Comprehensive evaluation of the transformer oil-paper insulation state based on RF-combination weighting and an improved TOPSIS method 被引量:7
1
作者 Fugen Song Shichao Tong 《Global Energy Interconnection》 EI CAS CSCD 2022年第6期654-665,共12页
The accurate identification of the oil-paper insulation state of a transformer is crucial for most maintenance strategies.This paper presents a multi-feature comprehensive evaluation model based on combination weighti... The accurate identification of the oil-paper insulation state of a transformer is crucial for most maintenance strategies.This paper presents a multi-feature comprehensive evaluation model based on combination weighting and an improved technique for order of preference by similarity to ideal solution(TOPSIS)method to perform an objective and scientific evaluation of the transformer oil-paper insulation state.Firstly,multiple aging features are extracted from the recovery voltage polarization spectrum and the extended Debye equivalent circuit owing to the limitations of using a single feature for evaluation.A standard evaluation index system is then established by using the collected time-domain dielectric spectrum data.Secondly,this study implements the per-unit value concept to integrate the dimension of the index matrix and calculates the objective weight by using the random forest algorithm.Furthermore,it combines the weighting model to overcome the drawbacks of the single weighting method by using the indicators and considering the subjective experience of experts and the random forest algorithm.Lastly,the enhanced TOPSIS approach is used to determine the insulation quality of an oil-paper transformer.A verification example demonstrates that the evaluation model developed in this study can efficiently and accurately diagnose the insulation status of transformers.Essentially,this study presents a novel approach for the assessment of transformer oil-paper insulation. 展开更多
关键词 Combined weight method Random forest algorithm insulation aging assessment oil-paper insulation Time-domain eigenvalue
下载PDF
Chaotic Characteristic of Time Series of Partial Discharge in Oil-Paper Insulation
2
作者 罗勇芬 纪海英 +1 位作者 黄平 李彦明 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第6期740-746,共7页
The chaotic characteristics of time series of five partial discharge (PD) patterns in oil-paper insulation are studied. The results verify obvious chaotic characteristic of the time series of discharge signals and t... The chaotic characteristics of time series of five partial discharge (PD) patterns in oil-paper insulation are studied. The results verify obvious chaotic characteristic of the time series of discharge signals and the fact that PD is a chaotic process. These time series have distinctive features, and the chaotic attractors obtained from time series differed greatly from each other by shapes in the phase space, so they could be used to qualitatively identify the PD patterns. The phase space parameters are selected, then the chaotic characteristic quantities can be extracted. These quantities could quantificationally characterize the PD patterns. The effects on pattern recognition of PRPD and CAPD are compared by using the neural network of radial basis function. The results show that both of the two recognition methods work well and have their respective advantages. Then, both the statistical operators under PRPD mode and the chaotic characteristic quantities under CAPD mode are selected comprehensively as the input vectors of neural network, and the PD pattern recognition accuracy is thereby greatly improved. 展开更多
关键词 oil-paper insulation partial discharge time series CHAOS pattern recognition
下载PDF
The Research of Connection between Degree of Polymerization and Frequency Domain Dielectric Spectroscopy Characteristics during Oil-Paper Insulation Aging
3
作者 Danyu Jiang Guangning Wu +1 位作者 Xian Yang Qingkai Hao 《Energy and Power Engineering》 2017年第4期667-674,共8页
In order to study the linkage effects between degree of polymerization and frequency domain dielectric spectroscopy characteristics of oil-paper insulation, the frequency domain dielectric response test platform of oi... In order to study the linkage effects between degree of polymerization and frequency domain dielectric spectroscopy characteristics of oil-paper insulation, the frequency domain dielectric response test platform of oil-paper insulation is set up. Complex permittivity of oil-paper insulation respectively composed by new or aged oil and insulation paper with different DP are tested, and complex permittivity of oil-paper insulation respectively composed by insulation respectively composed by new oil and insulation paper with different DP and low or high moisture content are tested. The test results are analyzed, and the analysis results show that the degree of polymerization of insulation paper has an influence on complex permittivity of oil-paper insulation though influencing the distribution of moisture and acids between oil and paper. 展开更多
