This paper creates 3D solid model and assembly of U RJ 92-6 oil tank and analyses its strength by integrated CAD/CAE/CAM software I-D EAS. Through integrated simulation in computer, design efficiency and quality of oi...This paper creates 3D solid model and assembly of U RJ 92-6 oil tank and analyses its strength by integrated CAD/CAE/CAM software I-D EAS. Through integrated simulation in computer, design efficiency and quality of oil tank is greatly improved. Adopting integrated CAD/CAE/CAM software to carry out integrated research to equ ipment and products, we will be able to take overall analysis in aspects of 3-D solid modeling, pre-assembly and strength, etc., to realize non-paper designi ng and parallel designing. Problems can be found and settled during designing, w hich will increase designing efficiency and one-time success rate and realize o ptimum designing for products.展开更多
This study investigated the use of microbial analysis as a bioremediation option for remediating petroleum sludge, which is part of the waste stream generated in the petroleum industry. The aim is to reduce environmen...This study investigated the use of microbial analysis as a bioremediation option for remediating petroleum sludge, which is part of the waste stream generated in the petroleum industry. The aim is to reduce environmental burden caused by the discharge of untreated sludge. Sludge sample was cultured in other to isolate microorganisms for the sludge treatment. The selected strain of the organisms after screening were Aspergillus flavus, Aspergillus niger, Verticillus sp, Penicillum sp, and Microsporium audouinii. Bioreactors (labeled A, B, C, D and O) were designed for the treatment of petroleum sludge. These reactors contain 2.0 × 10<sup>-2</sup> m<sup>3</sup> of the diluted sludge samples and the isolated organisms for the treatment process. On a weekly basis, the control reactors received 1.5 × 10<sup>-3</sup> m<sup>3</sup> of fresh and saline water respectively. After 12 weeks of treatment, sludge physicochemical characteristics showed distinct variations. From the result, reactor D was the best in terms of remediating the sludge as compared to other reactors. Friedman non-parametric test was performed to check if the weeks of treatment affected the reduction of the total hydrocarbon content (THC) in the five reactors and also checked for significant differences in the THC after treatments. The drop in the THC of the treated sludge ranged from 56.0% to 67.3%. These results showed the possibility of enhanced biodegradation of petroleum sludge by hydrocarbon utilizing microorganisms (fungi).展开更多
This study investigated the effects of gaseous emissions from crude storage tank and gas flaring on air and rainwater quality in Bonny Industrial Island. Ambient air quality parameters, rainwater and weather parameter...This study investigated the effects of gaseous emissions from crude storage tank and gas flaring on air and rainwater quality in Bonny Industrial Island. Ambient air quality parameters, rainwater and weather parameters were collected at 60 m, 80 m, 100 m, 200 m and control plot for 4 weeks at the Bonny. Rainwater parameters were investigated using standard laboratory tests. Data analyses were done using Analysis of variance, pairwise t-test and Pearson’s correlation statistical tools. Results show that emission rates, volatile organic compound (VOC) noise and flare temperature decreased with increasing distance from flare points and crude oil storage tanks. Findings further revealed the emission rates varied significantly with distance away from the gas flaring point (F = 6.196;p = 0.004). The mean concentration of pollutants between gas flare site and crude oil storage tank showed that CO (0.02 ± 0.001 - 0.002 ±0.001), SPM (0.011 ± 0.001 - 0.01 ± 0.001), VOC (0.005 ± 0.001 - 0.01 ± 0.001) and NO<sub>2</sub> (0.04 ± 0.001 - 0.005 ± 0.000) had significant variations (p > 0.05) with CO, O<sub>3</sub> and NO<sub>2</sub> having higher concentrations at the gas flare site while SPM, and VOC were higher around the crude oil storage tank site. Wind turbulence was higher around the gas flaring point (4.93 TKE) than the crude oil storage tank (4.55 TKE). Similarly, there was significant variation in the sun radiation, precipitation, and wind speed caused by gas flaring (1582.25 w/m<sup>2</sup>, 436.25 mm, 0.53 m/s) and crude oil storage tank (1536.25 w/m<sup>2</sup>, 3.91.41 mm, 0.51 m/s). There were also significant variations in flared temperature (F = 22.144;p = 0.001);NO<sub>2</sub> (F = 8.250;p = 0.001), CO (F = 6.000;p = 0.004) and VOC (F = 5.574;p = 0.006) with distance from the gas flaring point. The variation in the rainwater parameters with distance from the gas flaring indicated significant variations in pH (F = 5.594;p = 0.006). The study showed that the concentration of VOC and particulates were high in the supposedly control area which is perceived to be safe for human habitation. Significant variations exist in emission rate (p = 0.015), flare temperature (p = 0.001), NO<sub>2</sub> (p = 0.003), VOC (p = 0.001), noise (p = 0.041), hydrogen carbonate (p = 0.037) and chromium (p = 0.032) between the gas flaring and crude oil storage tank. Regular monitoring is advocated to mitigate the harmful effects of the pollutants.展开更多
