期刊文献+
共找到3,225篇文章
< 1 2 162 >
每页显示 20 50 100
A dual-RPA based lateral flow strip for sensitive,on-site detection of CP4-EPSPS and Cry1Ab/Ac genes in genetically modified crops 被引量:1
1
作者 Jinbin Wang Yu Wang +7 位作者 Xiuwen Hu Yifan Chen Wei Jiang Xiaofeng Liu Juan Liu Lemei Zhu Haijuan Zeng Hua Liu 《Food Science and Human Wellness》 SCIE CSCD 2024年第1期183-190,共8页
Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSP... Traditional transgenic detection methods require high test conditions and struggle to be both sensitive and efficient.In this study,a one-tube dual recombinase polymerase amplification(RPA)reaction system for CP4-EPSPS and Cry1Ab/Ac was proposed and combined with a lateral flow immunochromatographic assay,named“Dual-RPA-LFD”,to visualize the dual detection of genetically modified(GM)crops.In which,the herbicide tolerance gene CP4-EPSPS and the insect resistance gene Cry1Ab/Ac were selected as targets taking into account the current status of the most widespread application of insect resistance and herbicide tolerance traits and their stacked traits.Gradient diluted plasmids,transgenic standards,and actual samples were used as templates to conduct sensitivity,specificity,and practicality assays,respectively.The constructed method achieved the visual detection of plasmid at levels as low as 100 copies,demonstrating its high sensitivity.In addition,good applicability to transgenic samples was observed,with no cross-interference between two test lines and no influence from other genes.In conclusion,this strategy achieved the expected purpose of simultaneous detection of the two popular targets in GM crops within 20 min at 37°C in a rapid,equipmentfree field manner,providing a new alternative for rapid screening for transgenic assays in the field. 展开更多
关键词 Genetically modifi ed crops on-site detection Lateral fl ow test strips Dual recombinase polymerase amplification (RPA)
下载PDF
Role of macroscopic on-site evaluation of endoscopic ultrasoundguided fine-needle aspiration/biopsy:Results of a multicentric prospective study
2
作者 Hussein H Okasha Hiwa A Hussein +24 位作者 Khaled M Ragab Omar Abdallah Fedoua Rouibaa Borahma Mohamed Fahd Ghalim Mahmoud Farouk Mohamed Lasheen Mohamed A Elbasiony Ahmed E Alzamzamy Ahmed El Deeb Hassan Atalla Mahmoud El-Ansary Sahar Mohamed Moaz Elshair Wafaa Khannoussi Mohamed Z Abu-Amer Amine Elmekkaoui Mohammed S Naguib Adil Ait Errami Ahmed El-Meligui Ahmed H El-Habashi Mahmoud G Ameen Dalia Abdelfatah Mona Kaddah Hanane Delsa 《World Journal of Gastrointestinal Endoscopy》 2024年第11期595-606,共12页
BACKGROUND The concept of macroscopic on-site evaluation(MOSE)was introduced in 2015 when the endoscopist observed better diagnostic yield when the macroscopically visible core on MOSE was superior to 4 mm.Recent stud... BACKGROUND The concept of macroscopic on-site evaluation(MOSE)was introduced in 2015 when the endoscopist observed better diagnostic yield when the macroscopically visible core on MOSE was superior to 4 mm.Recent studies suggest that MOSE by the endoscopist may be an excellent alternative to rapid on-site evaluation,and some classi-fications have been published.Few studies have assessed the adequacy of histologic cores in MOSE during endoscopic ultrasound-guided fine-needle aspiration/biopsy(EUS-FNA/FNB).AIM To evaluate the performance of MOSE during EUS-FNA/FNB.METHODS This multicentric prospective study was conducted in 16 centers in 3 countries(Egypt,Iraq,and Morocco)and included 1108 patients with pancreatic,biliary,or gastrointestinal pathology who were referred for EUS examination.We prospectively analyzed the MOSE in 1008 patients with available histopathological reports according to 2 classifications to