期刊文献+
共找到51篇文章
< 1 2 3 >
每页显示 20 50 100
Cross-calibration of brightness temperature obtained by FY-3B/MWRI using Aqua/AMSR-E data for snow depth retrieval in the Arctic 被引量:3
1
作者 Haihua Chen Lele Li Lei Guan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2021年第1期43-53,共11页
This study cross-calibrated the brightness temperatures observed in the Arctic by using the FY-3B/MWRI L1 and the Aqua/AMSR-E L2A.The monthly parameters of the cross-calibration were determined and evaluated using rob... This study cross-calibrated the brightness temperatures observed in the Arctic by using the FY-3B/MWRI L1 and the Aqua/AMSR-E L2A.The monthly parameters of the cross-calibration were determined and evaluated using robust linear regression.The snow depth in case of seasonal ice was calculated by using parameters of the crosscalibration of data from the MWRI Tb.The correlation coefficients of the H/V polarization among all channels Tb of the two sensors were higher than 0.97.The parameters of the monthly cross-calibration were useful for the snow depth retrieval using the MWRI.Data from the MWRI Tb were cross-calibrated to the AMSR-E baseline.Biases in the data of the two sensors were optimized to approximately 0 K through the cross-calibration,the standard deviations decreased significantly in the range of 1.32 K to 2.57 K,and the correlation coefficients were as high as 99%.An analysis of the statistical distributions of the histograms before and after cross-calibration indicated that the FY-3B/MWRI Tb data had been well calibrated.Furthermore,the results of the cross-calibration were evaluated by data on the daily average Tb at 18.7 GHz,23.8 GHz,and 36.5 GHz(V polarization),and at 89 GHz(H/V polarization),and were applied to the snow depths retrieval in the Arctic.The parameters of monthly cross-calibration were found to be effective in terms of correcting the daily average Tb.The results of the snow depths were compared with those of the calibrated MWRI and AMSR-E products.Biases of 0.18 cm to 0.38 cm were observed in the monthly snow depths,with the standard deviations ranging from 4.19 cm to 4.80 cm. 展开更多
关键词 FY-3B AMSR-E brightness temperature(T^(b)) cross-calibration snow depth ARCTIC
下载PDF
On-orbit Geometric Calibration and Preliminary Accuracy Evaluation of GF-14 Satellite
2
作者 Xueliang LU Jianrong WANG +4 位作者 Xiuce YANG Yuan LYU Yan HU Bincai CAO Junming ZHOU 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第2期62-70,共9页
GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Poi... GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Points(GCPs).In fact,space-based high-precision mapping without GCPs is a challenging task that depends on the close cooperation of several payloads and links,of which on-orbit geometric calibration is one of the most critical links.In this paper,the on-orbit geometric calibration of the dual-line array cameras of GF-14 satellite was performed using the control points collected in the high-precision digital calibration field,and the calibration parameters of the dual-line array cameras were solved as a whole by alternate iterations of forward and backward intersection.On this basis,the location accuracy of the stereo images using the calibration parameters was preliminarily evaluated by using several test fields around the world.The evaluation result shows that the direct forward intersection accuracy of GF-14 satellite images without GCPs after on-orbit geometric calibration reaches 2.34 meters(RMS)in plane and 1.97 meters(RMS)in elevation. 展开更多
关键词 GF-14 satellite high-precision digital calibration field on-orbit geometric calibration without ground control points accuracy evaluation
下载PDF
GYRO BIAS ON-ORBIT CALIBRATION FOR MICRO SATELLITES 被引量:1
3
作者 郁丰 刘建业 熊智 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2007年第4期300-304,共5页
According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements r... According to gyro application in micro-satellites, a new gyro bias real-time on-orbit calibration technology is presented and it is independent of any other sensors. The approach relies on gyro on-orbit measurements restricted by satellite attitude dynamics and estimates the gyro bias generated when the gyro is electrified. Observability of the calibration model is analyzed and applicable conditions of the technology are derived. Simulation results indicate that the calibration algorithm is accurate and robust at gyro sampling rate, and its convergence speed is fast. Within the given attitude dynamics model error, the convergence time is less than 100 s and the convergence accuracy is about 1.0 (°)/h. Calibration performance can meet requirements of spacecraft operations. 展开更多
