland classification regarding spatial consistency,with overall accuracies of 94.90 and 93.52%,respectively.The FROMGLC showed the worst performance,with an overall accuracy of 83.17%.Overlaying the cropland generated by the four global LULC products,we found the proportions of complete agreement and disagreement were 15.51 and 44.72% for the cropland classification,respectively.High consistency was mainly observed in the Northeast China Plain,the Huang-Huai-Hai Plain and the northern part of the Middle-lower Yangtze Plain,China.In contrast,low consistency was detected primarily on the eastern edge of the northern and semiarid region,the Yunnan-Guizhou Plateau and southern China.Field size was the most important factor for mapping cropland.For area accuracy,compared with China Statistical Yearbook data at the provincial scale,the accuracies of different products in descending order were:GlobeLand30,FROM-GLC,MCD12Q1,and GlobCover2009.The cropland classification schemes mainly caused large area deviations among the four products,and they also resulted in the different ranks of spatial accuracy and area accuracy among the four products.Our results can provide valuable suggestions for selecting cropland products at the national or provincial scale and help cropland mapping and reconstruction,which is essential for food security and crop management,so they can also contribute to achieving the Sustainable Development Goals issued by the United Nations.展开更多
BACKGROUND As one of the fatal diseases with high incidence,lung cancer has seriously endangered public health and safety.Elderly patients usually have poor self-care and are more likely to show a series of psychologi...BACKGROUND As one of the fatal diseases with high incidence,lung cancer has seriously endangered public health and safety.Elderly patients usually have poor self-care and are more likely to show a series of psychological problems.AIM To investigate the effectiveness of the initial check,information exchange,final accuracy check,reaction(IIFAR)information care model on the mental health status of elderly patients with lung cancer.METHODS This study is a single-centre study.We randomly recruited 60 elderly patients with lung cancer who attended our hospital from January 2021 to January 2022.These elderly patients with lung cancer were randomly divided into two groups,with the control group taking the conventional propaganda and education and the observation group taking the IIFAR information care model based on the conventional care protocol.The differences in psychological distress,anxiety and depression,life quality,fatigue,and the locus of control in psychology were compared between these two groups,and the causes of psychological distress were analyzed.RESULTS After the intervention,Distress Thermometer,Hospital Anxiety and Depression Scale(HADS)for anxiety and the HADS for depression,Revised Piper’s Fatigue Scale,and Chance Health Locus of Control scores were lower in the observation group compared to the pre-intervention period in the same group and were significantly lower in the observation group compared to those of the control group(P<0.05).After the intervention,Quality of Life Questionnaire Core 30(QLQ-C30),Internal Health Locus of Control,and Powerful Others Health Locus of Control scores were significantly higher in the observation and the control groups compared to the pre-intervention period in their same group,and QLQ-C30 scores were significantly higher in the observation group compared to those of the control group(P<0.05).CONCLUSION The IIFAR information care model can help elderly patients with lung cancer by reducing their anxiety and depression,psychological distress,and fatigue,improving their tendencies on the locus of control in psychology,and enhancing their life qualities.展开更多
BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for...BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice.展开更多
Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,an...Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,and IEEE Xplore databases until September 2023.Cross-sectional and case-control studies on diagnostic accuracy of bowel sound analysis for IBS were identified.We estimated the pooled sensitivity,specificity,positive likelihood ratio,negative likeli-hood ratio,and diagnostic odds ratio with a 95% confidence interval(CI),and plotted a summary receiver operat-ing characteristic curve and evaluated the area under the curve.Results Four studies were included.The pooled diagnostic sensitivity,specificity,positive likelihood ratio,nega-tive likelihood ratio,and diagnostic odds ratio were 0.94(95%CI,0.87‒0.97),0.89(95%CI,0.81‒0.94),8.43(95%CI,4.81‒14.78),0.07(95%CI,0.03‒0.15),and 118.86(95%CI,44.18‒319.75),respectively,with an area under the curve of 0.97(95%CI,0.95‒0.98).Conclusions Computerized bowel sound analysis is a promising tool for IBS.However,limited high-quality data make the results'validity and applicability questionable.There is a need for more diagnostic test accuracy studies and better wearable devices for monitoring and analysis of IBS.展开更多
BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies inve...BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies investigating its accuracy has increased.However,its accuracy has not been investigated in highland populations in China.AIM To evaluate measurements recorded using the FreeStyle Libre FGM system compared with capillary blood glucose measured using the enzyme electrode method in patients with type 2 diabetes(T2D)who had migrated within 3 mo from highlands to plains.METHODS Overall,68 patients with T2D,selected from those who had recently migrated from highlands to plains(within 3 mo),were hospitalized at the Department of Endocrinology from August to October 2017 and underwent continuous glucose monitoring(CGM)with the FreeStyle Libre FGM system for 14 d.Throughout the study period,fingertip capillary blood glucose was measured daily using the enzyme electrode method(Super GL,China),and blood glucose levels were read from the scanning probe during fasting and 2 h after all three meals.Moreover,the time interval between reading the data from the scanning probe and collecting fingertip capillary blood was controlled to<5 min.The accuracy of the FGM system was evaluated according to the CGM guidelines.Subsequently,the factors influencing the mean absolute relative difference(MARD)of this system were analyzed by a multiple linear regression method.RESULTS Pearson’s correlation analysis showed that the fingertip and scanned glucose levels were positively correlated(R=0.86,P=0.00).The aggregated MARD of scanned glucose was 14.28±13.40%.Parker's error analysis showed that 99.30%of the data pairs were located in areas A and B.According to the probe wear time of the FreeStyle Libre FGM system,MARD_(1 d) and MARD_(2-14 d) were 16.55%and 14.35%,respectively(t=1.23,P=0.22).Multiple stepwise regression analysis showed that MARD did not correlate with blood glucose when the largest amplitude of glycemic excursion(LAGE)was<5.80 mmol/L but negatively correlated with blood glucose when the LAGE was≥5.80 mmol/L.CONCLUSION The FreeStyle Libre FGM system has good accuracy in patients with T2D who had recently migrated from highlands to plains.This system might be ideal for avoiding the effects of high hematocrit on blood glucose monitoring in populations that recently migrated to plains.MARD is mainly influenced by glucose levels and fluctuations,and the accuracy of the system is higher when the blood glucose fluctuation is small.In case of higher blood glucose level fluctuations,deviation in the scanned glucose levels is the highest at extremely low blood glucose levels.展开更多
BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate ...BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate magnetic resonance imaging(MRI)multisequence imaging for improving the diagnostic accuracy of adult elbow cartilage injury.METHODS A total of 60 patients diagnosed with elbow cartilage injury in our hospital from January 2020 to December 2021 were enrolled in this retrospective study.We analyzed the accuracy of conventional MRI sequences(T1-weighted imaging,T2-weighted imaging,proton density weighted imaging,and T2 star weighted image)and Three-Dimensional Coronary Imaging by Spiral Scanning(3D-CISS)in the diagnosis of elbow cartilage injury.Arthroscopy was used as the gold standard to evaluate the diagnostic effect of single and combination sequences in different injury degrees and the consistency with arthroscopy.RESULTS The diagnostic accuracy of 3D-CISS sequence was 89.34%±4.98%,the sensitivity was 90%,and the specificity was 88.33%,which showed the best performance among all sequences(P<0.05).The combined application of the whole sequence had the highest accuracy in all sequence combinations,the accuracy of mild injury was 91.30%,the accuracy of moderate injury was 96.15%,and the accuracy of severe injury was 93.33%(P<0.05).Compared with arthroscopy,the combination of all MRI sequences had the highest consistency of 91.67%,and the kappa value reached 0.890(P<0.001).CONCLUSION Combination of 3D-CISS and each sequence had significant advantages in improving MRI diagnostic accuracy of elbow cartilage injuries in adults.Multisequence MRI is recommended to ensure the best diagnosis and treatment.展开更多
