The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enri...Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.展开更多
In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illic...In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illicit drugs and metabolites(methamphetamine,amphetamine,morphine,codeine,6-monoacetylmorphine,benzoylecgonine,3,4-methylenedioxymethamphetamine,3,4-methylenedioxyamphetamine,cocaine,ketamine,norketamine,and methcathinone)and cotinine(COT)in wastewater samples.The analysis was performed by loading 2 m L of the sample onto an Oasis hydrophilic-lipophilic balance cartridge and using a cleanup step(5%methanol)to eliminate interference with a total run time of 13 min.The isotope-labeled internal standard method was used to quantify the target substances and correct for unavoidable losses and matrix effects during the on-line SPE process.Typical analytical characteristics used for method validation were sensitivity,linearity,precision,repeatability,recovery,and matrix effects.The limit of detection(LOD)and limit of quantification(LOQ)of each target were set at 0.20 ng/L and 0.50 ng/L,respectively.The linearity was between 0.5 ng/L and250 ng/L,except for that of COT.The intra-and inter-day precisions were<10.45%and 25.64%,respectively,and the relative recovery ranged from 83.74%to 162.26%.The method was used to analyze various wastewater samples from 33 cities in China,and the results were compared with the experimental results of identical samples analyzed using off-line SPE.The difference rate was between 19.91%and-20.44%,and the error range could be considered acceptable.These findings showed that on-line SPE is a suitable alternative to off-line SPE for the analysis of illicit drugs in samples.展开更多
A method of on-line pretreatment coupled to HPLC with fluorescence detection was developed and validated for the determination of nine quinolones in honey samples. This method simplified the complicated process of sam...A method of on-line pretreatment coupled to HPLC with fluorescence detection was developed and validated for the determination of nine quinolones in honey samples. This method simplified the complicated process of sample pretreatment and reduced sample treatment time. Recovery of the quinolones was between 92% - 101% for spiked honey samples. The limit of detection was 0.22 - 3.78 ng/mL (signal/noise ratio = 3). There was good linear correlation between HPLC peak area and concentration of the quinolones, with a linear range of 1.0 - 100.0 ng/mL and correlation coefficients >0.9997. The method proposed was validated for detecting quinolones in honey samples.展开更多
Traditional Chinese medicines(TCMs)possess a rich historical background,unique theoretical framework,remarkable therapeutic efficacy,and abundant resources.However,the modernization and internationalization of TCMs ha...Traditional Chinese medicines(TCMs)possess a rich historical background,unique theoretical framework,remarkable therapeutic efficacy,and abundant resources.However,the modernization and internationalization of TCMs have faced significant obstacles due to their diverse ingredients and unknown mechanisms.To gain deeper insights into the phytochemicals and ensure the quality control of TCMs,there is an urgent need to enhance analytical techniques.Currently,two-dimensional(2D)chromatography,which incorporates two independent separation mechanisms,demonstrates superior separation capabilities compared to the traditional one-dimensional(1D)separation system when analyzing TCMs samples.Over the past decade,new techniques have been continuously developed to gain actionable insights from complex samples.This review presents the recent advancements in the application of multidimensional chromatography for the quality evaluation of TCMs,encompassing 2D-gas chromatography(GC),2D-liquid chromatography(LC),as well as emerging three-dimensional(3D)-GC,3D-LC,and their associated data-processing approaches.These studies highlight the promising potential of multidimensional chromatographic separation for future phytochemical analysis.Nevertheless,the increased separation capability has resulted in higher-order data sets and greater demands for data-processing tools.Considering that multidimensional chromatography is still a relatively nascent research field,further hardware enhancements and the implementation of chemometric methods are necessary to foster its robust development.展开更多
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.
基金Project supported by the National Natural Science Foundation of China (No.20437020)Major Research Program of Chinese Academy of Sciences (No.KZCX3-SW-432).
文摘Seven polycyclic aromatic hydrocarbons (PAHs) in atmospheric particulates were determinated by high performance liquid chromatography (HPLC) with fluorescence detector using direction injection and an on-line enrichment trap column. The method simplified the sample pretreatment, saved time and increased the efficiency. With the on-line trap column, PAHs were separated availably even underground injecting 1.0 ml sample with relatively high column efficiency. The recoveries of the seven PAHs were from 85% to 120% for spiked atmospheric particulate sample. The limit of detection was 15.3-39.6 ng/L (S/N=3.3). There were good linear correlations between the peak areas and concentrations of the seven kinds of PAHs in the range of 1-50 ng/ml with the correlation coefficients over 0.9970. Furthermore, it also indicated that the method is available to determine PAHs in atmospheric particulates well.
