Left atrial appendage occluder detachment treated with transthoracic ultrasound combined with digital subtraction angiography guided catcher:A case report
1
作者 Kai Yu Yun-Hua Mei 《World Journal of Clinical Cases》 SCIE 2024年第6期1157-1162,共6页
BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innova... BACKGROUND There are very few cases of cardiac occluder detachment,and it is rare to completely remove the occluder using interventional methods without undergoing thoracotomy surgery after detachment.This case innovatively used ultrasound guidance combined with digital subtraction angiography(DSA)to completely remove the occluder,accumulating some experience.CASE SUMMARY The patient underwent left atrial appendage occlusion surgery in our hospital due to atrial fibrillation.After the surgery,the occluder fell off and became free in the left ventricle,which is very dangerous.We innovatively used ultrasound guidance,combined with DSA,and interventional surgery to successfully capture the free occluder using a catcher,completely remove it,and then re implant a new left atrial appendage occluder.After the surgery,the patient recovered very well.CONCLUSION The size selection of the occluder is slightly conservative,and the shape of the left atrial appendage opening is irregular. 展开更多
关键词 Left atrial appendage occluder DETACHMENT Ultrasound combined with digital subtraction angiography Interventional operation Successfully captured Case report
下载PDF
Safety and Efficacy of Biodegradable Patent Foramen Ovale Occluder in Patients with Migraine:A Clinical Trial
2
作者 Xingbang Li Xuan Zheng +10 位作者 Bowen Jin Yunyan Li Yongyu Shao Xiaoxian Deng Dingyang Li Shanshan Li Hongmei Zhou Jie Zhang Xianya Zhang Qunshan Shen Gangcheng Zhang 《Congenital Heart Disease》 SCIE 2023年第3期373-385,共13页
Background:Transcatheter closure of patent foramen ovale(PFO)has been widely accepted as a highly effective way to treat high-risk PFO-related diseases.However,traditional non-degradable occluders made of metal alloys... Background:Transcatheter closure of patent foramen ovale(PFO)has been widely accepted as a highly effective way to treat high-risk PFO-related diseases.However,traditional non-degradable occluders made of metal alloys will permanently exist in the body,resulting in thrombosis,valve damage,hemolysis,arrhythmia,or other complications.The biodegradable PFO occluder developed by Shanghai Mallow Medical Instrument Co.,Ltd.,China can be fully absorbed and degrade into nontoxic ingredients,reducing postoperative complications.Objectives:To study the safety and efficacy of biodegradable PFO occluders in treating PFO.Methods:This single-center clinical trial collected 30 patients treated with a biodegradable PFO occluder.The follow-up period lasted 12 months to analyze the echocardiographic characteristics and headache relief through HIT-6 scores.Results:The immediate success rate was 100%,with no intraoperative severe occlusion-related complications.The contrast transcranial Doppler(cTCD)at 12 months showed that all patients’right-to-left shunts(RLS)were grade I or 0 with no serious postoperative complications,indicating the overall success rate was 100%.The biodegradable PFO occluder mostly degraded six months after the occlusion.Conclusion:PFO closure with a Mallow biodegradable occluder is safe and effective and has no severe complications. 展开更多
关键词 Patent foramen ovale biodegradable occluder transcatheter closure MIGRAINE COMPLICATIONS
下载PDF
Effectiveness and Safety of Transcatheter Closure of Various Ventricular Septal Defects Using Second-Generation Amplatzer Duct Occluders
3
作者 Jianming Wang Qiguang Wang +3 位作者 Xiaotang Sheng Jingsong Geng Jiawang Xiao Xianyang Zhu 《Congenital Heart Disease》 SCIE 2023年第2期183-195,共13页
Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to ... Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients. 展开更多
关键词 Ventricular septal defects Amplatzer Duct occluder II long-term follow-up transcatheter closure
下载PDF
Biodegradation of occluded hydrocarbons and kerogen macromolecules of the Permian Lucaogou shales,Junggar Basin,NW China
4