The dimensional accuracy of machined parts is strongly influenced by the thermal behavior of machine tools (MT). Minimizing this influence represents a key objective for any modern manufacturing industry. Thermally in...The dimensional accuracy of machined parts is strongly influenced by the thermal behavior of machine tools (MT). Minimizing this influence represents a key objective for any modern manufacturing industry. Thermally induced positioning error compensation remains the most effective and practical method in this context. However, the efficiency of the compensation process depends on the quality of the model used to predict the thermal errors. The model should consistently reflect the relationships between temperature distribution in the MT structure and thermally induced positioning errors. A judicious choice of the number and location of temperature sensitive points to represent heat distribution is a key factor for robust thermal error modeling. Therefore, in this paper, the temperature sensitive points are selected following a structured thermomechanical analysis carried out to evaluate the effects of various temperature gradients on MT structure deformation intensity. The MT thermal behavior is first modeled using finite element method and validated by various experimentally measured temperature fields using temperature sensors and thermal imaging. MT Thermal behavior validation shows a maximum error of less than 10% when comparing the numerical estimations with the experimental results even under changing operation conditions. The numerical model is used through several series of simulations carried out using varied working condition to explore possible relationships between temperature distribution and thermal deformation characteristics to select the most appropriate temperature sensitive points that will be considered for building an empirical prediction model for thermal errors as function of MT thermal state. Validation tests achieved using an artificial neural network based simplified model confirmed the efficiency of the proposed temperature sensitive points allowing the prediction of the thermally induced errors with an accuracy greater than 90%.展开更多
Machining is as old as humanity, and changes in temperature in both the machine’s internal and external environments can be of great concern as they affect the machine’s thermal stability and, thus, the machine’s d...Machining is as old as humanity, and changes in temperature in both the machine’s internal and external environments can be of great concern as they affect the machine’s thermal stability and, thus, the machine’s dimensional accuracy. This paper is a continuation of our earlier work, which aimed to analyze the effect of the internal temperature of a machine tool as the machine is put into operation and vary the external temperature, the machine floor temperature. Some experiments are carried out under controlled conditions to study how machine tool components get heated up and how this heating up affects the machine’s accuracy due to thermally induced deviations. Additionally, another angle is added by varying the machine floor temperature. The parameters mentioned above are explored in line with the overall thermal stability of the machine tool and its dimensional accuracy. A Robodrill CNC machine tool is used. The CNC was first soaked with thermal energy by gradually raising the machine floor temperature to a certain level before putting the machine in operation. The machine was monitored, and analytical methods were deplored to evaluate thermal stability. Secondly, the machine was run idle for some time under raised floor temperature before it was put into operation. Data was also collected and analyzed. It is observed that machine thermal stability can be achieved in several ways depending on how the above parameters are joggled. This paper, in conclusion, reinforces the idea of machine tool warm-up process in conjunction with a carefully analyzed and established machine floor temperature variation for the approximation of the machine tool’s thermally stability to map the long-time behavior of the machine tool.展开更多
Objective: To analyze the accuracy of serum prealbumin levels in predicting the prognosis of patients with critical respiratory illness. Methods: Fifty patients with critical respiratory illness admitted to our hospit...Objective: To analyze the accuracy of serum prealbumin levels in predicting the prognosis of patients with critical respiratory illness. Methods: Fifty patients with critical respiratory illness admitted to our hospital from October 2022 to September 2023 were selected and divided into an observation group and a control group after condition assessment, with 25 cases in each group. The results of cholinesterase (ChE), prealbumin (PALB), albumin (ALB), aspartate aminotransferase (AST), total protein (TP), and forced expiratory volume (FEV1)/Predicted (Pred) of the two groups were measured. Results: The ChE levels of the observation group were lower than those of the control group, while the PALB and ALB levels of the observation group were higher than those of the control group (P < 0.05). The AST, TP, and FEV1 /Pred levels of the observation group were higher than those in the control group (P < 0.05). Conclusion: Serum PALB levels can be used as the main indicator for prognosis in critically ill respiratory patients.展开更多
Because the vector of angular momentum of ESG (electrostatically suspended gyroscope) maintains the fixed direction in inertial space, it may be regarded as a fixed star. The astronavigation aigorithm is used to estim...Because the vector of angular momentum of ESG (electrostatically suspended gyroscope) maintains the fixed direction in inertial space, it may be regarded as a fixed star. The astronavigation aigorithm is used to estimate the azimuth angle and the gyro constant drift in the paper. The relative errors which affect the estimation accuracy of the azimuth angle are the analysed.展开更多
A novel on-line north-seeking method based on a three-axis micro-electro-mechanical system(MEMS)gyroscope is designed.This system processes data by using a Kalman filter to calibrate the installation error of the thre...A novel on-line north-seeking method based on a three-axis micro-electro-mechanical system(MEMS)gyroscope is designed.This system processes data by using a Kalman filter to calibrate the installation error of the three-axis MEMS gyroscope in complex environment.The attitude angle updating for quaternion,based on which the attitude instrument will be rotated in real-time and the true north will be found.Our experimental platform constitutes the dual-axis electric rotary table and the attitude instrument,which is developed independently by our scientific research team.The experimental results show that the accuracy of north-seeking is higher than 1°,while the maximum root mean square error and the maximum mean absolute error are 0.906 7 and 0.910 0,respectively.The accuracy of north-seeking is much higher than the traditional method.展开更多
Background:Proprioceptive accuracy refers to the individual’s ability to perceive proprioceptive information,that is,the information referring to the actual state of the locomotor system,which originates from mechano...Background:Proprioceptive accuracy refers to the individual’s ability to perceive proprioceptive information,that is,the information referring to the actual state of the locomotor system,which originates from mechanoreceptors located in various parts of the locomotor system and from tactile receptors located in the skin.Proprioceptive accuracy appears to be an important aspect in the evaluation of sensorimotor functioning;however,no widely accepted standard assessment exists.In this systematic review,our goal was to identify and categorize different methods that are used to assess different aspects of proprioceptive accuracy.Methods:A literature search was conducted in 5 different databases(PubMed,SPORTDiscus,PsycINFO,ScienceDirect,and SpringerLink).Results:Overall,1139 scientific papers reporting 1346 methods were included in this review.The methods assess 8 different aspects of proprioception:(a)the perception of joint position,(b)movement and movement extent,(c)trajectory,(d)velocity,and the sense of(e)force,(f)muscle tension,(g)weight,and(h)size.They apply various paradigms of psychophysics(i.e.,the method of adjustment,constant stimuli,and limits).Conclusion:As the outcomes of different tasks with respect to various body parts show no associations(i.e.,proprioceptive accuracy is characterized by site-specificity and method-specificity),the appropriate measurement method for the task needs to be chosen based on theoretical considerations and/or ecological validity.展开更多
