期刊文献+
共找到33,480篇文章
< 1 2 250 >
每页显示 20 50 100
A Pragmatic Approach to Coping with Matrix Effects during ICP-MS Analysis of Trace Elements in Silicate Rocks and Calibration of REE Interferences
1
作者 C. Michael B. Henderson Paul R. Lythgoe Karen J. Theis 《Journal of Geoscience and Environment Protection》 2019年第3期82-125,共44页
Operating an Agilent 7700X ICP-MS spectrometer under robust plasma conditions (1550 W) with a He-filled octopole collision cell and analysing solutions (?1 total dissolved solids) still suffered analyte peak suppressi... Operating an Agilent 7700X ICP-MS spectrometer under robust plasma conditions (1550 W) with a He-filled octopole collision cell and analysing solutions (?1 total dissolved solids) still suffered analyte peak suppression due to matrix effects. International reference rocks BCR-1, BHVO-1, AGV-1, G-2 and BCR-2 all showed count rate reductions for 36 elements (mass range 7Li to 238U) averaging ~10% but with no dependence on isotope mass. Use of an internal standard (103Rh) and/or using a ten-fold dilution of sample solutions reduced these effects but problems with reduced count rates combined with larger errors for some elements introduced other problems. The best approach was to normalise the count rates for each element in the other samples against those for BCR-1 as an external standard;thus the count suppression due to the matrix effect is corrected for each individual element. This approach provides standardization “traceability” in line with the ERM ISO/IEC requirement. Experiments are also reported on quantifying the proportions of Ba and selected REE oxide/hydroxide components versus parent isotopes (XO/X and XOH/X). This information is essential for correcting peak interferences on higher mass number REE for the rock samples, and equations are developed to use measured CeO/Ce and CeOH/Ce ratios to predict such values for any other member of the REE suite. Concentrations obtained show excellent agreement with recommended values for the international reference materials especially for the REE. Robust data are also provided for two other standard rocks: nepheline syenite STM-1 and quartz syenite CAAS-1;the latter shows exceptional enrichments of Zr, REE, Th, and U. 展开更多
关键词 ICP-MS Dilution Minimises Matrix Effects BCR-1 as an External Standard New Analyses for STM-1 and CAAS-1 calibration of X-O/OH INTERFERENCES on REE Elements
下载PDF
Model calibration concerning risk coefficients of driving safety field model 被引量:5
2
作者 LI Yang WANG Jian-qiang WU Jian 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第6期1494-1502,共9页
Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model ba... Driving safety field(DSF) model has been proposed to represent comprehensive driving risk formed by interactions of driver-vehicle-road in mixed traffic environment. In this work, we establish an optimization model based on grey relation degree analysis to calibrate risk coefficients of DSF model. To solve the optimum solution, a genetic algorithm is employed. Finally, the DSF model is verified through a real-world driving experiment. Results show that the DSF model is consistent with driver's hazard perception and more sensitive than TTC. Moreover, the proposed DSF model offers a novel way for criticality assessment and decision-making of advanced driver assistance systems and intelligent connected vehicles. 展开更多
关键词 intelligent CONNECTED vehicles advanced DRIVER ASSISTANCE systems (ADAS) driving risk assessment driving safety field (DSF) model parameter calibration GREY RELATION degree
下载PDF
Calibration of CO and CO2 Monitors Used in Periodic Inspection of Vehicles at Fixed Stations for Environmental Control
3
作者 Adel Bassuoni Shehata Abdulrahman Rashed Al Askar +2 位作者 Najjy Hamad Al Yami Abdullah Suleiman Al Owaysi Sultan K. Alharbi 《Green and Sustainable Chemistry》 2024年第2期29-41,共13页
Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri... Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment. 展开更多
关键词 MONITORS Periodic Inspection CO/CO<sub>2</sub> calibration LINEARITY Precision Accuracy
下载PDF
Long Term Soil and Water Assessment Tool (SWAT) Calibration from an Ecohydrology Perspective
4
作者 Sivarajah Mylevaganam Raghavan Srinivasan Vijay P. Singh 《Open Journal of Applied Sciences》 2015年第7期344-354,共11页
The performance on prediction by mathematical models which represent the conceived image of a system such as hydrology is oftentimes represented through calibration and verification processes. Oftentimes a best fit be... The performance on prediction by mathematical models which represent the conceived image of a system such as hydrology is oftentimes represented through calibration and verification processes. Oftentimes a best fit between observed and predicted flows is obtained through correlation coefficient (R2) and the Nash Sutcliffe model efficiency (NSE) by minimizing the average Root Mean Square Error (RMSE) of the observed versus simulated flows. However, these days, a new paradigm is emerging wherein accounting for the flow variability for the protection of freshwater biodiversity and maintenance of goods and services that rivers provide is paramount. Therefore, from an ecohydrology perspective, it is not clear if the existing method of model calibration meets the needs of the riverine ecosystem at its best. Thus, this study investigates and proposes a methodology using entropy theory to gage the calibration of Soil and Water Assessment Tool (SWAT) from an ecohydrology perspective characterized by the natural flow-regime paradigm: Indicators of Hydrologic Alteration. 展开更多