作者 Yan'e Chen Longlong Li +2 位作者 Zhirong Zhang Paul F.Greenwood Yumin Liu 《Energy Geoscience》 2023年第1期179-184,共6页
Three kerogen samples(JJZG-1,JJZG-2 and JJZG-3)isolated from the Permian Lucaogou shales of varying biodegradation levels(BLs≈0,3 and 7,respectively)were subjected to sequential stepwise pyrolysis combined with on-li... Three kerogen samples(JJZG-1,JJZG-2 and JJZG-3)isolated from the Permian Lucaogou shales of varying biodegradation levels(BLs≈0,3 and 7,respectively)were subjected to sequential stepwise pyrolysis combined with on-line detection of gas chromatography-mass spectrometry(GC-MS).Occluded fractions(bitumenⅡ)released at low-temperature steps(≥410℃)show consistent biodegradative signatures with that reported for solvent-extracted fractions(bitumenⅠ)of the original shales,e.g.,broad range of abundant n-alkanes,isoprenoids and regular hopanes for the non-biodegraded JJZG-1;trace n-alkanes and abundant hopanes for the moderately biodegraded JJZG-2;and no n-alkanes but still prominent hopanes including the microbially produced 25-nohopanes for the severely biodegraded JJZG-3.This consistency between bitumenⅡand bitumenⅠfractions indicates the biodegradability of the kerogenoccluded bitumenⅡwith limited protection from host kerogen.A minor level of protection was suggested by the trace distribution of n-alkanes in the bitumenⅡof JJZG-2,whereas the bitumenⅠhad no nalkanes.The kerogen itself was more resistant to biodegradation as reflected by the persistence of high abundances of both n-alkanes and hopanes in the high temperature(≥460℃)products of all three kerogen samples.However,the relative abundances of these product groups did show some evidence of biodegradation alteration,e.g.,ratios of n-C_(15)alkene/C_(27)hop-17(21)-ene at 510℃pyrolysis decreased by order of magnitude from the non-biodegraded(JJZG-1=27.4)to highly biodegraded(0.3 for JJZG-3)samples.The reduced biodegradation impact on the kerogen fraction(Cf.bitumen fractions)was also evident by the absence of 25-norhopanes in the high-temperature analysis of the JJZG-3 kerogen. 展开更多
关键词 BIODEGRADATION Stepwise pyrolysis occluded hydrocarbon BitumenⅡ KEROGEN Source rock Permian Lucaogou shale Junggar Basin
下载PDF
Isolated Major Aortopulmonary Collateral Artery Causing Heart Failure: Transcatheter Occlusion of Mapcas Using Amplatzer Vascular Plugs and Amplatzer Piccolo Occluders
5
作者 Vakhtang Khelashvili Iuri Fkhkadze +1 位作者 Tengiz Shiryaev Omar Gogia 《World Journal of Cardiovascular Diseases》 2023年第11期701-709,共9页
Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmon... Major aortopulmonary collateral arteries (MAPCAs) are congenital vessels that arise from the aorta or its first-order branches and are distally connected to the pulmonary arterial vasculature, thereby providing pulmonary blood flow. MAPCAs are often associated with cyanotic congenital heart disease with decreased pulmonary blood flow. Isolated MAPCAs are rare in patients without congenital heart disease with structurally normal hearts. Sometimes, isolated congenital MAPCAs can occur without any lung disease. Isolated MAPCAs represent the occurrence of collaterals in the absence of underlying heart disease, which commonly presents as heart failure, recurrent respiratory tract infection, and pulmonary artery hypertension. We report a rare case of congestive heart failure in a 6-year-old patient with dual arterial supply to an otherwise normal right lung, with a normal bronchial tree, and a structurally normal heart. The patient was successfully managed by the closure of collaterals by Amplatzer vascular plugs II (AVPII) and Amplatzer Piccolo Occluders. 展开更多
关键词 Isolated Major Aortopulmonary Collateral Artery Amplatzer Vascular Plugs Amplatzer Piccolo occluder Mapcas Transcatheter Closure
下载PDF
Management of an occluded biliary metallic stent 被引量:6
6
作者 Wiriyaporn Ridtitid Rungsun Rerknimitr 《World Journal of Gastrointestinal Endoscopy》 CAS 2012年第5期157-161,共5页