Objective:To assess the concordance of tumour grade in specimens obtained from diagnostic cystoscopic biopsy and transurethral resection of bladder tumour(TURBT)and explore the risk factors of upgrading.Methods:The me...Objective:To assess the concordance of tumour grade in specimens obtained from diagnostic cystoscopic biopsy and transurethral resection of bladder tumour(TURBT)and explore the risk factors of upgrading.Methods:The medical records of 205 outpatients who underwent diagnostic cystoscopic biopsy before initial TURBT were retrospectively reviewed.Comparative analysis of the tumour grade of biopsy and operation specimens was performed.Tumour grade changing from low-grade to high-grade with or without variant histology was defined as upgrading.Logistic regression an-alyses were performed to identify the risk factors of upgrading.Results:For the 205 patients,the concordance of tumour grade between specimens obtained from biopsy and operation was 0.639.The concordance for patients who were preoperatively diagnosed with low-grade and high-grade was 0.504 and 0.912,respectively.Univariate and multivariate logistic regression analyses showed that older age,tumour multifocality,high neutrophil-to-lymphocyte ratio(NLR),platelet-to-lymphocyte ratio(PLR),and low lymphocyte-to-monocyte ratio(LMR)were significantly associated with upgrading(odds ratio ranging from 0.412 to 4.364).The area under the curve of the different multivariate models was improved from 0.752 to 0.821,and decision curve analysis demonstrated a high net benefit when NLR,LMR,and PLR were added.Conclusion:Diagnostic cystoscopic biopsy may not accurately represent the true grade of primary bladder cancer,especially for outpatients with low-grade bladder cancer.Moreover,older age,tumour multifocality,high NLR,PLR,and low LMR are risk factors of upgrading,and systemic inflammatory markers improve the predictive ability.展开更多
In this work the performance of a screening analytical method for Energy Dispersive X-Ray Fluorescence (EDXRF) analysis in terms of accuracy and precision was evaluated through analysis of rock standard reference mate...In this work the performance of a screening analytical method for Energy Dispersive X-Ray Fluorescence (EDXRF) analysis in terms of accuracy and precision was evaluated through analysis of rock standard reference materials. The method allowed the division of elements into four groups taking into account the excitation energies and measurement conditions of the sample. Two standard reference materials were used and 15 sample replicates were prepared and analyzed, then statistics were applied to assess the precision and accuracy of analytical results. The obtained results show that major compounds or elements (SiO<sub>2</sub>, P<sub>2</sub>O<sub>5</sub>, K<sub>2</sub>O, CaO, Fe<sub>2</sub>O<sub>3</sub>, Ti) can be determined in fine powder sample with a deviation lower than 15%, and a relative standard deviation in the range (1 - 10)%. The deviation was found to be lower than 5% for major compounds such as K<sub>2</sub>O, and CaO, which suggest that the EDXRF is accurate in evaluating major elemental concentrations in rock samples. It was also found that the method seems to be more accurate and precise for major elements than for trace element investigation. This screening analytical method can be used for routine analysis with acceptable results, even though the method should be optimized to increase its precision and accuracy.展开更多
Albacore tuna(Thunnus alalunga)is one of the target species of tuna longline fishing,and waters near the Cook Islands are a vital albacore tuna fishing ground.Marine environmental data are usually presented with diffe...Albacore tuna(Thunnus alalunga)is one of the target species of tuna longline fishing,and waters near the Cook Islands are a vital albacore tuna fishing ground.Marine environmental data are usually presented with different spatial resolutions,which leads to different results in tuna fishery prediction.Study on the impact of different spatial resolutions on the prediction accuracy of albacore tuna fishery to select the best spatial resolution can contribute to better management of albacore tuna resources.The nominal catch per unit effort(CPUE)of albacore tuna is calculated according to vessel monitor system(VMS)data collected from Chinese distantwater fishery enterprises from January 1,2017 to May 31,2021.A total of 26 spatiotemporal and environmental factors,including temperature,salinity,dissolved oxygen of 0–300 m water layer,chlorophyll-a concentration in the sea surface,sea surface height,month,longitude,and latitude,were selected as variables.The temporal resolution of the variables was daily and the spatial resolutions were set to be 0.5°×0.5°,1°×1°,2°×2°,and 5°×5°.The relationship between the nominal CPUE and each individual factor was analyzed to remove the factors irrelavant to the nominal CPUE,together with a multicollinearity diagnosis on the factors to remove factors highly related to the other factors within the four spatial resolutions.The relationship models between CPUE and spatiotemporal and environmental factors by four spatial resolutions were established based on the long short-term memory(LSTM)neural network model.The mean absolute error(MAE)and root mean square error(RMSE)were used to analyze the fitness and accuracy of the models,and to determine the effects of different spatial resolutions on the prediction accuracy of the albacore tuna fishing ground.The results show the resolution of 1°×1°can lead to the best prediction accuracy,with the MAE and RMSE being 0.0268 and 0.0452 respectively,followed by 0.5°×0.5°,2°×2°and 5°×5°with declining prediction accuracy.The results suggested that 1)albacore tuna fishing ground can be predicted by LSTM;2)the VMS records the data in detail and can be used scientifically to calculate the CPUE;3)correlation analysis,and multicollinearity diagnosis are necessary to improve the prediction accuracy of the model;4)the spatial resolution should be 1°×1°in the forecast of albacore tuna fishing ground in waters near the Cook Islands.展开更多
The alpha–beta filter algorithm has been widely researched for various applications,for example,navigation and target tracking systems.To improve the dynamic performance of the alpha–beta filter algorithm,a new pred...The alpha–beta filter algorithm has been widely researched for various applications,for example,navigation and target tracking systems.To improve the dynamic performance of the alpha–beta filter algorithm,a new prediction learning model is proposed in this study.The proposed model has two main components:(1)the alpha–beta filter algorithm is the main prediction module,and(2)the learning module is a feedforward artificial neural network(FF‐ANN).Furthermore,the model uses two inputs,temperature sensor and humidity sensor data,and a prediction algorithm is used to predict actual sensor readings from noisy sensor readings.Using the novel proposed technique,prediction accuracy is significantly improved while adding the feed‐forward backpropagation neural network,and also reduces the root mean square error(RMSE)and mean absolute error(MAE).We carried out different experiments with different experimental setups.The proposed model performance was evaluated with the traditional alpha–beta filter algorithm and other algorithms such as the Kalman filter.A higher prediction accuracy was achieved,and the MAE and RMSE were 35.1%–38.2%respectively.The final proposed model results show increased performance when compared to traditional methods.展开更多