determine the adequacy of the histological core samples.Data management and analysis were performed using a Statistical Package for Social Sciences(SPSS)version 27.RESULTS A total of 1074 solid lesions were biopsied in 1008 patients with available cytopathological reports.Mean age was 59 years,and 509 patients(50.5%)were male.The mean lesion size was 38 mm.The most frequently utilized needles were FNB-Franseen(74.5%)and 22 G(93.4%),with a median of 2 passes.According to 2 classifications,618 non-bloody cores(61.3%)and 964 good samples(95.6%)were adequate for histological evaluation.The overall diagnostic yield of cytopathology was 95.5%.The cytological examination confirmed the diagnosis of malignancy in 861 patients(85.4%),while 45 samples(4.5%)were inconclusive.Post-procedural adverse events occurred in 33 patients(3.3%).Statistical analysis showed a difference between needle types(P=0.035)with a high sensitivity of FNB(97%).The analysis of the relationship between the MOSE-score and the final diagnosis showed a significant difference between the different scores of the MOSE(P<0.001).CONCLUSION MOSE is a simple method that allows endoscopists to increase needle passes to improve sample quality.There is significantly higher FNB sensitivity and cytopathology diagnostic yield with good MOSE cores. 展开更多
关键词 Macroscopic on-site evaluation Fine-needle aspiration Fine-needle biopsy Endoscopic ultrasound SPECIMEN
下载PDF
Rapid on-site evaluation of endoscopic-ultrasound-guided fine-needle aspiration diagnosis of pancreatic masses 被引量:17
3
作者 Julio Iglesias-Garcia Jose Lario-Noia +1 位作者 Ihab Abdulkader J Enrique Domínguez-Muoz 《World Journal of Gastroenterology》 SCIE CAS 2014年第28期9451-9457,共7页
Endoscopic ultrasound (EUS) has become an essential tool for the study of pancreatic diseases. Specifically, EUS plays a pivotal role evaluating patients with a known or suspected pancreatic mass. In this setting, dif... Endoscopic ultrasound (EUS) has become an essential tool for the study of pancreatic diseases. Specifically, EUS plays a pivotal role evaluating patients with a known or suspected pancreatic mass. In this setting, differential diagnosis remains a clinical challenge. EUS-guided fine-needle aspiration (FNA) and fine-needle biopsy (FNB) have been proven to be safe and useful tools in this setting. EUS-guided FNA and FNB, by obtaining cytological and/or histological samples, are able to diagnose pancreatic lesions with high sensitivity and specificity. In this context, several methodological features, trying to increase the diagnostic yield of EUS-guided FNA and FNB, have been evaluated. In this review, we focus on the role of rapid on-site evaluation (ROSE). From data reported in the literature, ROSE may increase diagnostic yield of EUS-FNA specimens by 10%-30%, and thus, diagnostic accuracy. However, we should point out that many recent studies have reported adequacy rates of &#x0003e; 90% without ROSE, indicating that, perhaps, at high-volume centers, ROSE may not be indispensable to achieve excellent results. The use of ROSE can be considered important during the learning curve of EUS-FNA, and also in hospital with diagnostic accuracy rates &#x0003c; 90%. 展开更多
关键词 Endoscopic-ultrasound-guided fine-needle aspiration Rapid on-site evaluation Solid pancreatic tumors Diagnostic accuracy
下载PDF
Improved edge lightweight YOLOv4 and its application in on-site power system work 被引量:5
4
作者 Kexin Li Liang Qin +3 位作者 Qiang Li Feng Zhao Zhongping Xu Kaipei Liu 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期168-180,共13页
