期刊文献+
共找到28篇文章
< 1 2 >
每页显示 20 50 100
On-orbit Geometric Calibration and Preliminary Accuracy Evaluation of GF-14 Satellite
1
作者 Xueliang LU Jianrong WANG +4 位作者 Xiuce YANG Yuan LYU Yan HU Bincai CAO Junming ZHOU 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第2期62-70,共9页
GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Poi... GF-14 satellite is a new generation of sub-meter stereo surveying and mapping satellite in China,carrying dual-line array stereo mapping cameras to achieve 1∶10000 scale topographic mapping without Ground Control Points(GCPs).In fact,space-based high-precision mapping without GCPs is a challenging task that depends on the close cooperation of several payloads and links,of which on-orbit geometric calibration is one of the most critical links.In this paper,the on-orbit geometric calibration of the dual-line array cameras of GF-14 satellite was performed using the control points collected in the high-precision digital calibration field,and the calibration parameters of the dual-line array cameras were solved as a whole by alternate iterations of forward and backward intersection.On this basis,the location accuracy of the stereo images using the calibration parameters was preliminarily evaluated by using several test fields around the world.The evaluation result shows that the direct forward intersection accuracy of GF-14 satellite images without GCPs after on-orbit geometric calibration reaches 2.34 meters(RMS)in plane and 1.97 meters(RMS)in elevation. 展开更多
关键词 GF-14 satellite high-precision digital calibration field on-orbit geometric calibration without ground control points accuracy evaluation
下载PDF
On-orbit Geometric Calibration of Linear Push-broom Optical Satellite Based on Sparse GCPs 被引量:8
2
作者 Yingdong PI Baorong XIE +3 位作者 Bo YANG Yiling ZHANG Xin LI Mi WANG 《Journal of Geodesy and Geoinformation Science》 2020年第1期64-75,共12页
The paper presents a geometric calibration method based on the sparse ground control points (GCPs), aiming to the linear push-broom optical satellite. This method can achieve the optimal estimate of internal and exter... The paper presents a geometric calibration method based on the sparse ground control points (GCPs), aiming to the linear push-broom optical satellite. This method can achieve the optimal estimate of internal and external parameters with two overlapped image pair along the charge-coupled device (CCD), and sparse GCPs in the image region, further get