This study investigated the floc aggregation, average floc size, floc size variance and floc growth velocity when ferric chloride (FeCl3) and polyferric chloride (PFC) were used to treat the simulated water sample...This study investigated the floc aggregation, average floc size, floc size variance and floc growth velocity when ferric chloride (FeCl3) and polyferric chloride (PFC) were used to treat the simulated water samples. The factors including coagulant dose, ionic strength and solution pH, which affect the floc aggregation, were studied. Experiments were carried out in a bench-scale reactor using photometric dispersion analyzer ( PDA). Results showed that there were great differences between the floc aggregation of PFC and FeCl3. The average floc size and fioc growth velocity of PFC were much larger than those of FeCl3. Compared with FeCl3, PFC gave a better coagulation performance in wider range of pH, dosage and ionic strength. It was also found that the coagulation efficiency of PFC did not depend on average floc size but on floc growth velocity.展开更多
Objective Coagulation abnormalities are common and prognostically significant in intensive care units(ICUs)and are associated with increased mortality.This study aimed to explore the association between the levels of ...Objective Coagulation abnormalities are common and prognostically significant in intensive care units(ICUs)and are associated with increased mortality.This study aimed to explore the association between the levels of coagulation markers and the risk of mortality among ICU patients with coagulation abnormalities.Methods This retrospective study investigated patients with coagulation abnormalities in the ICU between January 2021 and December 2022.The initial point for detecting hemostatic biomarkers due to clinical assessment of coagulation abnormalities was designated day 0.Patients were followed up for 28 days,and multivariate logistic regression analysis was utilized to identify risk factors for mortality.Results Of the 451 patients analyzed,115 died,and 336 were alive at the end of the 28-day period.Multivariate analysis revealed that elevated thrombin-antithrombin complex(TAT),tissue plasminogen activator inhibitor complex(tPAIC),prolonged prothrombin time,and thrombocytopenia were independent risk factors for mortality.For nonovert disseminated intravascular coagulation(DIC)patients,older age and thrombocytopenia were associated with increased risks of mortality,whereas elevated levels of plasminα2-plasmin inhibitor complex(PIC)were found to be independent predictors of survival.In patients with overt DIC,elevated levels of tPAIC were independently associated with increased risks of mortality.Nevertheless,thrombocytopenia was independently associated with increased risks of mortality in patients with pre-DIC.Conclusion Coagulation markers such as the TAT,tPAIC,PIC,and platelet count were significantly associated with mortality,underscoring the importance of maintaining a balance between coagulation and fibrinolysis.These findings highlight the potential for targeted therapeutic interventions based on specific coagulation markers to improve patient outcomes.展开更多
This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inerti...This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature.展开更多
BACKGROUND:Disseminated intravascular coagulation(DIC)is associated with increased mortality in sepsis patients.In this study,we aimed to assess the clinical ability of sepsis-induced coagulopathy(SIC)and sepsis-assoc...BACKGROUND:Disseminated intravascular coagulation(DIC)is associated with increased mortality in sepsis patients.In this study,we aimed to assess the clinical ability of sepsis-induced coagulopathy(SIC)and sepsis-associated coagulopathy(SAC)criteria in identifying overt-DIC and preDIC status in sepsis patients.METHODS:Data from 419 sepsis patients were retrospectively collected from July 2018 to December 2022.The performances of the SIC and SAC were assessed to identify overt-DIC on days 1,3,7,or 14.The SIC status or SIC score on day 1,the SAC status or SAC score on day 1,and the sum of the SIC or SAC scores on days 1 and 3 were compared in terms of their ability to identify pre-DIC.The SIC or SAC status on day 1 was evaluated as a pre-DIC indicator for anticoagulant initiation.RESULTS:On day 1,the incidences of coagulopathy according to overt-DIC,SIC and SAC criteria were 11.7%,22.0%and 31.5%,respectively.The specificity of SIC for identifying overt-DIC was significantly higher than that of the SAC criteria from day 1 to day 14(P<0.05).On day 1,the SIC score with a cut-off value>3 had a significantly higher sensitivity(72.00%)and area under the curve(AUC)(0.69)in identifying pre-DIC than did the SIC or SAC status(sensitivity:SIC status 44.00%,SAC status 52.00%;AUC:SIC status 0.62,SAC status 0.61).The sum of the SIC scores on days 1 and 3 had a higher AUC value for identifying the pre-DIC state than that of SAC(0.79 vs.0.69,P<0.001).Favorable effects of anticoagulant therapy were observed in SIC(adjusted hazard ratio[HR]=0.216,95%confidence interval[95%CI]:0.060–0.783,P=0.018)and SAC(adjusted HR=0.146,95%CI:0.041–0.513,P=0.003).CONCLUSION:The SIC and SAC seem to be valuable for predicting overt-DIC.The sum of SIC scores on days 1 and 3 has the potential to help identify pre-DIC.展开更多