关键词 DEGREE of POLYMERIZATION oil-paper insulation Frequency DOMAIN Dielectric Spectroscopy MOISTURE
下载PDF
Low Frequency Dispersion Mechanism of Dielectric Response for Oil-paper Insulation Diagnosis 被引量:14
4
作者 ZHOU Lijun LI Xianlang WU Guangning 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1873-1880,共8页
Both the real part and imaginary part of complex permittivity approximately have a log-linear frequency dependency at low fre- quencies, especially at ultra-low frequencies under conditions of different moisture conce... Both the real part and imaginary part of complex permittivity approximately have a log-linear frequency dependency at low fre- quencies, especially at ultra-low frequencies under conditions of different moisture concentrations and temperatures, which is recognized as the low frequency dispersion (LFD). In order to explain this dispersion, a new mechanism of dielectric response of LFD of oil-paper insula- tion is proposed. A simplified one-dimensional mathematical model of concentration polarization carrier caused by slow migration is developed and solved, which indicates that ion mobility is closely related to the size of gap and the adsorption capacity of cellulose molecu- lar chains to ions. A stochastic statistical model of the carrier mobility induced LFD is also developed. Moreover, actual tests under 50 °C and 2% moisture content were put forward, as well as simulations with according current waveforms. The simulation results agreed well with the experimental data in that concentration polarization of carriers caused by slow migration is the probable cause of low frequency dispersion of dielectric response for oil-paper insulation diagnosis. 展开更多
关键词 分散介质 油纸绝缘 绝缘诊断 低频率 机制 离子迁移率 一维数学模型 载流子迁移率
下载PDF
Statistical Distributions of Partial Discharges in Oil-paper Insulation Under AC-DC Combined Voltages 被引量:5
5
作者 LI Jian JIANG Tianyan +2 位作者 HE Zhiman CHENG Changkui BAO Lianwei 《高电压技术》 EI CAS CSCD 北大核心 2012年第8期1856-1862,共7页
关键词 局部放电 射频信号 放电量 高电压技术
下载PDF
Characteristic Analysis of Partial Discharges and Dissolved Gases Generated Cavityin Oil-paper Insulation Under AC-DC Combined Voltages 被引量:2
6
作者 HE Zhiman LI Jian +2 位作者 BAO Lianwei JIANG Tianyan WANG Youyuan 《高电压技术》 EI CAS CSCD 北大核心 2012年第8期2091-2096,共6页
关键词 局部放电 射频信号 放电量 高电压技术
下载PDF
Improvement on Condition Assessment Model for Oil-paper Insulation 被引量:1
7
作者 LA Yuan SHI Xuetao +4 位作者 CAO Wen HE Baosheng KE Chunjun WU Kai LONG Hongyu 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1974-1980,共7页
Identification of the aging condition and the failure probability of oil-paper insulation in transformer is important for improving the reliability of electric power transmission system and applying life cycle cost (L... Identification of the aging condition and the failure probability of oil-paper insulation in transformer is important for improving the reliability of electric power transmission system and applying life cycle cost (LCC) management to electrical equipment. Based on data obtained in a series of multi-accelerated-aging experiments, two approaches for calculating failure probability of oil-paper insulation were compared in aspects of degree of polymerization (DP) and condition ranking. In the experiments, mineral oil and cellulose paper are sub- jected to electrical and thermal stresses, and several parameters, including dissolved gases’ volume fraction, furfural content, moisture content, and degree of polymerization, are measured after the aging process. Results show that weight of carbon oxide, which has a close relationship with cellulose paper degradation, is much higher in DP model than in condition ranking model. Moreover, it is concluded that DP model is more practically accurate than condition ranking model, because aging of cellulose paper rather than mineral oil is the key and critical factor of oil-paper insulation aging. 展开更多
关键词 油纸绝缘 评估模型 绝缘状态 老化实验 寿命周期成本 电力传输系统 失效概率 纤维素
下载PDF
Space Charge Characteristics of Oil-paper Insulation with New Paper and Aged Oil 被引量:1
8
作者 MU Haibao WANG Da +4 位作者 WANG Shiqiang TIAN Jie LI Yuan WEI Yanhui ZHANG Guanjun 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1865-1872,共8页
Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stress... Oil-paper compound insulation has been widely used in power transformers for quite a long time because of its good performances. The insulation gradually degrades under combined thermal, electrical and chemical stresses during routine operations, mainly because of space charges inside. This work investigated the space charge characteristics in oil-paper insulation under oil aging circumstance. New trans- former oil samples are thermally aged to obtain different aging states, and their physical and chemical properties are analyzed. New Kraft papers are dried in vacuum and fully immersed in these different aged oil samples, and three kinds of oil-paper samples are obtained. We use the pulsed electro-acoustic (PEA) method to measure space charge