rid of the dependence on the expensive calibration site data. With the calibrated parameters, the line of sight (LOS) of all CCD detectors can be recovered. This paper firstly establishes the rigorous imaging model of linear push-broom optical satellite based on its imaging mechanism. And then the calibration model is constructed by improving the internal sensor model with a viewing-angle model after an analysis on systematic errors existing in the imaging model is performed. A step-wise solution is applied aiming to the optimal estimate of external and internal parameters. At last, we conduct a set of experiments on the ZY-3 NAD camera and verify the accuracy and effectiveness of the presented method by comparison. 展开更多
关键词 OPTICAL SATELLITE on-orbit geometric calibration overlapped image pair SPARSE GCPs viewing-angle
下载PDF
GF-5 VIMI On-Orbit Calibration Instrument and Performance
3
作者 Hao Wang 《Journal of Computer and Communications》 2019年第7期293-300,共8页
The Visible and Infrared Multispectral Imager (VIMI) is one of the main payloads of the GF-5 satellite. It has 12 spectral bands covering the wavelength from visible light to thermal infrared. The imager designed life... The Visible and Infrared Multispectral Imager (VIMI) is one of the main payloads of the GF-5 satellite. It has 12 spectral bands covering the wavelength from visible light to thermal infrared. The imager designed life is 8 years. In order to monitor and correct the radiometric performance of the imager for a long time and meet the user’s demand for the quantitative remote sensing application, the expandable diffuser used for calibration in full FOV and full optical path method is designed. The solar diffuser is installed on the front side of the optical system and does not affect the normal imaging of VIMI. When VIMI need calibration, the diffuser is expand to the front of optical system via the driving mechanism. According to the characteristics of the GF-5 satellite orbit, the requirement of the calibration energy and the installation matrix of the imager relative to the satellite, the expansion angle of the diffuser is 39 degrees. The 430 mm × 430 mm large-size PTEE diffuser is manufactured to ensure full FOV and full optical path calibration. The diffuser’s directional hemispherical reflectance is higher than 95% from 420 nm to 2400 nm and variation of BRDF in the direction of imager observation is better than 2.5%. The diffuser stability monitoring radiometer is designed to monitor the on-orbit attenuation performance of the diffuser. Results of ground simulation experiments and preliminary on-board calibration experiments were introduced. 展开更多