In patients with a malignant biliary obstruction who require biliary drainage,a self-expandable metallic stent(SEMS) provides longer patency duration than a plastic stent(PS).Nevertheless,a stent occlusion by tumor in... In patients with a malignant biliary obstruction who require biliary drainage,a self-expandable metallic stent(SEMS) provides longer patency duration than a plastic stent(PS).Nevertheless,a stent occlusion by tumor ingrowth,tumor overgrowth and biliary sludge may develop.There are several methods to manage occluded SEMS.Endoscopic management is the preferred treatment,whereas percutaneous intervention is an alternative approach.Endoscopic treatment involves mechanical cleaning with a balloon and a second stent insertion as stent-in-stent with either PS or SEMS.Technical feasibility,patient survival and cost-effectiveness are important factors that determine the method of re-drainage and stent selection. 展开更多
关键词 occluded BILIARY METALLIC STENT Re-drainage COST EFFECTIVENESS
下载PDF
Safety of an improved patent ductus arteriosus occluder for transcatheter closure of perimembranous ventricular septal defects with abnormally attached tricuspid chordae tendineae 被引量:2
7
作者 Lu He Ya-Juan Du +1 位作者 Ge-Sheng Cheng Yu-Shun Zhang 《World Journal of Clinical Cases》 SCIE 2019年第5期562-571,共10页
BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid r... BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid regurgitation(TR),associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable.AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus(PDA) occluder.METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed.RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted. 展开更多
关键词 Ventricular SEPTAL defect TRANSCATHETER PATENT ductus arteriosus occlude TRICUSPID REGURGITATION Chordae tendineae
下载PDF
Safety and efficacy of amplatzer duct occluder for percutaneous closure of ventricular septal defects with tunnel shape aneurysm: Medium term follow up 被引量:1
8
作者 Muhammad Dilawar Zaheer Ahmad 《World Journal of Cardiovascular Diseases》 2013年第2期228-233,共6页
Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventric... Objectives: Different devices including Amplatzer duct occluder has been used for percutaneous closure of ventricular septal defects. This study reports our medium term follow up of perimembranous and muscular ventricular septal defects with tunnel shape aneurysm closure using the Amplatzer duct occluder. Materials and Methods: From May 2006-December 2012, we used Amplatzer duct occluder in seven ventricular septal defect patients here atHamad General Hospital,Doha,Qatar. There were 4 male and 3 female patients with an age range of 4 - 32 years with a median of 8 years and weight range of 16 - 63 kgwith a median of33 kg. In this group, 6 were perimembranous and 1 muscular and all these ventricular septal defects had a tunnel shape aneurysm. Transesophageal echocardiographic diameter ranged from 4 - 8 mmand Qp/Qs was 1 - 1.6. Angiographically, the diameter on the left ventricular side measured 3.5 - 10 mmand on right ventricular side 2.4?- 5 mm. 8/6 mmAmplatzer duct occluder was used to close these ventricular septal defects. Results: There were no major complications and immediately after the procedure there was no residual shunt in any of these patients and all the patients remained in normal sinus rhythm. One patient was expatriate and no further follow up was available. The rest of the 6 patients had 1 - 80 months with a median of 54 months follow up and none of these patients had any residual shunt and all remained in normal sinus rhythm. Two patients developed trivial aortic valve regurgitation immediate post procedure, one remained unchanged and the 2nd has progressed to mild at this latest follow up. Conclusion: Amplatzer duct occluder is feasible and a safe device for percutaneous closure of selective tunnel shape aneurysmal perimembranous and muscular ventricular septal defects. 展开更多
关键词 VENTRICULAR SEPTAL Defect AMPLATZER DUCT occludeR ANEURYSM
下载PDF
Transcatheter Closure of a Right Pulmonary Artery to Left Atrium Fistula Using a Ventricular Septal Defect Occluder
9
作者 Diqi Zhu Xiaohong Gu +1 位作者 Jie Shen Fen Li 《Congenital Heart Disease》 SCIE 2021年第2期147-150,共4页
Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen sat... Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen saturation of 70%at admission.The echocardiogram indicated an abnormal color flow Doppler in the LA and she underwent standard cardiac catheterization.The angiography of pulmonary artery revealed a 7.4 mm×7.6 mm fistula between the RPA and LA and achieved successful closure using ventricular septal defect occlusion.Conclusion:The fistula between pulmonary artery and left atrium is an extremely rare but treatable congenital defect.It should be considered in differential diagnosis of cyanosis in children. 展开更多
关键词 Transcatheter closure FISTULA ventricular septal defect occlude central cyanosis
下载PDF
Occlusion of atrial septal defect utilizing occluder devise via minimally invasive right chest approach
10
作者 励峰 李伟 +5 位作者 康宁 龚宝生 吴东进 徐方杰 邱兆昆 吴卫华 《上海交通大学学报(医学版)》 CAS CSCD 北大核心 2011年第3期343-345,共3页
Objective To evaluate atrial septal defect(ASD) occlusion employing a small right anterior thoracotomy approach. Methods A total of 21 patients with ASD underwent general anesthesia and 2-3 cm incision was made in the... Objective To evaluate atrial septal defect(ASD) occlusion employing a small right anterior thoracotomy approach. Methods A total of 21 patients with ASD underwent general anesthesia and 2-3 cm incision was made in the fourth right intercostal space.Utilizing transesophageal or transthoracic echocardiography,the occluder was released using a monotube unit. Results All patients were occluded successfully.No patient required open surgery utilizing extracorporeal circulation.There were no major complications and no evidence of residual atrial shunt. Conclusion ASD occlusion via a minimal surgical incision is safe,less invasive,and has excellent outcomes. 展开更多
关键词 minimally invasive atrial septal defect occluder device
下载PDF
Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Amplatzer Duct Occluder II
11
作者 Hongxiao Sun Gang Luo +2 位作者 Zhanhui Du Zhixian Ji Silin Pan 《Congenital Heart Disease》 SCIE 2021年第2期151-157,共7页
Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had... Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had attempted transcatheter closure using ADO II,seven of patients were used antegrade approach and six of them were used retrograde approach.Results:There were 8 males and 5 females,age from 1 to 7 years,weight from 10.5 to 31.0 kg,and VSD size from 2.0 to 4.0 mm.Procedure was successful in all cases with the outer diameter of the occluders ranging from 4 to 6 mm.No aortic,tricuspid regurgitation or residual shunt was found in the immediate ultrasound assessment.No arrhythmia was observed in the Holter monitoring 3 days after the intervention.Discharge echocardiography indicated complete shunt closure.No evidence of occluder prolapse,malignant arrhythmia,or intensed valve regurgitation was seen on a median follow-up of 18 months(range,6 to 36 months).Conclusions:Based on our experience,ADO II showed good efficacy in the early and middle stages of pediatric pmVSD closures. 展开更多
关键词 Ventricular septal defect transcatheter closure Amplatzer duct occluder CHILDREN
下载PDF
Completed atrioventricular block induced by atrial septal defect occluder unfolding:A case report
12
作者 Chuan He Yang Zhou +2 位作者 Si-Si Tang Li-Hong Luo Kun Feng 《World Journal of Clinical Cases》 SCIE 2020年第22期5715-5721,共7页
BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial se... BACKGROUND An atrial septal defect is a common condition and accounts for 25%of adult congenital heart diseases.Transcatheter occlusion is a widely used technique for the treatment of secondary aperture-type atrial septal defects(ASDs).CASE SUMMARY A 30-year-old female patient was diagnosed with ASD by transthoracic echocardiography(TTE)1 year ago.The electrocardiogram showed a heart rate of 88 beats per minute,normal sinus rhythm,and no change in the ST-T wave.After admission,TTE showed an atrial septal defect with a left-to-right shunt,aortic root short-axis section with an ASD diameter of 8 mm,a parasternal four-chamber section with an ASD diameter of 9 mm,and subxiphoid biatrial section