The contents of waste glass powder(WGP)(0%,10%,15%,20%,25%)and water-binder ratio(W/C)(0.24,0.26,0.28)were used as influencing factors,and the quality loss rate(Δm)and compressive strength loss rate(Δfc)were used as...The contents of waste glass powder(WGP)(0%,10%,15%,20%,25%)and water-binder ratio(W/C)(0.24,0.26,0.28)were used as influencing factors,and the quality loss rate(Δm)and compressive strength loss rate(Δfc)were used as characterization parameters.The Ca/Si ratio and main element contents of C-S-H gels with different WGP content were investigated by energy dispersive spectrometry(EDS).The pore structure evolution characteristics of WGP composite cementing materials were investigated by low field nuclear magnetic resonance(NMR).UsingΔfc as the index of frost resistance degradation and Weibull function,the frost resistance degradation of glass doped pervious concrete(WGP-PC)was modeled.The results show that,with WGP,for the same number of cycles,Δm andΔfc decrease and increase with the increase of WGP.Under the same WGP content,Δm andΔfc decrease first and then increase with the increase of W/C.After 100 freeze-thaw cycles,the samples with WGP content of 20%and W/C of 0.26 have the best freeze-resistance.Microscopic tests show that with the increase of WGP content,the Ca/Si ratio of C-S-H gel decreases at first and then increases with the increase of WGP content.The extreme value of Ca/Si is 2.36 when WGP is added by 20%.The pore volume of hardened paste with 20%WGP content decreased by 18.6%compared with that of cement system without WGP.The overall compactness of the specimen was improved.On the basis of the test data,a life prediction model was established according to Weibull function.The experiment showed thatΔfc could be used as a durability degradation index,and the slope of the reliability curve became gentle after WGP was added,which reduced the damage degradation rate of PC.W/C was 0.26.It's about 5000 hours.展开更多
A new method of data access which can effectively resolve the problem of high speed and real time reading data of nuclear instrument in small storage space is introduced. This method applies the data storage mode of ...A new method of data access which can effectively resolve the problem of high speed and real time reading data of nuclear instrument in small storage space is introduced. This method applies the data storage mode of “linked list” to the system of Micro Control Unit (MCU), and realizes the pointer access of nuclear data on the small storage space of MCU. Experimental results show that this method can solve some problems of traditional data storage method, which has the advantages of simple program design, stable performance, accurate data, strong repeatability, saving storage space and so on.展开更多
A millimeter wave solid state source—far infrared laser combined interferometer system(MFCI)consisting of a three-channel 890 GHz hydrogen cyanide(HCN)laser interferometer and a threechannel 340 GHz solid state sourc...A millimeter wave solid state source—far infrared laser combined interferometer system(MFCI)consisting of a three-channel 890 GHz hydrogen cyanide(HCN)laser interferometer and a threechannel 340 GHz solid state source interferometer(SSI)is developed for real-time line-integrated electron density feedback and electron density profile of the EXL-50 spherical tokamak device.The interferometer system is a Mach–Zehnder type,with all probe-channels measured vertically,covering the plasma magnetic axis to the outermost closed magnetic plane.The HCN laser interferometer uses an HCN laser with a frequency of 890 GHz as a light source and modulates a100 k Hz beat signal by a rotating grating,giving a temporal resolution of 10μs.The SSI uses two independent 340 GHz solid-state diode sources as the light source,the frequency of the two sources is adjustable,and the temporal resolution of SSI can reach 1μs by setting the frequency difference of the two lasers at 1 MHz.The main optical path of the two interferometers is compactly installed on a set of double-layer optical platform directly below EXL-50.Dual optical path design using corner cube reflectors avoids the large support structures.Collinear the probebeams of two wavelengths,then the phase error caused by vibration can be compensated.At present,the phase noise of the HCN Interferometer is 0.08 rad,corresponding to a line-integrated electron density of 0.88×10^(17)m^(-2),one channel of measuring result was obtained by the MFCI system,and the highest density measured is about 0.7×10^(19)m^(-2).展开更多
