A comparative numerical study has been conducted on the thermal performance of a heat pipe cooling system considering several influential factors such as the coolant flow rate,the coolant inlet temperature,and the inp...A comparative numerical study has been conducted on the thermal performance of a heat pipe cooling system considering several influential factors such as the coolant flow rate,the coolant inlet temperature,and the input power.A comparison between numerical data and results available in the literature has demonstrated that our numerical procedure could successfully predict the heat transfer performance of the considered heat pipe cooling system for a battery.Specific indicators such as temperature,heat flux,and pressure loss were extracted to describe the characteristics of such a system.On the basis of the distributions of the temperature ratio of the battery surface,together with the heat flux and the streamlines around the heat pipe condenser,we conclude that the low disturbance of the coolant is the cause of the temperature gradient along the fluid flow direction.展开更多
The modern aircraft Thermal Management System(TMS)faces significant challenges due to increasing thermal loads and limited heat dissipation pathways.To optimize TMS during the conceptual design stage,the development o...The modern aircraft Thermal Management System(TMS)faces significant challenges due to increasing thermal loads and limited heat dissipation pathways.To optimize TMS during the conceptual design stage,the development of a modeling and simulation tool is crucial.In this study,a TMS simulation model library was created using MATLAB/SIMULINK.To simplify the complexity of the Vapor Cycle System(VCS)model,a Response Surface Model(RSM)was constructed using the Monte Carlo method and validated through simulation experiments.Taking the F-22 fighter TMS as an example,a thermal dynamic simulation model was constructed to analyze the variation of thermal response parameters in key subsystems and elucidate their coupling relationships.Furthermore,the impact of total fuel flow and ram air flow on the TMS was investigated.The findings demonstrate the existence of an optimal total fuel flow that achieves a balance between maximizing fuel heat sink utilization and minimizing bleed air demand.The adaptive distribution of fuel and ram air flow was found to enhance aircraft thermal management performance.This study contributes to improving modeling efficiency and enhancing the understanding of the thermal dynamic characteristics of TMS,thereby facilitating further optimization in aircraft TMS design.展开更多
This paper provides a comprehensive review on the research and development in multi-scale numerical modeling and simulation of PEM fuel cells. An overview of recent progress in PEM fuel cell modeling has been provided...This paper provides a comprehensive review on the research and development in multi-scale numerical modeling and simulation of PEM fuel cells. An overview of recent progress in PEM fuel cell modeling has been provided. Fundamental transport phenomena in PEM fuel cells and the corresponding mathematical formulation of macroscale models are analyzed. Various important issues in PEM fuel cell modeling and simulation are examined in detail, including fluid flow and species transport, electron and proton transport, heat transfer and thermal management, liquid water transport and water management, transient response behaviors, and cold-start processes. Key areas for further improvements have also been discussed.展开更多
As a part of the Smart Grid concept, an efficient energy management at the residential level has received increasing attention in lately research. Its main focus is to balance the energy consumption in the residential...As a part of the Smart Grid concept, an efficient energy management at the residential level has received increasing attention in lately research. Its main focus is to balance the energy consumption in the residential environment in order to avoid the undesirable peaks faced by the electricity supplier. This challenge can be achieved by means of a home energy management system (HEMS). The HEMS may consider local renewable energy production and energy storage, as well as local control of some particular loads when peaks mitigation is necessary. This paper presents the modeling and comparison of two residential systems;one using conventional electric baseboard heating and the other one supported by Electric Thermal Storage (ETS);the ETS is employed to optimize the local energy utilization pursuing the peak shaving of residential consumption profile. Simulations of the proposed architecture using the Energetic Macroscopic Representation (EMR) demonstrate the potential of ETS technologies in future HEMS.展开更多
This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating syste...This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating system consists of an air source heat pump (ASHP) incorporated with a hot water tank as active Thermal Energy Storage (TES), where two optimization problems are integrated together to optimize both the ASHP electricity consumption and the building heating consumption utilizing a heat dynamic model of the building. The results show that the proposed EMPC can save the energy cost by load shifting compared with some reference cases.展开更多
基金by the Natural Science Foundation of Jiangsu Province(Grants No.BK20170317).
