期刊文献+
共找到1,601篇文章
< 1 2 81 >
每页显示 20 50 100
Computer Controlled Polishing of the Off-axis Aspheric Mirrors 被引量:4
1
作者 ZHANG Xue jun,WENG Zhi cheng,ZHANG Zhong yu, WANG Quan dou,ZHANG Feng (Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130022, China) 《光学精密工程》 EI CAS CSCD 2001年第5期467-473,共7页
In this paper, the manufacturing and testing procedures to make large off-axis aspherical mirrors are presented. The difficulties in polishing and testing for both circular aperture and rectangular aperture mirrors ar... In this paper, the manufacturing and testing procedures to make large off-axis aspherical mirrors are presented. The difficulties in polishing and testing for both circular aperture and rectangular aperture mirrors are previewed, and a possible solution is given. The two mirrors have been polished by means of CCOS, and the final accuracy is 25nm rms for 770mm×210mm rectangular mirror and 20nm rms for φ600mm circular mirror. These results just meet the optical tolerances specified by the designer, and the manufacturing and testing procedures presented here show good ability to make the large off-axis aspherical mirrors. 展开更多
关键词 asphere computer-controlled POLISHING OPTICAL TESTING
下载PDF
Optimization-based mode selection scheme for OAM millimeter wave system in the off-axis misalignment case
2
作者 Haie Dou Lei Wang +1 位作者 Bin Kang Baoyu Zheng 《Digital Communications and Networks》 SCIE CSCD 2024年第1期101-108,共8页
Millimeter-wave transmission combined with Orbital Angular Momentum(OAM)has the advantage of reducing the loss of beam power and increasing the system capacity.However,to fulfill this advantage,the antennas at the tra... Millimeter-wave transmission combined with Orbital Angular Momentum(OAM)has the advantage of reducing the loss of beam power and increasing the system capacity.However,to fulfill this advantage,the antennas at the transmitter and receiver must be parallel and coaxial;otherwise,the accuracy of mode detection at the receiver can be seriously influenced.In this paper,we design an OAM millimeter-wave communication system for overcoming the above limitation.Specifically,the first contribution is that the power distribution between different OAM modes and the capacity of the system with different mode sets are analytically derived for performance analysis.The second contribution lies in that a novel mode selection scheme is proposed to reduce the total interference between different modes.Numerical results show that system performance is less affected by the offset when the mode set with smaller modes or larger intervals is selected. 展开更多
关键词 Orbital angular momentum Millimeter wave off-axis misalignment Mode selection Capacity
下载PDF
Collision off-axis position dependence of relativistic nonlinear Thomson inverse scattering of an excited electron in a tightly focused circular polarized laser pulse
3
作者 王禹博 杨青屿 +2 位作者 常一凡 林宗熠 田友伟 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期344-354,共11页
This paper presents a novel view of the impact of electron collision off-axis positions on the dynamic properties and relativistic nonlinear Thomson inverse scattering of excited electrons within tightly focused, circ... This paper presents a novel view of the impact of electron collision off-axis positions on the dynamic properties and relativistic nonlinear Thomson inverse scattering of excited electrons within tightly focused, circularly polarized laser pulses of varying intensities. We examine the effects of the transverse ponderomotive force, specifically how the deviation angle and speed of electron motion are affected by the initial off-axis position of the electron and the peak amplitude of the laser pulse. When the laser pulse intensity is low, an increase in the electron's initial off-axis distance results in reduced spatial radiation power, improved collimation, super-continuum phenomena generation, red-shifting of the spectrum's harmonic peak, and significant symmetry in the radiation radial direction. However, in contradiction to conventional understandings,when the laser pulse intensity is relatively high, the properties of the relativistic nonlinear Thomson inverse scattering of the electron deviate from the central axis, changing direction in opposition to the aforementioned effects. After reaching a peak, these properties then shift again, aligning with the previous direction. The complex interplay of these effects suggests a greater nuance and intricacy in the relationship between laser pulse intensity, electron position, and scattering properties than previously thought. 展开更多
关键词 relativistic nonlinear Thomson inverse scattering off-axis collision radiation angle distribution tightly focused laser pulse
下载PDF
Simultaneous detection of CH_(4)and CO_(2)through dual modulation off-axis integrated cavity output spectroscopy
4
作者 刘艺璇 王周兵 +3 位作者 韦欣欣 王静静 孟鑫 毛桂林 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第10期468-475,共8页