基金supported by the National Key Research and Development Program of China(Grant No.:2018YFC0807402)the National Natural Science Foundation of China(Grant No.:82073810)。
文摘In this study,we developed a novel on-line solid phase extraction(SPE)-ultra-high-performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS)-based analytical method for simultaneously quantifying 12 illicit drugs and metabolites(methamphetamine,amphetamine,morphine,codeine,6-monoacetylmorphine,benzoylecgonine,3,4-methylenedioxymethamphetamine,3,4-methylenedioxyamphetamine,cocaine,ketamine,norketamine,and methcathinone)and cotinine(COT)in wastewater samples.The analysis was performed by loading 2 m L of the sample onto an Oasis hydrophilic-lipophilic balance cartridge and using a cleanup step(5%methanol)to eliminate interference with a total run time of 13 min.The isotope-labeled internal standard method was used to quantify the target substances and correct for unavoidable losses and matrix effects during the on-line SPE process.Typical analytical characteristics used for method validation were sensitivity,linearity,precision,repeatability,recovery,and matrix effects.The limit of detection(LOD)and limit of quantification(LOQ)of each target were set at 0.20 ng/L and 0.50 ng/L,respectively.The linearity was between 0.5 ng/L and250 ng/L,except for that of COT.The intra-and inter-day precisions were<10.45%and 25.64%,respectively,and the relative recovery ranged from 83.74%to 162.26%.The method was used to analyze various wastewater samples from 33 cities in China,and the results were compared with the experimental results of identical samples analyzed using off-line SPE.The difference rate was between 19.91%and-20.44%,and the error range could be considered acceptable.These findings showed that on-line SPE is a suitable alternative to off-line SPE for the analysis of illicit drugs in samples.
文摘A method of on-line pretreatment coupled to HPLC with fluorescence detection was developed and validated for the determination of nine quinolones in honey samples. This method simplified the complicated process of sample pretreatment and reduced sample treatment time. Recovery of the quinolones was between 92% - 101% for spiked honey samples. The limit of detection was 0.22 - 3.78 ng/mL (signal/noise ratio = 3). There was good linear correlation between HPLC peak area and concentration of the quinolones, with a linear range of 1.0 - 100.0 ng/mL and correlation coefficients >0.9997. The method proposed was validated for detecting quinolones in honey samples.
基金This work is financially supported by the Hunan 2011 Collaborative Innovation Center of Chemical Engineering&Technology with Environmental Benignity and Effective Resource UtilizationAdditional funding was provided by the Hunan Province Natural Science Fund(No.2020JJ4569 and 2023JJ60378)the Hunan Province College Students’Innovation and Entrepreneurship Training Program(No.S202110530044 and S202210530048).
文摘Traditional Chinese medicines(TCMs)possess a rich historical background,unique theoretical framework,remarkable therapeutic efficacy,and abundant resources.However,the modernization and internationalization of TCMs have faced significant obstacles due to their diverse ingredients and unknown mechanisms.To gain deeper insights into the phytochemicals and ensure the quality control of TCMs,there is an urgent need to enhance analytical techniques.Currently,two-dimensional(2D)chromatography,which incorporates two independent separation mechanisms,demonstrates superior separation capabilities compared to the traditional one-dimensional(1D)separation system when analyzing TCMs samples.Over the past decade,new techniques have been continuously developed to gain actionable insights from complex samples.This review presents the recent advancements in the application of multidimensional chromatography for the quality evaluation of TCMs,encompassing 2D-gas chromatography(GC),2D-liquid chromatography(LC),as well as emerging three-dimensional(3D)-GC,3D-LC,and their associated data-processing approaches.These studies highlight the promising potential of multidimensional chromatographic separation for future phytochemical analysis.Nevertheless,the increased separation capability has resulted in higher-order data sets and greater demands for data-processing tools.Considering that multidimensional chromatography is still a relatively nascent research field,further hardware enhancements and the implementation of chemometric methods are necessary to foster its robust development.