Transient Analysis of Steam Generator in PWR Nuclear Power Plant 被引量:1
1
作者 M.Tahir Khaleeq Lang Wengpeng He Guoseng (School of Automation) 《Advances in Manufacturing》 SCIE CAS 1998年第2期43-50,共8页
The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics... The water level control system of steam generator in a pressurized water reactor of nuchear power plant plays an important role which effects the water level control of the steam generator are due the reverse dynamics behavior,so the transient analysis of the steam generator should firstly solve their mathematical models.For determination of dynamic behavior and design and testing of the control system, a nonlinear math model is developed using one dimensional conservation equations of mass,momentum and energy of primary and secondary sides of the steam generator. The nonlinear model is verified with standard power plant data available in the references, then the steady states and transient calculations are performed for full power to 5% power reactor operation of the steam generator of Chinese Qinshan Nuclear Power Plant. 展开更多
关键词 nuclear power plant steam generator nonlinear mathematical model qinshan nuclear powerplant