关键词 on-orbit calibration gyro bias Kalman filter micro satellite
下载PDF
On-orbit sleep problems of astronauts and countermeasures 被引量:14
4
作者 Bin Wu Yue Wang +3 位作者 Xiaorui Wu Dong Liu Dong Xu Fei Wang 《Military Medical Research》 SCIE CAS 2018年第3期251-262,共12页
Sufficient sleep duration and good sleep quality are crucial to ensure normal physical and mental health, cognition and work performance for the common people, as well as astronauts. On-orbit sleep problem is very com... Sufficient sleep duration and good sleep quality are crucial to ensure normal physical and mental health, cognition and work performance for the common people, as well as astronauts. On-orbit sleep problem is very common among astronauts and has potential detrimental influences on the health of crewmembers and the safety of flight missions. Sleep in space is becoming a new medical research frontier. In this review we summarized on-orbit sleep problems of astronauts and six kinds of causes, and we presented the effects of lack of sleep on performance as well as mental and physical health, then we proposed seven kinds of countermeasures for sleep disturbance in spaceflight, including pharmacologic interventions, light treatment, crew selection and training, Traditional Chinese Medicine and so on. Furthermore, we discussed and oriented the prospect of researches on sleep in space. 展开更多
关键词 ASTRONAUT on-orbit Sleep Countermeasure Human SPACEFLIGHT
下载PDF
On-orbit target tracking and inspection by satellite formation 被引量:2
5
作者 Guang Zhai Jingrui Zhang Zhicheng Zhou 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2013年第6期879-888,共10页
A new type of estimator is developed for the satellite formation to track and inspect on-orbit targets. The follower satellite in the formation works without relative sensors, and its target pointing commands are deri... A new type of estimator is developed for the satellite formation to track and inspect on-orbit targets. The follower satellite in the formation works without relative sensors, and its target pointing commands are derived based on relative orbital dynamics. The centralized estimator based on truth measurement is designed, however, this estimator is proved unstable because of the lack of necessary measurement information. After that, an alternative estimator based on pseudo measurement is designed, and its observability and controllability are analyzed to qualitatively evaluate the convergence performance. Finally, an on-orbit target inspection scenario is numerically simulated to verify the performance of the estimator based on pseudo measurement. 展开更多
关键词 satellite formation on-orbit inspection target tracking pseudo measurement
下载PDF
On-orbit Geometric Calibration of Linear Push-broom Optical Satellite Based on Sparse GCPs 被引量:10
6
作者 Yingdong PI Baorong XIE +3 位作者 Bo YANG Yiling ZHANG Xin LI Mi WANG 《Journal of Geodesy and Geoinformation Science》 2020年第1期64-75,共12页
The paper presents a geometric calibration method based on the sparse ground control points (GCPs), aiming to the linear push-broom optical satellite. This method can achieve the optimal estimate of internal and exter... The paper presents a geometric calibration method based on the sparse ground control points (GCPs), aiming to the linear push-broom optical satellite. This method can achieve the optimal estimate of internal and external parameters with two overlapped image pair along the charge-coupled device (CCD), and sparse GCPs in the image region, further get rid of the dependence on the expensive calibration site data. With the calibrated parameters, the line of sight (LOS) of all CCD detectors can be recovered. This paper firstly establishes the rigorous imaging model of linear push-broom optical satellite based on its imaging mechanism. And then the calibration model is constructed by improving the internal sensor model with a viewing-angle model after an analysis on systematic errors existing in the imaging model is performed. A step-wise solution is applied aiming to the optimal estimate of external and internal parameters. At last, we conduct a set of experiments on the ZY-3 NAD camera and verify the accuracy and effectiveness of the presented method by comparison. 展开更多
关键词 OPTICAL SATELLITE on-orbit geometric calibration overlapped image pair SPARSE GCPs viewing-angle
下载PDF
GF-5 VIMI On-Orbit Calibration Instrument and Performance 被引量:1
7
作者 Hao Wang 《Journal of Computer and Communications》 2019年第7期293-300,共8页