关键词 Principle of MAXIMUM ENTROPY ECOHYDROLOGY Indicators of Hydrologic Alteration MAXIMUM ENTROPY Ordered Weighted Averaging SOIL and WATER Assessment Tool calibration
下载PDF
Parameter calibration of the tensile-shear interactive damage constitutive model for sandstone failure
5
作者 Yun Shu Zheming Zhu +4 位作者 Meng Wang Weiting Gao Fei Wang Duanying Wan Yuntao Wang 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第4期1153-1174,共22页
The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The bas... The tensile-shear interactive damage(TSID)model is a novel and powerful constitutive model for rock-like materials.This study proposes a methodology to calibrate the TSID model parameters to simulate sandstone.The basic parameters of sandstone are determined through a series of static and dynamic tests,including uniaxial compression,Brazilian disc,triaxial compression under varying confining pressures,hydrostatic compression,and dynamic compression and tensile tests with a split Hopkinson pressure bar.Based on the sandstone test results from this study and previous research,a step-by-step procedure for parameter calibration is outlined,which accounts for the categories of the strength surface,equation of state(EOS),strain rate effect,and damage.The calibrated parameters are verified through numerical tests that correspond to the experimental loading conditions.Consistency between numerical results and experimental data indicates the precision and reliability of the calibrated parameters.The methodology presented in this study is scientifically sound,straightforward,and essential for improving the TSID model.Furthermore,it has the potential to contribute to other rock constitutive models,particularly new user-defined models. 展开更多
关键词 Damage constitutive model Parameter calibration Rock modeling SANDSTONE Dynamic impact load Tensile-shear interactive damage(TSID)model
下载PDF
Unfolding analysis of LaBr3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration 被引量:12
6
作者 Rui Shi Xian-Guo Tuo +4 位作者 Huai-Liang Li Yang-Yang Xu Fan-Rong Shi Jian-Bo Yang Yong Luo 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第1期23-31,共9页
With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study... With respect to the gamma spectrum, the energy resolution improves with increase in energy. The counts of full energy peak change with energy, and this approximately complies with the Gaussian distribution. This study mainly examines a method to deconvolve the LaBr_3:Ce gamma spectrum with a detector response matrix constructing algorithm based on energy resolution calibration.In the algorithm, the full width at half maximum(FWHM)of full energy peak was calculated by the cubic spline interpolation algorithm and calibrated by a square root of a quadratic function that changes with the energy. Additionally, the detector response matrix was constructed to deconvolve the gamma spectrum. Furthermore, an improved SNIP algorithm was proposed to eliminate the background. In the experiment, several independent peaks of ^(152)Eu,^(137)Cs, and ^(60)Co sources were detected by a LaBr_3:Ce scintillator that were selected to calibrate the energy resolution. The Boosted Gold algorithm was applied to deconvolve the gamma spectrum. The results showed that the peak position difference between the experiment and the deconvolution was within ± 2 channels and the relative error of peak area was approximately within 0.96–6.74%. Finally, a ^(133) Ba spectrum was deconvolved to verify the efficiency and accuracy of the algorithm in unfolding the overlapped peaks. 展开更多
关键词 Detector response MATRIX Energy resolution calibration LaBr3:Ce scintillator SNIP background elimination Boosted Gold DECONVOLUTION ALGORITHM
下载PDF
Hierarchy structure characteristics analysis for the China Loess watersheds based on gully node calibration 被引量:4
7
作者 Hai-ying ZHAO Yi-peng +1 位作者 XU Yue-xue LIU Hai-ying 《Journal of Mountain Science》 SCIE CSCD 2018年第12期2637-2650,共14页