under both DC voltage-on and voltage-off conditions at room temperature. The effect of oil aging state on characteristics of space charge injection, accumulation, and decay is analyzed and discussed. The results show that comparing with the DC voltage-off condition, more charges are injected into samples at the interface of electrode and dielectric when DC voltage is on. When the oil-aged state gets worse, more charges are induced at both cathode and anode, more space charges are accumulated in the bulk, the area of negative charges is larger, and local electric field is distorted more seriously. Moreover, for the voltage-off condition, aged oil is good for space charge decay, and trapped positive space charges decay faster than trapped negative charges. 展开更多
关键词 空间电荷 油纸绝缘 电荷特性 老年 老化状态 直流电压 衰减特性 电荷积累
下载PDF
A New Method for the Aging Evaluation of Oil-Paper Insulation Using η-Butanol and Methanol
9
作者 Jianyi Wang Yuanxiang Zhou +3 位作者 Jun Liu Zhaowei Wang Song Bai Jiayu Lu 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期717-726,共10页
To improve the accuracy and efficiency of the aging life prediction and assessment of transformer oil-paper insulation,and to make up for the deficiencies of traditional characterizers,such as 2-furfural,carbon monoxi... To improve the accuracy and efficiency of the aging life prediction and assessment of transformer oil-paper insulation,and to make up for the deficiencies of traditional characterizers,such as 2-furfural,carbon monoxide,and carbon dioxide,a method for the simultaneous determination of methanol,ethanol,n−propanol,and η-butanol in oil with a single injection is established by headspace-gas chromatography-mass spectrometry.The measured results show that the determination limits of the four alcohol characterizers can be controlled to 10μg/kg level.Based on this method,the change patterns of the above four alcohols with thermal aging time and degree of polymerization are obtained through thermal aging experimental research.Ethanol,η-propanol,and η-butanol in oil indicate nearly linear correlations with thermal aging time and degree of polymerization,similar to that of methanol.By analyzing 52 sets of measured data of 500 kV EHV transformers in operation,η-butanol is found to have excellent performance,and a new method to evaluate the aging state of oil-paper insulation employing η-butanol and methanol is proposed along with the aging attention value model.The measured data of 500 kV EHV transformers in operation indicate that the combination of η-butanol and methanol as the preferred characterizers can effectively compensate for the shortcoming of traditional characterizers in the early stages of aging,and the feasibility of the method is verified.Two possible pathways for the generation of η-butanol by cellulose cleavage during the aging of oil-paper are proposed from the chemical structure of cellulose. 展开更多
关键词 Aging characterization determination method METHANOL η-butanol oil-paper insulation 500 kV transformers
原文传递
Model moisture transport in oil-paper insulation of transformer:Theory and experiment
10
作者 Junjie Zhou Zhicheng Wu +3 位作者 Yiran Guo Rui Zhang Wenbing Zhu Qiaogen Zhang 《High Voltage》 SCIE EI CSCD 2024年第4期879-887,共9页
The insulation performance of oil paper insulation is significantly affected by moisture such that monitoring moisture content is important.However,it is difficult to obtain the moisture content accurately due to its ... The insulation performance of oil paper insulation is significantly affected by moisture such that monitoring moisture content is important.However,it is difficult to obtain the moisture content accurately due to its dynamic change under multi physical fields.Studying the moisture transportation in oil paper insulation under multi physical fields becomes a vital method in solving the problem.A multi physical model describing moisture migration was proposed,which considered the effects of temperature on moisture in different existing states in oil-immersed paper(OIP).The temperature distribution formed a vapour pressure gradient to drive moisture migration and affected migration speed.Then,experiments and simulations of moisture migration were performed,which showed that the experiments were in good agreement with simulation.The results revealed that the temperature gradient caused uneven moisture distribution and the increased temperature reduced OIP moisture content.The established model could fully characterise moisture migration under temperature gradient,which provided a theoretical reference for predicting the risk of partial dampness and evaluating insulation performance. 展开更多
关键词 MOISTURE insulation distribution
原文传递
Microscopic mechanisms analysis of various dielectric response processes in oil-paper insulation with different insulating states
11
作者 Zaijun Jiang Jiefeng Liu +4 位作者 Xianhao Fan Heng Zhang Enze Zhang Boshu Song Yiyi Zhang 《High Voltage》 SCIE EI CSCD 2024年第3期591-600,共10页