This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the of... This study established a novel method for the simultaneous detection of two-component gases.Radio frequency(RF)white noise disturbance laser current and wavelength modulation were simultaneously used to improve the off-axis integrated cavity output spectroscopy technique,and a high-precision dual modulation OA-ICOS(RF-WM-OA-ICOS)system was established.The two laser beams were coupled into one laser beam that was applied incident to the cavity of RF-WM-OA-ICOS system.The second harmonic signals of CH_(4)and CO_(2)gas simultaneously appeared in the rising or falling edge of a triangular wave.This method was used to measure CH_(4)and CO_(2)with different concentrations.The results indicated that the proposed system has high stability and can accurately and simultaneously measure the concentrations of CH_(4)and CO_(2),with an optimal integration time of 220 s.The minimum detection limit was 10 ppb for CH_(4)and 1.5 ppm for CO_(2).The corresponding noise equivalent absorption sensitivity values were calculated as 2.67×10^(-13)cm^(-1)·Hz^(-1/2)and 5.18×10^(-11)cm^(-1)·Hz^(-1/2),respectively.The proposed dual-component gas simultaneous detection method can also be used for high-precision simultaneous detection of other gases.Therefore,this study may serve as a reference for developing portable multicomponent gas analyzers. 展开更多
关键词 off-axis integrated cavity output spectroscopy wavelength modulation radio frequency(RF)white noise simultaneous detection
下载PDF
Characteristic Analysis of Off-Axis Meta-Lens
5
作者 Jingaowa Hu Yang Liu +4 位作者 Shangnan Zhao Lingjie Wang Haokun Ye Jianping Zhang Xin Zhang 《Optics and Photonics Journal》 2023年第6期87-96,共10页
Meta-lens are a new type of planar optical element that can flexibly manipulate the phase, polarization and amplitude of the beam, and are currently receiving a great deal of attention as they are easier to process an... Meta-lens are a new type of planar optical element that can flexibly manipulate the phase, polarization and amplitude of the beam, and are currently receiving a great deal of attention as they are easier to process and manufacture. Off-axis meta-lens are a special type of meta-lens with a certain degree of dispersion that can be used as a beam-splitting element, providing a unique and feasible way to realize micro-miniature instruments. We analyze the effects of different numerical apertures and off-axis angles on the spectral resolution, focusing efficiency and simulation results of off-axis meta-lens to provide ideas for subsequent research and application of off-axis meta-lens. A number of off-axis meta-lens with parameters NA = 0.408 α = 13°, NA = 0.18 α = 13°<sup></sup> and NA = 0.408 α = 20° were simulated through Lumerical software. The results show that the off-axis angle is related to the resolution;the larger the angle, the better the spectral resolution but the lower the focusing efficiency;when the numerical aperture is smaller, the smaller the coverage of the phase distribution, which will lead to a larger deviation between simulation and theory. The designer needs to balance the numerical aperture, off-axis angle and other parameters reasonably according to the requirements in order to achieve the desired effect. The findings of this study have important reference values for the theoretical analysis of off-axis meta-lens and the design of parameters in practical applications. . 展开更多
关键词 Meta-Lens off-axis Meta-Lens Simulation Analysis
下载PDF
Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System 被引量:11
6
作者 Yan Chen Xue Wang +1 位作者 Chuan-Di Zhou Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期914-918,共5页
AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four ... AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method. 展开更多
关键词 optical quality analysis system age-relatedcataract spherical lens aspherical lens objective scatteringindex
下载PDF
RESEARCH ON PARALLEL GRINDING METHOD OF NON-AXISYMMETRIC ASPHERIC LENS 被引量:8
7
作者 GuoYinbiao ChenBingkui +1 位作者 ZhangYi KatsuoSyoji 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2004年第1期149-151,共3页
In order to resolve the problems of machining non-axisymmetric aspheric lens,which is short of flexibility in mould grinding and needs high accuracy CNC machine center in globediamond wheel grinding, a new parallel gr... In order to resolve the problems of machining non-axisymmetric aspheric lens,which is short of flexibility in mould grinding and needs high accuracy CNC machine center in globediamond wheel grinding, a new parallel grinding method that utilizes common arc diamond wheel isput forward. Base on the approach calculation of machining locus, the advantages of parallelgrinding that machines non-axisymmetric aspheric lens by 2.5-axis CNC machine center have beenobtained. The results of grinding experiment show the new method can meet the need of grinding highaccuracy non-axisymmetric aspheric lens. 展开更多
关键词 Non-axisymmetric aspheric lens Parallel grinding Arc diamond wheel Machining error analysis
下载PDF
Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics 被引量:5
8
作者 Mohammad Taher Rajabi Sara Korouji +4 位作者 Mahgol Farjadnia Mohammad Naderan Mohammad Bagher Rajabi Bahram Khosravi Seyed Mehdi Tabatabaie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期565-568,共4页
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty... AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses. 展开更多
关键词 aspherical lenses higher order aberrations CATARACT intraocular lens