Fluid catalytic cracking (FCC) salty wastewaters, containing quaternary ammonium compounds (QACs), are very difficult to treat by biochemical process. Anoxic/oxic (A/O) biochemical system, based on nitrification and d...Fluid catalytic cracking (FCC) salty wastewaters, containing quaternary ammonium compounds (QACs), are very difficult to treat by biochemical process. Anoxic/oxic (A/O) biochemical system, based on nitrification and denitrification reactions, was used to assess their possible biodegradation. Because of the negative effects of high salt concentration (3%), heavy metals and toxic organic matter on microorganisms’ activities, some techniques consisting of dilution, coagulation and flocculation, and ozonation pretreatments, were gradually tested to evaluate chemical oxygen demand (COD), ammonia-nitrogen (ammonia-N) and total nitrogen (TN) removal rates. In this process of FCC wastewater, starting with university-domesticated sludge, the ammonia-N and TN removal rates were worst. However, when using domesticated SBR’s sludge and operating with five-fold daily diluted influent (thus reducing salt concentration), the ammonia-N removal reached about 57% while the TN removal rate was less than 37% meaning an amelioration of the nitrification process. However, by reducing the dilution factors, these results were inflected after some days of operation, with ammonia-N removal decreasing and TN barely removed meaning a poor nitrification. Even by reducing heavy metals concentration with coagulation/flocculation process, the results never changed. Thereafter, by using ozonation pre-treatment to degrade the detected organic matter of di-tert-butylphenol and certain isoparaffins, COD, ammonia-N and TN removal rates reached 92%, 62% and 61%, respectively. These results showed that the activities of the microorganisms were increased, thus indicating a net denitrification and nitrification reactions improvement.展开更多
BACKGROUND The incidence of Barrett’s esophagus(BE)in China is lower compared to the Western populations.Hence,studies conducted in the Chinese population has been limited.The current treatment options available for ...BACKGROUND The incidence of Barrett’s esophagus(BE)in China is lower compared to the Western populations.Hence,studies conducted in the Chinese population has been limited.The current treatment options available for BE treatment includes argon plasma coagulation(APC),radiofrequency ablation and cryoablation,all with varying degrees of success.AIM To determine the efficacy and safety of HybridAPC in the treatment of BE.METHODS The study cohort consisted of patients with BE who underwent HybridAPC ablation treatment.These procedures were performed by seven endoscopists from different tertiary hospitals.The duration of the procedure,curative rate,complications and recurrent rate by 1-year follow-up were recorded.RESULTS Eighty individuals were enrolled for treatment from July 2017 to June 2020,comprising of 39 males and 41 females with a median age of 54 years(range,30 to 83 years).The technical success rate of HybridAPC was 100%and the overall curative rate was 98.15%.No severe complications occurred during the operation.BE cases were classified as short-segment BE and long-segment BE.Patients with short-segment BE were all considered cured without complications.Thirty-six patients completed the one-year follow-up without recurrence.Twenty-four percent had mild dysplasia which were all resolved with one post-procedural treatment.The mean duration of the procedure was 10.94±6.52 min.CONCLUSION Treatment of BE with HybridAPC was found to be a simple and quick procedure that is safe and effective during the short-term follow-up,especially in cases of short-segment BE.This technique could be considered as a feasible alternative ablation therapy for BE.展开更多