-The temperature distributions obtained by different methods of analysis for solving thermal transfer of reinforced concrete (R. C.) submarine oil tanks (RCSOT), including flat wall method, cylinder wall method and fi...-The temperature distributions obtained by different methods of analysis for solving thermal transfer of reinforced concrete (R. C.) submarine oil tanks (RCSOT), including flat wall method, cylinder wall method and finite element method, are compared with the experimental data of thermal transfer of RCSOT. The precision and scope of applicability of different methods are discussed. The principle for selecting analysis method for solving thermal transfer of RCSOT is given. The analytical and experimental temperature distributions show that the wall of RCSOT should consist of double walls and empty space between them should be filled with sand or other heat insulation materials to reduce the temperature difference of the wall and to prevent concrete from cracking.展开更多
To automatically detect oil tanks in polarimetric synthetic aperture radar(SAR) images, a coastal oil tank detection method is proposed based on recognition of T-shaped harbor. First of all, the T-shaped harbor is d...To automatically detect oil tanks in polarimetric synthetic aperture radar(SAR) images, a coastal oil tank detection method is proposed based on recognition of T-shaped harbor. First of all, the T-shaped harbor is detected to locate the region of interest(ROI) of oil tanks. Then all suspicious targets in the ROI are extracted by the segmentation of strong scattering targets and the classifier of H/α. The template targets are selected from the suspicious targets by the combination of a proposed circular degree parameter and the similarity parameter(SP) of the polarimetric coherency matrix. Finally, oil tanks are detected according to the statistics of the similarity parameter between each suspicious target and template targets in ROI. Polarimetric SAR data acquired by RADARSAT-2 over Berkeley and Singapore areas are used for testing. Experiment results show that most of the targets are correctly detected and the overall detection rate is close to 80%.The false rate is effectively reduced by the proposed algorithm compared with the method without T-shaped harbor recognition.展开更多
The method of using multiplexing technique to realize the optically powered multiple detection system is presented. As this system adopted novel time and pulse width multiplexing techniques, reliable separation and er...The method of using multiplexing technique to realize the optically powered multiple detection system is presented. As this system adopted novel time and pulse width multiplexing techniques, reliable separation and error code correcting techniques, it realizes optically powered multiple channel and parameters detection, and successfully applied in the oil tanks for temperature, pressure, liquid level and reserve measurings.展开更多
In order to ensure the safety in using a large cylindrical storage tank,it is necessary to regularly detect its defonnatioii.The traditional total station method has high accuracy in determining the deformation,howeve...In order to ensure the safety in using a large cylindrical storage tank,it is necessary to regularly detect its defonnatioii.The traditional total station method has high accuracy in determining the deformation,however,it has a low measxirement efficiency.Long-term observation means,there are more risks in the petrochemical plant,therefore,this paper proposes the usage of the 3D laser scanner,replacing the traditional total station to determine the defbnnation of a large cylindrical storage tank.The Matlab program,is compiled to calculate the point cloud data,while the tank deformation is analyzed from two different points which are,the local concave convex degree and the ovality degree.It is concluded that,the difference between the data obtained by 3D laser scanning,and total station is within the range of oil tank deformation limit,therefore,3D laser scanner can be used for oil tank deformation detection.展开更多
文摘This paper creates 3D solid model and assembly of U RJ 92-6 oil tank and analyses its strength by integrated CAD/CAE/CAM software I-D EAS. Through integrated simulation in computer, design efficiency and quality of oil tank is greatly improved. Adopting integrated CAD/CAE/CAM software to carry out integrated research to equ ipment and products, we will be able to take overall analysis in aspects of 3-D solid modeling, pre-assembly and strength, etc., to realize non-paper designi ng and parallel designing. Problems can be found and settled during designing, w hich will increase designing efficiency and one-time success rate and realize o ptimum designing for products.
