With the acceleration of urbanization and increase of points in power systems,complaints about power grids have increased.In the actual on-site measurement process,although the actual measurement results can meet the ...With the acceleration of urbanization and increase of points in power systems,complaints about power grids have increased.In the actual on-site measurement process,although the actual measurement results can meet the relevant standards,some people are still concerned that the electromagnetic environment may change drastically outside the measurement period,which will have an impact on human health.In this study,the situation of electromagnetic online monitoring systems at home and abroad was introduced firstly,and then some practical requirements for establishing monitoring stations were analyzed.According to existing technologies and related writings,the methods and steps for establishing a quality assurance system were introduced,including the identification of quality assurance system activities and their corresponding structure of quality assurance system documents,the preparation and principles of the documents,and the operation of the quality assurance system.It intends to provide reference for the relevant organizations and personnel conducting electromagnetic environment monitoring when establishing a quality assurance system.Through the establishment of the online monitoring system and the later data publicity,the public have an intuitive understanding of the electromagnetic environment attenuation around power transmission and transformation projects,which can not only make China's electric power industry develop better,but also monitor the unexpected situation in time,maintain public safety and reduce people's fear of electromagnetic radiation in substations.展开更多
An introduction is made to the composition, design method and engineering application of a remote real time monitoring system of power quality in substations based on internet. With virtual instrument and network tec...An introduction is made to the composition, design method and engineering application of a remote real time monitoring system of power quality in substations based on internet. With virtual instrument and network technique adopted, this system is characterized by good real time property, high reliability, plentiful functions, and so on. It also can be used to monitor the load of a substation, such as electric locomotives.展开更多
In recent years,with the rapid development of high-speed railways(HSRs),power interruptions or disturbances in traction power supply systems have become increasingly dangerous.However,it is often impossible to detect ...In recent years,with the rapid development of high-speed railways(HSRs),power interruptions or disturbances in traction power supply systems have become increasingly dangerous.However,it is often impossible to detect these faults immediately through single-point monitoring or collecting data after accidents.To coordinate the power quality data of both traction power supply systems(TPSSs)and high-speed trains(HSTs),a monitoring and assessing system is proposed to access the power quality issues on HSRs.By integrating train monitoring,traction substation monitoring and data center,this monitoring system not only realizes the real-time monitoring of operational behaviors for both TPSSs and HSTs,but also conducts a comprehensive assessment of operational quality for train-network systems.Based on a large number of monitoring data,the field measurements show that this real-time monitoring system is effective for monitoring and evaluating a traction-network system.展开更多
Smart grid puts forward higher requirements for power quality.Power quality evaluation can provide a decision-making basis for quality improvement.Based on power quality monitoring data,a grey target method is propose...Smart grid puts forward higher requirements for power quality.Power quality evaluation can provide a decision-making basis for quality improvement.Based on power quality monitoring data,a grey target method is proposed for power quality evaluation.The grey target is composed of power quality evaluation standard and power quality monitoring data to be evaluated.Combining with the characteristics of each power quality evaluation index,the target center of the whole grey target system is found.Then,the power quality monitoring data to be evaluated and the power quality standard mode are compared and analyzed to construct the power quality grey correlation difference information space.Finally,the target center coefficient and target degree of power quality are calculated to realize the comprehensive evaluation of power quality,and the evaluation grade of power quality monitoring data to be evaluated is obtained.Compared with the evaluation results of the existing literature,the effectiveness of the proposed method is verified,which shows that grey target theory is reasonable in the comprehensive evaluation of power quality.展开更多
This paper introduces the implementation and data analysis associated with a state-wide power quality monitoring and analysis system in China. Corporation specifications on power quality monitors as well as on communi...This paper introduces the implementation and data analysis associated with a state-wide power quality monitoring and analysis system in China. Corporation specifications on power quality monitors as well as on communication protocols are formulated for data transmission. Big data platform and related technologies are utilized for data storage and computation. Compliance verification analysis and a power quality performance assessment are conducted, and a visualization tool for result presentation is finally presented.展开更多