[Objective] The aim was to treat acidic wastewater containing thallium by enhanced coagulation oxidation process. [Method] Enhanced coagulation oxidation process was made use of to remove thallium in the acidic wastew...[Objective] The aim was to treat acidic wastewater containing thallium by enhanced coagulation oxidation process. [Method] Enhanced coagulation oxidation process was made use of to remove thallium in the acidic wastewater in the experiment under the condition of 0.05 kg/L of potassium permanganate, 30% hydrogen peroxide and 0.05 kg/L calcium hypochlorite as oxidant, together with 0.092 kg/L CaO as coagulation. [Result] The results showed that thallium removal efficiencies achieved 99.98%, 99.1% and 99.95% when dosages of KMnO4, H2O2and Ca(ClO)2were added at 20, 2.2 and 37 ml, respectively, under the condition of 30 ml 0.092kg/L CaO being dosed and 99.93%, 99.69% and 99.98% were achieved when different dosages of CaO were added at 25, 35 and 25 ml, under the condition of 20ml KMnO4, 2.2 ml H2O2and 37 ml Ca(ClO)2respectively. [Conclusion] The experiment demonstrates that good removal effects of removal thallium from the acidic wastewater would be achieved by enhanced coagulation oxidation process.展开更多
Snake venoms,especially those from the two subfamilies,Crotalinae and Viperinae,contained a lot of serine proteases. They were responsible for the hemorrhage,shock,or disorder of blood coagulation after envenomation. ...Snake venoms,especially those from the two subfamilies,Crotalinae and Viperinae,contained a lot of serine proteases. They were responsible for the hemorrhage,shock,or disorder of blood coagulation after envenomation. They acted,by activating,inactivating,or other converting effects,on almost all the components of hemostatic and fibrinolytic systems. Their sequences were homologous to trypsin-kallikrein serine proteases. Variation of primary sequences out of active center results in the difference of substrate specificities and the further difference of biological and pharmacological activities. Because of their common and unique properties compared to their physiological corresponding factors,snake venom proteases are proved to be an excellent model for the study of protease substrate discriminating mechanism. Furthermore,they have found an important position both in basic research and application of hemostasis and thrombosis in clinic.展开更多
Objective: To evaluate the efficacy and safety of percutaneous microwave coagulation therapy (PMCT) for patients with primary and metastatic hepatic tumors.Methods: The enrolled 100 patients with 186 tumor nodules who...Objective: To evaluate the efficacy and safety of percutaneous microwave coagulation therapy (PMCT) for patients with primary and metastatic hepatic tumors.Methods: The enrolled 100 patients with 186 tumor nodules who underwent PMCT included 79 cases of primary or recurrent liver cancers and 21 cases of metastatic liver cancer. The tumors were divided into two groups according to the tumor size in diameter: group A, 0.5 cm?<3 cm; group B, ≥3 cm?<5 cm. Under local and/or epidural anesthesia, a single percutaneous microwave antenna (or two antennas array applicator) was inserted directly into the tumor in the liver for thermo-coagulation with the aid of ultrasound guidance.Results: Among the 186 lesions in 100 patients with primary and metastatic liver cancers, in group A, 123 (66%) were coagulated once. A Follow-up of 6–12 months demonstrated that 112 lesions (91%) showed no local recurrence by CT or MRI; In group B, of the 63 lesions (33.87%) coagulated twice, 31 (49%) showed no local recurrence by CT or MRI during a follow-up of 6 months. There were no serious clinical side effects or complications in all the PMCT patients.Conclusion: PMCT gives satisfactory curative effect on tumors with <3 cm in size. It is partly effective on lesions ≥3 cm?<5 cm in size. It is a minimally invasive and effective therapy, can be used safely in the field of percutaneous hepatis surgery, and carried out even in patients with poor liver function. Key words hepatocellular carcinoma - microwave - coagulation - therapy展开更多
The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sens...The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sensor (AE) with motor current sensor was presented. The parallel communication between control system of machine tools, the monitoring intelligent system,and several decision-making systems for identifying tool cutting state was established It can auto - matically select the sensor way ,monitoring mode and identifying method in machining process- ing so as to build a successful and effective intelligent system for on -line and real-time moni- toring cutting tool states in FMS.展开更多
This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current te...This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate.展开更多
The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through...The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through on-line solution and off-line aging treatment but decreases after off-line solution treatment. By X-ray diffractometry, optical microscopy, differential thermal analysis, scanning electron microscopy and X-ray energy dispersive spectroscopy, it is found that the microstructures of the die-cast AZ91D magnesium alloy before and after on-line solution and off-line aging are similar, consisting of α-Mg and β-Al12Mg17. The precipitation of Al element is prevented by on-line solution so that the effect of solid solution strengthening is enhanced. The β-Al12Mg17 phases precipitate from supersaturated Mg solid solution after off-line aging treatment, and lead to microstructure refinement of AZ91D alloy, so the effect of precipitation hardening is enhanced. The β-Al12Mg17 phases dissolve in the substructure after off-line solution treatment, which leads to that the grain boundary strengthening phase is reduced significantly and the hardness of die cast AZ91D is reduced.展开更多