A“cloud-edge-end”collaborative system architecture is adopted for real-time security management of power system on-site work,and mobile edge computing equipment utilizes lightweight intelligent recognition algorithm... A“cloud-edge-end”collaborative system architecture is adopted for real-time security management of power system on-site work,and mobile edge computing equipment utilizes lightweight intelligent recognition algorithms for on-site risk assessment and alert.Owing to its lightweight and fast speed,YOLOv4-Tiny is often deployed on edge computing equipment for real-time video stream detection;however,its accuracy is relatively low.This study proposes an improved YOLOv4-Tiny algorithm based on attention mechanism and optimized training methods,achieving higher accuracy without compromising the speed.Specifically,a convolution block attention module branch is added to the backbone network to enhance the feature extraction capability and an efficient channel attention mechanism is added in the neck network to improve feature utilization.Moreover,three optimized training methods:transfer learning,mosaic data augmentation,and label smoothing are used to improve the training effect of this improved algorithm.Finally,an edge computing equipment experimental platform equipped with an NVIDIA Jetson Xavier NX chip is established and the newly developed algorithm is tested on it.According to the results,the speed of the improved YOLOv4-Tiny algorithm in detecting on-site dress code compliance datasets is 17.25 FPS,and the mean average precision(mAP)is increased from 70.89%to 85.03%. 展开更多
关键词 on-site power system work YOLOv4-Tiny Convolution block attention mechanism Efficient channel attention Optimized training methods.
下载PDF
Cheesy material on macroscopic on-site evaluation after endoscopic ultrasound-guided fine-needle biopsy:Don't miss the tuberculosis 被引量:1
5
作者 Hanane Delsa Khadija Bellahammou +1 位作者 Hussein Hassan Okasha Fahd Ghalim 《World Journal of Clinical Cases》 SCIE 2023年第10期2181-2188,共8页
Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB)is an excellent investigation to diagnose pancreatic lesions and has shown high accuracy for its use in pathologic diagnosis.Recently,macroscopic on-site evaluat... Endoscopic ultrasound-guided fine-needle biopsy(EUS-FNB)is an excellent investigation to diagnose pancreatic lesions and has shown high accuracy for its use in pathologic diagnosis.Recently,macroscopic on-site evaluation(MOSE)performed by an endoscopist was introduced as an alternative to rapid on-site cytologic evaluation to increase the diagnostic yield of EUS-FNB.The MOSE of the biopsy can estimate the adequacy of the sample directly by the macroscopic evaluation of the core tissue obtained from EUS-FNB.Isolated pancreatic tuberculosis is extremely rare and difficult to diagnose because of its non-specific signs and symptoms.Therefore,this challenging diagnosis is based on endoscopy,imaging,and the bacteriological and histological examination of tissue biopsies.This uncommon presentation of tuberculosis can be revealed as pancreatic mass mimicking cancer.EUS-FNB can be very useful in providing a valuable histopathological diagnosis.A calcified lesion with a cheesy core in MOSE must be suggestive of tuberculosis,leading to the request of the GeneXpert,which can detect Mycobacterium tuberculosis deoxyribonucleic acid and resistance to rifampicin.A decent diagnostic strategy is crucial to prevent unnecessary surgical resection and to supply conservative management with antitubercular therapy. 展开更多
关键词 Pancreatic tuberculosis Endoscopic ultrasound Fine-needle biopsy Macroscopic on-site evaluation Cheesy material GeneXpert
下载PDF
Random Forests Algorithm Based Duplicate Detection in On-Site Programming Big Data Environment 被引量:1
6
作者 Qianqian Li Meng Li +1 位作者 Lei Guo Zhen Zhang 《Journal of Information Hiding and Privacy Protection》 2020年第4期199-205,共7页
