With the support by the National Natural Science Foundation of China,a study by the research groups led by Prof.Cheng Heping(Peace)(程和平)from the State Key Laboratory of Membrane Biology,Institute of Molecular Medic...With the support by the National Natural Science Foundation of China,a study by the research groups led by Prof.Cheng Heping(Peace)(程和平)from the State Key Laboratory of Membrane Biology,Institute of Molecular Medicine,Peking-Tsinghua Center for Life Sciences,Beijing Key Laboratory展开更多
A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only availabl...A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only available in hospitals or laboratories,hindering the spread of point-of-care testing(POCT),especially in underdeveloped areas.Here,we propose a smart Palm-size Optofluidic Hematology Analyzer based on a miniature fluorescence microscope and a microfluidic platform to lighten the device to improve its portability.This gadget has a dimension of 35×30×80 mm and a mass of 39 g,less than 5%of the weight of commercially available flow cytometers.Additionally,automatic leukocyte concentration detection has been realized through the integration of image processing and leukocyte counting algorithms.We compared the leukocyte concentration measurement between our approach and a hemocytometer using the Passing-Bablok analysis and achieved a correlation coefficient of 0.979.Through Bland-Altman analysis,we obtained the relationship between their differences and mean measurement values and established 95%limits of agreement,ranging from−0.93×10^(3)to 0.94×10^(3)cells/μL.We anticipate that this device can be used widely for monitoring and treating diseases such as HIV and tumors beyond hospitals.展开更多
Quantum tunneling conductance of molecular junctions originates from the charge transport through theπ-orbitals(π-transport)and theσ-orbitals(σ-transport)of the molecules,but theσ-transport can not be observed du...Quantum tunneling conductance of molecular junctions originates from the charge transport through theπ-orbitals(π-transport)and theσ-orbitals(σ-transport)of the molecules,but theσ-transport can not be observed due to the more rapid decay of the tunneling conductance in theσ-system compared to that in theπ-system.Here,we demonstrate that dominantσ-transport can be observed inπ-conjugated molecular junctions at the sub-nanometer scale using the scanning tunneling microscope break junction technique(STM-BJ).We have found that the conductance of meta-connected picolinic acid,which mainly occurs byσ-transport,is∼35 times higher than that of its para-isomer,which is entirely different from what is expected fromπ-transport through these systems.Flicker noise analysis reveals that the transport through the meta-connection exhibits more through-bond transport than the para-counterpart and density functional theory(DFT)shows that theσ-system provides the dominant transport path.These results reveal that theσ-electrons,rather than theπ-electrons,can dominate charge transport through conjugated molecular junctions at the sub-nanometer scale,and this provides a new avenue toward the future miniaturization of molecular devices and materials.展开更多
文摘With the support by the National Natural Science Foundation of China,a study by the research groups led by Prof.Cheng Heping(Peace)(程和平)from the State Key Laboratory of Membrane Biology,Institute of Molecular Medicine,Peking-Tsinghua Center for Life Sciences,Beijing Key Laboratory
基金supported by the National Natural Science Foundation of China (grant no.62305083 to W.Z.,grant no.T2222009 to H.L.,grant no.32227802 to H.L.)China Postdoctoral Science Foundation (grant no.2023T160163 to W.Z.grant no.2022M720971 to W.Z.)+2 种基金the Heilongjiang Provincial Postdoctoral Science Foundation (grant no.LBH-Z22027 to W.Z.)the National Key Research and Development Program of China (grant no.2022YFC3400600 to H.L.)the Natural Science Foundation of Heilongjiang Province (grant no.YQ2021F013 to H.L.).
文摘A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only available in hospitals or laboratories,hindering the spread of point-of-care testing(POCT),especially in underdeveloped areas.Here,we propose a smart Palm-size Optofluidic Hematology Analyzer based on a miniature fluorescence microscope and a microfluidic platform to lighten the device to improve its portability.This gadget has a dimension of 35×30×80 mm and a mass of 39 g,less than 5%of the weight of commercially available flow cytometers.Additionally,automatic leukocyte concentration detection has been realized through the integration of image processing and leukocyte counting algorithms.We compared the leukocyte concentration measurement between our approach and a hemocytometer using the Passing-Bablok analysis and achieved a correlation coefficient of 0.979.Through Bland-Altman analysis,we obtained the relationship between their differences and mean measurement values and established 95%limits of agreement,ranging from−0.93×10^(3)to 0.94×10^(3)cells/μL.We anticipate that this device can be used widely for monitoring and treating diseases such as HIV and tumors beyond hospitals.
基金supported by the National Natural Science Foundation of China(21722305,21673195,21973079,and 21703188)the National Key R&D Program of China(2017YFA0204902)the Guangdong Basic and Applied Basic Research Foundation(2020A151511106).
文摘Quantum tunneling conductance of molecular junctions originates from the charge transport through theπ-orbitals(π-transport)and theσ-orbitals(σ-transport)of the molecules,but theσ-transport can not be observed due to the more rapid decay of the tunneling conductance in theσ-system compared to that in theπ-system.Here,we demonstrate that dominantσ-transport can be observed inπ-conjugated molecular junctions at the sub-nanometer scale using the scanning tunneling microscope break junction technique(STM-BJ).We have found that the conductance of meta-connected picolinic acid,which mainly occurs byσ-transport,is∼35 times higher than that of its para-isomer,which is entirely different from what is expected fromπ-transport through these systems.Flicker noise analysis reveals that the transport through the meta-connection exhibits more through-bond transport than the para-counterpart and density functional theory(DFT)shows that theσ-system provides the dominant transport path.These results reveal that theσ-electrons,rather than theπ-electrons,can dominate charge transport through conjugated molecular junctions at the sub-nanometer scale,and this provides a new avenue toward the future miniaturization of molecular devices and materials.