The application of continuous natural fibers as reinforcement in composite thin-walled structures offers a feasible approach to achieve light weight and high strength while remaining environmentally friendly.In additi...The application of continuous natural fibers as reinforcement in composite thin-walled structures offers a feasible approach to achieve light weight and high strength while remaining environmentally friendly.In addition,additive manufacturing technology provides a favorable process foundation for its realization.In this study,the printability and energy absorption properties of 3D printed continuous fiber reinforced thin-walled structures with different configurations were investigated.The results suggested that a low printing speed and a proper layer thickness would mitigate the printing defects within the structures.The printing geometry accuracy of the structures could be further improved by rounding the sharp corners with appropriate radii.This study successfully fabricated structures with vari-ous configurations characterized by high geometric accuracy through printing parameters optimization and path smoothing.Moreover,the compressive property and energy absorption characteristics of the structures under quasi-static axial compression were evaluated and compared.It was found that all studied thin-walled structures exhibited progressive folding deformation patterns during compression.In particular,energy absorption process was achieved through the combined damage modes of plastic deformation,fiber pullout and delamination.Furthermore,the com-parison results showed that the hexagonal structure exhibited the best energy absorption performance.The study revealed the structure-mechanical property relationship of 3D printed continuous fiber reinforced composite thin-walled structures through the analysis of multiscale failure characteristics and load response,which is valuable for broadening their applications.展开更多
Background: Accurate determination of gestational age has become important for deciding the appropriate time for termination of the pregnancy as well as to monitor the fetal growth during the entire period of pregnanc...Background: Accurate determination of gestational age has become important for deciding the appropriate time for termination of the pregnancy as well as to monitor the fetal growth during the entire period of pregnancy. Objective: The aim of the study was to assess whether the trans-cerebellar diameter, placental thickness or combining both of them is more accurate for assessment of gestational age in the 3<sup>rd</sup> trimester of pregnancy. Patients and Methods: This is a cross sectional study conducted at outpatient Clinic and Obstetric ward, Ain Shams University Maternity Hospital, over a period of six months from March 2019 to September 2019. One hundred pregnant women were recruited according to inclusion criteria either from outpatient clinic or were admitted in obstetric ward Ain Shams Maternity Hospital to find out the most accurate fetal biometric measurement in the third trimester either trans-cerebellar diameter placental thickness or both compared to reliable LMP (last menstrual period) dates confirmed by crown rump length (CRL) in the first trimester. Results: Trans-cerebellar diameter mean ± SD was 46.0 ± 3.5 with range 38.2 - 51.7. The mean of placental thickness was 39.6 ± 7.1 with range 22.8 - 54.3. Placental thickness had highest determination (0.813) for last menstrual period followed by trans-cerebellar diameter (0.802). Combining trans-cerebellar diameter and placental thickness increased determination (0.902) for last menstrual period. Conclusion: Combined use of trans-cerebellar diameter and placental thickness in the third trimester of pregnancy is a reliable indicator for gestational age in women whose last menstrual period is unreliable or unknown, but placental thickness had higher accuracy than trans-cerebellar diameter.展开更多
The Global Positioning System(GPS)is a GNSS constellation,but GNSS is not always GPS.GPS is one of the GNSS constellations used around the world.The GNSS constellations include GPS(US),QZSS(Japan),Beidou/BDS(China),Ga...The Global Positioning System(GPS)is a GNSS constellation,but GNSS is not always GPS.GPS is one of the GNSS constellations used around the world.The GNSS constellations include GPS(US),QZSS(Japan),Beidou/BDS(China),Galileo(EU),and GLONASS(Russia).In 1999,the European Commission(EC)proposed the European Galileo satellite navigation system for the first time.A four-phase development was proposed,including public and private sector finance.Galileo was intended for both civilian and government use,and is managed and controlled by civil authorities.Galileo is made up of 30 satellites,a number of globally distributed ground stations,and a ground control and monitoring system,all of which are extremely similar to the structure,format,and layout of GPS.In this study,we investigate GPS/GLONASS/Galileo/Beidou/IRNSS/QZSS Navigation Satellite System integration algorithm for long baselines ranging from 1500 km to 3000 km in China,Japan and Mongolia.The positioning performance with GPS/GLONASS/Galileo/BDS/IRNSS/QZSS,GPS-only,Galileo-only,GLONASS-only and BDS-only,etc.is compared in terms of the positioning accuracy.An improvement of positioning accuracy over long baselines can be found with GPS/GLONASS/Galileo/BDS/QZSS/IRNSS compared with that of GPS-only and that of BDS-only.The obtained differences of the two baselines(Topcon Magnet Tools Software(Multi-GNSS)-(CSRS-PPP(GPS/GLONASS),(Trimble-RTX(GPS/GLONASS),(AUSPOS(GPS/GLONASS))Online Processing Software)by using GPS/GLONASS/Galileo/BDS/QZSS/IRNSS signals is between 40 cm and 111.5 cm on three days.展开更多
The Riemann wave system has a fundamental role in describing waves in various nonlinear natural phenomena,for instance,tsunamis in the oceans.This paper focuses on executing the generalized exponential rational functi...The Riemann wave system has a fundamental role in describing waves in various nonlinear natural phenomena,for instance,tsunamis in the oceans.This paper focuses on executing the generalized exponential rational function approach and some numerical methods to obtain a distinct range of traveling wave structures and numerical results of the two-dimensional Riemann problems.The stability of obtained traveling wave solutions is analyzed by satisfying the constraint conditions of the Hamiltonian system.Numerical simulations are investigated via the finite difference method to verify the accuracy of the obtained results.To extract the approximation solutions to the underlying problem,some ODE solvers in FORTRAN software are applied,and outcomes are shown graphically.The stability and accuracy of the numerical schemes using Fourier’s stabilitymethod and error analysis,respectively,to increase the reassurance are investigated.A comparison between the analytical and numerical results is obtained and graphically provided.The proposed methods are effective and practical to be applied for solving more partial differential equations(PDEs).展开更多
基金supported by the National Key Research and Development Program of China(2022YFB3903503)the National Natural Science Foundation of China(U1901601)the Science and Technology Project of the Department of Education of Jiangxi Province,China(GJJ210541)。
文摘Various land use and land cover(LULC)products have been produced over the past decade with the development of remote sensing technology.Despite the differences in LULC classification schemes,there is a lack of research on assessing the accuracy of their application to croplands in a unified framework.Thus,this study evaluated the spatial and area accuracies of cropland classification for four commonly used global LULC products(i.e.,MCD12Q1V6,GlobCover2009,FROM-GLC and GlobeLand30)based on the harmonised FAO criterion,and quantified the relationships between four factors(i.e.,slope,elevation,field size and crop system)and cropland classification agreement.The validation results indicated that MCD12Q1 and GlobeLand30 performed well in cropland classification regarding spatial consistency,with overall accuracies of 94.90 and 93.52%,respectively.The FROMGLC showed the worst performance,with an overall accuracy of 83.17%.Overlaying the cropland generated by the four global LULC products,we found the proportions of complete agreement and disagreement were 15.51 and 44.72% for the cropland classification,respectively.High consistency was mainly observed in the Northeast China Plain,the Huang-Huai-Hai Plain and the northern part of the Middle-lower Yangtze Plain,China.In contrast,low consistency was detected primarily on the eastern edge of the northern and semiarid region,the Yunnan-Guizhou Plateau and southern China.Field size was the most important factor for mapping cropland.For area accuracy,compared with China Statistical Yearbook data at the provincial scale,the accuracies of different products in descending order were:GlobeLand30,FROM-GLC,MCD12Q1,and GlobCover2009.The cropland classification schemes mainly caused large area deviations among the four products,and they also resulted in the different ranks of spatial accuracy and area accuracy among the four products.Our results can provide valuable suggestions for selecting cropland products at the national or provincial scale and help cropland mapping and reconstruction,which is essential for food security and crop management,so they can also contribute to achieving the Sustainable Development Goals issued by the United Nations.