A composite control scheme consisting of modepredictive control (MPC) and disturbance observer (DOB) iproposed to solve the control performance degradationproblem of the turbidity of the treated water in the prese...A composite control scheme consisting of modepredictive control (MPC) and disturbance observer (DOB) iproposed to solve the control performance degradationproblem of the turbidity of the treated water in the presence osignificant changes in raw water quality, water flow rate andinternal model mismatch disturbances. The MPC is employedas a feedback controller for the coagulation process with alarge time delay. The DOB is adopted to estimate the severedisturbances in the turbidity control, such as large changes inraw water quality and water flow rate. The estimated valuesare applied for feed-forward compensation to rejecdisturbances. Finally, the disturbance rejection performancesfor step disturbances and time-varying disturbances in thenominal case and model mismatch case are tested. Thesimulation results illustrate that, compared with the MPCmethod, the proposed method can significantly improve thedisturbance rejection performance in the turbidity control othe treated water, no matter if in the presence of externadisturbances or internal model mismatch disturbances.展开更多
文摘This study investigated the floc aggregation, average floc size, floc size variance and floc growth velocity when ferric chloride (FeCl3) and polyferric chloride (PFC) were used to treat the simulated water samples. The factors including coagulant dose, ionic strength and solution pH, which affect the floc aggregation, were studied. Experiments were carried out in a bench-scale reactor using photometric dispersion analyzer ( PDA). Results showed that there were great differences between the floc aggregation of PFC and FeCl3. The average floc size and fioc growth velocity of PFC were much larger than those of FeCl3. Compared with FeCl3, PFC gave a better coagulation performance in wider range of pH, dosage and ionic strength. It was also found that the coagulation efficiency of PFC did not depend on average floc size but on floc growth velocity.
基金supported by grants from National Key R&D Program of China(No.2023YFC2507800)ECCM Program of Clinical Research Centre of Shandong University(No.2021SDUCRCB008)+2 种基金Young Taishan Scholar Foundation of Shandong Province(No.tsqn201812133)the Fundamental Research Funds of Shandong University(No.2020QNQT001)National Natural Science Foundation of China(No.81900124).
文摘Objective Coagulation abnormalities are common and prognostically significant in intensive care units(ICUs)and are associated with increased mortality.This study aimed to explore the association between the levels of coagulation markers and the risk of mortality among ICU patients with coagulation abnormalities.Methods This retrospective study investigated patients with coagulation abnormalities in the ICU between January 2021 and December 2022.The initial point for detecting hemostatic biomarkers due to clinical assessment of coagulation abnormalities was designated day 0.Patients were followed up for 28 days,and multivariate logistic regression analysis was utilized to identify risk factors for mortality.Results Of the 451 patients analyzed,115 died,and 336 were alive at the end of the 28-day period.Multivariate analysis revealed that elevated thrombin-antithrombin complex(TAT),tissue plasminogen activator inhibitor complex(tPAIC),prolonged prothrombin time,and thrombocytopenia were independent risk factors for mortality.For nonovert disseminated intravascular coagulation(DIC)patients,older age and thrombocytopenia were associated with increased risks of mortality,whereas elevated levels of plasminα2-plasmin inhibitor complex(PIC)were found to be independent predictors of survival.In patients with overt DIC,elevated levels of tPAIC were independently associated with increased risks of mortality.Nevertheless,thrombocytopenia was independently associated with increased risks of mortality in patients with pre-DIC.Conclusion Coagulation markers such as the TAT,tPAIC,PIC,and platelet count were significantly associated with mortality,underscoring the importance of maintaining a balance between coagulation and fibrinolysis.These findings highlight the potential for targeted therapeutic interventions based on specific coagulation markers to improve patient outcomes.