关键词 on-orbit calibration SOLAR DIFFUSER Radiometric calibration GF-5 SATELLITE
下载PDF
Calibration Method of Magnetometer Based on BP Neural Network
4
作者 Yanke Wang Tao Sheng +1 位作者 Liang He Zhaoyang Cheng 《Journal of Computer and Communications》 2020年第6期31-41,共11页
<div style="text-align:justify;"> Due to the influence of processing technology and environmental factors, there are errors in attitude measurement with the three-axis magnetometer, and the change of p... <div style="text-align:justify;"> Due to the influence of processing technology and environmental factors, there are errors in attitude measurement with the three-axis magnetometer, and the change of parameters during the operation of the magnetometer in orbit will have a great impact on the measurement accuracy. This paper studies the calibration method of magnetometer based on BP neural network, which reduces the influence of model error on calibration accuracy. Firstly, the error model of the magnetometer and the structural characteristics of the BP neural network are analyzed. Secondly, the number of hidden layers and hidden nodes is optimized. To avoid the problem of slow convergence and low accuracy of basic BP algorithm, this paper uses the Levenberg Marquardt backpropagation training method to improve the training speed and prediction accuracy and realizes the on-orbit calibration of magnetometer through online training of the neural network. Finally, the effectiveness of the method is verified by numerical simulation. The results show that the neural network designed in this paper can effectively reduce the measurement error of magnetometer, while the online training can effectively reduce the error caused by the change of magnetometer parameters, and reduce the measurement error of magnetometer to less than 10 nT. </div> 展开更多
关键词 Magnetometer calibration Neural Network Levenberg-Marquardt Method on-orbit Training
下载PDF
嵩山遥感定标场靶标反射率的自动测量方法
5
作者 潘琰 李新(指导) +2 位作者 李照洲 张权 张艳娜 《大气与环境光学学报》 CAS CSCD 2023年第2期141-152,共12页
利用自主研制的地表反射自动监测光谱仪(ARMS)和可见-短波红外光谱辐照度计(HIM),实现了嵩山遥感定标场内三种灰阶靶标反射率的自动测量,并与使用ASD便携式光谱仪人工测量的靶标反射率开展了比对。两种方法的比对结果表明:在400~1600 n... 利用自主研制的地表反射自动监测光谱仪(ARMS)和可见-短波红外光谱辐照度计(HIM),实现了嵩山遥感定标场内三种灰阶靶标反射率的自动测量,并与使用ASD便携式光谱仪人工测量的靶标反射率开展了比对。两种方法的比对结果表明:在400~1600 nm范围内,自动化测量与人工测量的反射率数据在非大气吸收波段的相对偏差优于±2%。进一步基于自动化设备的观测数据,分析了2019年10月至2020年11月场地内的靶标反射率。分析结果表明,受环境变化的影响,嵩山场内灰阶靶标的反射率也会发生变化,且反射率的变化趋势与波长范围及测量区域有关。在整个波段范围内,反射率的标准偏差在±2.5%以内。该工作的开展为基于嵩山遥感定标场的自动化、高频次在轨辐射定标提供了有力的技术支撑。 展开更多