文摘BACKGROUND As one of the fatal diseases with high incidence,lung cancer has seriously endangered public health and safety.Elderly patients usually have poor self-care and are more likely to show a series of psychological problems.AIM To investigate the effectiveness of the initial check,information exchange,final accuracy check,reaction(IIFAR)information care model on the mental health status of elderly patients with lung cancer.METHODS This study is a single-centre study.We randomly recruited 60 elderly patients with lung cancer who attended our hospital from January 2021 to January 2022.These elderly patients with lung cancer were randomly divided into two groups,with the control group taking the conventional propaganda and education and the observation group taking the IIFAR information care model based on the conventional care protocol.The differences in psychological distress,anxiety and depression,life quality,fatigue,and the locus of control in psychology were compared between these two groups,and the causes of psychological distress were analyzed.RESULTS After the intervention,Distress Thermometer,Hospital Anxiety and Depression Scale(HADS)for anxiety and the HADS for depression,Revised Piper’s Fatigue Scale,and Chance Health Locus of Control scores were lower in the observation group compared to the pre-intervention period in the same group and were significantly lower in the observation group compared to those of the control group(P<0.05).After the intervention,Quality of Life Questionnaire Core 30(QLQ-C30),Internal Health Locus of Control,and Powerful Others Health Locus of Control scores were significantly higher in the observation and the control groups compared to the pre-intervention period in their same group,and QLQ-C30 scores were significantly higher in the observation group compared to those of the control group(P<0.05).CONCLUSION The IIFAR information care model can help elderly patients with lung cancer by reducing their anxiety and depression,psychological distress,and fatigue,improving their tendencies on the locus of control in psychology,and enhancing their life qualities.
基金Supported by Scientific Initiation Scholarship Programme(PIBIC)of the Bahia State Research Support Foundationthe Doctorate Scholarship Program of the Coordination of Improvement of Higher Education Personnel+1 种基金the Scientific Initiation Scholarship Programme(PIBIC)of the National Council for Scientific and Technological Developmentand the CNPq Research Productivity Fellowship.
文摘BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice.
基金funded by the National Natural Science Foundation of China(No.32170788)National High Level Hospital Clinical Research Funding(No.2022-PUMCH-B-023)Beijing Natural Science Foundation(No.7232123).
文摘Objective To assess the diagnostic accuracy of bowel sound analysis for irritable bowel syndrome(IBS)with a systematic review and meta-analysis.Methods We searched MEDLINE,Embase,the Cochrane Library,Web of Science,and IEEE Xplore databases until September 2023.Cross-sectional and case-control studies on diagnostic accuracy of bowel sound analysis for IBS were identified.We estimated the pooled sensitivity,specificity,positive likelihood ratio,negative likeli-hood ratio,and diagnostic odds ratio with a 95% confidence interval(CI),and plotted a summary receiver operat-ing characteristic curve and evaluated the area under the curve.Results Four studies were included.The pooled diagnostic sensitivity,specificity,positive likelihood ratio,nega-tive likelihood ratio,and diagnostic odds ratio were 0.94(95%CI,0.87‒0.97),0.89(95%CI,0.81‒0.94),8.43(95%CI,4.81‒14.78),0.07(95%CI,0.03‒0.15),and 118.86(95%CI,44.18‒319.75),respectively,with an area under the curve of 0.97(95%CI,0.95‒0.98).Conclusions Computerized bowel sound analysis is a promising tool for IBS.However,limited high-quality data make the results'validity and applicability questionable.There is a need for more diagnostic test accuracy studies and better wearable devices for monitoring and analysis of IBS.
基金Supported by Health and Family Planning Project of Sichuan Province,No.17PJ069Tibet Autonomous Region Science and Technology Program,No.XZ202303ZY0011G.
文摘BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies investigating its accuracy has increased.However,its accuracy has not been investigated in highland populations in China.AIM To evaluate measurements recorded using the FreeStyle Libre FGM system compared with capillary blood glucose measured using the enzyme electrode method in patients with type 2 diabetes(T2D)who had migrated within 3 mo from highlands to plains.METHODS Overall,68 patients with T2D,selected from those who had recently migrated from highlands to plains(within 3 mo),were hospitalized at the Department of Endocrinology from August to October 2017 and underwent continuous glucose monitoring(CGM)with the FreeStyle Libre FGM system for 14 d.Throughout the study period,fingertip capillary blood glucose was measured daily using the enzyme electrode method(Super GL,China),and blood glucose levels were read from the scanning probe during fasting and 2 h after all three meals.Moreover,the time interval between reading the data from the scanning probe and collecting fingertip capillary blood was controlled to<5 min.The accuracy of the FGM system was evaluated according to the CGM guidelines.Subsequently,the factors influencing the mean absolute relative difference(MARD)of this system were analyzed by a multiple linear regression method.RESULTS Pearson’s correlation analysis showed that the fingertip and scanned glucose levels were positively correlated(R=0.86,P=0.00).The aggregated MARD of scanned glucose was 14.28±13.40%.Parker's error analysis showed that 99.30%of the data pairs were located in areas A and B.According to the probe wear time of the FreeStyle Libre FGM system,MARD_(1 d) and MARD_(2-14 d) were 16.55%and 14.35%,respectively(t=1.23,P=0.22).Multiple stepwise regression analysis showed that MARD did not correlate with blood glucose when the largest amplitude of glycemic excursion(LAGE)was<5.80 mmol/L but negatively correlated with blood glucose when the LAGE was≥5.80 mmol/L.CONCLUSION The FreeStyle Libre FGM system has good accuracy in patients with T2D who had recently migrated from highlands to plains.This system might be ideal for avoiding the effects of high hematocrit on blood glucose monitoring in populations that recently migrated to plains.MARD is mainly influenced by glucose levels and fluctuations,and the accuracy of the system is higher when the blood glucose fluctuation is small.In case of higher blood glucose level fluctuations,deviation in the scanned glucose levels is the highest at extremely low blood glucose levels.