下载PDF
SOFTWARE-CONTROLLED SYSTEM OF ULTRA-PRECISION MACHINING AXISYMMETRIC ASPHERIC MIRROR 被引量:4
9
作者 GU0 Yinbiao  WEI Lizhen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第2期256-259,共4页
In order to improve machining accuracy and efficiency, a software-controlled system of ultra-precision machining for axisymmetric aspheric mirror, using techniques of error compensation, remote transmission and modul... In order to improve machining accuracy and efficiency, a software-controlled system of ultra-precision machining for axisymmetric aspheric mirror, using techniques of error compensation, remote transmission and modularization, is designed based on industrial PC, Windows 2000 work platform and Visual Basic 6.0. By experiments, this system realizes functions of ultra-precision machining, machining error compensation, remote data transmission and automatic data transformation among first machining, compensation machining and accuracy measurement. The actual application shows that error compensation improves machining accuracy, remote transmission improves machining efficiency while modularization avoids repeated work and improves design efficiency. Therefore, the system has met ultra-precision machining need for aspheric mirror. 展开更多
关键词 aspheric surface machining Error compensation Remote transmission Visual Basic
下载PDF
Personalized aspheric intraocular lens implantation based on corneal spherical aberration: a review 被引量:3
10
作者 Wei Du Wei Lou Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第11期1788-1792,共5页
With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses(IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attribute... With the evolution of cataract surgery from visual rehabilitation to refractive surgery, aspheric intraocular lenses(IOLs) are being increasingly used in the field of ophthalmology. This increased use can be attributed to negative or zero spherical aberrations with unique optical designs, which counteract some of the positive spherical aberrations of the cornea. These alterations reduce the total spherical aberration of human eyes and improve the visual acuity in patients with cataract postoperatively. At present, various types of aspheric IOLs are used worldwide. Although the implantation of aspheric IOL is beneficial to the patients who need correction of spherical aberrations, much controversy is still associated with ocular residual spherical aberrations that facilitate the best visual quality for patients postoperatively. In order to provide reference for future clinical work and scientific research, this report reviews the relationship between the ocular residual spherical aberration of human eyes and visual quality. 展开更多
关键词 CORNEAL spherical ABERRATION aspheric INTRAOCULAR LENS visual quality
下载PDF
Effect of intracorneal ring segment implantation on corneal asphericity 被引量:3
11
作者 Canan A.Utine Ziya Ayhan Ceren Durmaz Engin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第8期1303-1307,共5页
AIM: To evaluate the visual, refractive and corneal asphericity changes after intrastromal corneal ring segment(ICRS) implantation for visual rehabilitation of keratoconus.METHODS: A total of 42 eyes of 32 patient... AIM: To evaluate the visual, refractive and corneal asphericity changes after intrastromal corneal ring segment(ICRS) implantation for visual rehabilitation of keratoconus.METHODS: A total of 42 eyes of 32 patients were included. After creation of intrastromal tunnels of 5.01±0.03 mm inner diameter, 5.71±0.03 mm outer diameter and at 384.21±34.12 μm depth, 1 or 2 ICRS of 150-300 μm thickness and 90°-210° arc length were implanted. Changes in uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), refractive errors, mean simulated keratometry readings SimK_(avg), anterior and posterior corneal asphericity values(Q_(ant) and Q_(post), respectively) measured with Scheimpflug topography were evaluated retrospectively. RESULTS: There was a significant improvement in UDVA and CDVA, along with a significant decrease in refractive spherical equivalent(SE), cylinder and SimK_(avg) postoperatively(P〈0.001 for all). Mean Qant increased from-1.06±0.48 to-0.57±0.58 postoperatively(P〈0.001). Change in mean Qpost was insignificant(P=0.92). Postoperative changes in UDVA and CDVA were not correlated with the postoperative changes in SE and cylinder(P〉0.05 for all); but were correlated with the preoperative SimK_(avg) and Q_(ant) values(P〈0.001 for all). CONCLUSION: ICRS implantation seems to approximate the anterior corneal asphericity of "advanced prolate" shape to "optimal prolate" shape and an "ideal Q value" of-0.46; which may have a role in improved UDVA and CDVA postoperatively, besides decreased refractive cylinder values. 展开更多
关键词 cornea ectasia corneal asphericity intracomealring segments KERATOCONUS Q value
下载PDF
Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses:a meta-analysis 被引量:6
12
作者 Jian-Ping Liu Fan Zhang +2 位作者 Jiang-Yue Zhao Li-Wei Ma Jin-Song Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期690-695,共6页
AIMTo assess the visual outcomes of aspheric multifocal intraocular lenses (IOLs) compared with spherical multifocal IOL after cataract surgery.