The Visible and Infrared Multispectral Imager (VIMI) is one of the main payloads of the GF-5 satellite. It has 12 spectral bands covering the wavelength from visible light to thermal infrared. The imager designed life... The Visible and Infrared Multispectral Imager (VIMI) is one of the main payloads of the GF-5 satellite. It has 12 spectral bands covering the wavelength from visible light to thermal infrared. The imager designed life is 8 years. In order to monitor and correct the radiometric performance of the imager for a long time and meet the user’s demand for the quantitative remote sensing application, the expandable diffuser used for calibration in full FOV and full optical path method is designed. The solar diffuser is installed on the front side of the optical system and does not affect the normal imaging of VIMI. When VIMI need calibration, the diffuser is expand to the front of optical system via the driving mechanism. According to the characteristics of the GF-5 satellite orbit, the requirement of the calibration energy and the installation matrix of the imager relative to the satellite, the expansion angle of the diffuser is 39 degrees. The 430 mm × 430 mm large-size PTEE diffuser is manufactured to ensure full FOV and full optical path calibration. The diffuser’s directional hemispherical reflectance is higher than 95% from 420 nm to 2400 nm and variation of BRDF in the direction of imager observation is better than 2.5%. The diffuser stability monitoring radiometer is designed to monitor the on-orbit attenuation performance of the diffuser. Results of ground simulation experiments and preliminary on-board calibration experiments were introduced. 展开更多
关键词 on-orbit CALIBRATION SOLAR DIFFUSER Radiometric CALIBRATION GF-5 SATELLITE
下载PDF
Calibration chain design based on integrating sphere transfer radiometer for SI-traceable on-orbit spectral radiometric calibration and its uncertainty analysis 被引量:1
8
作者 赵维宁 方伟 +2 位作者 孙立微 崔立红 王玉鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期276-283,共8页
In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors,a transfer chain consisting of a fiber coupling monochromator(FBM)... In order to satisfy the requirement of SI-traceable on-orbit absolute radiation calibration transfer with high accuracy for satellite remote sensors,a transfer chain consisting of a fiber coupling monochromator(FBM) and an integrating sphere transfer radiometer(ISTR) was designed in this paper.Depending on the Sun,this chain based on detectors provides precise spectral radiometric calibration and measurement to spectrometers in the reflective solar band(RSB) covering 300–2500 nm with a spectral bandwidth of 0.5–6 nm.It shortens the traditional chain based on lamp source and reduces the calibration uncertainty from 5% to 0.5% by using the cryogenic radiometer in space as a radiometric benchmark and trap detectors as secondary standard.This paper also gives a detailed uncertainty budget with reasonable distribution of each impact factor,including the weak spectral signal measurement with uncertainty of 0.28%.According to the peculiar design and comprehensive uncertainty analysis,it illustrates that the spectral radiance measurement uncertainty of the ISTR system can reach to 0.48%.The result satisfies the requirements of SI-traceable on-orbit calibration and has wider significance for expanding the application of the remote sensing data with high-quality. 展开更多
关键词 SI-traceable calibration on-orbit high-accuracy transfer chain integrating sphere transfer radiometer uncertainty analysis
下载PDF
Multi-Feature Fusion Based Relative Pose Adaptive Estimation for On-Orbit Servicing of Non-Cooperative Spacecraft
9
作者 Yunhua Wu Nan Yang +1 位作者 Zhiming Chen Bing Hua 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第6期19-30,共12页
On-orbit servicing, such as spacecraft maintenance, on-orbit assembly, refueling, and de-orbiting, can reduce the cost of space missions, improve the performance of spacecraft, and extend its life span. The relative s... On-orbit servicing, such as spacecraft maintenance, on-orbit assembly, refueling, and de-orbiting, can reduce the cost of space missions, improve the performance of spacecraft, and extend its life span. The relative state between the servicing and target spacecraft is vital for on-orbit servicing missions, especially the final approaching stage. The major challenge of this stage is that the observed features of the target are incomplete or are constantly changing due to the short distance and limited Field of View (FOV) of