文摘BACKGROUND Due to frequent and high-risk sports activities,the elbow joint is susceptible to injury,especially to cartilage tissue,which can cause pain,limited movement and even loss of joint function.AIM To evaluate magnetic resonance imaging(MRI)multisequence imaging for improving the diagnostic accuracy of adult elbow cartilage injury.METHODS A total of 60 patients diagnosed with elbow cartilage injury in our hospital from January 2020 to December 2021 were enrolled in this retrospective study.We analyzed the accuracy of conventional MRI sequences(T1-weighted imaging,T2-weighted imaging,proton density weighted imaging,and T2 star weighted image)and Three-Dimensional Coronary Imaging by Spiral Scanning(3D-CISS)in the diagnosis of elbow cartilage injury.Arthroscopy was used as the gold standard to evaluate the diagnostic effect of single and combination sequences in different injury degrees and the consistency with arthroscopy.RESULTS The diagnostic accuracy of 3D-CISS sequence was 89.34%±4.98%,the sensitivity was 90%,and the specificity was 88.33%,which showed the best performance among all sequences(P<0.05).The combined application of the whole sequence had the highest accuracy in all sequence combinations,the accuracy of mild injury was 91.30%,the accuracy of moderate injury was 96.15%,and the accuracy of severe injury was 93.33%(P<0.05).Compared with arthroscopy,the combination of all MRI sequences had the highest consistency of 91.67%,and the kappa value reached 0.890(P<0.001).CONCLUSION Combination of 3D-CISS and each sequence had significant advantages in improving MRI diagnostic accuracy of elbow cartilage injuries in adults.Multisequence MRI is recommended to ensure the best diagnosis and treatment.
文摘The dimensional accuracy of machined parts is strongly influenced by the thermal behavior of machine tools (MT). Minimizing this influence represents a key objective for any modern manufacturing industry. Thermally induced positioning error compensation remains the most effective and practical method in this context. However, the efficiency of the compensation process depends on the quality of the model used to predict the thermal errors. The model should consistently reflect the relationships between temperature distribution in the MT structure and thermally induced positioning errors. A judicious choice of the number and location of temperature sensitive points to represent heat distribution is a key factor for robust thermal error modeling. Therefore, in this paper, the temperature sensitive points are selected following a structured thermomechanical analysis carried out to evaluate the effects of various temperature gradients on MT structure deformation intensity. The MT thermal behavior is first modeled using finite element method and validated by various experimentally measured temperature fields using temperature sensors and thermal imaging. MT Thermal behavior validation shows a maximum error of less than 10% when comparing the numerical estimations with the experimental results even under changing operation conditions. The numerical model is used through several series of simulations carried out using varied working condition to explore possible relationships between temperature distribution and thermal deformation characteristics to select the most appropriate temperature sensitive points that will be considered for building an empirical prediction model for thermal errors as function of MT thermal state. Validation tests achieved using an artificial neural network based simplified model confirmed the efficiency of the proposed temperature sensitive points allowing the prediction of the thermally induced errors with an accuracy greater than 90%.
文摘Machining is as old as humanity, and changes in temperature in both the machine’s internal and external environments can be of great concern as they affect the machine’s thermal stability and, thus, the machine’s dimensional accuracy. This paper is a continuation of our earlier work, which aimed to analyze the effect of the internal temperature of a machine tool as the machine is put into operation and vary the external temperature, the machine floor temperature. Some experiments are carried out under controlled conditions to study how machine tool components get heated up and how this heating up affects the machine’s accuracy due to thermally induced deviations. Additionally, another angle is added by varying the machine floor temperature. The parameters mentioned above are explored in line with the overall thermal stability of the machine tool and its dimensional accuracy. A Robodrill CNC machine tool is used. The CNC was first soaked with thermal energy by gradually raising the machine floor temperature to a certain level before putting the machine in operation. The machine was monitored, and analytical methods were deplored to evaluate thermal stability. Secondly, the machine was run idle for some time under raised floor temperature before it was put into operation. Data was also collected and analyzed. It is observed that machine thermal stability can be achieved in several ways depending on how the above parameters are joggled. This paper, in conclusion, reinforces the idea of machine tool warm-up process in conjunction with a carefully analyzed and established machine floor temperature variation for the approximation of the machine tool’s thermally stability to map the long-time behavior of the machine tool.
文摘Objective: To analyze the accuracy of serum prealbumin levels in predicting the prognosis of patients with critical respiratory illness. Methods: Fifty patients with critical respiratory illness admitted to our hospital from October 2022 to September 2023 were selected and divided into an observation group and a control group after condition assessment, with 25 cases in each group. The results of cholinesterase (ChE), prealbumin (PALB), albumin (ALB), aspartate aminotransferase (AST), total protein (TP), and forced expiratory volume (FEV1)/Predicted (Pred) of the two groups were measured. Results: The ChE levels of the observation group were lower than those of the control group, while the PALB and ALB levels of the observation group were higher than those of the control group (P < 0.05). The AST, TP, and FEV1 /Pred levels of the observation group were higher than those in the control group (P < 0.05). Conclusion: Serum PALB levels can be used as the main indicator for prognosis in critically ill respiratory patients.
文摘Because the vector of angular momentum of ESG (electrostatically suspended gyroscope) maintains the fixed direction in inertial space, it may be regarded as a fixed star. The astronavigation aigorithm is used to estimate the azimuth angle and the gyro constant drift in the paper. The relative errors which affect the estimation accuracy of the azimuth angle are the analysed.
基金Supported by the Chongqing International Science and Technology Cooperation Base Project(cstc2014gjhz40001)the University Achievement Transformation Project of Chongqing Science and Technology Commission(KJZH17115)+3 种基金the Basic Research Project of Chongqing Science and Technology Commission(cstc2015jcyjBX0068,cstc2014jcyjA1350,cstc2015jcyjB0360)the Dr.Start-up Fund of Chongqing University of Posts and Telecommunications(A2015-40,A2016-76)the National Natural Science Foundation of Chongqing University of Posts and Telecommunications(A2015-49)the Scientific and Technological Research Program of Chongqing Municipal Education Commission(KJ1704104,KJ1704091)
文摘A novel on-line north-seeking method based on a three-axis micro-electro-mechanical system(MEMS)gyroscope is designed.This system processes data by using a Kalman filter to calibrate the installation error of the three-axis MEMS gyroscope in complex environment.The attitude angle updating for quaternion,based on which the attitude instrument will be rotated in real-time and the true north will be found.Our experimental platform constitutes the dual-axis electric rotary table and the attitude instrument,which is developed independently by our scientific research team.The experimental results show that the accuracy of north-seeking is higher than 1°,while the maximum root mean square error and the maximum mean absolute error are 0.906 7 and 0.910 0,respectively.The accuracy of north-seeking is much higher than the traditional method.