关键词 aspheric multifocal intraocular lens uncorrected near visual acuity uncorrected distance visual acuity spherical multifocal intraocular lens higher order aberration META-ANALYSIS
下载PDF
Theoretical and Experimental Research on Error Analysis and Optimization of Tool Path in Fabricating Aspheric Compound Eyes by Precision Micro Milling 被引量:3
13
作者 CHEN Mingjun XIAO Yong +2 位作者 TIAN Wenlan WU Chunya CHU Xin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第3期558-566,共9页
Structure design and fabricating methods of three-dimensional (3D) artificial spherical compound eyes have been researched by many scholars. Micro-nano optical manufacturing is mostly used to process 3D artificial c... Structure design and fabricating methods of three-dimensional (3D) artificial spherical compound eyes have been researched by many scholars. Micro-nano optical manufacturing is mostly used to process 3D artificial compound eyes. However, spherical optical compound eyes are less at optical performance than the eyes of insects, and it is difficult to further improve the imaging quality of compound eyes by means of micro-nano optical manufacturing. In this research, nonhomogeneous aspheric compound eyes (ACEs) are designed and fabricated. The nonhomogeneous aspheric structure is applied to calibrate the spherical aberration. Micro milling with advantages in processing three-dimensional micro structures is adopted to manufacture ACEs. In order to obtain ACEs with high imaging quality, the tool paths are optimized by analyzing the influence factors consisting of interpolation allowable error, scallop height and tool path pattern. In the experiments, two kinds of ACEs are manufactured by micro-milling with different too path patterns and cutting parameter on the miniature precision five-axis milling machine tool. The experimental results indicate that the ACEs of high surface quality can be achieved by circularly milling small micro-lens individually with changeable cutting depth. A prototype of the aspheric compound eye (ACE) with surface roughness (Ra) below 0.12 p.m is obtained with good imaging performance. This research ameliorates the imaging quality of 3D artificial compound eyes, and the proposed method of micro-milling can improve surface processing quality of compound eyes. 展开更多
关键词 aspheric compound eyes (ACEs) micro milling tool path optimization
下载PDF
Clinical study inpatient-reported outcomes after binocular implantation of aspheric intraocular lens of different negative spherical aberrations 被引量:3
14
作者 Ze-Quan Xu Xu-Hua Song +2 位作者 Wen-Zhe Li Yan Dou Qiang Wu 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2017年第7期771-774,共4页
Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was ... Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was used. A total of 105 patients(210 eyes) were divided into three groups according to the type of IOLs: ZA9003(35 patients, 70 eyes), MCX11 ASP(35 patients, 70 eyes) or HQ-201HEP(35 patients, 70 eyes). The main outcome was scores of Catquest nine-item short-form questionnaire. Additional outcome was best corrected visual acuities, spherical aberration(SA) and total higher-order aberrations(HOAs). Results: The global score was significantly lower in the spherical IOL group than the aspherical IOL group of-020 μm SA(P < 0.05) and the aspherical IOL group of-027 μm SA(P < 0.05), and no significant difference was found in the global score between the aspherical IOL group of-020 μm SA than the aspherical IOL group of-027 μm SA(P > 0.05). Significant differences were also found in question 2, question 5, question 6 and question 8 between the spherical IOLs and the aspherical IOLs. Conclusion: Implantation of an aspherical IOL could improve vision-related quality of life compared with a spherical IOL. However, there were no statistically significant differences in vision-related quality of life between aspheric IOLs with different negative spherical aberrations. 展开更多
关键词 Catquest nine-item short-form Patient-reported outcomes Vision-related quality aspheric intraocular lens Spherical aberration
下载PDF
Comparison of visual quality after implantation of Al-UV and SN60WF aspheric intraocular lens 被引量:5
15
作者 Xuan Liao Ji-Yun Li +3 位作者 Qing-Qing Tan Jing Tian Jia Lin Chang-Jun Lan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第11期1727-1732,共6页
