STUDY ON POWER SPARE COEFFICIENT OF ELECTRICAL MOTOR IN LARGE PUMP STATION BASED ON RELIABILITY 被引量:1
1
作者 QiuBaoyun HuangJiyan YuanShouqi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2004年第4期498-501,共4页
Characters of head of low head pump station and the pump shaft power areanalyzed. Influence of each single factor on pump shaft power is expressed as change of specificshaft power. (non-dimensional) and the probabilit... Characters of head of low head pump station and the pump shaft power areanalyzed. Influence of each single factor on pump shaft power is expressed as change of specificshaft power. (non-dimensional) and the probability density function is determined. Influences ofmultiple factors on pump shaft power are analyzed. Method of calculating none over-loadedprobability of motor by integration by successive reductions is put forward and then relationbetween power spare coefficient and none over-loaded reliability of electric motor is established.Influences of all factors on pump shaft power being considered completely; power spare coefficientsof motor are calculated in three kinds of heads (changing and unchanging), two kinds of dirty-outconditions. Electrical motor power spare coefficients should be chosen as 1.20 approx 1.44, 1.11approx 1.19, 1.09 approx.14 respectively when pump heads are 4, 7, 9.5 m. The results mean much toreasonable choose of electrical motors in large pump stations, increasing reliability of pump unitsand saving equipment investment. 展开更多
关键词 Large pump station Electrical motor Power spare coefficient Probability ofnone over-loaded