On-site programming big data refers to the massive data generated in the process of software development with the characteristics of real-time,complexity and high-difficulty for processing.Therefore,data cleaning is e... On-site programming big data refers to the massive data generated in the process of software development with the characteristics of real-time,complexity and high-difficulty for processing.Therefore,data cleaning is essential for on-site programming big data.Duplicate data detection is an important step in data cleaning,which can save storage resources and enhance data consistency.Due to the insufficiency in traditional Sorted Neighborhood Method(SNM)and the difficulty of high-dimensional data detection,an optimized algorithm based on random forests with the dynamic and adaptive window size is proposed.The efficiency of the algorithm can be elevated by improving the method of the key-selection,reducing dimension of data set and using an adaptive variable size sliding window.Experimental results show that the improved SNM algorithm exhibits better performance and achieve higher accuracy. 展开更多
关键词 on-site programming big data duplicate record detection random forests adaptive sliding window
下载PDF
New Explorations of Laboratory and On-site Testing of Broadband Seismographs in China
7
作者 XIE Jianbo YANG Dake +6 位作者 LI Xiaojun YUAN Songyong TONG Wanglian MA Jiemei XU Weiwei DING Lisha YE Shishan 《Earthquake Research in China》 CSCD 2019年第1期9-23,共15页
According to different testing purposes, methods and available environmental conditions, the seismograph testing can be divided into laboratory and on-site testing, respectively. The testing of the seismograph's k... According to different testing purposes, methods and available environmental conditions, the seismograph testing can be divided into laboratory and on-site testing, respectively. The testing of the seismograph's key parameters and other concerning technical specifications are well described in guide documents(China Earthquake Administration, 2017). This includes seismometer sensitivity, linearity and clip levels based on the shake table test, as well as the seismometer natural period, damping constant based on electrical calibration(Wang Guangfu,1986; Ple?inger A.,1993) and instrumental self-noise collocation estimation(Holcomb L.G., 1989; Sleeman R. et al., 2006). However, with the development of seismic observation technology, many new requirements for the performance evaluation of seismographs have been put forward, and new testing items and methods have emerged. 展开更多
关键词 BROADBAND seismographs LABORATORY TESTING on-site TESTING
下载PDF
Dynamical energy equipartition of the Toda model with additional on-site potentials
8
作者 张振俊 唐春梅 +1 位作者 康静 童培庆 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期107-111,共5页
We study the dynamical energy equipartition properties in the integrable Toda model with additional uniform or disordered on-site energies by extensive numerical simulations. The total energy is initially equidistribu... We study the dynamical energy equipartition properties in the integrable Toda model with additional uniform or disordered on-site energies by extensive numerical simulations. The total energy is initially equidistributed among some of the lowest frequency linear modes. For the Toda model with uniform on-site potentials, the energy spectrum keeps its profile nearly unchanged in a relatively short time scale. On a much longer time scale, the energies of tail modes increase slowly with time. Energy equipartition is far away from being attached in our studied time scale. For the Toda model with disordered on-site potentials, the energy transfers continuously to the high frequency modes and eventually towards energy equipartition. We further perform a systematic study of the equipartition time teq depending on the energy density ε and the nonlinear parameter α in the thermodynamic limit for the Toda model with disordered on-site potentials. We find teq∝ (1/ε)^a(1/α)^b, where b≈ 2a. The values of a and b are increased when increasing the strengths of disordered on-site potentials or decreasing the number of initially excited modes. 展开更多
