Decreasing costs and favorable policies have resulted in increased penetration of solar photovoltaic(PV)power generation in distribution networks.As the PV systems penetration is likely to increase in the future,utili...Decreasing costs and favorable policies have resulted in increased penetration of solar photovoltaic(PV)power generation in distribution networks.As the PV systems penetration is likely to increase in the future,utilizing the reactive power capability of PV inverters to mitigate voltage deviations is being promoted.In recent years,droop control of inverter-based distributed energy resources has emerged as an essential tool for use in this study.The participation of PV systems in voltage regulation and its coordination with existing controllers,such as on-load tap changers,is paramount for controlling the voltage within specified limits.In this work,control strategies are presented that can be coordinated with the existing controls in a distributed manner.The effectiveness of the proposed method was demonstrated through simulation results on a distribution system.展开更多
At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this ...At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.展开更多
With the growing demand for precise voltage adjustment and reactive regulation,the frequent operation of on-load tap changers(OLTCs)in oil-immersed systems has led to increased erosion of switch contacts by arcs durin...With the growing demand for precise voltage adjustment and reactive regulation,the frequent operation of on-load tap changers(OLTCs)in oil-immersed systems has led to increased erosion of switch contacts by arcs during the switching process.This erosion causes significant wear on the contacts,thereby reducing their lifespan.Therefore,the present study aims to investigate the behavior and mechanism of arc erosion on contact surfaces in oil-immersed OLTCs.To achieve this,a self-designed friction and wear test device for OLTC contacts was utilized to conduct experiments at various sliding speeds and contact pressures.Additionally,finite element analysis was employed to validate the experimental results regarding the influence of sliding speed on arc energy.The surface morphology of the contacts was observed using an optical microscope.The findings revealed that as the sliding speed increased,the arc energy,arc initiation rate,and contact resistance initially exhibited an upward trend,then decreased,and eventually increased again.The minimum values were observed at a sliding speed of 90 mm/s.Moreover,the arc energy,arc initiation rate,and contact resistance decreased gradually as the contact pressure increased.After reaching a contact pressure of 1.5 N,the variation in the arc energy stabilized.At lower contact pressures,arc erosion dominated the wear on the contact surface.However,at higher contact pressures,the wear transitioned from predominantly arc erosion to a combination of mechanical wear and arc erosion.In summary,experimental and analytical investigations provided insights into the effects of sliding speed and contact pressure on the behavior of arc erosion,contact resistance,and surface damage of OLTC contacts in oil-immersed systems.展开更多
为进一步提高有载分接开关(on-load tap changer,OLTC)机械状态监测的准确性,文中基于优化品质因数可调小波变换(tunable quality wavelet transform,TQWT)对OLTC切换过程中的振动信号进行了分析。即使用人工鱼群算法(artificial fish s...为进一步提高有载分接开关(on-load tap changer,OLTC)机械状态监测的准确性,文中基于优化品质因数可调小波变换(tunable quality wavelet transform,TQWT)对OLTC切换过程中的振动信号进行了分析。即使用人工鱼群算法(artificial fish swarm algorithm,AFSA)基于分解余量与整体正交系数研究了TQWT的优化分解方法,计算得到了OLTC振动信号的多个子序列,构建了基于优化孪生支持向量机(twin support vector machine,TWSVM)的OLTC机械故障诊断模型。对某CM型OLTC正常与典型机械故障下振动信号的分析结果表明,所提优化TQWT分解方法有效提高了OLTC振动信号分解结果的准确性。相对于其他诊断模型,所构建AFSA-TWSVM的OLTC机械故障诊断模型分类效果好且收敛速度更快。展开更多
无励磁分接开关出现放电性故障会严重危害变压器安全运行。介绍了一起500 k V变压器交接试验过程中脉冲局部放电试验异常的案例,应用脉冲电流法、特高频法、超声波法等多维局部放电检测技术进行时差定位,成功诊断了变压器无励磁分接开...无励磁分接开关出现放电性故障会严重危害变压器安全运行。介绍了一起500 k V变压器交接试验过程中脉冲局部放电试验异常的案例,应用脉冲电流法、特高频法、超声波法等多维局部放电检测技术进行时差定位,成功诊断了变压器无励磁分接开关内部异物放电故障;通过材质成分分析判断异物为动触头旋转轴压环的机加工碎屑,异物位于无励磁分接开关动触头旋转轴位置,随挡位切换而移动,导致各个挡位均可检测到局部放电,且脉冲局部放电量随挡位变化而变化。展开更多
基金by a project under the scheme entitled“Developing Policies&Adaptation Strategies to Climate Change in the Baltic Sea Region”(ASTRA),Project No.ASTRA6-4(2014-2020.4.01.16-0032).