camera. Different from cooperative spacecraft, non-cooperative target does not have artificial feature markers. Therefore, contour features, including triangle supports of solar array, docking ring, and corner points of the spacecraft body, are used as the measuring features. To overcome the drawback of FOV limitation and imaging ambiguity of the camera, a "selfie stick" structure and a self-calibration strategy were implemented, ensuring that part of the contour features could be observed precisely when the two spacecraft approached each other. The observed features were constantly changing as the relative distance shortened. It was difficult to build a unified measurement model for different types of features, including points, line segments, and circle. Therefore, dual quaternion was implemented to model the relative dynamics and measuring features. With the consideration of state uncertainty of the target, a fuzzy adaptive strong tracking filter( FASTF) combining fuzzy logic adaptive controller (FLAC) with strong tracking filter(STF) was designed to robustly estimate the relative states between the servicing spacecraft and the target. Finally, the effectiveness of the strategy was verified by mathematical simulation. The achievement of this research provides a theoretical and technical foundation for future on-orbit servicing missions. 展开更多
关键词 on-orbit servicing non-cooperative spacecraft multi-feature fusion fuzzy adaptive filter dual quaternion
下载PDF
A parallel pipeline connected-component labeling method for on-orbit space target monitoring
10
作者 LI Zongling ZHANG Qingjun +1 位作者 LONG Teng ZHAO Baojun 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2022年第5期1095-1107,共13页
The paper designs a peripheral maximum gray differ-ence(PMGD)image segmentation method,a connected-compo-nent labeling(CCL)algorithm based on dynamic run length(DRL),and a real-time implementation streaming processor ... The paper designs a peripheral maximum gray differ-ence(PMGD)image segmentation method,a connected-compo-nent labeling(CCL)algorithm based on dynamic run length(DRL),and a real-time implementation streaming processor for DRL-CCL.And it verifies the function and performance in space target monitoring scene by the carrying experiment of Tianzhou-3 cargo spacecraft(TZ-3).The PMGD image segmentation method can segment the image into highly discrete and simple point tar-gets quickly,which reduces the generation of equivalences greatly and improves the real-time performance for DRL-CCL.Through parallel pipeline design,the storage of the streaming processor is optimized by 55%with no need for external me-mory,the logic is optimized by 60%,and the energy efficiency ratio is 12 times than that of the graphics processing unit,62 times than that of the digital signal proccessing,and 147 times than that of personal computers.Analyzing the results of 8756 images completed on-orbit,the speed is up to 5.88 FPS and the target detection rate is 100%.Our algorithm and implementation method meet the requirements of lightweight,high real-time,strong robustness,full-time,and stable operation in space irradia-tion environment. 展开更多
关键词 Tianzhou-3 cargo spacecraft(TZ-3) connected-component labeling(CCL)algorithms parallel pipeline processing on-orbit space target detection streaming processor
下载PDF
Overview of Key Technologies and On-orbit Verification of China Space Station
11
作者 ZHANG Hao ZHU Guangchen 《Aerospace China》 2022年第1期3-11,共9页
Tiangong space station is a space station independently designed and developed by China.In order to build and operate the space station,it was necessary to make breakthroughs in many fields and master several key tech... Tiangong space station is a space station independently designed and developed by China.In order to build and operate the space station,it was necessary to make breakthroughs in many fields and master several key technologies,which were characterized over a long technological span and underwent difficult verifications.Therefore,in addition to ground verification,on-orbit flight tests of key technologies for the assembly,construction and operation of the space station were planned to be conducted used by the core module,taking into account the differences in the gravity environment between space and the Earth,in order to lay a foundation for the subsequent comprehensive assembly,construction and long-term on-orbit operation of the space station.In this paper,the mission characteristics of the space station are briefly introduced,along with the key technologies for the assembly and construction of the space station,and then the on-orbit verification tests are comprehensively introduced. 展开更多