with a diameter of 13 mm.Percutaneous occlusion was proposed.The intraoperative TTE scan showed that the atrial septal defect was oval in shape,was located near the root of the aorta,and had a maximum diameter of 13 mm.A 10-F sheath was placed in the right femoral vein,and a 0.035°hard guidewire was used to establish the transport track between the left pulmonary vein and the inferior vena cava.A shape-memory alloy atrial septal occluder with a waist diameter of 20 mm was placed successfully and located correctly.TTE showed that the double disk unfolded well and that the clamping of the atrial septum was smooth.Immediately after the disc was revealed,electrocardiograph monitoring showed that the ST interval of the inferior leads was prolonged,the P waves and QRS waves were separated,a junctional escape rhythm maintained the heart rate,and the blood pressure began to decrease.After removing the occluder,the elevation in the ST segment returned to normal immediately,and the sinus rhythm returned to average approximately 10 min later.After consulting the patient’s family,we finally decided to withdraw from the operation.CONCLUSION Compression of the small coronary artery,which provides an alternative blood supply to the atrioventricular nodule during the operation,leads to the emergence of a complete atrioventricular block. 展开更多
关键词 Completed atrioventricular block Atrial septal defect occluder Atrial septal defect Transthoracic echocardiography Case report
下载PDF
Studies on the Construction Parameter of an Artificial Occluded Cell for In-situ Inspection of the Propagation Rate of Localized Corrosion
13
作者 Liangcai LEI, Fengping WANG, Yanmin GAO and Yuanlong DU State Key Lab for Corrosion and Protection, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China To whom correspondence should be addressed Present address: Department of 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2001年第3期355-358,共4页
An artificial localized corrosion system is assembled and some parameters related to the localized corrosion in active dissolution state (i.e., non-passive state) have been studied. The results showed that the develop... An artificial localized corrosion system is assembled and some parameters related to the localized corrosion in active dissolution state (i.e., non-passive state) have been studied. The results showed that the developed electrochemical system can satisfactorily imitate a naturally formed localized corrosion and the coupling current can indicate the maximum localized propagating rate. In this artificial system, the anodic dissolution reaction followed the auto-catalytic mechanism. The localized corrosion current density was dependent on the area ratio R of the cathode to the occluded anode. While R was equal to or more than 6, the coupling current reached at a maximum value and did not alter with the increase in R-value. Therefore, R=7 is chosen as one of these optimum parameters used in constructing the system, with which the biggest galvanic current might be obtained. In contrast, the thickness of the polymer filler separating the occluded anode area from the bulk electrolyte solution and the volume of the occluded anode area did not affect the corrosion current obviously. They might affect the response time to approach a steady state. 展开更多
关键词 In Cell Studies on the Construction Parameter of an Artificial occluded Cell for In-situ Inspection of the Propagation Rate of Localized Corrosion UNS
下载PDF
TRANSCATHETER CLOSURE OF LARGE SECUNDUM ATRIAL SEPTAL DEFECTS WITH AMPLATZER~ SEPTAL OCCLUDER
14
作者 杨震坤 Aubry Pierre +1 位作者 Eric Brochet Jean-Michel Juliard 《Medical Bulletin of Shanghai Jiaotong University》 CAS 2010年第1期40-46,共7页