A land surface region can be decomposed into a series of watershed units with a hierarchical organizational structure. For loess landform, the watershed is a basic spatial–structural unit that can express natural lan... A land surface region can be decomposed into a series of watershed units with a hierarchical organizational structure. For loess landform, the watershed is a basic spatial–structural unit that can express natural landforms, surface morphology characteristics, spatial organization and developmental evolution. In this research we adopted the concept of node calibration in the watershed structure unit, selected six complete watersheds on China Loess Plateau as the research areas to study the quantitative characteristics of the hierarchical structure in terms of watershed geomorphology based on digital elevation model(DEM) data, and then built a watershed hierarchical structure model that relies on gully structure feature points. We calculated the quantitative indices, such as elevation, flow accumulation and hypsometric integral and found there are remarkably closer linear correlation between flow accumulation and elevation with increasing gully order, and the same variation tendency of hypsometric integral also presented. The results showed that the characteristics of spatial structure become more stable, and the intensity of spatial aggregation gradually enhances with increasing gully order. In summary, from the view of gully node calibration, the China Loess watershed structure shows more significantly complex, and the developmental situation variation of the loess landforms also exhibited a fairly stable status with gully order increasing. So, the loess watershed structure and its changes constructed the complex system of the loess landform, and it has the great significance for studying the spatial pattern and evolution law of the watershed geomorphology. 展开更多
关键词 Digital ELEVATION models Flow accumulation GULLY structure feature point Hypsometric integral LOESS LANDFORM NODE calibration
下载PDF
Non-crossing Quantile Regression Neural Network as a Calibration Tool for Ensemble Weather Forecasts 被引量:1
8
作者 Mengmeng SONG Dazhi YANG +7 位作者 Sebastian LERCH Xiang'ao XIA Gokhan Mert YAGLI Jamie M.BRIGHT Yanbo SHEN Bai LIU Xingli LIU Martin Janos MAYER 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第7期1417-1437,共21页
Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantil... Despite the maturity of ensemble numerical weather prediction(NWP),the resulting forecasts are still,more often than not,under-dispersed.As such,forecast calibration tools have become popular.Among those tools,quantile regression(QR)is highly competitive in terms of both flexibility and predictive performance.Nevertheless,a long-standing problem of QR is quantile crossing,which greatly limits the interpretability of QR-calibrated forecasts.On this point,this study proposes a non-crossing quantile regression neural network(NCQRNN),for calibrating ensemble NWP forecasts into a set of reliable quantile forecasts without crossing.The overarching design principle of NCQRNN is to add on top of the conventional QRNN structure another hidden layer,which imposes a non-decreasing mapping between the combined output from nodes of the last hidden layer to the nodes of the output layer,through a triangular weight matrix with positive entries.The empirical part of the work considers a solar irradiance case study,in which four years of ensemble irradiance forecasts at seven locations,issued by the European Centre for Medium-Range Weather Forecasts,are calibrated via NCQRNN,as well as via an eclectic mix of benchmarking models,ranging from the naïve climatology to the state-of-the-art deep-learning and other non-crossing models.Formal and stringent forecast verification suggests that the forecasts post-processed via NCQRNN attain the maximum sharpness subject to calibration,amongst all competitors.Furthermore,the proposed conception to resolve quantile crossing is remarkably simple yet general,and thus has broad applicability as it can be integrated with many shallow-and deep-learning-based neural networks. 展开更多
关键词 ensemble weather forecasting forecast calibration non-crossing quantile regression neural network CORP reliability diagram POST-PROCESSING
下载PDF
A new calibration method for radon detector in seismic systems
9
作者 Hongwei Ren Yaowei Liu 《Earthquake Science》 2024年第5期445-458,共14页
Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector ... Radon observation is an important measurement item of seismic precursor network observation.The radon detector calibration is a key technical link for ensuring radon observation accuracy.At present,the radon detector calibration in seismic systems in China is faced with a series of bottleneck problems,such as aging and scrap,acquisition difficulties,high supervision costs,and transportation limitations of radon sources.As a result,a large number of radon detectors cannot be accurately calibrated regularly,seriously affecting the accuracy and reliability of radon observation data in China.To solve this problem,a new calibration method for radon detectors was established.The advantage of this method is that the dangerous radioactive substance,i.e.,the radon source,can be avoided,but only“standard instruments”and water samples with certain dissolved radon concentrations can be used to realize radon detector calibration.This method avoids the risk of radioactive leakage and solves the current widespread difficulties and bottleneck of radon detector calibration in seismic systems in China.The comparison experiment with the traditional calibration method shows that the error of the calibration coefficient obtained by the new method is less than 5%compared with that by the traditional method,which meets the requirements of seismic observation systems,confirming the reliability of the new method.This new method can completely replace the traditional calibration method of using a radon source in seismic systems. 展开更多