关键词 key technologies on-orbit verification China Space Station
下载PDF
Space truss construction modeling based on on-orbit assembly motion feature 被引量:1
12
作者 Changjie ZHAO Weizhong GUO +3 位作者 Meng CHEN Jiaxing HU Youcheng HAN Rongfu LIN 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2024年第3期365-379,共15页
More space truss construction has been planned to develop and utilize space resources.These trusses are designed in the way of large-scale,complex,modular,and on-orbit assembly.To meet the upcoming challenge of large-... More space truss construction has been planned to develop and utilize space resources.These trusses are designed in the way of large-scale,complex,modular,and on-orbit assembly.To meet the upcoming challenge of large-scale space infrastructure construction,it is necessary to study space truss automation design and robotic construction.This paper proposes an ordinal finite screw adjacency matrix model(OFSAMM),focusing on the relationship between assembly motions,to express and compute a space truss structure.In this model,a space truss is abstracted as a set of ordered assembly motions,each of which is recorded as a finite screw as the basic element of the truss and its assembly.The operation of truss transformation is also derived under this model.Therefore,the truss configuration,the assembly sequence,the truss sub-assembly,the truss components,and the on-orbit assembly task can be expressed and calculated in a unified model,which is calculated and stores the truss topology and assembly with the minimum storage cost.At the end of this paper,we introduce how to synthesize and optimize space truss design through two cases.The study will help to improve design efficiency.Furthermore,it provides a theoretical basis for the automatic construction of space truss structures,especially in the next stage. 展开更多
关键词 Adjacency matrix Finite screw on-orbit construction modeling Space applications Space trusses Topology design
原文传递
A Shape-Memory Deployable Subsystem with a Large Folding Ratio in China’s Tianwen-1 Mars Exploration Mission
13
作者 Chengjun Zeng Liwu Liu +14 位作者 Yang Du Miao Yu Xiaozhou Xin Tianzhen Liu Peilei Xu Yu Yan Dou Zhang Wenxu Dai Xin Lan Fenghua Zhang Linlin Wang Xue Wan Wenfeng Bian Yanju Liu Jinsong Leng 《Engineering》 SCIE EI CAS CSCD 2023年第9期49-57,共9页
Once China’s Tianwen-1 Mars probe arrived in a Mars orbit after a seven-month flight in the deep cold space environment,it would be urgently necessary to monitor its state and the surrounding environment.To address t... Once China’s Tianwen-1 Mars probe arrived in a Mars orbit after a seven-month flight in the deep cold space environment,it would be urgently necessary to monitor its state and the surrounding environment.To address this issue,we developed a flexible deployable subsystem based on shape memory polymer composites(SMPC-FDS)with a large folding ratio,which incorporates a camera and two temperature telemetry points for monitoring the local state of the Mars orbiter and the deep space environment.Here,we report on the development,testing,and successful application of the SMPC-FDS.Before reaching its Mars remote-sensing orbit,the SMPC-FDS is designed to be in a folded state with high stiffness;after reaching orbit,it is in a deployed state with a large envelope.The transition from the folded state to the deployed state is achieved by electrically heating the shape memory polymer composites(SMPCs);during this process,the camera on the SMPC-FDS can capture the local state of the orbiter from multiple angles.Moreover,temperature telemetry points on the SMPC-FDS provide feedback on the environment temperature and the temperature change of the SMPCs during the energization process.By simulating a Mars on-orbit space environment,the engineering reliability of the SMPC-FDS was comprehensively verified in terms of the material properties,structural dynamic performance,and thermal vacuum deployment feasibility.Since the launch of Tianwen-1 on 23 July 2020,scientific data on the temperature environment around Tianwen-1 has been successfully acquired from the telemetry points on the SMPCFDS,and the local state of the orbiter has been photographed in orbit,showing the national flag of China fixed on the orbiter. 展开更多
关键词 Flexible deployable structure Shape memory polymer composite Mars exploration Temperature telemetry on-orbit deployment
下载PDF
A New Generation of Intelligent Mapping and Remote Sensing Scientific Test Satellite Luojia-301