Based on analyzing the induced signals from the double-grids of an ionization chamber, the electron-drift time between the two grids is determined and the electron-drift velocity is derived. A waveform digitizer is em...Based on analyzing the induced signals from the double-grids of an ionization chamber, the electron-drift time between the two grids is determined and the electron-drift velocity is derived. A waveform digitizer is employed to record pulses from the two grids of the ionization chamber. The electron-drift velocity is measured as a function of the reduced electric field E/p for eight different ratios of Ar+CH4 mixtures. By analyzing the experimental data of this study, self-consistency of experimental data is achieved, and formulae for calculating electron-drift velocity in any ratio of Ar+CH4 mixtures are obtained.展开更多
The generation and observation of coherent THz synchrotron radiation from femtosecond electron bunches in the Shanghai Institute of Applied Physics femtosecond accelerator device is reported. We describe the experimen...The generation and observation of coherent THz synchrotron radiation from femtosecond electron bunches in the Shanghai Institute of Applied Physics femtosecond accelerator device is reported. We describe the experiment setup and present the first result of THz radiation properties such as power and spectrum.展开更多
Two dimensional particle-in-cell simulations are taken to study the interaction of a circularly polarized laser pulse with a nano-scale micro-structured target. The protons which are doped in the rear side of the targ...Two dimensional particle-in-cell simulations are taken to study the interaction of a circularly polarized laser pulse with a nano-scale micro-structured target. The protons which are doped in the rear side of the target experience the electrostatic fields caused by both the radiation pressure driven shock and the target normal sheath at the rear side of the target. A quasimonoenergetic proton bunch with central energy of about 11MeV and energy spread of ∆ ε/ε about 0.18 is achieved by using a 3.45×1019 W/cm2, 66fs laser pulse. A comparison with the case of linearly polarized laser pulse and the same target condition is considered.展开更多
A 30-MeV femto-second electron linac is built at the Shanghai Institute of Applied Physics, which can produce high power, coherent THz undulator radiation. We report the experimental facility and measurement of the po...A 30-MeV femto-second electron linac is built at the Shanghai Institute of Applied Physics, which can produce high power, coherent THz undulator radiation. We report the experimental facility and measurement of the power, frequency spectrum. First experiments show the averaged power at THz to be about 20mW.展开更多
Beam dynamics and rf designs of a 104 MHz ladder type IH-RFQ (L-IH-RFQ) accelerator are finished at Peking University for the acceleration of 14C+ from 40 keV to 500 keV. As a specific feature, the output beam ener...Beam dynamics and rf designs of a 104 MHz ladder type IH-RFQ (L-IH-RFQ) accelerator are finished at Peking University for the acceleration of 14C+ from 40 keV to 500 keV. As a specific feature, the output beam energy spread is as low as 0.6% achieved with the internal discrete bunching method, which makes potential applications of RFQ feasible, such as accelerator mass spectrometry and ion implantation. Tolerances of the beam dynamics design are studied by means of changing the input beam parameters, and the results are quite satisfying. On the other hand, the L-IH-RFQ structure is employed, taking advantage of its mechanical stability and the absence of inter-electrode voltage asymmetry. Radio-frequency properties are studied and optimized for reducing power loss with Microwave Studio (MWS). Tuning of the field flatness and frequency is investigated in principle.展开更多
Accelerator mass spectrometry (AMS) is one of the most promising methods to detect minute amounts of 182Hf. However, the sensitivity of 5×10^-11 for ^182Hf/180Hf obtained previously by the AMS method at China I...Accelerator mass spectrometry (AMS) is one of the most promising methods to detect minute amounts of 182Hf. However, the sensitivity of 5×10^-11 for ^182Hf/180Hf obtained previously by the AMS method at China Institute of Atomic Energy (CIAE) cannot meet the requirement of some applications. We present some new improvements of measurement method for AMS measurement of 182Hf at the CIAE HI?13 tandem accelerator system. As a result, a sensitivity of 1.0×10^-11 for 182Hf/180Hf is achieved.展开更多