关键词 radon detector calibration standard instrument scintillation chamber radon source
下载PDF
Kinematic calibration under the expectation maximization framework for exoskeletal inertial motion capture system
10
作者 QIN Weiwei GUO Wenxin +2 位作者 HU Chen LIU Gang SONG Tainian 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第3期769-779,共11页
This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters ... This study presents a kinematic calibration method for exoskeletal inertial motion capture (EI-MoCap) system with considering the random colored noise such as gyroscopic drift.In this method, the geometric parameters are calibrated by the traditional calibration method at first. Then, in order to calibrate the parameters affected by the random colored noise, the expectation maximization (EM) algorithm is introduced. Through the use of geometric parameters calibrated by the traditional calibration method, the iterations under the EM framework are decreased and the efficiency of the proposed method on embedded system is improved. The performance of the proposed kinematic calibration method is compared to the traditional calibration method. Furthermore, the feasibility of the proposed method is verified on the EI-MoCap system. The simulation and experiment demonstrate that the motion capture precision is significantly improved by 16.79%and 7.16%respectively in comparison to the traditional calibration method. 展开更多
关键词 human motion capture kinematic calibration EXOSKELETON gyroscopic drift expectation maximization(EM)
下载PDF
Calibration of Nondestructive Assay Instruments: An Application of Linear Regression and Propagation of Variance
11
作者 Stephen Croft Tom Burr 《Applied Mathematics》 2014年第5期785-798,共14页
Several nondestructive assay (NDA) methods to quantify special nuclear materials use calibration curves that are linear in the predictor, either directly or as an intermediate step. The linear response model is also o... Several nondestructive assay (NDA) methods to quantify special nuclear materials use calibration curves that are linear in the predictor, either directly or as an intermediate step. The linear response model is also often used to illustrate the fundamentals of calibration, and is the usual detector behavior assumed when evaluating detection limits. It is therefore important for the NDA community to have a common understanding of how to implement a linear calibration according to the common method of least squares and how to assess uncertainty in inferred nuclear quantities during the prediction stage following calibration. Therefore, this paper illustrates regression, residual diagnostics, effect of estimation errors in estimated variances used for weighted least squares, and variance propagation in a form suitable for implementation. Before the calibration can be used, a transformation of axes is required;this step, along with variance propagation is not currently explained in available NDA standard guidelines. The role of systematic and random uncertainty is illustrated and expands on that given previously for the chosen practical NDA example. A listing of open-source software is provided in the Appendix. 展开更多
关键词 Linear calibration Estimation Errors in WEIGHTS for Weighted Least SQUARES NON-DESTRUCTIVE ASSAY Variance PROPAGATION
下载PDF
A real-time calibration method based on time-to-digital converter for accelerator timing system
12
作者 Qi-Hao Duan Liang Ge +2 位作者 Yan-Hao Jia Jie-Yu Zhu Wei Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期127-140,共14页