关键词 嵩山定标场 在轨替代定标 灰阶靶标 光谱反射率
下载PDF
A review of structures,verification,and calibration technologies of space robotic systems for on-orbit servicing 被引量:15
6
作者 DING XiLun WANG YeCong +1 位作者 WANG YaoBing XU Kun 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2021年第3期462-480,共19页
Recently,with the rapid development of aerospace technology,an increasing number of spacecraft is being launched into space.Additionally,the demands for on-orbit servicing(OOS)missions are rapidly increasing.Space rob... Recently,with the rapid development of aerospace technology,an increasing number of spacecraft is being launched into space.Additionally,the demands for on-orbit servicing(OOS)missions are rapidly increasing.Space robotics is one of the most promising approaches for various OOS missions;thus,research on space robotics technologies for OOS has attracted increased attention from space agencies and universities worldwide.In this paper,we review the structures,ground verification,and onorbit kinematics calibration technologies of space robotic systems for OOS.First,we systematically summarize the development of space robotic systems and OOS programs based on space robotics.Then,according to the structures and applications,these systems are divided into three categories:large space manipulators,humanoid space robots,and small space manipulators.According to the capture mechanisms adopted,the end-effectors are systematically analyzed.Furthermore,the ground verification facilities used to simulate a microgravity environment are summarized and compared.Additionally,the on-orbit kinematics calibration technologies are discussed and analyzed compared with the kinematics calibration technologies of industrial manipulators with regard to four aspects.Finally,the development trends of the structures,verification,and calibration technologies are discussed to extend this review work. 展开更多
关键词 space robotic system on-orbit servicing large space manipulator humanoid space robot VERIFICATION kinematics calibration
原文传递
星载光学遥感器可见近红外通道辐射定标研究进展 被引量:52
7
作者 高海亮 顾行发 +3 位作者 余涛 李小英 巩慧 李家国 《遥感信息》 CSCD 2010年第4期117-128,共12页