An experimental measurement of radiatively heated iron plasma transmission spectra was performed on Shenguang II laser facility. In the measurement, the self?emission spectrum, the backlighting spectrum, and the abso...An experimental measurement of radiatively heated iron plasma transmission spectra was performed on Shenguang II laser facility. In the measurement, the self?emission spectrum, the backlighting spectrum, and the absorption spectrum were imaged with a flat filed grating and recorded on a gated micro channel plate detector to obtain the time-resolved transmission spectra in the range 10-20 ? (approximately 0.6-1.3 keV). Experimental results are compared with the calculation results of an unsolved transition array (UTA) code. The time-dependent relative shift in the positions of the 2p-3d transmission array is interpreted in terms of the plasma temperature variations.展开更多
For heating the tokamak plasma effectively, the ion source must be capable of producing ions with high proton ratio. The proton ratio, which is found to be more than 65.6% at the ion current of 19.6A with the extracti...For heating the tokamak plasma effectively, the ion source must be capable of producing ions with high proton ratio. The proton ratio, which is found to be more than 65.6% at the ion current of 19.6A with the extraction voltage of 39.6 k V, is measured with an image spectrograph by Doppler shift effect of Balmer-α-radiation spectrum emitted from fast hydrogen particles. The tendency of proton ratio with the ion density in experiment is almost the same as the mode devised by Zhang et al. Okumura et al. only gave the affection of the plasma volume and ion loss area on the proton ratio, but the relationship between the ion density in chamber and the proton ratio was not presented. We give the relationship.展开更多
Specific activity of primordial radionuclides and associated radiation hazards due to 40K, 226Ra, and 232Th have been measured in backed red brick samples, collected from five highly populated areas of the North West ...Specific activity of primordial radionuclides and associated radiation hazards due to 40K, 226Ra, and 232Th have been measured in backed red brick samples, collected from five highly populated areas of the North West Frontier Province of Pakistan. For the detection, analysis and data acquisition, a high purity germanium detector was used. Associated external doses were calculated using a Monte Carlo neutron photon transport code. A theoretical model to determine the gamma dose rate at 1 m height from the floor, made of bricks, was employed for the calculation of mass attenuation coefficient and self-absorption in the floor for the gamma energies of these radionuclides and their progeny. Monte Carlo simulation shows that in this study the floor, having more than an effective thickness of 15 cm, contributes very little to the external gamma dose rate. The values of the external dose rate and annual effective dose are found to be much lower than the world average as well as from other countries of the world.展开更多
基金Funded by the National Natural Science Foundation of China(No.52468037)the Foster Foundation of ISMI,Gansu Province(No.GII2022-P03)the Gansu Provincial Department of Education(No.2024QB-028)。
文摘The contents of waste glass powder(WGP)(0%,10%,15%,20%,25%)and water-binder ratio(W/C)(0.24,0.26,0.28)were used as influencing factors,and the quality loss rate(Δm)and compressive strength loss rate(Δfc)were used as characterization parameters.The Ca/Si ratio and main element contents of C-S-H gels with different WGP content were investigated by energy dispersive spectrometry(EDS).The pore structure evolution characteristics of WGP composite cementing materials were investigated by low field nuclear magnetic resonance(NMR).UsingΔfc as the index of frost resistance degradation and Weibull function,the frost resistance degradation of glass doped pervious concrete(WGP-PC)was modeled.The results show that,with WGP,for the same number of cycles,Δm andΔfc decrease and increase with the increase of WGP.Under the same WGP content,Δm andΔfc decrease first and then increase with the increase of W/C.After 100 freeze-thaw cycles,the samples with WGP content of 20%and W/C of 0.26 have the best freeze-resistance.Microscopic tests show that with the increase of WGP content,the Ca/Si ratio of C-S-H gel decreases at first and then increases with the increase of WGP content.The extreme value of Ca/Si is 2.36 when WGP is added by 20%.The pore volume of hardened paste with 20%WGP content decreased by 18.6%compared with that of cement system without WGP.The overall compactness of the specimen was improved.On the basis of the test data,a life prediction model was established according to Weibull function.The experiment showed thatΔfc could be used as a durability degradation index,and the slope of the reliability curve became gentle after WGP was added,which reduced the damage degradation rate of PC.W/C was 0.26.It's about 5000 hours.