文摘Decreasing costs and favorable policies have resulted in increased penetration of solar photovoltaic(PV)power generation in distribution networks.As the PV systems penetration is likely to increase in the future,utilizing the reactive power capability of PV inverters to mitigate voltage deviations is being promoted.In recent years,droop control of inverter-based distributed energy resources has emerged as an essential tool for use in this study.The participation of PV systems in voltage regulation and its coordination with existing controllers,such as on-load tap changers,is paramount for controlling the voltage within specified limits.In this work,control strategies are presented that can be coordinated with the existing controls in a distributed manner.The effectiveness of the proposed method was demonstrated through simulation results on a distribution system.
文摘At present, an automatic-mechanic contact tap-changer is widely used in power system, but it can not frequently operate. In addition, arc will occur when the switch changes. In order to solve these two problems, this paper presented an automatic on-load voltage-regulating distributing transformer which employed non-contact solid-state relay as tap-changer, and mainly introduced its structure, basic principal, design method of each key link and experimental results. Laboratory simulation experiments informed that the scheme was feasible. It was a smooth and effective experiment device, which was practical in application.
文摘With the growing demand for precise voltage adjustment and reactive regulation,the frequent operation of on-load tap changers(OLTCs)in oil-immersed systems has led to increased erosion of switch contacts by arcs during the switching process.This erosion causes significant wear on the contacts,thereby reducing their lifespan.Therefore,the present study aims to investigate the behavior and mechanism of arc erosion on contact surfaces in oil-immersed OLTCs.To achieve this,a self-designed friction and wear test device for OLTC contacts was utilized to conduct experiments at various sliding speeds and contact pressures.Additionally,finite element analysis was employed to validate the experimental results regarding the influence of sliding speed on arc energy.The surface morphology of the contacts was observed using an optical microscope.The findings revealed that as the sliding speed increased,the arc energy,arc initiation rate,and contact resistance initially exhibited an upward trend,then decreased,and eventually increased again.The minimum values were observed at a sliding speed of 90 mm/s.Moreover,the arc energy,arc initiation rate,and contact resistance decreased gradually as the contact pressure increased.After reaching a contact pressure of 1.5 N,the variation in the arc energy stabilized.At lower contact pressures,arc erosion dominated the wear on the contact surface.However,at higher contact pressures,the wear transitioned from predominantly arc erosion to a combination of mechanical wear and arc erosion.In summary,experimental and analytical investigations provided insights into the effects of sliding speed and contact pressure on the behavior of arc erosion,contact resistance,and surface damage of OLTC contacts in oil-immersed systems.
文摘为进一步提高有载分接开关(on-load tap changer,OLTC)机械状态监测的准确性,文中基于优化品质因数可调小波变换(tunable quality wavelet transform,TQWT)对OLTC切换过程中的振动信号进行了分析。即使用人工鱼群算法(artificial fish swarm algorithm,AFSA)基于分解余量与整体正交系数研究了TQWT的优化分解方法,计算得到了OLTC振动信号的多个子序列,构建了基于优化孪生支持向量机(twin support vector machine,TWSVM)的OLTC机械故障诊断模型。对某CM型OLTC正常与典型机械故障下振动信号的分析结果表明,所提优化TQWT分解方法有效提高了OLTC振动信号分解结果的准确性。相对于其他诊断模型,所构建AFSA-TWSVM的OLTC机械故障诊断模型分类效果好且收敛速度更快。
文摘无励磁分接开关出现放电性故障会严重危害变压器安全运行。介绍了一起500 k V变压器交接试验过程中脉冲局部放电试验异常的案例,应用脉冲电流法、特高频法、超声波法等多维局部放电检测技术进行时差定位,成功诊断了变压器无励磁分接开关内部异物放电故障;通过材质成分分析判断异物为动触头旋转轴压环的机加工碎屑,异物位于无励磁分接开关动触头旋转轴位置,随挡位切换而移动,导致各个挡位均可检测到局部放电,且脉冲局部放电量随挡位变化而变化。