辐射定标是遥感定量化应用的基础。在阐述辐射定标概念,意义和方法的基础上,介绍了发射前定标、在轨星上定标和在轨替代定标的各种方法,并分析了这些方法在卫星不同阶段所起的作用。以在轨替代定标中的场地定标法、场景定标法和交叉定... 辐射定标是遥感定量化应用的基础。在阐述辐射定标概念,意义和方法的基础上,介绍了发射前定标、在轨星上定标和在轨替代定标的各种方法,并分析了这些方法在卫星不同阶段所起的作用。以在轨替代定标中的场地定标法、场景定标法和交叉定标法为重点,详细介绍了其中各种方法的基本原理,适用范围以及当前国内外研究现状。最后,对当前国际上辐射定标的发展趋势作出展望,并针对国内的辐射定标现状提出相关的建议,使用户能够得到更高精度的遥感数据。 展开更多
关键词 辐射定标 替代定标 场地定标 场景定标 交叉定标
下载PDF
利用青海湖水面辐射校正场对FY-1C气象卫星热红外传感器进行绝对辐射定标 被引量:12
8
作者 胡秀清 戎志国 +3 位作者 邱康睦 张玉香 张广顺 黄意玢 《遥感学报》 EI CSCD 北大核心 2002年第5期328-333,T001,共7页
利用青海湖水面场FY 1C气象卫星热红外窗区通道进行绝对辐射定标 ,由CE312野外热红外辐射计在水面测得辐亮度经大气订正传递到卫星入瞳处 ,考虑到大气吸收削弱影响 ,同时卫星观测路径大气产生热发射 ,这两部分对卫星信号的贡献由探空... 利用青海湖水面场FY 1C气象卫星热红外窗区通道进行绝对辐射定标 ,由CE312野外热红外辐射计在水面测得辐亮度经大气订正传递到卫星入瞳处 ,考虑到大气吸收削弱影响 ,同时卫星观测路径大气产生热发射 ,这两部分对卫星信号的贡献由探空廓线和卫星观测几何输入MODTRAN37计算出来。同时进行CE312野外辐射计与卫星通道光谱响应匹配计算 ,最终得到卫星入瞳处的表观辐亮度。这个辐亮度与卫星通道的计数值比较得到该通道绝对定标系数。结果表明利用辐射校正场辐射定标与星上定标相差 5 %左右 ,相当于 3K的亮温差。 展开更多
关键词 青海湖 水面辐射校正场 气象卫星 热红外传感器 绝对辐射定标 替代定标 光谱响应匹配 辐射传输计算 入瞳处辐亮度
下载PDF
基于敦煌场地定标的FY-3MERSI反射太阳波段在轨响应变化分析 被引量:29
9
作者 孙凌 郭茂华 +6 位作者 徐娜 张立军 刘京晶 胡秀清 李元 戎志国 赵泽会 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2012年第7期1869-1877,共9页
鉴于中分辨率光谱成像仪不能实现反射太阳波段的星上绝对辐射定标,提出了基于地表方向模型、矢量辐射传输模型6SV并联合MODTRAN吸收透过率校正的敦煌场替代定标新方法,4年的同步定标结果表明,除了水汽吸收中心波段之外,定标不确定度小于... 鉴于中分辨率光谱成像仪不能实现反射太阳波段的星上绝对辐射定标,提出了基于地表方向模型、矢量辐射传输模型6SV并联合MODTRAN吸收透过率校正的敦煌场替代定标新方法,4年的同步定标结果表明,除了水汽吸收中心波段之外,定标不确定度小于5%,而多数波段优于3%。以Aqua MODIS为辐射基准的大气顶辐射计算试验表明,正演与卫星观测间的平均偏差在波长<1μm的窗区波段小于3%,波长>1μm的小于5%(除了2.1μm波段);此外,经场地定标的MERSI表观反射率与MODIS具有很好的一致性。基于多年的场地定标结果发现:可采用二次多项式拟合定标系数的时间变化,进而实现逐天的定标更新;波长<0.6μm的波段衰变较大,波段8(0.41μm)入轨第一年的衰变率约为14%;在轨初期衰变最大,一年后趋缓,两年后部分波长>0.6μm的波段出现响应增加现象。 展开更多
关键词 风云3号 中分辨率光谱成像仪 反射太阳波段 在轨响应变化 场地替代定标
下载PDF
卫星光学仪器辐射交互定标方法的应用和发展 被引量:7
10
作者 赵维宁 胡秀清 +2 位作者 方伟 王玉鹏 徐娜 《光学精密工程》 EI CAS CSCD 北大核心 2015年第7期1921-1931,共11页
卫星遥感器的在轨交互定标是保证仪器数据记录的可靠性、连续性和一致性的核心方案,配合高精度的在轨参考基准仪器可使定标精度达到2%左右。本文介绍了交互定标技术的相关概念和意义,强调该技术是修正仪器间辐射定标相对偏差的重要手段... 卫星遥感器的在轨交互定标是保证仪器数据记录的可靠性、连续性和一致性的核心方案,配合高精度的在轨参考基准仪器可使定标精度达到2%左右。本文介绍了交互定标技术的相关概念和意义,强调该技术是修正仪器间辐射定标相对偏差的重要手段。指出了交互定标的前提条件及现存难点。总结了交互定标实现流程,包括数据收集、匹配、筛选、处理,基准确定,精度分析等,分析了影响交互定标精度的各种因素。叙述了当前卫星光学遥感器交互定标的各类方法及其使用条件,总结了不同应用条件下所适用的各交互定标方法的定标精度。最后结合当前交互定标的国际合作活动,分析展望了未来光学遥感器在轨可溯源SI定标方法的前景趋势和难点问题。 展开更多
关键词 星载光学仪器交互定标 地球观测系统 替代定标 国际合作 溯源性 精确度
下载PDF
神舟四号飞船微波辐射计定标和检验(Ⅰ)——微波辐射计外定标 被引量:17
11
作者 王振占 李芸 《遥感学报》 EI CSCD 北大核心 2004年第5期397-403,共7页
文中针对神舟四号飞船辐射计 (RAD)的在轨定标特点 ,提出一种替代外定标方案 ,即利用地球表面典型地物的微波辐射对RAD的不同通道重新进行定标。选取了全球大洋开阔海域的浮标、星载微波辐射计产品和小岛上气象探空数据 ,通过理论计算... 文中针对神舟四号飞船辐射计 (RAD)的在轨定标特点 ,提出一种替代外定标方案 ,即利用地球表面典型地物的微波辐射对RAD的不同通道重新进行定标。选取了全球大洋开阔海域的浮标、星载微波辐射计产品和小岛上气象探空数据 ,通过理论计算得出的亮温作为辐射计测量的低端。利用南美洲热带雨林亮温作为高端 ,重新给出了RAD定标方程。同时 ,为了确定定标的效果 ,分别与国外星载微波辐射计相同或相近通道的亮温进行了比较。另外还结合南海地面配合试验的测量结果对辐射计定标数据进行了分析。 展开更多