Objective To evaluate the safety and feasibility of transcatheter closure of large secundum atrial septal defects(ASDs)with Amplatzer~ septal occluder(ASO).Methods A total of 26 patients(age 16 to 67 years,median 43... Objective To evaluate the safety and feasibility of transcatheter closure of large secundum atrial septal defects(ASDs)with Amplatzer~ septal occluder(ASO).Methods A total of 26 patients(age 16 to 67 years,median 43 years;body weight 52 to 102 kg,median 67 kg)with large ASDs underwent an attempted transcatheter closure using ASO.Large ASD was defined as those with a balloon-stretched diameter of ≥30 mm.Another 81 patients with small-to-moderate ASD during same period who underwent closure served as controls.Results In patients with large ASDs,the ASD dimension means were(22.1±3.2)mm(range from 16 to 30 mm)and(23.8±2.6)mm(range from 18 to 31mm)assessed by transesophageal echocardiography(TEE)and transthoracic echocardiography(TTE),respectively.The mean balloon-stretched diameter of the ASD was(31.9±2.1)mm(range from 30 to 37mm).The size of device was(32.0±1.9)mm(range from 30 to 36mm).The transcatheter procedure was successful in all patients(100%).Seventeen deployments were performed using the conventional left atrium approach,and remaining 9 patients required the right upper pulmonary vein approach.Immediately after deployment,TEE revealed that complete closure rate was 73%.Procedure-related complications were recorded in 3 patients(12%),including device embolization in one patient,pericardial effusion in one patient,and large hematoma at puncture site in one patient.During follow-up,the complete closure rate increased to 88% at 24h after procedure and 100% at 6 months.The procedural success rates,immediate TEE results and TTE results at 24h and 6 months after procedure,were not significantly different between patients with large ASDs and those with small-to-moderate ASDs.Conclusion Transcatheter closure of large ASDs using ASO is technical feasible and relatively safe.Proper care selection and specific technique modification such as the right upper pulmonary vein approach is vital for the implantation success. 展开更多
关键词 atrial septal defect transcatheter closure Amplatzer septal occluder
下载PDF
Very large aortic pseudoaneurysm repair using a septal occluder
15
作者 Paulo R.A.Caramori Ricardo Lasevitch +5 位作者 Mauricio L.Suksteris Ricardo M.Pianta Joao B.Petracco Fabiano Ramos Fabio M.Velho Felipe S.Torres 《Discussion of Clinical Cases》 2021年第2期14-17,共4页
A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous interven... A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous intervention with stenting of the graft followed by closure of the pseudoaneurysm using an atrial septal defect occluder was successfully carried out. 展开更多
关键词 Ascending aorta PSEUDOANEURYSM Percutaneous repair Septal occluder
下载PDF
The Changes of Left Ventricular Form and Function After Closure of Moderate-to Large-sized Patent Ductus Arteriosus Using Domestic-made Occluder
16
作者 莫剑梅 伍伟锋 +4 位作者 刘唐威 黄凯 郭盛兰 张炳东 吴棘 《South China Journal of Cardiology》 CAS 2005年第2期106-108,共3页
Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underw... Objectives To evaluate the changes of the left ventricular form and function after closure of moderate- to large-sized patent ductus arteriosus (PDA) using domestic-made occluder. Methods 22 patients with PDA underwent procedure successfuly using the domestic-made occluder. The mean PDA minimal (pulmonary end) diameter by aortography was 8.01±2.47 mm (range 4 to 15.5mm). All patients underwent transthoracic echocardiography (TTE) study before the procedure and the following 48 hours, 3 months after procedure. Results All patients had been implanted the domestic-made occluders successfully with no haematolysis, infective endocarditis, recanalization and other complications. At 3 months, mean LVED was decreased to 50.05±6.55 mm, compared to the pre-procedure (55.67 ±8.48 mm), P 〈 0.01. After 48 hours of the procedure, mean LVEDD and LVESD decreased significantly (156.22± 51.40 mL vs. 121.28±35.73ml, 57.16±32.07 mL vs. 45.88±15.97 mL), P〈 0.05. At 3 months, LVEDD decreased to 110.93 ±15.08ml, LVSV reached 73.50± 9.19 mL, compared to the pre-procedure, P 〈 0.01. LVESD decreased to 37.43±10.44 mL at 3 months, P〈 0.05. Conclusions Closuring of moderate- to largesized PDA using domestic-made occluder is effective and safe. After procedure, left ventricular form and function improved. 展开更多
关键词 Patent ductus arteriosus Heart catheterization occluder device