14
作者 Deren LI Mi WANG Fang YANG 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第2期11-20,共10页
With the continuous improvement of the performance and the increasing variety of optical mapping and remote sensing satellites,they have become an important support for obtaining global accurate surveying and mapping ... With the continuous improvement of the performance and the increasing variety of optical mapping and remote sensing satellites,they have become an important support for obtaining global accurate surveying and mapping remote sensing information.At present,optical mapping and remote sensing satellites already have sub-meter spatial resolution capabilities,but there is a serious lag problem in mapping and remote sensing information services.It is urgent to develop intelligent mapping and remote sensing satellites to promote the transformation and upgrading to real-time intelligent services.Firstly,based on the three imaging systems of the optical mapping and remote sensing satellites and their realization methods and application characteristics,this paper analyzes the applicable system of the intelligent mapping and remote sensing satellites.Further,according to the application requirements of real-time,intelligence,and popularization,puts forward the design concept of integrated intelligent remote sensing satellite integrating communication,navigation,and remote sensing and focuses on the service mode and integrated function composition of intelligent remote sensing satellite.Then expounds on the performance and characteristics of the Luojia-301 satellite,a new generation of intelligent surveying and mapping remote sensing scientific test satellite.And finally summarizes and prospects the development and mission of intelligent mapping remote sensing satellites.Luojia-301 satellite integrates remote sensing and communication functions.It explores an efficient and intelligent service mode of mapping and remote sensing information from data acquisition to the application terminal and provides a real service verification platform for on-orbit processing and real-time transmission of remote sensing data based on space-ground internet,which is of great significance to the construction of China’s spatial information network. 展开更多
关键词 real-time intelligent services collaborative application on-orbit processing mapping and remote sensing information Luojia-301 satellite
下载PDF
An introductory review of swarm technology for spacecraft on-orbit servicing
15
作者 El Ghali Asri Zheng H.Zhu 《International Journal of Mechanical System Dynamics》 EI 2024年第1期3-21,共19页
This review paper presents a comprehensive evaluation and forward-looking perspective on the underexplored topic of servicing target objects using spacecraft swarms.Such targets can be known or unknown,cooperative or ... This review paper presents a comprehensive evaluation and forward-looking perspective on the underexplored topic of servicing target objects using spacecraft swarms.Such targets can be known or unknown,cooperative or uncooperative,and pose significant challenges in modern space operations due to their inherent complexity and unpredictability.Successfully servicing space objects is vital for active debris removal and broader on-orbit servicing tasks such as satellite maintenance,repair,refueling,orbital assembly,and construction.Significant effort has been invested in the literature to explore the servicing of targets using a single spacecraft.Given its advantages and benefits,this paper expands the discussion to encompass a swarm approach to the problem.This review covers various single-spacecraft approaches and presents a critical examination of the existing,although limited,body of work dedicated to servicing orbital objects using multiple spacecraft.The focus is also broadened to include some influential studies concerning the characterization,capture,and manipulation of physical objects by general multiagent systems,a subject with significant parallels to the core interest of this manuscript.Furthermore,this article also delves into the realm of simultaneous localization and mapping,highlighting its application within close-proximity operations in space,especially when dealing with unknown uncooperative targets.Special attention is paid to the benefits that this field can receive from distributed multiagent architectures.Finally,an exploration of the promising field of swarm robotics is presented,with an emphasis on its potential to revolutionize the servicing of orbital target objects.Concurrently,a survey of general research directly engaging swarms in the orbital context is conducted.This review aims to bridge the knowledge gap and stimulate further research in the underexplored domain of servicing space targets with spacecraft swarms. 展开更多