文摘This study investigated the use of microbial analysis as a bioremediation option for remediating petroleum sludge, which is part of the waste stream generated in the petroleum industry. The aim is to reduce environmental burden caused by the discharge of untreated sludge. Sludge sample was cultured in other to isolate microorganisms for the sludge treatment. The selected strain of the organisms after screening were Aspergillus flavus, Aspergillus niger, Verticillus sp, Penicillum sp, and Microsporium audouinii. Bioreactors (labeled A, B, C, D and O) were designed for the treatment of petroleum sludge. These reactors contain 2.0 × 10<sup>-2</sup> m<sup>3</sup> of the diluted sludge samples and the isolated organisms for the treatment process. On a weekly basis, the control reactors received 1.5 × 10<sup>-3</sup> m<sup>3</sup> of fresh and saline water respectively. After 12 weeks of treatment, sludge physicochemical characteristics showed distinct variations. From the result, reactor D was the best in terms of remediating the sludge as compared to other reactors. Friedman non-parametric test was performed to check if the weeks of treatment affected the reduction of the total hydrocarbon content (THC) in the five reactors and also checked for significant differences in the THC after treatments. The drop in the THC of the treated sludge ranged from 56.0% to 67.3%. These results showed the possibility of enhanced biodegradation of petroleum sludge by hydrocarbon utilizing microorganisms (fungi).
文摘This study investigated the effects of gaseous emissions from crude storage tank and gas flaring on air and rainwater quality in Bonny Industrial Island. Ambient air quality parameters, rainwater and weather parameters were collected at 60 m, 80 m, 100 m, 200 m and control plot for 4 weeks at the Bonny. Rainwater parameters were investigated using standard laboratory tests. Data analyses were done using Analysis of variance, pairwise t-test and Pearson’s correlation statistical tools. Results show that emission rates, volatile organic compound (VOC) noise and flare temperature decreased with increasing distance from flare points and crude oil storage tanks. Findings further revealed the emission rates varied significantly with distance away from the gas flaring point (F = 6.196;p = 0.004). The mean concentration of pollutants between gas flare site and crude oil storage tank showed that CO (0.02 ± 0.001 - 0.002 ±0.001), SPM (0.011 ± 0.001 - 0.01 ± 0.001), VOC (0.005 ± 0.001 - 0.01 ± 0.001) and NO<sub>2</sub> (0.04 ± 0.001 - 0.005 ± 0.000) had significant variations (p > 0.05) with CO, O<sub>3</sub> and NO<sub>2</sub> having higher concentrations at the gas flare site while SPM, and VOC were higher around the crude oil storage tank site. Wind turbulence was higher around the gas flaring point (4.93 TKE) than the crude oil storage tank (4.55 TKE). Similarly, there was significant variation in the sun radiation, precipitation, and wind speed caused by gas flaring (1582.25 w/m<sup>2</sup>, 436.25 mm, 0.53 m/s) and crude oil storage tank (1536.25 w/m<sup>2</sup>, 3.91.41 mm, 0.51 m/s). There were also significant variations in flared temperature (F = 22.144;p = 0.001);NO<sub>2</sub> (F = 8.250;p = 0.001), CO (F = 6.000;p = 0.004) and VOC (F = 5.574;p = 0.006) with distance from the gas flaring point. The variation in the rainwater parameters with distance from the gas flaring indicated significant variations in pH (F = 5.594;p = 0.006). The study showed that the concentration of VOC and particulates were high in the supposedly control area which is perceived to be safe for human habitation. Significant variations exist in emission rate (p = 0.015), flare temperature (p = 0.001), NO<sub>2</sub> (p = 0.003), VOC (p = 0.001), noise (p = 0.041), hydrogen carbonate (p = 0.037) and chromium (p = 0.032) between the gas flaring and crude oil storage tank. Regular monitoring is advocated to mitigate the harmful effects of the pollutants.