Various dielectric response processes in the oil-paper insulation are sensitively affected by the insulating states(ageing degrees and moisture contents).However,the existing research is still incomplete in revealing ... Various dielectric response processes in the oil-paper insulation are sensitively affected by the insulating states(ageing degrees and moisture contents).However,the existing research is still incomplete in revealing the microscopic mechanisms of various dielectric response processes in oil-paper insulation with different insulating states.Given this issue,the genetic algorithm is first adopted to extract the Dissado–Hill(D–H)model parameters by simulating the frequency domain spectroscopy(FDS)of oil-paper insu-lation.Then,the change laws of the extracted D–H model parameters are adopted to reveal the microscopic mechanisms of various dielectric response processes.Microscopic mechanisms of four dielectric response processes are studied,which are quasi-dc relax-ation,loss peak relaxation,optical frequency relaxation,and DC conductance.Meanwhile,due to the dielectric response processes being dominated by various polar particles(methanol,ethanol,furfural,and water molecule),the contents of various ageing by-products dissolved in the insulating oil are measured to support the above analysis.In this respect,a dielectric theoretical reference for the FDS technique to research the insulating states of oil-paper insulation is provided. 展开更多
关键词 MECHANISMS insulation RELAXATION
原文传递
Dynamics of an impurity ion transport in oil-paper insulation under various electric fields
12
作者 Yuanyang Ren Yang Wang +4 位作者 Qiankai Zhang Jiayu Xiong Wen Cao Zepeng Lv Kai Wu 《High Voltage》 SCIE EI CSCD 2024年第1期66-80,共15页
The ionic transport process is an important counterpart to charge transport in oil-paper insulation,and it significantly impacts oil flow electrification at the oil-paper interface.Despite this,the dynamics of this ph... The ionic transport process is an important counterpart to charge transport in oil-paper insulation,and it significantly impacts oil flow electrification at the oil-paper interface.Despite this,the dynamics of this phenomenon and the underlying mechanisms remain unclear,particularly at the molecular level.To understand this fundamental aspect,we conduct Molecular Dynamics study on the transport behaviour of an impurity ion in different oil-paper insulation models under various external electric fields.Different influence factors,such as external electric fields,temperatures,and local structural characteristics,are investigated in relation to the corresponding ionic mobility in different polymer models.According to the simulations,ionic mobility and its response to electric fields are higher in weaker electrostatic models.As a result,mineral oil exhibits the highest ionic mobility and the most substantial enhancement of ionic mobility by external electric fields,followed by vegetable oil,oil-paper blends,and insulating paper.This significant deviation in ionic mobility between oil and paper leads to the formation of an electric double layer near the oil-paper interface.The underlying physical mechanisms of different ionic mobility and its response to the electric field in different polymer models could be explained by the different polymer structural influences in terms of interaction energy and coordination numbers in a static manner,as well as by the interactions between the impurity ion and its surrounding atoms in terms of lifetime correlation functions and velocity autocorrelation functions in a dynamic manner.In addition,the influence of temperature on ionic mobility in mineral and vegetable oil is examined,and their activation energies are calculated.Advancing in the fundamental understanding of the dynamics of the ion transport process in oil-paper insulation is vital to improving their insulating properties for oil-impregnated power transformers. 展开更多
关键词 insulation TRANSPORT FIELDS
原文传递
Research on the variation of dielectric properties of oil-paper insulation for power equipment over a wide temperature range
13
作者 Mingze Zhang Muhe Yu +4 位作者 Wen Zhou Yilin Liang Shengjie Lei Yunbo Shi Limin Qu 《High Voltage》 SCIE EI CSCD 2024年第3期648-658,共11页
The main part of oil-immersed power equipment is oil-paper insulation.At lower ambient temperatures,transformer oil will become viscous.As a result,compared to those at room temperature or operating temperature,the fr... The main part of oil-immersed power equipment is oil-paper insulation.At lower ambient temperatures,transformer oil will become viscous.As a result,compared to those at room temperature or operating temperature,the frequency domain dielectric properties of oil-paper insulation at low temperatures are drastically different.For evaluating the insulation condition of electrical equipment,it is essential to accurately determine their dielectric properties.This paper described the FDS test,the DC conductivity test,and the transformer oil viscosity test,which was carried out in a laboratory