关键词 energy transport behaviors Toda model uniform or disordered on-site potentials
下载PDF
Increased Effluent Dosage Effects on On-Site Wastewater Treatment Systems of Differing Architecture Type
9
作者 Andrew Gibbons Kristofor R. Brye +3 位作者 Sam Dunn Edward E. Gbur Andrew N. Sharpley Wen Zhang 《Journal of Environmental Protection》 2015年第6期651-670,共20页
Approximately 20% of homes nationwide use an on-site treatment system as a form of household wastewater management. However, approximately 10% to 20% of on-site treatment systems malfunction each year, many of which h... Approximately 20% of homes nationwide use an on-site treatment system as a form of household wastewater management. However, approximately 10% to 20% of on-site treatment systems malfunction each year, many of which have either failed or exceeded the soil’s long-term acceptance rate (LTAR), causing environmental and human health risks. The objective of this field study was to evaluate the effects of soil condition (e.g., wet and dry) and product architecture type [i.e., chamber, gravel-less-pipe (GLP), polystyrene-aggregate, and pipe-and-aggregate] on in-product solution storage and biomat thickness in a profile-limited soil in northwest Arkansas under increased loading rates and to estimate the LTAR for each product. During Phase I of this study (March 13 to October 4, 2013), effluent loading rates were approximately doubled, while rates were approximately quadrupled during Phase II (October 8, 2013 to May 29, 2014), from the maximum allowable loading rate for each product. The pipe-and-tire-chip, 46-cm-wide trench pipe-and-gravel, and the 25-cm diameter GLP products had the greatest (p < 0.001), while the 31-cm-width and the 5.4-m-long chambers had the lowest (p < 0.001) in-product solution storage during wet-soil conditions of Phase I monitoring. The 25-cm diameter GLP product had the greatest (p < 0.001), while the 61-cm-width, 5.4-m-long chamber had the lowest (p < 0.001) in-product solution storage during Phase II. Results of this study indicate that some alternative products may be able to effectively handle effluent loading rates in excess of those currently allowed by the State of Arkansas. Further research will be required to confirm these interpretations. 展开更多
关键词 on-site WASTEWATER Ozark HIGHLANDS Profile-Limited Soil WASTEWATER Treatment
下载PDF
A rapid on-site calibration method for measuring dynamic envelope curve of high-speed trains
10
作者 LIU Chang-jie YANG Du-juan +1 位作者 FU Lu-hua WANG Zhong 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第3期205-214,共10页
Dynamic envelope curve is a significant parameter to assess the running safety of high-speed trains.Up to now the method based on binocular stereo vision is the only way available to measure the dynamic envelope curve... Dynamic envelope curve is a significant parameter to assess the running safety of high-speed trains.Up to now the method based on binocular stereo vision is the only way available to measure the dynamic envelope curve of a train,the speed of which is over200km/h.Nevertheless the method has two limitations,one is large field-〇f-view(FO V),the other is calibration time.Hence portable