The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed ov... The high-intensity heavy-ion accelerator facility(HIAF)is a scientific research facility complex composed of multiple cas-cade accelerators of different types,which pose a scheduling problem for devices distributed over a certain range of 2 km,involving over a hundred devices.The white rabbit,a technology-enhancing Gigabit Ethernet,has shown the capability of scheduling distributed timing devices but still faces the challenge of obtaining real-time synchronization calibration param-eters with high precision.This study presents a calibration system based on a time-to-digital converter implemented on an ARM-based System-on-Chip(SoC).The system consists of four multi-sample delay lines,a bubble-proof encoder,an edge controller for managing data from different channels,and a highly effective calibration module that benefits from the SoC architecture.The performance was evaluated with an average RMS precision of 5.51 ps by measuring the time intervals from 0 to 24,000 ps with 120,000 data for every test.The design presented in this study refines the calibration precision of the HIAF timing system.This eliminates the errors caused by manual calibration without efficiency loss and provides data support for fault diagnosis.It can also be easily tailored or ported to other devices for specific applications and provides more space for developing timing systems for particle accelerators,such as white rabbits on HIAF. 展开更多
关键词 HIAF White rabbit calibration system Time-to-digital converter(TDC)
下载PDF
A Weakly-Supervised Crowd Density Estimation Method Based on Two-Stage Linear Feature Calibration
13
作者 Yong-Chao Li Rui-Sheng Jia +1 位作者 Ying-Xiang Hu Hong-Mei Sun 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第4期965-981,共17页
In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd dat... In a crowd density estimation dataset,the annotation of crowd locations is an extremely laborious task,and they are not taken into the evaluation metrics.In this paper,we aim to reduce the annotation cost of crowd datasets,and propose a crowd density estimation method based on weakly-supervised learning,in the absence of crowd position supervision information,which directly reduces the number of crowds by using the number of pedestrians in the image as the supervised information.For this purpose,we design a new training method,which exploits the correlation between global and local image features by incremental learning to train the network.Specifically,we design a parent-child network(PC-Net)focusing on the global and local image respectively,and propose a linear feature calibration structure to train the PC-Net simultaneously,and the child network learns feature transfer factors and feature bias weights,and uses the transfer factors and bias weights to linearly feature calibrate the features extracted from the Parent network,to improve the convergence of the network by using local features hidden in the crowd images.In addition,we use the pyramid vision transformer as the backbone of the PC-Net to extract crowd features at different levels,and design a global-local feature loss function(L2).We combine it with a crowd counting loss(LC)to enhance the sensitivity of the network to crowd features during the training process,which effectively improves the accuracy of crowd density estimation.The experimental results show that the PC-Net significantly reduces the gap between fullysupervised and weakly-supervised crowd density estimation,and outperforms the comparison methods on five datasets of Shanghai Tech Part A,ShanghaiTech Part B,UCF_CC_50,UCF_QNRF and JHU-CROWD++. 展开更多
关键词 Crowd density estimation linear feature calibration vision transformer weakly-supervision learning
下载PDF
Calibration of soft sensor by using Just-in-time modeling and Ada Boost learning method 被引量:11
14
作者 Huan Min Xionglin Luo 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第8期1038-1046,共9页
Soft sensor is an efficacious solution to predict the hard-to-measure target variable by using the process variables.In practical application scenarios, however, the feedback cycle of target variable is usually larger... Soft sensor is an efficacious solution to predict the hard-to-measure target variable by using the process variables.In practical application scenarios, however, the feedback cycle of target variable is usually larger than that of the process variables, which causes the deficiency of prediction errors. Consequently soft sensor cannot be calibrated timely and deteriorates. We proposed a soft sensor calibration method by using Just-in-time modeling and Ada Boost learning method. A moving window consisting of a primary part and a secondary part is constructed.The primary part is made of history data from certain number of constant feedback cycles of target variable and the secondary part includes some coarse target values estimated initially by Just-in-time modeling during the latest feedback cycle of target variable. The data set of the whole moving window is processed by Ada Boost learning method to build an auxiliary estimation model and then target variable values of the latest corresponding feedback cycle are reestimated. Finally the soft sensor model is calibrated by using the reestimated target variable values when the target feedback is unavailable; otherwise using the feedback value. The feasibility and effectiveness of the proposed calibration method is tested and verified through a series of comparative experiments on a pH neutralization facility in our laboratory. 展开更多
关键词 Process control Measurement Soft sensor calibration DETERIORATION Moving WINDOW JUST-IN-TIME ADA BOOST
下载PDF