文摘A comparative numerical study has been conducted on the thermal performance of a heat pipe cooling system considering several influential factors such as the coolant flow rate,the coolant inlet temperature,and the input power.A comparison between numerical data and results available in the literature has demonstrated that our numerical procedure could successfully predict the heat transfer performance of the considered heat pipe cooling system for a battery.Specific indicators such as temperature,heat flux,and pressure loss were extracted to describe the characteristics of such a system.On the basis of the distributions of the temperature ratio of the battery surface,together with the heat flux and the streamlines around the heat pipe condenser,we conclude that the low disturbance of the coolant is the cause of the temperature gradient along the fluid flow direction.
文摘The modern aircraft Thermal Management System(TMS)faces significant challenges due to increasing thermal loads and limited heat dissipation pathways.To optimize TMS during the conceptual design stage,the development of a modeling and simulation tool is crucial.In this study,a TMS simulation model library was created using MATLAB/SIMULINK.To simplify the complexity of the Vapor Cycle System(VCS)model,a Response Surface Model(RSM)was constructed using the Monte Carlo method and validated through simulation experiments.Taking the F-22 fighter TMS as an example,a thermal dynamic simulation model was constructed to analyze the variation of thermal response parameters in key subsystems and elucidate their coupling relationships.Furthermore,the impact of total fuel flow and ram air flow on the TMS was investigated.The findings demonstrate the existence of an optimal total fuel flow that achieves a balance between maximizing fuel heat sink utilization and minimizing bleed air demand.The adaptive distribution of fuel and ram air flow was found to enhance aircraft thermal management performance.This study contributes to improving modeling efficiency and enhancing the understanding of the thermal dynamic characteristics of TMS,thereby facilitating further optimization in aircraft TMS design.
基金supported by the National Natural Science Foundation of China (10972197)
文摘This paper provides a comprehensive review on the research and development in multi-scale numerical modeling and simulation of PEM fuel cells. An overview of recent progress in PEM fuel cell modeling has been provided. Fundamental transport phenomena in PEM fuel cells and the corresponding mathematical formulation of macroscale models are analyzed. Various important issues in PEM fuel cell modeling and simulation are examined in detail, including fluid flow and species transport, electron and proton transport, heat transfer and thermal management, liquid water transport and water management, transient response behaviors, and cold-start processes. Key areas for further improvements have also been discussed.
文摘As a part of the Smart Grid concept, an efficient energy management at the residential level has received increasing attention in lately research. Its main focus is to balance the energy consumption in the residential environment in order to avoid the undesirable peaks faced by the electricity supplier. This challenge can be achieved by means of a home energy management system (HEMS). The HEMS may consider local renewable energy production and energy storage, as well as local control of some particular loads when peaks mitigation is necessary. This paper presents the modeling and comparison of two residential systems;one using conventional electric baseboard heating and the other one supported by Electric Thermal Storage (ETS);the ETS is employed to optimize the local energy utilization pursuing the peak shaving of residential consumption profile. Simulations of the proposed architecture using the Energetic Macroscopic Representation (EMR) demonstrate the potential of ETS technologies in future HEMS.
文摘This paper presents a study to optimize the heating energy costs in a residential building with varying electricity price signals based on an Economic Model Predictive Controller (EMPC). The investigated heating system consists of an air source heat pump (ASHP) incorporated with a hot water tank as active Thermal Energy Storage (TES), where two optimization problems are integrated together to optimize both the ASHP electricity consumption and the building heating consumption utilizing a heat dynamic model of the building. The results show that the proposed EMPC can save the energy cost by load shifting compared with some reference cases.