AIM:To compare the visual performance of pseudophakic eyes implanted with Al-UV and SN60WF aspheric intraocular lens(IOL),and to investigate the correlations between visual quality parameters and pupil size.METHODS:Th... AIM:To compare the visual performance of pseudophakic eyes implanted with Al-UV and SN60WF aspheric intraocular lens(IOL),and to investigate the correlations between visual quality parameters and pupil size.METHODS:This prospective comparative study included 105 eyes of 90 patients with age-related cataract who underwent uneventful phacoemulsification.The subjects were divided into two groups according to the implanted IOL type.Three months postoperatively,visual acuity and contrast sensitivity were measured,wave-front aberrations were assessed using a KR-IW aberrometer(Topcon),and objective optical quality parameters were performed using an optical quality analysis system-OQAS Il(Visiometrics).Independent sample Mest and Spearman correlation analysis were used for data analysis.RESULTS:There were no significant differences found in visual acuity,contrast sensitivity and visual quality parameters between the two groups(P>0.05).The measured intraocular spherical aberration(SA)in Al-UV IOL eyes of-0.19±0.05 pm was close to the designed SA value of-0.20 pm.The modulation transfer function cutoff,Strehl ratio and OQAS values were negatively correlated with pupil size in both groups(P<0.01).CONCLUSION:The subjective and objective visual quality in pseudophakic eyes with A1-UV and SN60WF IOLs are comparable.For aspheric IOL eyes,visual quality decreases with increasing pupil size. 展开更多
关键词 CATARACT aspheric intraocular lens visual quality pupil size
下载PDF
Study on Injection Moulding of High Precision Aspheric Plastic Lens 被引量:1
16
作者 TO Suet LEE Wing-bun 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 2002年第S1期132-,共1页
With the rapid development of information and multi me dia technologies, the demand for the optical plastic aspheric elements used in o pto-electronic devices, camera, optical disc and projector lens etc. has been i n... With the rapid development of information and multi me dia technologies, the demand for the optical plastic aspheric elements used in o pto-electronic devices, camera, optical disc and projector lens etc. has been i ncreased rapidly in the recent years. The key technologies of fabrication of asp heric plastic lens are the design and manufacturing moulds, selection of proper injection moulding equipment, and optimization of injection moulding parameters etc. In this paper, the effect of injection pressure, moulding temperature, cool ing time and injection speed on the surface profile of the lenses during injecti on and holding process is investigated. Surface quality of plastic lenses is mea sured by Talysurf Texture Measuring System. The experimental results showed that the injection pressure and moulding temperature are important parameters compar ing to cooling time and injection speed. A bit change of injection pressure or m oulding temperature will affect the property of the surface profile. Either incr easing injection pressure or mould temperature can achieve less shrinkage. Other wise, a lower injection pressure will produce more shrinkage, more air traps and a lower mould temperature results greater warp and higher shrinkage. The dynami c process of injection for optical plastic lenses is simulated by 3D Moldflow pl astic Insight software (MPI). The MPI will help us to optimize injection mouldin g parameters. 展开更多
关键词 injection moulding aspheric lens optical compon ent OPTIMIZATION
下载PDF
ASPHERICITY AND PROLATENESS OF LINEAR AND CIRCULAR MACROMOLECULES 被引量:1
17
作者 魏高原 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 1995年第3期204-209,共6页
The shape asymmetry of gaussian models of linear and circular macromolecules has been numerically investigated in terms of asphericity and prolateness parameters. These parameters are found to decrease with increasing... The shape asymmetry of gaussian models of linear and circular macromolecules has been numerically investigated in terms of asphericity and prolateness parameters. These parameters are found to decrease with increasing length for the macromolecule either confined to a plane or in three dimensions. The effect of dimensionality on these parameters is visible only for low dimensions and is generally weak. As dimensionality goes to infinity, it is found that asphericity and prolateness for both chains and rings approach slowly yet descendingly values of corresponding asphericity and prolateness factors, with the exception of the chain which shows a minimum value of asphericity when the embedding space has a dimensionality of four. 展开更多
关键词 asphericITY PROLATENESS MACROMOLECULAR SHAPE THEORY
下载PDF
Propagation of the off-axis superposition of partially coherent beams through atmospheric turbulence 被引量:5
18
作者 张恩涛 季小玲 吕百达 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第2期571-580,共10页
