期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Off-Isocenter Winston-Lutz Test for Stereotactic Radiosurgery/Stereotactic Body Radiotherapy 被引量:5
1
作者 Junfang Gao Xiaoqian Liu 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第2期154-161,共8页
The single-isocenter technique in linear accelerator-based stereotactic radiosurgery/stereotactic body radiotherapy (SRS/SBRT) has been broadly used to treat multiple lesions. However, quantitative study to verify tha... The single-isocenter technique in linear accelerator-based stereotactic radiosurgery/stereotactic body radiotherapy (SRS/SBRT) has been broadly used to treat multiple lesions. However, quantitative study to verify that the mechanical field center coincides with the radiation field center when both are off from the isocenter has never been performed. We developed an innovative method to measure this accuracy, called the off-isocenter Winston-Lutz test, and here we provided a practical clinical guideline to implement this technique. We used ImagePro V.6 to analyze images of a Winston-Lutz phantom obtained using a Varian 21EX linear accelerator with an electronic portal imaging device, set up as for single-isocenter SRS/SBRT for multiple lesions. We investigated asymmetry field centers that were 3 cm and 5 cm away from the isocenter, as well as performing the standard Winston-Lutz test. We used a special beam configuration to acquire images while avoiding collision, and we investigated both jaw and multileaf collimation. For the jaw collimator setting, at 3 cm off-isocenter, the mechanical field deviated from the radiation field by about 2.5 mm;at 5 cm, the deviation was above 3 mm, up to 4.27 mm. For the multileaf collimator setting, at 3 cm off- isocenter, the deviation was below 1 mm;at 5 cm, the deviation was above 1 mm, up to 1.72 mm, which was 72% higher than the tolerance threshold. These results indicated that the further the asymmetry field center is from the machine isocenter, the larger the deviation of the mechanical field from the radiation field, and the distance between the center of the asymmetry field and the isocenter should not exceed 3 cm in our clinic. We recommend that every clinic that uses linear accelerator, multileaf collimator-based SRS/SBRT perform the off-isocenter Winston-Lutz test in addition to the standard Winston-Lutz test and use their own deviation data to create planning guideline. 展开更多
关键词 off-isocenter winston-lutz test SRS SBRT
下载PDF
Winston-Lutz-Gao Test on the True Beam STx Linear Accelerator
2
作者 Junfang Gao Xiaoqian Liu 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2019年第1期9-20,共12页
In the linear accelerator-based stereotactic radio surgery (SRS) and stereotactic body radiotherapy (SBRT) programs, single isocenter-multiple metastases’ treatment has become more and more popular due to their high ... In the linear accelerator-based stereotactic radio surgery (SRS) and stereotactic body radiotherapy (SBRT) programs, single isocenter-multiple metastases’ treatment has become more and more popular due to their high efficiency in treatment time. However, the absence of a comprehensive quality assurance program is still the challenge for medical physicists. The Winston-Lutz-Gao test, which we developed two years ago, was performed for the first time on a True Beam STx (Varian Medical System) linear accelerator in this study. Beams were designed by Eclipse with gantry, collimator, and couch full rotations, and a 200-pound weight was placed on the couch to mimic real treatment. The “frameless SRS QA target pointer” from the Brainlab company, with a 3.5-mm metallic ball embedded in the center, was used as a phantom. Images were acquired by the portal imager built-in linear accelerator and analyzed directly by the Image browser in ARIA. We found that the farther the metastases were from the linac isocenter, the worse the congruence was between the beam mechanical and the radiation center. The farthest metastases should be within 6 cm from the linac isocenter per the AAPM TG-142 and American Society for Radiation Oncology (ASTRO) white paper criteria. To the best of our knowledge, this is the first off-isocenter Winston-Lutz test performed on a True Beam STx linear accelerator. 展开更多
关键词 winston-lutz-Gao test off-iso winston-lutz test Single Iso-Multiple Mets’ Treatment
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部