文摘-The temperature distributions obtained by different methods of analysis for solving thermal transfer of reinforced concrete (R. C.) submarine oil tanks (RCSOT), including flat wall method, cylinder wall method and finite element method, are compared with the experimental data of thermal transfer of RCSOT. The precision and scope of applicability of different methods are discussed. The principle for selecting analysis method for solving thermal transfer of RCSOT is given. The analytical and experimental temperature distributions show that the wall of RCSOT should consist of double walls and empty space between them should be filled with sand or other heat insulation materials to reduce the temperature difference of the wall and to prevent concrete from cracking.
基金supported by the National Key R&D Program of China(2017YFB0502700)the National Natural Science Foundation of China(61490693+3 种基金61771043)the High-Resolution Earth Observation Systems(41-Y20A14-9001-15/1630-Y20A12-9004-15/1630-Y20A10-9001-15/16)
文摘To automatically detect oil tanks in polarimetric synthetic aperture radar(SAR) images, a coastal oil tank detection method is proposed based on recognition of T-shaped harbor. First of all, the T-shaped harbor is detected to locate the region of interest(ROI) of oil tanks. Then all suspicious targets in the ROI are extracted by the segmentation of strong scattering targets and the classifier of H/α. The template targets are selected from the suspicious targets by the combination of a proposed circular degree parameter and the similarity parameter(SP) of the polarimetric coherency matrix. Finally, oil tanks are detected according to the statistics of the similarity parameter between each suspicious target and template targets in ROI. Polarimetric SAR data acquired by RADARSAT-2 over Berkeley and Singapore areas are used for testing. Experiment results show that most of the targets are correctly detected and the overall detection rate is close to 80%.The false rate is effectively reduced by the proposed algorithm compared with the method without T-shaped harbor recognition.
基金This subject is subsidized by Hebei Education Commission
文摘The method of using multiplexing technique to realize the optically powered multiple detection system is presented. As this system adopted novel time and pulse width multiplexing techniques, reliable separation and error code correcting techniques, it realizes optically powered multiple channel and parameters detection, and successfully applied in the oil tanks for temperature, pressure, liquid level and reserve measurings.
基金National Natural Science Foundation of China(project number:41661091)Lanzhou Jiaotong University Excellent Platform Support Project(201806)。
文摘In order to ensure the safety in using a large cylindrical storage tank,it is necessary to regularly detect its defonnatioii.The traditional total station method has high accuracy in determining the deformation,however,it has a low measxirement efficiency.Long-term observation means,there are more risks in the petrochemical plant,therefore,this paper proposes the usage of the 3D laser scanner,replacing the traditional total station to determine the defbnnation of a large cylindrical storage tank.The Matlab program,is compiled to calculate the point cloud data,while the tank deformation is analyzed from two different points which are,the local concave convex degree and the ovality degree.It is concluded that,the difference between the data obtained by 3D laser scanning,and total station is within the range of oil tank deformation limit,therefore,3D laser scanner can be used for oil tank deformation detection.