文摘A new method of data access which can effectively resolve the problem of high speed and real time reading data of nuclear instrument in small storage space is introduced. This method applies the data storage mode of “linked list” to the system of Micro Control Unit (MCU), and realizes the pointer access of nuclear data on the small storage space of MCU. Experimental results show that this method can solve some problems of traditional data storage method, which has the advantages of simple program design, stable performance, accurate data, strong repeatability, saving storage space and so on.
基金supported by the National MCF Energy R&D Program(Nos.2019YFE03040003 and 2017YFE0301205)supported in part by Key Program of Research and Development of Hefei Science Center,CAS(No.2019HSC-KPRD001)partly supported by the Collaborative Research Program of the Research Institute for Applied Mechanics,Kyushu University.
文摘A millimeter wave solid state source—far infrared laser combined interferometer system(MFCI)consisting of a three-channel 890 GHz hydrogen cyanide(HCN)laser interferometer and a threechannel 340 GHz solid state source interferometer(SSI)is developed for real-time line-integrated electron density feedback and electron density profile of the EXL-50 spherical tokamak device.The interferometer system is a Mach–Zehnder type,with all probe-channels measured vertically,covering the plasma magnetic axis to the outermost closed magnetic plane.The HCN laser interferometer uses an HCN laser with a frequency of 890 GHz as a light source and modulates a100 k Hz beat signal by a rotating grating,giving a temporal resolution of 10μs.The SSI uses two independent 340 GHz solid-state diode sources as the light source,the frequency of the two sources is adjustable,and the temporal resolution of SSI can reach 1μs by setting the frequency difference of the two lasers at 1 MHz.The main optical path of the two interferometers is compactly installed on a set of double-layer optical platform directly below EXL-50.Dual optical path design using corner cube reflectors avoids the large support structures.Collinear the probebeams of two wavelengths,then the phase error caused by vibration can be compensated.At present,the phase noise of the HCN Interferometer is 0.08 rad,corresponding to a line-integrated electron density of 0.88×10^(17)m^(-2),one channel of measuring result was obtained by the MFCI system,and the highest density measured is about 0.7×10^(19)m^(-2).
基金Supported by the National Natural Science Foundation of China under Grant Nos 10875006 and 10811120014, and China Nuclear Data Center.
文摘Based on analyzing the induced signals from the double-grids of an ionization chamber, the electron-drift time between the two grids is determined and the electron-drift velocity is derived. A waveform digitizer is employed to record pulses from the two grids of the ionization chamber. The electron-drift velocity is measured as a function of the reduced electric field E/p for eight different ratios of Ar+CH4 mixtures. By analyzing the experimental data of this study, self-consistency of experimental data is achieved, and formulae for calculating electron-drift velocity in any ratio of Ar+CH4 mixtures are obtained.
文摘The generation and observation of coherent THz synchrotron radiation from femtosecond electron bunches in the Shanghai Institute of Applied Physics femtosecond accelerator device is reported. We describe the experiment setup and present the first result of THz radiation properties such as power and spectrum.
基金Supported by the National Key Basic Research Program of China under Grant No 2006CB806004, the National Natural Science Foundation of China under Grant Nos 10675155 and 10834008, Scientific Research Foundation for Awarder of Excellent Doctor Thesis, and President Award of Chinese Academy of Sciences (No 0801051-X00).
文摘Two dimensional particle-in-cell simulations are taken to study the interaction of a circularly polarized laser pulse with a nano-scale micro-structured target. The protons which are doped in the rear side of the target experience the electrostatic fields caused by both the radiation pressure driven shock and the target normal sheath at the rear side of the target. A quasimonoenergetic proton bunch with central energy of about 11MeV and energy spread of ∆ ε/ε about 0.18 is achieved by using a 3.45×1019 W/cm2, 66fs laser pulse. A comparison with the case of linearly polarized laser pulse and the same target condition is considered.
