This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accur...This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accurately by connecting separate lubricant oil circuit with test section in parallel. It was built up by retrofitting a multiple air-conditioner and installing three oil-separators in serials at the compressor outlet. And so the lubricant oil in the discharged refrigerant gas of compressor can be removed completely.The refrigerant flow rate through test section can be bypassed by the by-path circuit of indoor unit.This experimental rig has advantages such as on-line and continuous oil injection, short time of obtaining stability, flexible operation, simple control, which lead to high efficiency in the research of flow boiling heat transfer of refrigerant and lubricant oil mixture.展开更多
Heat transfer coefficients of the quench medium are necessary for heat-treatment simulation. Cooling characteristics of quenching oil vary with kinds and usage greatly. Users are selecting oil solutions that come up t...Heat transfer coefficients of the quench medium are necessary for heat-treatment simulation. Cooling characteristics of quenching oil vary with kinds and usage greatly. Users are selecting oil solutions that come up to their desired hardness and quenching distortion requirements. In particular cooling performance rises by agitation and decompression. Therefore we identified a heat transfer coefficient by usage and kinds of quenching oil. Cooling characteristics are different greatly by a kind of quenching oil. A difference of a cooling characteristic by a kind of oil depends on a temperature range of a boiling stage and the maximum heat transfer coefficient mainly. On the other hand, in a convection stage, there are few changes in a boiling stage. Even if quenching oil temperature is changed, heat transfer coefficients do not change greatly. When quenching oil stirred, heat transfer coefficients of vapor blanket stage and a convection stage rise, but there are a few changes in a boiling stage. When quenching oil is decompressed a temperature range of a high heat transfer coefficient moves to the low temperature side. In addition, a heat transfer coefficient in a vapor blanket stage comes down. For precision improvement of heat-treatment simulation, it is important that the heat transfer coefficient is calculated in conformity to the on-site use reality.展开更多
This study describes thermal behavior of magnetic lubricant oil under electromagnetic induction. Experimental set up include oil pump, oil tank, induction heating unit, and heat exchanger. It is a closed loop system w...This study describes thermal behavior of magnetic lubricant oil under electromagnetic induction. Experimental set up include oil pump, oil tank, induction heating unit, and heat exchanger. It is a closed loop system where the oil pump circulates oil through oil tank to the system, at the same time induction heating unit heats up to the heat exchanger where the lubricant oil thermal behavior is examined. The unit has been largely studied and tested both magnetic and regular motor oil in a laboratory environment and promising results have been obtained for an actual indoor floor to space heating system design.展开更多
Based on the energy equation of gas-liquid flow in pipeline,the explicit temperature drop formula for gas-liquid steady state calculation was derived.This formula took into consideration the Joule-Thomson effect,impac...Based on the energy equation of gas-liquid flow in pipeline,the explicit temperature drop formula for gas-liquid steady state calculation was derived.This formula took into consideration the Joule-Thomson effect,impact of terrain undulation and heat transfer with the surroundings along the line.Elimination of temperature iteration loop and integration of the explicit temperature equation,instead of enthalpy energy equation,into the conjugated hydraulic and thermal computation have been found to improve the efficiency of algorithm.Then,the inner wall temperature of gas-liquid flow was calculated by using explicit temperature equation and inner wall convective heat transfer coefficient of mixed flow which can be obtained by liquid convective heat transfer coefficient and gas convective heat transfer coefficient on the basis of liquid holdup.The temperature results of gas-liquid flow and inner wall in the case example presented both agree well with those in professional multiphase computational software OLGA.展开更多
文摘This paper proposed a new experimental rig of testing flow boiling heat transfer of refrigerant and lubricant oil mixture. The quantity of oil in the test section can be controlled and regulated conveniently and accurately by connecting separate lubricant oil circuit with test section in parallel. It was built up by retrofitting a multiple air-conditioner and installing three oil-separators in serials at the compressor outlet. And so the lubricant oil in the discharged refrigerant gas of compressor can be removed completely.The refrigerant flow rate through test section can be bypassed by the by-path circuit of indoor unit.This experimental rig has advantages such as on-line and continuous oil injection, short time of obtaining stability, flexible operation, simple control, which lead to high efficiency in the research of flow boiling heat transfer of refrigerant and lubricant oil mixture.
文摘Heat transfer coefficients of the quench medium are necessary for heat-treatment simulation. Cooling characteristics of quenching oil vary with kinds and usage greatly. Users are selecting oil solutions that come up to their desired hardness and quenching distortion requirements. In particular cooling performance rises by agitation and decompression. Therefore we identified a heat transfer coefficient by usage and kinds of quenching oil. Cooling characteristics are different greatly by a kind of quenching oil. A difference of a cooling characteristic by a kind of oil depends on a temperature range of a boiling stage and the maximum heat transfer coefficient mainly. On the other hand, in a convection stage, there are few changes in a boiling stage. Even if quenching oil temperature is changed, heat transfer coefficients do not change greatly. When quenching oil stirred, heat transfer coefficients of vapor blanket stage and a convection stage rise, but there are a few changes in a boiling stage. When quenching oil is decompressed a temperature range of a high heat transfer coefficient moves to the low temperature side. In addition, a heat transfer coefficient in a vapor blanket stage comes down. For precision improvement of heat-treatment simulation, it is important that the heat transfer coefficient is calculated in conformity to the on-site use reality.
文摘This study describes thermal behavior of magnetic lubricant oil under electromagnetic induction. Experimental set up include oil pump, oil tank, induction heating unit, and heat exchanger. It is a closed loop system where the oil pump circulates oil through oil tank to the system, at the same time induction heating unit heats up to the heat exchanger where the lubricant oil thermal behavior is examined. The unit has been largely studied and tested both magnetic and regular motor oil in a laboratory environment and promising results have been obtained for an actual indoor floor to space heating system design.
基金Project(2011ZX05000-026-004) supported by the National Science & Technology Specific Program of ChinaProject(2010D-5006-0604) supported by the China National Petroleum Corporation (CNPC) Innovation FoundationProject(51004167) supported by the National Natural Science Foundation of China
文摘Based on the energy equation of gas-liquid flow in pipeline,the explicit temperature drop formula for gas-liquid steady state calculation was derived.This formula took into consideration the Joule-Thomson effect,impact of terrain undulation and heat transfer with the surroundings along the line.Elimination of temperature iteration loop and integration of the explicit temperature equation,instead of enthalpy energy equation,into the conjugated hydraulic and thermal computation have been found to improve the efficiency of algorithm.Then,the inner wall temperature of gas-liquid flow was calculated by using explicit temperature equation and inner wall convective heat transfer coefficient of mixed flow which can be obtained by liquid convective heat transfer coefficient and gas convective heat transfer coefficient on the basis of liquid holdup.The temperature results of gas-liquid flow and inner wall in the case example presented both agree well with those in professional multiphase computational software OLGA.