environment for different ageing of oil-immersed pressboard and transformer oil at 233–373 K.The ef-fects of temperature on the dielectric properties at the competing mechanisms of polarisation and conductivity loss were clarified based on variations of the FDS curves.Considering the viscosity change of ageing transformer oil at low temperatures,the Arrhenius and VFT viscosity equations were used to achieve a fitting calculation in the different temperature zones.Based on the molecular/ion transition model in the force field and electric field,the characterisation relationships between the dynamic viscosity,DC conductivity,and test temperature of transformer oil were established.The limita-tions of conventional transformer oil equivalent dielectric relaxation models over a wide temperature range were finally clarified by combining the test findings of the DC con-ductivity over a wide temperature range with observed and simulated calculations.This paper provides an essential theoretical reference when using the FDS test to diagnose the insulation performance of oil-immersed power equipment in extremely cold regions. 展开更多
关键词 insulation VISCOSITY immersed
原文传递
Research on the feature extraction of DC space charge behavior of oil-paper insulation 被引量:13
14
作者 TANG Chao LIAO RuiJin +1 位作者 CHEN George YANG LiJun 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第5期1315-1324,共10页
As the ultra high DC voltage grid comes into an important stage in the ‘Twelfth Five-year Plan’ of China, the requirement on the operation safety of power equipment needs to be improved. Oil-paper insulation plays a... As the ultra high DC voltage grid comes into an important stage in the ‘Twelfth Five-year Plan’ of China, the requirement on the operation safety of power equipment needs to be improved. Oil-paper insulation plays a significant role as the main insulation material of many key power equipments. The space charge behaviors of oil-paper insulation not only affect the dielectric strength, but also relate to the stability and security of power transmission facilities. Until now, the research on the space charge behaviors of oil-paper insulation remains on the stage of objective description and phenomenon explanation, thus it is very urgent to make some feature extractions on the test results in order to further investigate the DC space charge behaviors of oil-paper insulation. In this paper, based on the large numbers of test data in the first stage, data mining and feature extractions were performed on the DC space charge behavior of oil-paper insulation. The variation laws of some key characteristic parameters obtained in different experiment conditions such as the total charge injection amount, apparent charge mobility, and trap energy distribution were analyzed. In addition, the distribution of trapping level inside oil-paper was calculated by using the PEA test results based on the mechanism of the isothermal decay current, which realized the approximate calculation of trap depth by charge decay characteristics. What’s more, the exponential injection and decay equations of DC space charge changing with time were acquired for the first time, and the physical meanings of related parameters were defined. This has laid a foundation for the prediction and simulation of space charge in the oil-paper insulation. 展开更多
关键词 oil-paper insulation space charge DC feature extraction
原文传递
Space Charge Characteristics of Oil-paper Insulation in the Electro-thermal Aging Process 被引量:6
15
作者 Yuanxiang Zhou Chao Dai Meng Huang 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第2期40-46,共7页
High electric field and temperatures can result in electrical property degradation of oil-paper insulation and accelerate its aging process.This paper describes the regulation of space charge in the process of electro... High electric field and temperatures can result in electrical property degradation of oil-paper insulation and accelerate its aging process.This paper describes the regulation of space charge in the process of electro-thermal aging.Electric field distortion and differences in characteristic parameters during electro-thermal aging are analyzed,along with the effects of electro-thermal aging on space charge from the perspective of trap energy.High temperature and an electric field are used to accelerate the aging of oil-paper,and space charge characteristics are measured using the pulsed electro-acoustic(PEA)method throughout the electro-thermal aging.Based on results obtained,it can be concluded that homo-charge injection occurs at the anode and the type of the charge injection at the cathode varies throughout the electro-thermal aging;the decrease of permittivity during aging allows for space charge injection to take place;growth of trap depth makes the space charge accumulate in the middle of the sample;and space charge accumulation after electro-thermal aging results in inner electric field distortion,which leads to large current and decreased breakdown in voltages. 展开更多