calibration equipment,easy-t〇-build target and rapid calibration algorithm are required to complete the calibration.In this paper,a new rapid on-site calibration method with large FOV based on binocular stereo vision is proposed.To address these issues,a light target has been designed,the rail coordinate system(RCS)is represented by40fixed retroreflective points on the target,and they are utilized to calibrate the parameters of two cameras.In addition,two cameras merely capture a single image of the target simultaneously,and the intrinsic and extrinsic parameters of the cameras can be calculated rapidly.To testify the proposed method,the experiments have been conducted and the results reveal that the accuracy can reach+1mm,which can meet the measurement requirement. 展开更多
关键词 high-speed train dynamic envelope curve on-site calibration field-〇f-view (FOV)
下载PDF
On-Site Calibration Method of Dosimeter Based on X-Ray Source
11
作者 Wenhui Lv Huiping Guo +4 位作者 Ning Lv Chenyang Tian Kuo Zhao Xiaotian Wang Yijie Hou 《World Journal of Nuclear Science and Technology》 2017年第2期93-102,共10页
The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nu... The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nuclear facilities there are so many environmental dosimeters installed dispers-edly, because of its huge quantity, widely distributed, and in real-time monitoring state;it will cost lots of manpower and finance if it were tak-en to calibrate on standard laboratory;what’s more it will make the en-vironment out of control. To solve the problem of the measurement ac-curacy of the stationary gamma radiation dosimeter, an on-site calibra-tion method is proposed. The radioactive source is X-ray spectrum, and the dose reference instrument which has been calibrated by the national standard laboratory is a high pressure ionization. On-site calibration is divided into two parts;firstly the energy response experiment of dosim-eter for high and low energy is done in the laboratory, and the energy response curve is obtained combining with Monte Carlo simulation;sec-ondly experiment is carried out in the field of the measuring dosimeter, and the substitution method to calibrate the dosimeter is used;finally the calibration coefficient is gotten through energy curve correction. In order to verify the accuracy of on-site calibration method, the calibrated dosimeter is test in the standard laboratory and the error is 3.4%. The re-sult shows that the on-site calibration method using X-ray is feasible, and it can improves the accuracy of the measurement results of the stationary &gamma;-ray instrument;what’s more important is that it has great reference value for the radiation safety management and radiation environment evaluation. 展开更多
关键词 X RAY SOURCE on-site Calibration Energy Response GAMMA RADIATION DOSIMETER
下载PDF
An Experience of On-site PD Testing for Condition Monitoring of an 11 kV PILC Cable Insulation System
12
作者 Xiaosheng Peng Chengke Zhou Xiaodi Song 《Journal of Energy and Power Engineering》 2012年第1期140-145,共6页
A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to fur... A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to further diagnose and locate the potential problem of the cable system. This paper presents the experience of the present authors carrying out the cable test. Following a brief introduction to the experiment equipments and physical connections, the paper analyses the data collected from the testing, including PD pulse shape analysis, frequency spectrum analysis and phase resolved PD pattern analysis. Associated with PD propagation direction identification, PD source diagnosis and localisation was made. Four different types of sensors, which were adapted during the testing, are shown to have different frequency bandwidths and performed differently. Aider comparing the parameters of the sensor and the PD signals detected by individual sensor, optimal PD monitoring bandwidth for cable system is suggested. 展开更多