Global Calibration Method for Monocular Multi-View System Using Rotational Dual-Target
15
作者 Kun He Hongwei He 《Open Journal of Applied Sciences》 2024年第5期1192-1203,共12页
To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calib... To make the problems of existing high requirements of calibration tools, complex global calibration process addressed for monocular multi-view visual measurement system during measurement, in the paper, a global calibration method is proposed for the geometric properties of rotational correlation motion and the absolute orientation of the field of view without over lap. Firstly, a dual-camera system is constructed for photographing and collecting the rotating image sequence of two flat targets rigidly connected by a long rod at different positions, and based on the known parameters, such as, target feature image, world coordinates, camera internal parameters and so on, then the global PnP optimization method is used to solve the rotation axis and the reference point at different positions;Then, the absolute orientation matrix is constructed based on the parameters of rotation axis, reference point and connecting rod length obtained by this method. In the end, the singular value decomposition method is used to find the optimal rotation matrix, and then get the translation matrix. It’s shown based on simulation and actual tests that in comparison with the existing methods, the maximum attitude and pose errors is 0.0083˚ and 0.3657 mm, respectively, which improves the accuracy by 27.8% and 24.4%, respectively. The calibration device in this paper is simple, and there are no parallel, vertical and coplanar requirements between multiple rotating positions. At the same time, in view of the calibration accuracy, the accuracy requirements of most application scenarios can be met. 展开更多
关键词 Machine Vision Accurate Demarcating Global calibration Absolute Orientation
下载PDF
A Precise Calibration Method on Phase Center of Uplink Antenna Array Considering Its Actual Pointing 被引量:4
16
作者 Zongchun LI Zhiyong LU +4 位作者 Guanyu ZHANG Bo LIU Qiqiang FENG Yinggang GUO Hua HE 《Journal of Geodesy and Geoinformation Science》 2020年第1期93-101,共9页
With regard to the inferior techniques and low accuracy of phase center calibration of an antenna array, this paper proposes a new calibration method considering the actual antenna pointing by introducing a precise en... With regard to the inferior techniques and low accuracy of phase center calibration of an antenna array, this paper proposes a new calibration method considering the actual antenna pointing by introducing a precise engineering surveying technique to measure the real state of antennas. First, an industrial photogrammetric system is utilized to obtain the coordinates of points on antenna panels in different postures, and the actual pointing of the mechanical axis is obtained via least-squares fitting. Then, based on this, the coordinates of antenna rotation center are obtained by seeking the intersection of mechanical axes via using the matrix method. Finally, the mechanical axis in arbitrary postures is estimated based on the inverse-angle weighting interpolation method, and the reliable phase center is obtained by moving a fixed length from the projective center along the mechanical axis. An uplink antenna array including three ? 3 m antennas is taken as experimental object, and all photogrammetric coordinate systems are unified by the engineering control network, with each antenna phase center precisely calibrated via the proposed method. The results of electrical signal synthesis indicate that this method can effectively overcome the influence of gravity deformation and mechanical installation error, and enhance the synthetic signal magnitude of the uplink antenna array. 展开更多
关键词 UPLINK array phase CENTER ROTATION CENTER actual antenna POINTING THREE-DIMENSION control network PRECISE calibration
下载PDF
Variation in patient dose due to differences in calibration and dosimetry protocols
17
作者 Wazir Muhammad Asad Ullah +5 位作者 Gulzar Khan Tahir Zeb Khan Tauseef Jamaal Fawad Ullah Matiullah Khan Amjad Hussain 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第5期44-49,共6页
For precise and accurate patient dose delivery,the dosimetry system must be calibrated properly according to the recommendations of standard dosimetry protocols such as TG-51 and TRS-398. However, the dosimetry protoc... For precise and accurate patient dose delivery,the dosimetry system must be calibrated properly according to the recommendations of standard dosimetry protocols such as TG-51 and TRS-398. However, the dosimetry protocol followed by a calibration laboratory is usually different from the protocols that are followed by different clinics, which may result in variations in the patient dose.Our prime objective in this study was to investigate the effect of the two protocols on dosimetry measurements.Dose measurements were performed for a Co-60 teletherapy