关键词 Electric field distortion electro-thermal aging homogeneous charge oil-paper insulation pulsed electro-acoustic(PEA)method space charge
原文传递
Flexible and Robust Functionalized Boron Nitride/Poly(p‑Phenylene Benzobisoxazole)Nanocomposite Paper with High Thermal Conductivity and Outstanding Electrical Insulation 被引量:1
16
作者 Lin Tang Kunpeng Ruan +3 位作者 Xi Liu Yusheng Tang Yali Zhang Junwei Gu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第2期423-437,共15页
With the rapid development of 5G information technology,thermal conductivity/dissipation problems of highly integrated electronic devices and electrical equipment are becoming prominent.In this work,“high-temperature... With the rapid development of 5G information technology,thermal conductivity/dissipation problems of highly integrated electronic devices and electrical equipment are becoming prominent.In this work,“high-temperature solid-phase&diazonium salt decomposition”method is carried out to prepare benzidine-functionalized boron nitride(m-BN).Subsequently,m-BN/poly(pphenylene benzobisoxazole)nanofiber(PNF)nanocomposite paper with nacremimetic layered structures is prepared via sol–gel film transformation approach.The obtained m-BN/PNF nanocomposite paper with 50 wt%m-BN presents excellent thermal conductivity,incredible electrical insulation,outstanding mechanical properties and thermal stability,due to the construction of extensive hydrogen bonds andπ–πinteractions between m-BN and PNF,and stable nacre-mimetic layered structures.Itsλ∥andλ_(⊥)are 9.68 and 0.84 W m^(-1)K^(-1),and the volume resistivity and breakdown strength are as high as 2.3×10^(15)Ωcm and 324.2 kV mm^(-1),respectively.Besides,it also presents extremely high tensile strength of 193.6 MPa and thermal decomposition temperature of 640°C,showing a broad application prospect in high-end thermal management fields such as electronic devices and electrical equipment. 展开更多
关键词 Poly(p-phenylene-2 6-benzobisoxazole)nanofiber Boron nitride Thermal conductivity Electrical insulation
下载PDF
Nano-silica modified lightweight and high-toughness carbon fiber/phenolic ablator with excellent thermal insulation and ablation performance
17
作者 Wenjie Xu Wenda Song +4 位作者 Xianfeng Jia Cheng Ma Jitong Wang Wenming Qiao Licheng Ling 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第1期192-199,共8页
Lightweight and high-toughness carbon fiber/phenolic ablator(CFPA)is required as the Thermal Protection System(TPS)material of aerospace vehicles for next-generation space missions.To improve the ablative properties,s... Lightweight and high-toughness carbon fiber/phenolic ablator(CFPA)is required as the Thermal Protection System(TPS)material of aerospace vehicles for next-generation space missions.To improve the ablative properties,silica sol with good particle size distribution prepared using tetramethoxysilane(TMOS)was blended with natural rubber latex and deposited onto carbon fiber felt,which was then integrated with phenolic aerogel matrix,introducing nano-silica into the framework of CFPA.The modified CFPA with a low density of 0.28—0.31 g/cm3exhibits strain-in-fracture as high as 31.2%and thermal conductivity as low as 0.054 W/(m·K).Furthermore,a trace amount of nano-silica could effectively protect CFPA from erosion of oxidizing atmosphere in different high-temperature environments.The oxyacetylene ablation test of 3000°C for 20 s shows a mass ablation rate of 0.0225 g/s,a linear ablation rate of 0.209 mm/s for the modified CFPA,which are 9.64%and 24.82%lower than the unmodified one.Besides,the long-time butane ablation test of 1200°C for 200 s shows an insignificant recession with mass and linear ablation rate of 0.079 g/s and 0.039 mm/s,16.84%and 13.33%lower than the unmodified one.Meanwhile,the fixed thermocouple in the test also demonstrates a good thermal insulation performance with a low peak back-face temperature of 207.7°C,12.25%lower than the unmodified one.Therefore,the nano-silica modified CFPA with excellent overall performance presents promising prospects in high-temperature aerospace applications. 展开更多
关键词 NANO-SILICA Carbonfiber Phenolic aerogel insulation Ablation
下载PDF
Optimization for sound insulation of a sandwich plate with a corrugation and auxetic honeycomb hybrid core
18
作者 Fenglian LI Yiping WANG Yuxing ZOU 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第9期1595-1612,共18页
A sandwich plate with a corrugation and auxetic honeycomb hybrid core is constructed,and its sound insulation and optimization are investigated.First,the motion governing equation of the sandwich plate is established ... A sandwich plate with a corrugation and auxetic honeycomb hybrid core is constructed,and its sound insulation and optimization are investigated.First,the motion governing equation of the sandwich plate is established by the third-order shear deformation theory(TSDT),and then combined with the fluid-structure coupling conditions,and the sound insulation is solved.The theoretical results are validated by COMSOL simulation results,and the effects of the structural parameter on the sound insulation are analyzed.Finally,the standard genetic algorithm is adopted to optimize the sound insulation of the sandwich plate. 展开更多