下载PDF
Clinical Study on Amplatzer Occluder Device to CloseVentricular Septal Defect
17
作者 籍振国 刘刚 刘坤申 《South China Journal of Cardiology》 CAS 2005年第2期109-112,121,共5页
Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 wit... Objectives To evaluate the therapeutic effect of transcatheter Amplatzer device on the closure of ventricular septal defect (VSD). Methods Among 143 patients with VSD, 135 patients with perimembrane VSD and 2 with muscular VSD aged 2.5 -28 years old, were successfully closed with Amplatzer oeeluder device by the pereutaneous guidwire through femoral artery-VSD-femoral vein route under the guidance of fluoroscopy, ventrieulography and transthoracic echocardiography (TIE). The diameters of the VSDs were 2.3-15.7 (6.90±2.76)mm by left ventriculography. Results The success rate of transcatheter closure of VSD with Amplatzer devices was 96%(137/143). Minimal residual amount of shunts were found in one patient, although the shunts was decreased one month after the procedure. There were one patient who had respiratory arrest during the procedure, 7 patients(5%)had conduction disturbance, 3 patients had complete left bundle branch block, 2 patients had complete right bundle branch block, 1 patient had Ⅰ degree atrial-ventricular block and 1 patient had Ⅲ degree atr/al-ventricular block during hospitalization. The diameters of the occluder ranged from 4 to 23 (9.13±3.31)mm and were symmetrical in 122 patients and asymmetrical in 15 patients. Conclusions Transcatheter closure of the perimembranous ventrieular septal defect using Amplatzer VSD occluder device is an efficient method for patients with the perimembranous VSD. The operation is simple with a high success rate and a good effect. 展开更多
关键词 Congenital heart disease Ventricular septal defect Perimembranous Amplatzer occluder
下载PDF
A fully biodegradable polydioxanone occluder for ventricle septal defect closure 被引量:1
18
作者 Zefu Li Pengxu Kong +10 位作者 Xiang Liu Shuyi Feng Wenbin Ouyang Shouzheng Wang Xiaopeng Hu Yongquan Xie Fengwen Zhang Yuxin Zhang Rui Gao Weiwei Wang Xiangbin Pan 《Bioactive Materials》 SCIE CSCD 2023年第6期252-262,共11页
Ventricular septal defect(VSD)is one of the commonest congenital heart diseases(CHDs).Current occluders for VSD treatment are mainly made of nitinol,which has the risk of nickel allergy,persistent myocardial abrasion ... Ventricular septal defect(VSD)is one of the commonest congenital heart diseases(CHDs).Current occluders for VSD treatment are mainly made of nitinol,which has the risk of nickel allergy,persistent myocardial abrasion and fatal arrythmia.Herein,a fully biodegradable polydioxanone(PDO)occluder equipped with a shape line and poly-L-lactic acid PLLA membranes is developed for VSD closure without the addition of metal marker.PDO occluder showed great mechanical strength,fatigue resistance,geometry fitness,biocompatibility and degradability.In a rat subcutaneous implantation model,PDO filaments significantly alleviated inflammation response,mitigated fibrosis and promoted endothelialization compared with nitinol.The safety and efficacy of PDO occluder were confirmed in a canine VSD model with 3-year follow-up,demonstrating the biodegradable PDO occluder could not only effectively repair VSD,induce cardiac remodeling but also address the complications associated with metal occluders.Furthermore,a pilot clinical trial with five VSD patients indicated that all the occluders were successfully implanted under the guidance of echocardiography and no adverse events occurred during the 3-month follow-up.Collectively,the fully bioresorbable PDO occluder is safe and effective for clinical VSD closure and holds great promise for the treatment of structural CHDs. 展开更多
关键词 Polymer Congenital heart disease Ventricle septal defect Biodegradable occluder Tissue regeneration
原文传递
A review of occluded objects detection in real complex scenarios for autonomous driving 被引量:1
19
作者 Jiageng Ruan Hanghang Cui +3 位作者 Yuhan Huang Tongyang Li Changcheng Wu Kaixuan Zhang 《Green Energy and Intelligent Transportation》 2023年第3期65-77,共13页