文摘This paper studies a strongly convergent inertial forward-backward-forward algorithm for the variational inequality problem in Hilbert spaces.In our convergence analysis,we do not assume the on-line rule of the inertial parameters and the iterates,which have been assumed by several authors whenever a strongly convergent algorithm with an inertial extrapolation step is proposed for a variational inequality problem.Consequently,our proof arguments are different from what is obtainable in the relevant literature.Finally,we give numerical tests to confirm the theoretical analysis and show that our proposed algorithm is superior to related ones in the literature.
基金supported by the National Key Research and Development Program of China(2021YFC2501800)Shanghai Committee of Science and Technology(20Y11900100,21MC1930400,and 20DZ2261200)Clinical Research Plan of Shanghai Hospital Development Center(SHDC2020CR4059)。
文摘BACKGROUND:Disseminated intravascular coagulation(DIC)is associated with increased mortality in sepsis patients.In this study,we aimed to assess the clinical ability of sepsis-induced coagulopathy(SIC)and sepsis-associated coagulopathy(SAC)criteria in identifying overt-DIC and preDIC status in sepsis patients.METHODS:Data from 419 sepsis patients were retrospectively collected from July 2018 to December 2022.The performances of the SIC and SAC were assessed to identify overt-DIC on days 1,3,7,or 14.The SIC status or SIC score on day 1,the SAC status or SAC score on day 1,and the sum of the SIC or SAC scores on days 1 and 3 were compared in terms of their ability to identify pre-DIC.The SIC or SAC status on day 1 was evaluated as a pre-DIC indicator for anticoagulant initiation.RESULTS:On day 1,the incidences of coagulopathy according to overt-DIC,SIC and SAC criteria were 11.7%,22.0%and 31.5%,respectively.The specificity of SIC for identifying overt-DIC was significantly higher than that of the SAC criteria from day 1 to day 14(P<0.05).On day 1,the SIC score with a cut-off value>3 had a significantly higher sensitivity(72.00%)and area under the curve(AUC)(0.69)in identifying pre-DIC than did the SIC or SAC status(sensitivity:SIC status 44.00%,SAC status 52.00%;AUC:SIC status 0.62,SAC status 0.61).The sum of the SIC scores on days 1 and 3 had a higher AUC value for identifying the pre-DIC state than that of SAC(0.79 vs.0.69,P<0.001).Favorable effects of anticoagulant therapy were observed in SIC(adjusted hazard ratio[HR]=0.216,95%confidence interval[95%CI]:0.060–0.783,P=0.018)and SAC(adjusted HR=0.146,95%CI:0.041–0.513,P=0.003).CONCLUSION:The SIC and SAC seem to be valuable for predicting overt-DIC.The sum of SIC scores on days 1 and 3 has the potential to help identify pre-DIC.
文摘Fluid catalytic cracking (FCC) salty wastewaters, containing quaternary ammonium compounds (QACs), are very difficult to treat by biochemical process. Anoxic/oxic (A/O) biochemical system, based on nitrification and denitrification reactions, was used to assess their possible biodegradation. Because of the negative effects of high salt concentration (3%), heavy metals and toxic organic matter on microorganisms’ activities, some techniques consisting of dilution, coagulation and flocculation, and ozonation pretreatments, were gradually tested to evaluate chemical oxygen demand (COD), ammonia-nitrogen (ammonia-N) and total nitrogen (TN) removal rates. In this process of FCC wastewater, starting with university-domesticated sludge, the ammonia-N and TN removal rates were worst. However, when using domesticated SBR’s sludge and operating with five-fold daily diluted influent (thus reducing salt concentration), the ammonia-N removal reached about 57% while the TN removal rate was less than 37% meaning an amelioration of the nitrification process. However, by reducing the dilution factors, these results were inflected after some days of operation, with ammonia-N removal decreasing and TN barely removed meaning a poor nitrification. Even by reducing heavy metals concentration with coagulation/flocculation process, the results never changed. Thereafter, by using ozonation pre-treatment to degrade the detected organic matter of di-tert-butylphenol and certain isoparaffins, COD, ammonia-N and TN removal rates reached 92%, 62% and 61%, respectively. These results showed that the activities of the microorganisms were increased, thus indicating a net denitrification and nitrification reactions improvement.