关键词 PD identification on-site testing PILC cable switchgear box insulation defect PD propagation direction sensor.
下载PDF
基于Overlay Tester的钢桥面铺装力学特征的数值分析 被引量:5
13
作者 李兴海 黄卫 +2 位作者 钱振东 Ray BROWN 张辰辰 《公路交通科技》 CAS CSCD 北大核心 2013年第10期33-38,共6页
为采用Overlay Tester对钢桥面铺装材料性能进行评价,介绍了其试验方法和理论,利用Abaqus有限元程序建立了局部钢桥面铺装、复合梁和Overlay Tester的三维有限元模型。研究结果表明,3个实体模型具有相似由反弯作用或拉伸作用造成的拉伸... 为采用Overlay Tester对钢桥面铺装材料性能进行评价,介绍了其试验方法和理论,利用Abaqus有限元程序建立了局部钢桥面铺装、复合梁和Overlay Tester的三维有限元模型。研究结果表明,3个实体模型具有相似由反弯作用或拉伸作用造成的拉伸效应应力分布特征。同时,复合梁的钢板部件的应力远大于复合梁的铺装层应力,复合梁的钢板承担了主要试验外力荷载,降低了对铺装层材料评价的针对性。为此,分别对0.63、0.063 mm和0.01 mm 3种不同位移加载模式的Overlay Tester进行数值分析。结果表明,传统的0.63 mm位移拉应力过大,超过铺装材料固有强度,采用0.01 mm的最大拉应力基本与钢桥面铺装的最大拉应力值在一个数量级,考虑到试验周期等因素,最终选定0.063 mm的位移模式作为今后评价钢桥面铺装材料裂缝扩展特性的加载条件。 展开更多
关键词 桥梁工程 力学特征 OVERLAY tester 钢桥面铺装 三维有限元
下载PDF
基于Overlay Tester试验评价沥青混合料抗反射裂缝的能力 被引量:13
14
作者 李兴海 周绪利 +1 位作者 张涛 薛忠军 《中外公路》 北大核心 2015年第3期303-305,共3页
为研究评价沥青混合料抵抗反射裂缝的能力,得克萨斯交通研究中心提出了Overlay Tester试验方法。该文从试验原理、试件制作、试验条件和评价标准等方面,对Overlay Tester试验进行了系统的介绍。然后,通过室内试验,对比分析了不同油石比... 为研究评价沥青混合料抵抗反射裂缝的能力,得克萨斯交通研究中心提出了Overlay Tester试验方法。该文从试验原理、试件制作、试验条件和评价标准等方面,对Overlay Tester试验进行了系统的介绍。然后,通过室内试验,对比分析了不同油石比的沥青混合料的抗裂性能。结果表明:Overlay Tester试验可以有效区别不同沥青含量的沥青混合料的抗裂性能。 展开更多
关键词 道路工程 沥青混合料 OVERLAY tester 反射裂缝
下载PDF
Development of overlay tester for fracture test of asphalt mixture 被引量:2
15
作者 李兴海 黄卫 钱振东 《Journal of Southeast University(English Edition)》 EI CAS 2013年第3期294-299,共6页
To determine the fracture characteristics of asphalt mixture a novel fracture test with modified loading modes loading fixtures and the control system of the conventional overlay tester is implemented by the asphalt m... To determine the fracture characteristics of asphalt mixture a novel fracture test with modified loading modes loading fixtures and the control system of the conventional overlay tester is implemented by the asphalt material performance tester AMPT .In order to evaluate the validity of the proposed fracture test four different loading rates including 1 2 3 and 4 mm/min are examined in the AMPT. The results indicate that the fracture behavior is similar to creep at a low loading rate and does not show significant marginal tail extension at a high loading rate.It clearly shows the phase of crack initiation crack propagation and fracture at a loading rate of 3 mm/min. Besides eight fracture parameters such as fracture energy tensile strength and tensile modulus are applied to evaluate the fracture characteristics of asphalt mixture.Development of the overlay tester for the fracture test of asphalt mixture can be considered as a new fracture test of asphalt mixture. 展开更多
关键词 asphalt mixture fracture test overlay tester asphalt material performance tester (AMPT) fracture parame-ter
下载PDF
USTER TESTER 5-S400-OI纱线检测系统对纺织生产中原棉杂质和灰尘的控制与减少
16
作者 秦贞俊 《国际纺织导报》 2013年第1期54-56,58,共4页
纺织厂为进一步提高棉纱、棉布的质量,纺高支纱时除了要排除一般的杂质及短绒外,还要排除微细杂质及灰尘,以免磨损机器的有关零部件并影响纱线及织物的品质。乌斯特公司生产的USTER TESTER 5-S400-OI纱线检测系统采用了新的光电传感器... 纺织厂为进一步提高棉纱、棉布的质量,纺高支纱时除了要排除一般的杂质及短绒外,还要排除微细杂质及灰尘,以免磨损机器的有关零部件并影响纱线及织物的品质。乌斯特公司生产的USTER TESTER 5-S400-OI纱线检测系统采用了新的光电传感器———OI,可检测纱线中的杂质及灰尘,为纺纱工艺的技术进一步改进,控制与减少杂质及灰尘,提供了可靠的信息。 展开更多
关键词 杂质 灰尘 USTER tester 5-S400-OI纱线检测系统 原理 可重现性
下载PDF
基于overlay tester评价大粒径透水沥青混合料抗反射开裂性能 被引量:17
17
作者 翟瑞鑫 陈永满 +2 位作者 余清华 袁文豪 曾志武 《功能材料》 EI CAS CSCD 北大核心 2017年第9期9129-9135,共7页