The propagation properties of the off-axis superposition of partially coherent beams through atmospheric turbulence and their beam quality in terms of the mean-squared beam width w(z) and the power in the bucket (... The propagation properties of the off-axis superposition of partially coherent beams through atmospheric turbulence and their beam quality in terms of the mean-squared beam width w(z) and the power in the bucket (PIB) are studied in detail, where the effects of partial coherence, off-axis beam superposition and atmospheric turbulence are considered. The analytical expressions for the intensity, the beam width and the PIB are derived, and illustrative examples are given numerically. It is shown that the maximum intensity/max and the PIB decrease and w(z) increases as the refraction index structure constant Cn^2 increases. Therefore, the turbulence results in a degradation of the beam quality. However, the resulting partially coherent beam with a smaller value of spatial correlation parameter γ and larger values of separate distance Xd and beam number M is less affected by the turbulence than that with a larger value of y and smaller values of Xd and M. The main results obtained in this paper are explained physically. 展开更多
关键词 off-axis superposition of partially coherent beams atmospheric turbulence propagation property beam quality
下载PDF
Off-axis multi-wavelength dispersion controllingmetalens for multi-color imaging 被引量:17
19
作者 Kaihua Dou Xin Xie +4 位作者 Mingbo Pu Xiong Li Xiaoliang Ma Changtao Wang Xiangang Luo 《Opto-Electronic Advances》 2020年第4期7-13,共7页
Dispersion control is crucial in optical systems,and chromatic aberration is an important factor affecting imaging quality in imaging systems.Due to the inherent property of materials,dispersion engineering is complex... Dispersion control is crucial in optical systems,and chromatic aberration is an important factor affecting imaging quality in imaging systems.Due to the inherent property of materials,dispersion engineering is complex and needs to trade off other aberration in traditional ways.Although metasurface offers an effective method to overcome these limits and results in well-engineered dispersion,off-axis dispersion control is still a challenging topic.In this paper,we design a single-layer metalens which is capable of focusing at three wavelengths(473 nm,532 nm,and 632 nm)with different incident angles(0°,-17°and 17°)into the same point.We also demonstrate that this metalens can provide an alternative for the bulky color synthetic prism in a 3-chips digital micromirror device(DMD)laser projection system.Through this approach,various off-axis dispersion controlling optical devices could be realized. 展开更多
关键词 off-axis DISPERSION control metalens COLOR imaging
下载PDF
Far-field vector-diffraction of off-axis parabolic mirror under oblique incidence 被引量:2
20
作者 曾夏辉 陈曦曜 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第3期190-201,共12页
Based on a full vector-diffraction theory, a detailed theoretical study is carried out, aiming at providing a clear insight into the effects of different focusing and off-axis parabola parameters on far-field vector-d... Based on a full vector-diffraction theory, a detailed theoretical study is carried out, aiming at providing a clear insight into the effects of different focusing and off-axis parabola parameters on far-field vector-diffraction properties of an offaxis parabolic mirror in the presence of misalignments of the incoming beam. The physical origin of these effects is also explored. The results show that the far-field intensity profile is altered by the distortion-, coma-, and astigmatism-like aberrations, which are caused by oblique incidence rather than inherent aberrations for the off-axis configuration. The radius of 90% encircled energy also increases but does not change monotonically with incident beam size increasing, or rather,it first decreases and then increases. The focal shift strongly depends on the effective focal length and oblique incidence angle, but it is almost independent of the beam size, which affects the focusing spot patterns. The intensity distribution produces a higher astigmatic image with off-axis angle increasing. Coma-like aberration starts to become dominant with beam size increasing and results in larger curved propagation trajectory. The incident polarization also affects the intensity distribution. The variation in the Strehl ratio with oblique incidence angle strongly depends on the misalignment direction and beam size as well. In addition, we find that the difference in locus between the catacaustic and the diffraction focus in the meridian is small. But the locus of the sagittal foci is obviously different from the locus of the meridian foci and the catacaustic focus. Moreover, the peak intensity of the sagittal focus is maximum, and the ratio of the peak intensity to that in the meridian plane is approximately 1.5. Understanding these effects is valuable for assessing a practical focused intensity and describing the motion of charged particles under a strong electric field in ultraintense laser–matter interaction. 展开更多
关键词 laser beam focusing off-axis PARABOLIC MIRROR vector-diffraction theory oblique incidence
下载PDF
上一页 1 2 81 下一页 到第
使用帮助 返回顶部