文摘BACKGROUND The incidence of Barrett’s esophagus(BE)in China is lower compared to the Western populations.Hence,studies conducted in the Chinese population has been limited.The current treatment options available for BE treatment includes argon plasma coagulation(APC),radiofrequency ablation and cryoablation,all with varying degrees of success.AIM To determine the efficacy and safety of HybridAPC in the treatment of BE.METHODS The study cohort consisted of patients with BE who underwent HybridAPC ablation treatment.These procedures were performed by seven endoscopists from different tertiary hospitals.The duration of the procedure,curative rate,complications and recurrent rate by 1-year follow-up were recorded.RESULTS Eighty individuals were enrolled for treatment from July 2017 to June 2020,comprising of 39 males and 41 females with a median age of 54 years(range,30 to 83 years).The technical success rate of HybridAPC was 100%and the overall curative rate was 98.15%.No severe complications occurred during the operation.BE cases were classified as short-segment BE and long-segment BE.Patients with short-segment BE were all considered cured without complications.Thirty-six patients completed the one-year follow-up without recurrence.Twenty-four percent had mild dysplasia which were all resolved with one post-procedural treatment.The mean duration of the procedure was 10.94±6.52 min.CONCLUSION Treatment of BE with HybridAPC was found to be a simple and quick procedure that is safe and effective during the short-term follow-up,especially in cases of short-segment BE.This technique could be considered as a feasible alternative ablation therapy for BE.
基金National Natural Science Foundation(51208122)Department of Science and Technology of Guangdong Province(2010B030900008)New Special Science and Technology Project of Pearl River and College Students’Innovative Entrepreneurial Training Plan Project in Guangdong Province~~
文摘[Objective] The aim was to treat acidic wastewater containing thallium by enhanced coagulation oxidation process. [Method] Enhanced coagulation oxidation process was made use of to remove thallium in the acidic wastewater in the experiment under the condition of 0.05 kg/L of potassium permanganate, 30% hydrogen peroxide and 0.05 kg/L calcium hypochlorite as oxidant, together with 0.092 kg/L CaO as coagulation. [Result] The results showed that thallium removal efficiencies achieved 99.98%, 99.1% and 99.95% when dosages of KMnO4, H2O2and Ca(ClO)2were added at 20, 2.2 and 37 ml, respectively, under the condition of 30 ml 0.092kg/L CaO being dosed and 99.93%, 99.69% and 99.98% were achieved when different dosages of CaO were added at 25, 35 and 25 ml, under the condition of 20ml KMnO4, 2.2 ml H2O2and 37 ml Ca(ClO)2respectively. [Conclusion] The experiment demonstrates that good removal effects of removal thallium from the acidic wastewater would be achieved by enhanced coagulation oxidation process.
文摘Snake venoms,especially those from the two subfamilies,Crotalinae and Viperinae,contained a lot of serine proteases. They were responsible for the hemorrhage,shock,or disorder of blood coagulation after envenomation. They acted,by activating,inactivating,or other converting effects,on almost all the components of hemostatic and fibrinolytic systems. Their sequences were homologous to trypsin-kallikrein serine proteases. Variation of primary sequences out of active center results in the difference of substrate specificities and the further difference of biological and pharmacological activities. Because of their common and unique properties compared to their physiological corresponding factors,snake venom proteases are proved to be an excellent model for the study of protease substrate discriminating mechanism. Furthermore,they have found an important position both in basic research and application of hemostasis and thrombosis in clinic.