基金supported by the UNKP-20-3 New National Excellence Program of the Ministry for Innovation and Technology from the source of the National Research,Development and Innovation Fund(úNKP-20-3-Ⅱ-ELTE-163)supported by the Fonds voor Wetenschappelijk Onderzoek—Vlaanderen(FWO)Research Foundation Flanders(11M2622N)the Special Research Fund(Het Bijzonder Onderzoeksfonds,BOF)of Hasselt University(BOF19KP08)。
文摘Background:Proprioceptive accuracy refers to the individual’s ability to perceive proprioceptive information,that is,the information referring to the actual state of the locomotor system,which originates from mechanoreceptors located in various parts of the locomotor system and from tactile receptors located in the skin.Proprioceptive accuracy appears to be an important aspect in the evaluation of sensorimotor functioning;however,no widely accepted standard assessment exists.In this systematic review,our goal was to identify and categorize different methods that are used to assess different aspects of proprioceptive accuracy.Methods:A literature search was conducted in 5 different databases(PubMed,SPORTDiscus,PsycINFO,ScienceDirect,and SpringerLink).Results:Overall,1139 scientific papers reporting 1346 methods were included in this review.The methods assess 8 different aspects of proprioception:(a)the perception of joint position,(b)movement and movement extent,(c)trajectory,(d)velocity,and the sense of(e)force,(f)muscle tension,(g)weight,and(h)size.They apply various paradigms of psychophysics(i.e.,the method of adjustment,constant stimuli,and limits).Conclusion:As the outcomes of different tasks with respect to various body parts show no associations(i.e.,proprioceptive accuracy is characterized by site-specificity and method-specificity),the appropriate measurement method for the task needs to be chosen based on theoretical considerations and/or ecological validity.
基金This study was supported by the Clinical Research Award of the First Affiliated Hospital of Xi'an Jiaotong University,China(No.XJTU1AF-CRF-2015-002 to DH).
文摘Objective:To assess the concordance of tumour grade in specimens obtained from diagnostic cystoscopic biopsy and transurethral resection of bladder tumour(TURBT)and explore the risk factors of upgrading.Methods:The medical records of 205 outpatients who underwent diagnostic cystoscopic biopsy before initial TURBT were retrospectively reviewed.Comparative analysis of the tumour grade of biopsy and operation specimens was performed.Tumour grade changing from low-grade to high-grade with or without variant histology was defined as upgrading.Logistic regression an-alyses were performed to identify the risk factors of upgrading.Results:For the 205 patients,the concordance of tumour grade between specimens obtained from biopsy and operation was 0.639.The concordance for patients who were preoperatively diagnosed with low-grade and high-grade was 0.504 and 0.912,respectively.Univariate and multivariate logistic regression analyses showed that older age,tumour multifocality,high neutrophil-to-lymphocyte ratio(NLR),platelet-to-lymphocyte ratio(PLR),and low lymphocyte-to-monocyte ratio(LMR)were significantly associated with upgrading(odds ratio ranging from 0.412 to 4.364).The area under the curve of the different multivariate models was improved from 0.752 to 0.821,and decision curve analysis demonstrated a high net benefit when NLR,LMR,and PLR were added.Conclusion:Diagnostic cystoscopic biopsy may not accurately represent the true grade of primary bladder cancer,especially for outpatients with low-grade bladder cancer.Moreover,older age,tumour multifocality,high NLR,PLR,and low LMR are risk factors of upgrading,and systemic inflammatory markers improve the predictive ability.
文摘In this work the performance of a screening analytical method for Energy Dispersive X-Ray Fluorescence (EDXRF) analysis in terms of accuracy and precision was evaluated through analysis of rock standard reference materials. The method allowed the division of elements into four groups taking into account the excitation energies and measurement conditions of the sample. Two standard reference materials were used and 15 sample replicates were prepared and analyzed, then statistics were applied to assess the precision and accuracy of analytical results. The obtained results show that major compounds or elements (SiO<sub>2</sub>, P<sub>2</sub>O<sub>5</sub>, K<sub>2</sub>O, CaO, Fe<sub>2</sub>O<sub>3</sub>, Ti) can be determined in fine powder sample with a deviation lower than 15%, and a relative standard deviation in the range (1 - 10)%. The deviation was found to be lower than 5% for major compounds such as K<sub>2</sub>O, and CaO, which suggest that the EDXRF is accurate in evaluating major elemental concentrations in rock samples. It was also found that the method seems to be more accurate and precise for major elements than for trace element investigation. This screening analytical method can be used for routine analysis with acceptable results, even though the method should be optimized to increase its precision and accuracy.
基金the National Natural Science Foundation of China(No.32273185)the National Key R&D Program of China(No.2020YFD0901205)the Marine Fishery Resources Investigation and Exploration Program of the Ministry of Agriculture and Rural Affairs of China in 2021(No.D-8006-21-0215)。
文摘Albacore tuna(Thunnus alalunga)is one of the target species of tuna longline fishing,and waters near the Cook Islands are a vital albacore tuna fishing ground.Marine environmental data are usually presented with different spatial resolutions,which leads to different results in tuna fishery prediction.Study on the impact of different spatial resolutions on the prediction accuracy of albacore tuna fishery to select the best spatial resolution can contribute to better management of albacore tuna resources.The nominal catch per unit effort(CPUE)of albacore tuna is calculated according to vessel monitor system(VMS)data collected from Chinese distantwater fishery enterprises from January 1,2017 to May 31,2021.A total of 26 spatiotemporal and environmental factors,including temperature,salinity,dissolved oxygen of 0–300 m water layer,chlorophyll-a concentration in the sea surface,sea surface height,month,longitude,and latitude,were selected as variables.The temporal resolution of the variables was daily and the spatial resolutions were set to be 0.5°×0.5°,1°×1°,2°×2°,and 5°×5°.The relationship between the nominal CPUE and each individual factor was analyzed to remove the factors irrelavant to the nominal CPUE,together with a multicollinearity diagnosis on the factors to remove factors highly related to the other factors within the four spatial resolutions.The relationship models between CPUE and spatiotemporal and environmental factors by four spatial resolutions were established based on the long short-term memory(LSTM)neural network model.The mean absolute error(MAE)and root mean square error(RMSE)were used to analyze the fitness and accuracy of the models,and to determine the effects of different spatial resolutions on the prediction accuracy of the albacore tuna fishing ground.The results show the resolution of 1°×1°can lead to the best prediction accuracy,with the MAE and RMSE being 0.0268 and 0.0452 respectively,followed by 0.5°×0.5°,2°×2°and 5°×5°with declining prediction accuracy.The results suggested that 1)albacore tuna fishing ground can be predicted by LSTM;2)the VMS records the data in detail and can be used scientifically to calculate the CPUE;3)correlation analysis,and multicollinearity diagnosis are necessary to improve the prediction accuracy of the model;4)the spatial resolution should be 1°×1°in the forecast of albacore tuna fishing ground in waters near the Cook Islands.
