The development process of high-voltage electric power equipment maintenance was introduced. It is pointed out that the trend of high-voltage electric power equipment maintenance is so called condition-based maintenan...The development process of high-voltage electric power equipment maintenance was introduced. It is pointed out that the trend of high-voltage electric power equipment maintenance is so called condition-based maintenance. With the development of computer technology and sensors, on-line monitoring of high-voltage electric power equipment has developed rapidly. By introducing the main principle of Schering bridge to measure tanδ, the way of on-line monitoring of high-voltage electric power equipment was explained. Difference methods of on-line monitoring of insulation parameters for 35 kV substation were discussed. Finally, the shortcomings as well as its tendency of on-line monitoring were analyzed.展开更多
This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interf...This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.展开更多
文摘The development process of high-voltage electric power equipment maintenance was introduced. It is pointed out that the trend of high-voltage electric power equipment maintenance is so called condition-based maintenance. With the development of computer technology and sensors, on-line monitoring of high-voltage electric power equipment has developed rapidly. By introducing the main principle of Schering bridge to measure tanδ, the way of on-line monitoring of high-voltage electric power equipment was explained. Difference methods of on-line monitoring of insulation parameters for 35 kV substation were discussed. Finally, the shortcomings as well as its tendency of on-line monitoring were analyzed.
文摘This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.