关键词 神舟四号飞船 微波辐射计 外定标
下载PDF
场地自动化定标技术进展 被引量:23
12
作者 李新 郑小兵 尹亚鹏 《大气与环境光学学报》 CAS 2014年第1期17-21,共5页
场地自动化替代定标是光学遥感卫星定标发展的新方向。自动化定标通过在场地布设无人值守的全自动观测仪器获取地面和大气光学参数,实施对卫星遥感器的高频次定标,从而提升定标精度。分析了自动化定标的方法和技术发展现状,针对自动定... 场地自动化替代定标是光学遥感卫星定标发展的新方向。自动化定标通过在场地布设无人值守的全自动观测仪器获取地面和大气光学参数,实施对卫星遥感器的高频次定标,从而提升定标精度。分析了自动化定标的方法和技术发展现状,针对自动定标的应用需求,提出了自动化定标设备的设计方案和关键技术,讨论了自动化定标的未来发展前景。 展开更多
关键词 自动化定标 替代定标 光谱反射率 辐射校正场
下载PDF
全天空红外测云系统辐射传感器的替代定标 被引量:6
13
作者 孙学金 刘剑 毛节泰 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2009年第1期54-57,共4页
为了实现全天空红外测云系统辐射传感器业务运行过程中的定标,提出了一种以晴空辐射为标准辐射场的替代定标方法.根据SBDART辐射传输模式计算出的晴空大气向下红外辐射以及辐射传感器对天空观测的输出量化值,利用线性回归方法确定出传... 为了实现全天空红外测云系统辐射传感器业务运行过程中的定标,提出了一种以晴空辐射为标准辐射场的替代定标方法.根据SBDART辐射传输模式计算出的晴空大气向下红外辐射以及辐射传感器对天空观测的输出量化值,利用线性回归方法确定出传感器全场各像元的响应率和偏移量.定标结果分析表明,响应率不确定度为2.03DN unit/(W.m-2.sr-1),偏移量具有明显的正态分布特征,为空间随机噪声.标准黑体检验表明温度反演平均误差不超过±1.5℃,能够满足系统定量化应用的要求. 展开更多
关键词 大气遥感 替代定标 全天空红外测云系统 向下红外辐射
下载PDF
星载红外辐射计海上辐射校正方法研究 被引量:4
14
作者 董仁杰 李铜基 +1 位作者 陈清莲 任洪启 《海洋技术》 2006年第2期73-77,共5页
以FY-1D卫星的热红外通道为例,利用2003年黄东海海上试验站点及其周围海域对辐射校正原理进行了分析研究,包括对现场辐亮度的测量、星地光谱匹配、大气辐射传输计算、辐射校正系数获取等方面的研究。
关键词 热红外 辐射校正 辐射传输计算
下载PDF
机载成像光谱仪的外定标方法 被引量:1
15
作者 张玉香 张广顺 +2 位作者 邱康睦 王志强 张立军 《应用气象学报》 CSCD 北大核心 1998年第4期485-491,共7页
该文描述了基于反射率方法的机载中分辨率成像光谱仪(AMODIS)外定标方法.可见光和近红外波段的17个通道定标结果表明,成像光谱仪两个飞行高度测值的外定标系数是非常吻合的,其相对差为0.19%~3.89%;成像光谱仪... 该文描述了基于反射率方法的机载中分辨率成像光谱仪(AMODIS)外定标方法.可见光和近红外波段的17个通道定标结果表明,成像光谱仪两个飞行高度测值的外定标系数是非常吻合的,其相对差为0.19%~3.89%;成像光谱仪关于草地航测的反演值与地面实测值比较,结果也是比较接近的. 展开更多
关键词 外定标 反射率测量 辐射传输 机载成像光谱仪
下载PDF
风云三号A星中分辨率光谱成像仪反射太阳波段的多场地定标跟踪 被引量:10
16
作者 孙凌 胡秀清 +1 位作者 郭茂华 徐娜 《气象科技进展》 2013年第4期84-96,共13页
搭载于中国第二代极轨气象卫星FY-3A上的中分辨率光谱成像仪(MERSI)是一个类似于MODIS的传感器,具有19个反射太阳波段和一个热红外波段。尽管MERSI配备了可见光星上定标试验设备,但是其只能用于仪器响应的衰减追踪。每年一次的敦煌... 搭载于中国第二代极轨气象卫星FY-3A上的中分辨率光谱成像仪(MERSI)是一个类似于MODIS的传感器,具有19个反射太阳波段和一个热红外波段。尽管MERSI配备了可见光星上定标试验设备,但是其只能用于仪器响应的衰减追踪。每年一次的敦煌场地替代定标一直是MERSI反射太阳波段在轨绝对辐射定标的主要方法。为了提高在轨定标频次,提出了多场地辐射定标跟踪方法。该方法依赖于多个稳定目标场的大气顶模拟辐射,并基于定标系数时间序列的趋势分析建立了定标日更新模型。以Aqua MODIS观测值为参考,对MERSI的定标基准进行了评估,两者的平均相对偏差在5%以内(0.4~2.1μm)。研究发现:MERSI的短波部分衰减显著,特别是412nm波段,年衰减率达9.7%;红光和近红外波段相对稳定,年衰减率在±1%以内。采用多种方法分析了MERSI定标结果的可靠性。多场地定标和敦煌场年度替代定标结果间的相对偏差小于3.8%。以Aqua MODIS为参考对定标后的MERSI数据进行了辐射质量监测,双差分析表明在辐射稳定的沙漠地区,两者的平均相对偏差约在5%之内;同时星下点观测分析也显示出良好的一致性。 展开更多
关键词 风云3A(FY-3A) 中分辨率光谱成像仪(MERSI) 多场地 反射太阳波段 替代定标
下载PDF
风云三号A星中分辨率光谱成像仪反射太阳波段辐射定标 被引量:9
17
作者 胡秀清 孙凌 +6 位作者 刘京晶 丁雷 王向华 李元 张勇 徐娜 陈林 《气象科技进展》 2013年第4期71-83,共13页