Autonomous driving is a promising way to future safe,efficient,and low-carbon transportation.Real-time ac-curate target detection is an essential precondition for the generation of proper following decision and contro... Autonomous driving is a promising way to future safe,efficient,and low-carbon transportation.Real-time ac-curate target detection is an essential precondition for the generation of proper following decision and control signals.However,considering the complex practical scenarios,accurate recognition of occluded targets is a major challenge of target detection for autonomous driving with limited computational capability.To reveal the overlap and difference between various occluded object detection by sharing the same available sensors,this paper presents a review of detection methods for occluded objects in complex real-driving scenarios.Considering the rapid development of autonomous driving technologies,the research analyzed in this study is limited to the recent five years.The study of occluded object detection is divided into three parts,namely occluded vehicles,pedes-trians and traffic signs.This paper provided a detailed summary of the target detection methods used in these three parts according to the differences in detection methods and ideas,which is followed by the comparison of advantages and disadvantages of different detection methods for the same object.Finally,the shortcomings and limitations of the existing detection methods are summarized,and the challenges and future development prospects in this field are discussed. 展开更多
关键词 Autonomous driving occluded objects Object detection VEHICLES PEDESTRIANS Traffic signs
原文传递
Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects 被引量:10
20
作者 LI Gui-shuang KONG Guang-ming +4 位作者 JI Qiu-shang LI Ji-fu CHEN Yu-guo YOU Bei-an ZHANG Yun 《Chinese Medical Journal》 SCIE CAS CSCD 2008年第11期973-976,共4页
Background In China, transthoracic echocardiography (TTE) is popularly used for pre-intervention examination for atrial septal defect (ASD) and for guiding ASD closure. However, the ability to determine ASD size a... Background In China, transthoracic echocardiography (TTE) is popularly used for pre-intervention examination for atrial septal defect (ASD) and for guiding ASD closure. However, the ability to determine ASD size and the safety and efficacy of l-rE for guiding ASD closure still has not been widely accepted. This study aimed to evaluate the efficacy and safety of l-rE used before, during and after transcatheter ASD closure with Amplatzer septal occluders (ASO). Methods Sixty-eight subjects (15 men and 53 women; mean age (33.7±17.3) years) were enrolled. TTE was used to measure the diameters and guide transcatheter closure of ASD. The ASD was examined by long-axis view, basal short-axis view, apical four-chamber view and the subcostal view to observe position, diameter and relation with neighbouring structures. The largest diameter was selected as the reference diameter. Patients were divided into 3 groups according to the ASD reference diameter: 22 subjects with ASD diameter 4-14 mm (group A); 21 subjects with ASD diameter 15-20 mm (group B); and 25 subjects with ASD diameter 21-33 mm (group C). Results ASD was occluded successfully in groups A and B. In group C, occlusion failed in 2 cases; 1 case remained with a 3-mm residual shunt sustained until 6-month follow-up. However, at 6-month follow-up, no case of thromboembolism, ASO dislocation or death occurred in the three groups. The diameter of ASD measured by l-rE could accurately predict the ASO size that could successfully occlude the ASD, especially in patients with ASD 〈20 mm. The ASD diameter measured by l-rE correlated well with ASO size (r= 0.925, P〈0.001 ; r=0.976, P〈0.001 ; r=0.929, P〈0.001 respectively). Conclusions ASD diameter measured by l-rE can accurately estimate the size of the ASO needed for successful closure of ASD. The larger the ASD, the much larger the ASO needed. l-rE is a satisfactory guiding imaging tool for ASD closure. 展开更多
关键词 transthoracic echocardiography atrial septal defect Amplatzer septal occluder congenital heart disease
原文传递