关键词 space robotics on-orbit servicing close-proximity operations guidance and navigation swarm robotics multiagent systems object capture and manipulation simultaneous localization and mapping
原文传递
Radiometric cross-calibration of the CBERS-02 CCD camera with the TERRA MODIS 被引量:15
16
作者 LI Xiaoying1,2,3, GU Xingfa1,3,4, MIN Xiangjun5, YU Tao1,3, FU Qiaoyan5, ZHANG Yong1,2,3 & LI Xiaowen1,3 1. State Key Laboratory of Remote Sensing Science, Jointly Sponsored by the Institute of Remote Sensing Applications of Chinese Academy of Sciences and Beijing Normal University, Beijing 100101, China 2. Graduate University of Chinese Academy of Sciences, Beijing 100039, China +2 位作者 3. The Center for National Spaceborne Demonstration, Beijing 100101, China 4. Institut National de la Recherche Agronomique, Climat Sol Environnement, 84914 Avignon, France 5. China Center for Resource Satellite Data and Application, Beijing 100830, China 《Science China(Technological Sciences)》 SCIE EI CAS 2005年第S2期44-60,共17页
For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful... For the application of the CCD camera, the most important payload on CBERS-02, the key is to provide long-term stable radiometric calibration coefficients. Although the vicarious calibration had been proved successful, it had its limitations such as test site requirement and unsuitable for historical data. Cross-calibration is one of the alternative methods, but it needs synchro surface spectrum to achieve spectral band matching factors. Our effort is to probe the influences on these factors. Simulations with a lot of surface spectrum showed that the factors changed with the viewing geometry, atmospheric condition and surface targets. However, simulating with the same viewing geometry and atmospheric condition, the spectral band matching factors of the same or similar surface targets’ spectrum acquired from different dates and different places would like to be consistent to each other within 1%―5%. Thus, the synchro measurement data can be substituted by the same or similar target from other source. Based on this method, using the MODIS as the reference, the cross-calibration was performed for CCD camera. The research demonstrated that the traditional method with single calibration site was inappropriate for CCD camera, since the offsets for its four spectral bands were not zeros. With four calibration sites, these offsets were obtained. And the camera was detected to degrade with dates based on four times of cross-calibrations. 展开更多
关键词 CBERS-02 CCD camera cross-calibration the spectral BAND MATCHING factors.
原文传递
The improvement of cross-calibration of IIM data and band selection for FeO inversion 被引量:4
17
作者 WANG Chao WU YunZhao +1 位作者 SHI RunHe GAO Wei 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2013年第11期2216-2225,共10页
Chang’E-1(CE-1)Interference Imaging Spectrometer(IIM)dataset suffers from the weak response in the near infrared(NIR)bands,which are the important wavelength for retrieving the minerals and elements of the Moon.In th... Chang’E-1(CE-1)Interference Imaging Spectrometer(IIM)dataset suffers from the weak response in the near infrared(NIR)bands,which are the important wavelength for retrieving the minerals and elements of the Moon.In this paper,the cross-calibration was implemented to the IIM hyperspectral data for improving the weak response in NIR bands.The results show that the cross-calibrated IIM spectra were consistent to the Earth-based telescopic spectra,which suggests that the cross-calibration yields acceptable results.For further validating the influence of the cross-calibration on the FeO inversion and searching the optimal bands to retrieve lunar FeO contents,four band selection schemes were designed to retrieve FeO using the original and cross-calibrated IIM spectra.By comparing the distribution patterns and histograms of the IIM derived FeO contents with the Clementine derived FeO,the IIM 891 nm band after cross-calibration showed a higher accuracy in the FeO inversion,hence most useful for lunar FeO inversion. 展开更多
关键词 IIM cross-calibration band selection FEO MOON
原文传递
Cross-calibration of high energetic particles data——A case study between FY-3B and NOAA-17 被引量:4
18