针对大粒径透水沥青混合料,采用overlay tester试验,根据荷载周期数、最大荷载损失率、总断裂能、第1周期最大荷载、第1周期最大荷载处位移及第1周期断裂能等指标综合评估其抗反射开裂能力。结果表明,用overlay tester试验测得的荷载周... 针对大粒径透水沥青混合料,采用overlay tester试验,根据荷载周期数、最大荷载损失率、总断裂能、第1周期最大荷载、第1周期最大荷载处位移及第1周期断裂能等指标综合评估其抗反射开裂能力。结果表明,用overlay tester试验测得的荷载周期数、最大荷载损失率可综合反映沥青混合料抗裂性,结果变异性较小;而总断裂能及第1周期指标不能全面准确反映沥青混合料抗裂性;低温及温差较大时橡胶粉改性沥青大粒径混合料抗裂性更佳;overlay tester试验周期—最大荷载曲线符合幂函数变化规律。 展开更多
关键词 大粒径透水沥青混合料 OVERLAY tester 橡胶粉改性沥青 SBS改性沥青 抗反射开裂性
下载PDF
关于tester和driver的译名
18
作者 刘定干 《科技术语研究》 2001年第3期27-28,共2页
本文建议把差减杂交中的tester和driver分别命名为“被测物”和“促减物”。
关键词 差减杂交 命名 tester DRIVER 译名 分子生物学 翻译 英语
下载PDF
Biplot Analysis of Genotype by Environment for Cooking Quality in Hybrid Rice: A Tool for Line × Tester Data 被引量:1
19
作者 Mohammad H. FOTOKIAN Kayvan AGAHI 《Rice science》 SCIE 2014年第5期282-287,共6页
A study of combining ability for improving rice cooking quality was carried out via genotype plus genotype x environment (GGE) biplot. Four restorer lines and three male sterile lines were used to obtain F1 in a lin... A study of combining ability for improving rice cooking quality was carried out via genotype plus genotype x environment (GGE) biplot. Four restorer lines and three male sterile lines were used to obtain F1 in a line x tester trial at the Rice Research Institute, Amol, Iran in 2009. GGE biplot analysis showed that Neda and IR56 were the best general combiners for amylose content (AC), whereas Nemat and IR28 had the highest general combining ability (GCA) effects for gelatinization temperature (GT), and IR58 and IR59 showed the highest GCA effects in terms of gel consistency (GC). Meanwhile IR58 and IR59 showed large specific combining ability (SCA) effects for AC, while Neda and SA13 had high SCA effects for GT. Nemat and IR28 had large SCA effects for GC. Because intermediate levels ofAC, GT and GC are ideal, Nemat × IR59 was considered as the best possible cross. Based on these results, the GGE biplot showed good potential for identifying suitable parents, heterotic crosses and the best hybrids in line x tester data. 展开更多
关键词 line x tester trial general combining ability specific combining ability hybrid rice genotype plus genotype x environment biplot
下载PDF
Erosion-corrosion investigation of high chromium cast irons using newly designed jet type tester 被引量:1
20
作者 TU Xiao-hui LIU Jun-quan LI Wei ZHANG Feng-hua SU Jun-yi 《中国有色金属学会会刊:英文版》 CSCD 2004年第z1期405-412,共8页
A jet type erosion-corrosion tester was developed for the erosion-corrosion investigation of high-chromium cast irons. During tests the size and the shape of particles in the slurry can be maintained stable. The jet v... A jet type erosion-corrosion tester was developed for the erosion-corrosion investigation of high-chromium cast irons. During tests the size and the shape of particles in the slurry can be maintained stable. The jet velocity and attack angle can be accurately controlled. The repeatability and ranking consistency of the test results are satisfactory. The test parameters can be adjusted in a wide range, so that the tester can simulate various practical working conditions. Electrochemical test data can be automatically collected and processed. Dynamic polarization curves can be obtained during erosion-corrosion test, which can be used to study the dynamic corrosion characteristics.Two high chromium cast irons were studied in hot concentrated alkaline slurry. The results show that the erosioncorrosion mass loss rate and dynamic corrosion rate of 295Cr26 iron is lower than that of 185Cr13 under the conditions similar to alumyte processing. The mechanism of erosion-corrosion of 295Cr26 and 185Cr13 was studied by using the tester. The interaction between erosion and corrosion was also quantitatively evaluated. 展开更多
关键词 EROSION-CORROSION tester REPEATABILITY CHROMIUM cast iron hot concentrated ALKALI
下载PDF
上一页 1 2 162 下一页 到第
使用帮助 返回顶部