unit and a high-energy Varian linear accelerator with 6 and 15 MV photon and 6, 9, 12, and 15 MeV electron beams, following the recommendations and procedures of the AAPM TG-51 and IAEA TRS-398 dosimetry protocols. The dosimetry systems used for this study were calibrated in a Co-60 radiation beam at the Secondary Standard Dosimetry Laboratory(SSDL) PINSTECH,Pakistan, following the IAEA TRS-398 protocol. The ratio of the measured absorbed doses to water in clinical setting,D_w(TG-51/TRS-398), was 0.999 and 0.997 for 6 and15 MV photon beams,whereas these ratios were 1.013,1.009, 1.003, and 1.000 for 6, 9, 12, and 15 MeV electron beams, respectively. This difference in the absorbed dosesto-water D_w ratio may be attributed mainly due to beam quality(K_Q) and ion recombination correction factor. 展开更多
关键词 Radiation DOSIMETRY DOSIMETRY systems calibrationS PATIENT DOSE Absorbed dose-to-water ratio AAPM TG-51 IAEA TRS-398
下载PDF
Adsorption of Three Commercial Dyes onto Chitosan Beads Using Spectrophotometric Determination and a Multivariate Calibration Method
18
作者 Manuela Mincea Viorica Patrulea +2 位作者 Ana Negrulescu Robert Szabo Vasile Ostafe 《Journal of Water Resource and Protection》 2013年第4期446-457,共12页
A simple and rapid analytical method for the simultaneous quantification of three commercial azo dyes—Tartrazine (TAR), Congo Red (CR), and Amido Black (AB) in water is presented. The simultaneous assessment of the i... A simple and rapid analytical method for the simultaneous quantification of three commercial azo dyes—Tartrazine (TAR), Congo Red (CR), and Amido Black (AB) in water is presented. The simultaneous assessment of the individual concentration of an organic dye in mixtures using a spectrophotometric method is a difficult procedure in analytical chemistry, due to spectral overlapping. This drawback can be overcome if a multivariate calibration method such as Partial Least Squares Regression (PLSR) is used. This study presents a calibration model based on absorption spectra in the 300 - 650 nm range for a set of 20 different mixtures of dyes, followed by the prediction of the concentrations of dyes in 6 validation mixtures, randomly selected, using the PLSR method. Estimated limits of detection (LOD) were 0.106, 0.047 and 0.079 mg/L for TAR, CR, and AB, respectively, and limits of quantification (LOQ) were 0.355, 0.157 and 0.265 mg/L for TAR, CR, and AB, respectively. Quantitative determination of the three azo dyes was performed following optimized adsorption experiments onto chitosan beads of mixtures of TAR, CR and AB. Adsorption isotherm and kinetic studies were carried out, proving that the proposed PLSR method is rapid, accurate and reliable. 展开更多
关键词 Univariate calibration MULTIVARIATE calibration Spectral Overlap Partial Least SQUARES Regression COMMERCIAL DYES ADSORPTION
下载PDF
Some Comments on Pressure Calibration over Lower Mantle Conditions
19
作者 Hui Zhao D. J. Weidner Yun Liu 《矿物岩石地球化学通报》 CAS CSCD 2007年第z1期527-528,共2页
  Recently, there is an urgent need in high pressure community for a pressure scale whose accuracy is comparable to the high precision of experimental data.One of the difficulties is the lack of an absolute scale,in...   Recently, there is an urgent need in high pressure community for a pressure scale whose accuracy is comparable to the high precision of experimental data.One of the difficulties is the lack of an absolute scale,in particular at high temperature, to evaluate the EOS of standard materials.…… 展开更多
关键词 pressure calibration EQUATION of state (EOS) PEROVSKITE MANTLE COMPOSITION pyrolite shock WAVE
下载PDF
Wavelength calibration and spectral analysis of vacuum ultraviolet spectroscopy in EAST
20
作者 计华健 张洪明 +6 位作者 吕波 Cheonho BAE 何梁 林子超 尹相辉 沈永才 戴舒宇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第8期37-43,共7页
A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength c... A vacuum ultraviolet(VUV)spectroscopy with a focal length of 1 m has been engineered specifically for observing edge impurity emissions in Experimental Advanced Superconducting Tokamak(EAST).In this study,wavelength calibration for the VUV spectroscopy is achieved utilizing a zinc lamp.The grating angle and charge-coupled device(CCD)position are carefully calibrated for different wavelength positions.The wavelength calibration of the VUV spectroscopy is crucial for improving the accuracy of impurity spectral data,and is required to identify more impurity spectral lines for impurity transport research.Impurity spectra of EAST plasmas have also been obtained in the wavelength range of 50–300 nm with relatively high spectral resolution.It is found that the impurity emissions in the edge region are still dominated by low-Z impurities,such as carbon,oxygen,and nitrogen,albeit with the application of fulltungsten divertors on the EAST tokamak. 展开更多
关键词 vacuum ultraviolet spectroscopy wavelength calibration impurity spectra
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部