关键词 OPTIMIZATION sound insulation hybrid core layer genetic algorithm
下载PDF
A Situational Awareness Method for Initial Insulation Fault of Distribution Network Based on Multi-Feature Index Comprehensive Evaluation
19
作者 Hao Bai Beiyuan Liu +3 位作者 Hongwen Liu Jupeng Zeng Jian Ouyang Yipeng Liu 《Energy Engineering》 EI 2024年第8期2191-2211,共21页
Most ground faults in distribution network are caused by insulation deterioration of power equipment.It is difficult to find the insulation deterioration of the distribution network in time,and the development trend o... Most ground faults in distribution network are caused by insulation deterioration of power equipment.It is difficult to find the insulation deterioration of the distribution network in time,and the development trend of the initial insulation fault is unknown,which brings difficulties to the distribution inspection.In order to solve the above problems,a situational awareness method of the initial insulation fault of the distribution network based on a multi-feature index comprehensive evaluation is proposed.Firstly,the insulation situation evaluation index is selected by analyzing the insulation fault mechanism of the distribution network,and the relational database of the distribution network is designed based on the data and numerical characteristics of the existing distribution management system.Secondly,considering all kinds of fault factors of the distribution network and the influence of the power supply region,the evaluation method of the initial insulation fault situation of the distribution network is proposed,and the development situation of the distribution network insulation fault is classified according to the evaluation method.Then,principal component analysis was used to reduce the dimension of the training samples and test samples of the distribution network data,and the support vector machine(SVM)was trained.The optimal parameter combination of the SVM model was found by the grid search method,and a multi-class SVM model based on 1-v-1 method was constructed.Finally,the trained multi-class SVM was used to predict 6 kinds of situation level prediction samples.The results of simulation examples show that the average prediction accuracy of 6 situation levels is above 95%,and the perception accuracy of 4 situation levels is above 96%.In addition,the insulation maintenance decision scheme under different situation levels is able to be given when no fault occurs or the insulation fault is in the early stage,which can meet the needs of power distribution and inspection for accurately sensing the insulation fault situation.The correctness and effectiveness of this method are verified. 展开更多
关键词 Distribution grid insulation degradation initial insulation fault multi-feature indices multi-class SVM situational level situational awareness
下载PDF
High-sensitive state perception method for inverter-fed machine turn insulation based on FrFT-Mel
20
作者 Ruitian Fan Xing Lei +3 位作者 Tao Jia Menglong Qin Hao Li Dawei Xiang 《Global Energy Interconnection》 EI CSCD 2024年第2期155-165,共11页
Amidst the swift advancement of new power systems and electric vehicles,inverter-fed machines have progressively materialized as a pivotal apparatus for efficient energy conversion.Stator winding turn insulation failu... Amidst the swift advancement of new power systems and electric vehicles,inverter-fed machines have progressively materialized as a pivotal apparatus for efficient energy conversion.Stator winding turn insulation failure is the root cause of inverter-fed machine breakdown.The online monitoring of turn insulation health can detect potential safety risks promptly,but faces the challenge of weak characteristics of turn insulation degradation.This study proposes an innovative method to evaluate the turn insulation state of inverter-fed machines by utilizing the fractional Fourier transform with a Mel filter(FrFT-Mel).First,the sensitivity of the high-frequency(HF)switching oscillation current to variations in turn insulation was analyzed within the fractional domain.Subsequently,an improved Mel filter is introduced,and its structure and parameters are specifically designed based on the features intrinsic to the common-mode impedance resonance point of the electrical machine.Finally,an evaluation index was proposed for the turn insulation state of inverter-fed machines.Experimental results on a 3kW permanent magnet synchronous machine(PMSM)demonstrate that the proposed FrFT-Mel method significantly enhances the sensitivity of turn insulation state perception by approximately five times,compared to the traditional Fourier transform method. 展开更多
关键词 State perception Turn insulation Switching oscillation Fractional Fourier transform Mel filter
下载PDF
上一页 1 2 250 下一页 到第