基金supported by the Institute of Information&communications Technology Planning&Evaluation(IITP)grant funded by the Korea government(MSIT)(No.2020‐0‐01441,Artificial Intelligence Convergence Research Center(Chungnam National University))“Regional Innovation Strategy(RIS)”through the National Research Foundation of Korea(NRF)funded by the Ministry of Education(MOE)(2021RIS‐004).
文摘The alpha–beta filter algorithm has been widely researched for various applications,for example,navigation and target tracking systems.To improve the dynamic performance of the alpha–beta filter algorithm,a new prediction learning model is proposed in this study.The proposed model has two main components:(1)the alpha–beta filter algorithm is the main prediction module,and(2)the learning module is a feedforward artificial neural network(FF‐ANN).Furthermore,the model uses two inputs,temperature sensor and humidity sensor data,and a prediction algorithm is used to predict actual sensor readings from noisy sensor readings.Using the novel proposed technique,prediction accuracy is significantly improved while adding the feed‐forward backpropagation neural network,and also reduces the root mean square error(RMSE)and mean absolute error(MAE).We carried out different experiments with different experimental setups.The proposed model performance was evaluated with the traditional alpha–beta filter algorithm and other algorithms such as the Kalman filter.A higher prediction accuracy was achieved,and the MAE and RMSE were 35.1%–38.2%respectively.The final proposed model results show increased performance when compared to traditional methods.
基金Supported by National Natural Science Foundation of China(Grant Nos.51905555,52105523)Hu-Xiang Youth Talent Program of China(Grant No.2020RC3009)Innovation-Driven Project of Central South University of China(Grant No.2019CX017).
文摘The application of continuous natural fibers as reinforcement in composite thin-walled structures offers a feasible approach to achieve light weight and high strength while remaining environmentally friendly.In addition,additive manufacturing technology provides a favorable process foundation for its realization.In this study,the printability and energy absorption properties of 3D printed continuous fiber reinforced thin-walled structures with different configurations were investigated.The results suggested that a low printing speed and a proper layer thickness would mitigate the printing defects within the structures.The printing geometry accuracy of the structures could be further improved by rounding the sharp corners with appropriate radii.This study successfully fabricated structures with vari-ous configurations characterized by high geometric accuracy through printing parameters optimization and path smoothing.Moreover,the compressive property and energy absorption characteristics of the structures under quasi-static axial compression were evaluated and compared.It was found that all studied thin-walled structures exhibited progressive folding deformation patterns during compression.In particular,energy absorption process was achieved through the combined damage modes of plastic deformation,fiber pullout and delamination.Furthermore,the com-parison results showed that the hexagonal structure exhibited the best energy absorption performance.The study revealed the structure-mechanical property relationship of 3D printed continuous fiber reinforced composite thin-walled structures through the analysis of multiscale failure characteristics and load response,which is valuable for broadening their applications.
文摘Background: Accurate determination of gestational age has become important for deciding the appropriate time for termination of the pregnancy as well as to monitor the fetal growth during the entire period of pregnancy. Objective: The aim of the study was to assess whether the trans-cerebellar diameter, placental thickness or combining both of them is more accurate for assessment of gestational age in the 3<sup>rd</sup> trimester of pregnancy. Patients and Methods: This is a cross sectional study conducted at outpatient Clinic and Obstetric ward, Ain Shams University Maternity Hospital, over a period of six months from March 2019 to September 2019. One hundred pregnant women were recruited according to inclusion criteria either from outpatient clinic or were admitted in obstetric ward Ain Shams Maternity Hospital to find out the most accurate fetal biometric measurement in the third trimester either trans-cerebellar diameter placental thickness or both compared to reliable LMP (last menstrual period) dates confirmed by crown rump length (CRL) in the first trimester. Results: Trans-cerebellar diameter mean ± SD was 46.0 ± 3.5 with range 38.2 - 51.7. The mean of placental thickness was 39.6 ± 7.1 with range 22.8 - 54.3. Placental thickness had highest determination (0.813) for last menstrual period followed by trans-cerebellar diameter (0.802). Combining trans-cerebellar diameter and placental thickness increased determination (0.902) for last menstrual period. Conclusion: Combined use of trans-cerebellar diameter and placental thickness in the third trimester of pregnancy is a reliable indicator for gestational age in women whose last menstrual period is unreliable or unknown, but placental thickness had higher accuracy than trans-cerebellar diameter.
文摘The Global Positioning System(GPS)is a GNSS constellation,but GNSS is not always GPS.GPS is one of the GNSS constellations used around the world.The GNSS constellations include GPS(US),QZSS(Japan),Beidou/BDS(China),Galileo(EU),and GLONASS(Russia).In 1999,the European Commission(EC)proposed the European Galileo satellite navigation system for the first time.A four-phase development was proposed,including public and private sector finance.Galileo was intended for both civilian and government use,and is managed and controlled by civil authorities.Galileo is made up of 30 satellites,a number of globally distributed ground stations,and a ground control and monitoring system,all of which are extremely similar to the structure,format,and layout of GPS.In this study,we investigate GPS/GLONASS/Galileo/Beidou/IRNSS/QZSS Navigation Satellite System integration algorithm for long baselines ranging from 1500 km to 3000 km in China,Japan and Mongolia.The positioning performance with GPS/GLONASS/Galileo/BDS/IRNSS/QZSS,GPS-only,Galileo-only,GLONASS-only and BDS-only,etc.is compared in terms of the positioning accuracy.An improvement of positioning accuracy over long baselines can be found with GPS/GLONASS/Galileo/BDS/QZSS/IRNSS compared with that of GPS-only and that of BDS-only.The obtained differences of the two baselines(Topcon Magnet Tools Software(Multi-GNSS)-(CSRS-PPP(GPS/GLONASS),(Trimble-RTX(GPS/GLONASS),(AUSPOS(GPS/GLONASS))Online Processing Software)by using GPS/GLONASS/Galileo/BDS/QZSS/IRNSS signals is between 40 cm and 111.5 cm on three days.
文摘The Riemann wave system has a fundamental role in describing waves in various nonlinear natural phenomena,for instance,tsunamis in the oceans.This paper focuses on executing the generalized exponential rational function approach and some numerical methods to obtain a distinct range of traveling wave structures and numerical results of the two-dimensional Riemann problems.The stability of obtained traveling wave solutions is analyzed by satisfying the constraint conditions of the Hamiltonian system.Numerical simulations are investigated via the finite difference method to verify the accuracy of the obtained results.To extract the approximation solutions to the underlying problem,some ODE solvers in FORTRAN software are applied,and outcomes are shown graphically.The stability and accuracy of the numerical schemes using Fourier’s stabilitymethod and error analysis,respectively,to increase the reassurance are investigated.A comparison between the analytical and numerical results is obtained and graphically provided.The proposed methods are effective and practical to be applied for solving more partial differential equations(PDEs).