中分辨率光谱成像仪(MERSI)是搭载在我国第二代极轨气象卫星风云三号(FY-3)上的一个主要仪器。总结了MERSI在仪器设计、定标算法、发射前及在轨性能以及仪器性能验证等方面的信息。针对MERISI可见光星上定标器(VOC)的跟踪监测发现,在过... 中分辨率光谱成像仪(MERSI)是搭载在我国第二代极轨气象卫星风云三号(FY-3)上的一个主要仪器。总结了MERSI在仪器设计、定标算法、发射前及在轨性能以及仪器性能验证等方面的信息。针对MERISI可见光星上定标器(VOC)的跟踪监测发现,在过去两年,它的太阳反射波段(RSBs)发生了显著的衰减,特别是较短波长通道(<500nm)衰减量超过10%,最大衰减发生在第8波段,约20%。但波长较长通道的性能相对稳定,衰减量小于5%。两个短波红外通道电子增益出现随机跃动,导致发射后的定标系数存在频繁波动。以上结果与其他两种替代定标方法相比(即中国遥感卫星辐射校正场定标,简称场地定标和基于Terra/MODIS敦煌沙漠场景交叉定标),结论一致。MERSI针对大气顶辐射亮度或反射率定标的总不确定度小于5%。定标结果为FY-3A/MERSI定标系数的更新提供了重要的参考和评估。 展开更多
关键词 衰减率 仪器性能跟踪 中分辨率光谱成像仪 反射太阳波段定标 替代定标
下载PDF
场地自动化观测辐射计的设计与实现 被引量:10
18
作者 尹亚鹏 李新 +2 位作者 郑小兵 张志鹏 韦玮 《大气与环境光学学报》 CAS CSCD 2016年第1期44-50,共7页
为了解决场地替代定标中人工测量地表反射率的不足,提高定标频次,获取大量连续的观测数据,研制了场地自动化观测辐射计,该辐射计共8个通道,覆盖可见及近红外波段,光谱带宽20~40 nm,通过北斗卫星实现远程数据传输,可以实现无人职守下的... 为了解决场地替代定标中人工测量地表反射率的不足,提高定标频次,获取大量连续的观测数据,研制了场地自动化观测辐射计,该辐射计共8个通道,覆盖可见及近红外波段,光谱带宽20~40 nm,通过北斗卫星实现远程数据传输,可以实现无人职守下的自动观测和数据回传。对该仪器的工作原理、各单元的设计和特点进行了描述,并给出了辐射计的室内辐射定标方法和结果,最后介绍了辐射计在敦煌辐射校正场的实验情况。 展开更多
关键词 替代定标 反射率 自动化 辐射计
下载PDF
大视场偏振多光谱相机的在轨辐射定标研究进展 被引量:2
19
作者 陈兴峰 刘李 +3 位作者 葛曙乐 李新 张凯南 杨本永 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2020年第2期343-349,共7页
大视场偏振多光谱相机比传统的光谱相机多探测角度和偏振两个维度的信息,尤其在气溶胶遥感监测领域,具有很大优势,所以在2020年前后全球将大量发射搭载该类载荷的卫星。作为定量化程度很高的光学载荷,在轨定标一直受到很大的重视。因受... 大视场偏振多光谱相机比传统的光谱相机多探测角度和偏振两个维度的信息,尤其在气溶胶遥感监测领域,具有很大优势,所以在2020年前后全球将大量发射搭载该类载荷的卫星。作为定量化程度很高的光学载荷,在轨定标一直受到很大的重视。因受限于缺乏星上定标设备和低空间分辨率特点,使用自然景物作为替代参考光源进行在轨辐射定标。多角度偏振相机内部的辐射传递过程复杂,需要进行辐射定标的相机参数有多个。辐射定标系数包括辐射强度和偏振两种类型多个参数,使用的自然景物类型多,导致多种定标方法组合、并行发展。2018年新发射的高分五号卫星是我国第一颗,也是同期国际上唯一搭载偏振运行载荷的卫星,在其后国际上也会有多颗卫星搭载同类型传感器上天,有必要梳理替代定标的研究进展情况。文章系统介绍了大视场偏振多光谱相机的一般光学结构及其光谱设置等重要技术参数,梳理了相机的辐射传递模型。划分了绝对辐射强度、相对辐射强度和偏振参数三类来描述不同定标系数的在轨定标方法和原理。针对特定的待定标系数,介绍了在轨替代定标所需选用的自然景物目标和定标的流程方法。形成了大视场偏振多光谱相机在轨辐射定标的方法系统。并汇总了定标结果检验的一般方法。新的大视场偏振多光谱相机的在轨辐射定标,将继承原有研究基础,使用特殊自然景物开展定标。在后续的同类遥感相机在轨定标工作中,也可以充分借助同一个卫星平台上的其他载荷及其星上定标器、借助地面人工光源等方法开展新形式的在轨辐射定标。我国、欧洲以及美国等规划了新型偏振相机航天发射计划,面向未来几年的我国和欧美诸多同类相机,结合作者研究基础,对未来在轨定标方法进行了初步设计和展望。偏振类型的多光谱相机主要服务于大气颗粒物遥感监测,对我国当前关注的大气环境问题非常重要。卫星发射后持续的在轨辐射定标是保障卫星遥感产品反演精度的必要条件。系统的在轨定标研究梳理和在轨定标未来方法的初步设计将为后续卫星遥感应用系统提供方法和模型参考。 展开更多
关键词 偏振相机 多角度遥感 在轨定标 替代定标
下载PDF
自旋稳定静止气象卫星扫描辐射计水汽通道外定标方法研究 被引量:1
20
作者 王萍 邱康睦 《应用气象学报》 CSCD 北大核心 2000年第1期80-87,共8页
该文利用探空资料,用辐射传输模式LOWTRAN 7,计算了卫星的入瞳辐射率,确定了FY-2 和GMS-5 卫星多通道扫描辐射计水汽通道定标系数.由于星蚀期间星上温度变化迅速,星蚀期间的外定标考虑了星上黑体定标,并用实际... 该文利用探空资料,用辐射传输模式LOWTRAN 7,计算了卫星的入瞳辐射率,确定了FY-2 和GMS-5 卫星多通道扫描辐射计水汽通道定标系数.由于星蚀期间星上温度变化迅速,星蚀期间的外定标考虑了星上黑体定标,并用实际观测值和探空资料做了检验。通过近半年的运行,这种方法取得了较好的效果. 展开更多
关键词 水汽通道 外定标 探空资料 气象卫星 扫描辐射计
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部