作者 WANG ChunQin ZHANG XianGuo +10 位作者 LI JiaWei HUANG Cong ZHANG XiaoXin JING Tao SHEN GuoHong ZHANG ShenYi CAO GuangWei SUN YueQiang LIANG JinBao ZHU GuangWu HAN Ying 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第11期2668-2674,共7页
Cross-calibration of high energetic particle data is a primary requirement for the availability of multi-instrument, multi-spacecraft data. II also can provide a method to verify relative reliability of data from sing... Cross-calibration of high energetic particle data is a primary requirement for the availability of multi-instrument, multi-spacecraft data. II also can provide a method to verify relative reliability of data from single satellite measurement. This pa- per presents a case study of energetic particles data cross-calibration between FY-3B and NOAA-17. A generally good agree- ment is acquired in the flux values and distribution trend of 2.5-6.9 MeV protons and 0.3-1.1 MeV electrons between FY-3B and NOAA-17 satellites. It suggests that the data observed by FY-3B is properly cross-calibrated. We can also confirm that energetic particles data observed by FY-3B satellite is available. 展开更多
关键词 cross-calibration high energetic particle FY-3B
原文传递
A twin-channel difference model for cross-calibration of thermal infrared band 被引量:2
19
作者 LI JiaGuo GU XingFa +4 位作者 YU Tao LI XiaoYing GAO HaiLiang LIU Li XU Hui 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第7期2048-2056,共9页
Based on the conduction and transformation of the thermal infrared radiative transfer equation of water target,a twinchannel difference model(DM) was proposed to improve the calibration precision by conquering the lim... Based on the conduction and transformation of the thermal infrared radiative transfer equation of water target,a twinchannel difference model(DM) was proposed to improve the calibration precision by conquering the limitation that the atmospheric condition when image is acquiring cannot be truly obtained in the traditional radiometric simulation calibration method.The analysis of surface,atmosphere and top-of-atmosphere(TOA) radiative energy decomposition demonstrated that the apparent TOA radiance of the uncalibrated channel is the differential combination of two reference channels.The DM avoids impacts from atmospheric temperature and density.The only impact is from water vapor(WV) content.Based on the fitting error analysis of 742 mid-latitude atmospheric profiles(column WV content:0-5×10 3 atm cm) selected from TIGR database,the DM is insensitive to WV content.The maximum error is less than 0.2 K when the view zenith angels(VZAs) of reference channels and uncalibrated channel are less than 30.The error becomes 0.3 K when VZAs range from 30 to 40 and 0.6 K when VZAs are in 40-50.Because the uncertainty increases when VZAs are larger than 50,the best range of VZAs is 30-50.The vicarious calibration results at Lake Qinghai field indicated that the calibration precision of the DM cross-calibration by using MODIS bands 31 and 32 as reference channels to calibrate IRS band 08 is similar to that of vicarious calibration.Therefore,the DM is a reliable alternative tool for sensor on-orbit calibration and validation with high precision and frequency. 展开更多
关键词 remote sensing cross-calibration difference model IRS MODIS
原文传递
Reactionless robust finite-time control for manipulation of passive objects by free-floating space robots 被引量:2
20
作者 郭胜鹏 李东旭 +1 位作者 孟云鹤 范才智 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第5期347-354,共8页
On-orbit servicing requires efficient techniques for manipulating passive objects. The paper aims at developing a reactionless control method that drives the manipulator to manipulate passive objects with high precisi... On-orbit servicing requires efficient techniques for manipulating passive objects. The paper aims at developing a reactionless control method that drives the manipulator to manipulate passive objects with high precision, while inducing no disturbances to its base attitude. To this end, decomposition of the target dynamics from the base dynamics is discussed, so that they can be considered as two independent subsystems. A reactionless nonlinear controller is presented, which ensures high-precision manipulation of the targets and that the base orientation is unchanged. This is achieved by combining the robust finite-time control with the reaction null space. Finally, the performance of the proposed method is examined by comparing it with that of a reactionless PD controller and a pure finite-time controller. 展开更多
关键词 reactionless motion robust finite-time control on-orbit manipulation
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部