文摘Objective: To evaluate the efficacy and safety of percutaneous microwave coagulation therapy (PMCT) for patients with primary and metastatic hepatic tumors.Methods: The enrolled 100 patients with 186 tumor nodules who underwent PMCT included 79 cases of primary or recurrent liver cancers and 21 cases of metastatic liver cancer. The tumors were divided into two groups according to the tumor size in diameter: group A, 0.5 cm?<3 cm; group B, ≥3 cm?<5 cm. Under local and/or epidural anesthesia, a single percutaneous microwave antenna (or two antennas array applicator) was inserted directly into the tumor in the liver for thermo-coagulation with the aid of ultrasound guidance.Results: Among the 186 lesions in 100 patients with primary and metastatic liver cancers, in group A, 123 (66%) were coagulated once. A Follow-up of 6–12 months demonstrated that 112 lesions (91%) showed no local recurrence by CT or MRI; In group B, of the 63 lesions (33.87%) coagulated twice, 31 (49%) showed no local recurrence by CT or MRI during a follow-up of 6 months. There were no serious clinical side effects or complications in all the PMCT patients.Conclusion: PMCT gives satisfactory curative effect on tumors with <3 cm in size. It is partly effective on lesions ≥3 cm?<5 cm in size. It is a minimally invasive and effective therapy, can be used safely in the field of percutaneous hepatis surgery, and carried out even in patients with poor liver function. Key words hepatocellular carcinoma - microwave - coagulation - therapy
文摘The principle and the constitution of an intelligent system for on-line and real-time montitoring tool cutting state were discussed and a synthetic sensors schedule combined a new type fluid acoustic emission sensor (AE) with motor current sensor was presented. The parallel communication between control system of machine tools, the monitoring intelligent system,and several decision-making systems for identifying tool cutting state was established It can auto - matically select the sensor way ,monitoring mode and identifying method in machining process- ing so as to build a successful and effective intelligent system for on -line and real-time moni- toring cutting tool states in FMS.
文摘This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate.
基金Projects (2011BAE22B01, 2011BAE22B06) supported by the National Key Technologies R&D Program During the 12th Five-Year Plan Period of ChinaProject (2010NC018) supported by the Innovation Fund of Inner Mongolia University of Science and Technology, China
文摘The effects of on-line solution, off-line solution and aging heat treatment on the microstructure and hardness of the die-cast AZ91D alloys were investigated. Brinell hardness of die-cast AZ91D alloy increases through on-line solution and off-line aging treatment but decreases after off-line solution treatment. By X-ray diffractometry, optical microscopy, differential thermal analysis, scanning electron microscopy and X-ray energy dispersive spectroscopy, it is found that the microstructures of the die-cast AZ91D magnesium alloy before and after on-line solution and off-line aging are similar, consisting of α-Mg and β-Al12Mg17. The precipitation of Al element is prevented by on-line solution so that the effect of solid solution strengthening is enhanced. The β-Al12Mg17 phases precipitate from supersaturated Mg solid solution after off-line aging treatment, and lead to microstructure refinement of AZ91D alloy, so the effect of precipitation hardening is enhanced. The β-Al12Mg17 phases dissolve in the substructure after off-line solution treatment, which leads to that the grain boundary strengthening phase is reduced significantly and the hardness of die cast AZ91D is reduced.
基金The National Natural Science Foundation of China(No.61504027)the Natural Science Foundation of Jiangsu Province(No.BK20140647)the Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘A composite control scheme consisting of modepredictive control (MPC) and disturbance observer (DOB) iproposed to solve the control performance degradationproblem of the turbidity of the treated water in the presence osignificant changes in raw water quality, water flow rate andinternal model mismatch disturbances. The MPC is employedas a feedback controller for the coagulation process with alarge time delay. The DOB is adopted to estimate the severedisturbances in the turbidity control, such as large changes inraw water quality and water flow rate. The estimated valuesare applied for feed-forward compensation to rejecdisturbances. Finally, the disturbance rejection performancesfor step disturbances and time-varying disturbances in thenominal case and model mismatch case are tested. Thesimulation results illustrate that, compared with the MPCmethod, the proposed method can significantly improve thedisturbance rejection performance in the turbidity control othe treated water, no matter if in the presence of externadisturbances or internal model mismatch disturbances.