文摘A 30-MeV femto-second electron linac is built at the Shanghai Institute of Applied Physics, which can produce high power, coherent THz undulator radiation. We report the experimental facility and measurement of the power, frequency spectrum. First experiments show the averaged power at THz to be about 20mW.
基金Supported by the National Natural Science Foundation of China under Grant No 10775009.
文摘Beam dynamics and rf designs of a 104 MHz ladder type IH-RFQ (L-IH-RFQ) accelerator are finished at Peking University for the acceleration of 14C+ from 40 keV to 500 keV. As a specific feature, the output beam energy spread is as low as 0.6% achieved with the internal discrete bunching method, which makes potential applications of RFQ feasible, such as accelerator mass spectrometry and ion implantation. Tolerances of the beam dynamics design are studied by means of changing the input beam parameters, and the results are quite satisfying. On the other hand, the L-IH-RFQ structure is employed, taking advantage of its mechanical stability and the absence of inter-electrode voltage asymmetry. Radio-frequency properties are studied and optimized for reducing power loss with Microwave Studio (MWS). Tuning of the field flatness and frequency is investigated in principle.
基金Supported by the Foundation of China Academy of Engineering Physics under Grant No 10576040, and the National Natural Science Foundation of China under Grant No 10705054.
文摘Accelerator mass spectrometry (AMS) is one of the most promising methods to detect minute amounts of 182Hf. However, the sensitivity of 5×10^-11 for ^182Hf/180Hf obtained previously by the AMS method at China Institute of Atomic Energy (CIAE) cannot meet the requirement of some applications. We present some new improvements of measurement method for AMS measurement of 182Hf at the CIAE HI?13 tandem accelerator system. As a result, a sensitivity of 1.0×10^-11 for 182Hf/180Hf is achieved.
基金Supported by the National Natural Science Foundation of China under Grant Nos 10734140, 10874156 and 10875109.
文摘An experimental measurement of radiatively heated iron plasma transmission spectra was performed on Shenguang II laser facility. In the measurement, the self?emission spectrum, the backlighting spectrum, and the absorption spectrum were imaged with a flat filed grating and recorded on a gated micro channel plate detector to obtain the time-resolved transmission spectra in the range 10-20 ? (approximately 0.6-1.3 keV). Experimental results are compared with the calculation results of an unsolved transition array (UTA) code. The time-dependent relative shift in the positions of the 2p-3d transmission array is interpreted in terms of the plasma temperature variations.
文摘For heating the tokamak plasma effectively, the ion source must be capable of producing ions with high proton ratio. The proton ratio, which is found to be more than 65.6% at the ion current of 19.6A with the extraction voltage of 39.6 k V, is measured with an image spectrograph by Doppler shift effect of Balmer-α-radiation spectrum emitted from fast hydrogen particles. The tendency of proton ratio with the ion density in experiment is almost the same as the mode devised by Zhang et al. Okumura et al. only gave the affection of the plasma volume and ion loss area on the proton ratio, but the relationship between the ion density in chamber and the proton ratio was not presented. We give the relationship.
文摘Specific activity of primordial radionuclides and associated radiation hazards due to 40K, 226Ra, and 232Th have been measured in backed red brick samples, collected from five highly populated areas of the North West Frontier Province of Pakistan. For the detection, analysis and data acquisition, a high purity germanium detector was used. Associated external doses were calculated using a Monte Carlo neutron photon transport code. A theoretical model to determine the gamma dose rate at 1 m height from the floor, made of bricks, was employed for the calculation of mass attenuation coefficient and self-absorption in the floor for the gamma energies of these radionuclides and their progeny. Monte Carlo simulation shows that in this study the floor, having more than an effective thickness of 15 cm, contributes very little to the external gamma dose rate. The values of the external dose rate and annual effective dose are found to be much lower than the world average as well as from other countries of the world.