Taking Shenzhen city as an example, the statistical and physical relationship between the density of pollutants and various atmospheric parameters are analyzed in detail, and a space-partitioned city air pollution pot...Taking Shenzhen city as an example, the statistical and physical relationship between the density of pollutants and various atmospheric parameters are analyzed in detail, and a space-partitioned city air pollution potential prediction scheme is established based on it. The scheme considers quantitatively more than ten factors at the surface and planetary boundary layer (PBL), especially the effects of anisotropy of geographical environment, and treats wind direction as an independent impact factor. While the scheme treats the prediction equation respectively for different pollutants according to their differences in dilute properties, it considers as well the possible differences in dilute properties at different districts of the city under the same atmospheric condition, treating predictions respectively for different districts. Finally, the temporally and spatially high resolution predictions for the atmospheric factors are made with a high resolution numerical model, and further the space-partitioned and time-variational city pollution potential predictions are made. The scheme is objective and quantitative, and with clear physical meaning, so it is suitable to use in making high resolution air pollution predictions.展开更多
A microscale air pollutant dispersion model system is developed for emergency response purposes. The model includes a diagnostic wind field model to simulate the wind field and a random-walk air pollutant dispersion m...A microscale air pollutant dispersion model system is developed for emergency response purposes. The model includes a diagnostic wind field model to simulate the wind field and a random-walk air pollutant dispersion model to simulate the pollutant concentration through consideration of the influence of urban buildings. Numerical experiments are designed to evaluate the model's performance, using CEDVAL (Compilation of Experimental Data for Validation of Microscale Disper- sion Models) wind tunnel experiment data, including wind fields and air pollutant dispersion around a single building. The results show that the wind model can reproduce the vortexes triggered by urban buildings and the dispersion model simulates the pollutant concentration around buildings well. Typically, the simulation errors come from the determination of the key zones around a building or building cluster. This model has the potential for multiple applications; for example, the prediction of air pollutant dispersion and the evaluation of environmental impacts in emergency situations; urban planning scenarios; and the assessment of microscale air quality in urban areas.展开更多
文摘Taking Shenzhen city as an example, the statistical and physical relationship between the density of pollutants and various atmospheric parameters are analyzed in detail, and a space-partitioned city air pollution potential prediction scheme is established based on it. The scheme considers quantitatively more than ten factors at the surface and planetary boundary layer (PBL), especially the effects of anisotropy of geographical environment, and treats wind direction as an independent impact factor. While the scheme treats the prediction equation respectively for different pollutants according to their differences in dilute properties, it considers as well the possible differences in dilute properties at different districts of the city under the same atmospheric condition, treating predictions respectively for different districts. Finally, the temporally and spatially high resolution predictions for the atmospheric factors are made with a high resolution numerical model, and further the space-partitioned and time-variational city pollution potential predictions are made. The scheme is objective and quantitative, and with clear physical meaning, so it is suitable to use in making high resolution air pollution predictions.
基金supported by the National Natural Science Foundation of China (Grant No. 41375014)the National Basic Research Program of China (Grant No. 2011CB 952002)Jiangsu Collaborative Innovation Center for Climate Change, China
文摘A microscale air pollutant dispersion model system is developed for emergency response purposes. The model includes a diagnostic wind field model to simulate the wind field and a random-walk air pollutant dispersion model to simulate the pollutant concentration through consideration of the influence of urban buildings. Numerical experiments are designed to evaluate the model's performance, using CEDVAL (Compilation of Experimental Data for Validation of Microscale Disper- sion Models) wind tunnel experiment data, including wind fields and air pollutant dispersion around a single building. The results show that the wind model can reproduce the vortexes triggered by urban buildings and the dispersion model simulates the pollutant concentration around buildings well. Typically, the simulation errors come from the determination of the key zones around a building or building cluster. This model has the potential for multiple applications; for example, the prediction of air pollutant dispersion and the evaluation of environmental impacts in emergency situations; urban planning scenarios; and the assessment of microscale air quality in urban areas.