The visualization techniques were explored for power quality monitoring.And remote visualization solutions were proposed for highspeed rail power quality monitoring.Taking the Beijing-Shanghai highspeed rail power mon...The visualization techniques were explored for power quality monitoring.And remote visualization solutions were proposed for highspeed rail power quality monitoring.Taking the Beijing-Shanghai highspeed rail power monitoring as a study case,a remote visualization client,based on our proposed solutions,was developed for high-speed rail power quality monitoring to efficiently support power quality data analysis of the electricity business.The solutions collected data from monitoring stations deployed along the high-speed rail route and visualized the data set with a variety of visualization technologies to alert the specific stations of catastrophic events.The proposed solutions have been proved to be effective in supporting decision-making for the railway power scheduling and providing diagnosis information for quickly spotting any possible runtime failure in operation.展开更多
This paper presents an overview about the new Brazilian Power Quality Standard and provides a low cost device PQ meter, developed and implemented to assist the national campaign to assess the Brazilian power quality i...This paper presents an overview about the new Brazilian Power Quality Standard and provides a low cost device PQ meter, developed and implemented to assist the national campaign to assess the Brazilian power quality indices, unknown until now. This work contributes with the search of a low cost devices PQ meter for a cost sensitive market, and introduces the new Brazilian Power Quality Standard to the international community.展开更多
基金Supported by the Open Project of Jiangsu Key Laboratory of Environmental Engineering(ZX2017005)
文摘With the acceleration of urbanization and increase of points in power systems,complaints about power grids have increased.In the actual on-site measurement process,although the actual measurement results can meet the relevant standards,some people are still concerned that the electromagnetic environment may change drastically outside the measurement period,which will have an impact on human health.In this study,the situation of electromagnetic online monitoring systems at home and abroad was introduced firstly,and then some practical requirements for establishing monitoring stations were analyzed.According to existing technologies and related writings,the methods and steps for establishing a quality assurance system were introduced,including the identification of quality assurance system activities and their corresponding structure of quality assurance system documents,the preparation and principles of the documents,and the operation of the quality assurance system.It intends to provide reference for the relevant organizations and personnel conducting electromagnetic environment monitoring when establishing a quality assurance system.Through the establishment of the online monitoring system and the later data publicity,the public have an intuitive understanding of the electromagnetic environment attenuation around power transmission and transformation projects,which can not only make China's electric power industry develop better,but also monitor the unexpected situation in time,maintain public safety and reduce people's fear of electromagnetic radiation in substations.
文摘An introduction is made to the composition, design method and engineering application of a remote real time monitoring system of power quality in substations based on internet. With virtual instrument and network technique adopted, this system is characterized by good real time property, high reliability, plentiful functions, and so on. It also can be used to monitor the load of a substation, such as electric locomotives.
文摘In recent years,with the rapid development of high-speed railways(HSRs),power interruptions or disturbances in traction power supply systems have become increasingly dangerous.However,it is often impossible to detect these faults immediately through single-point monitoring or collecting data after accidents.To coordinate the power quality data of both traction power supply systems(TPSSs)and high-speed trains(HSTs),a monitoring and assessing system is proposed to access the power quality issues on HSRs.By integrating train monitoring,traction substation monitoring and data center,this monitoring system not only realizes the real-time monitoring of operational behaviors for both TPSSs and HSTs,but also conducts a comprehensive assessment of operational quality for train-network systems.Based on a large number of monitoring data,the field measurements show that this real-time monitoring system is effective for monitoring and evaluating a traction-network system.
文摘Smart grid puts forward higher requirements for power quality.Power quality evaluation can provide a decision-making basis for quality improvement.Based on power quality monitoring data,a grey target method is proposed for power quality evaluation.The grey target is composed of power quality evaluation standard and power quality monitoring data to be evaluated.Combining with the characteristics of each power quality evaluation index,the target center of the whole grey target system is found.Then,the power quality monitoring data to be evaluated and the power quality standard mode are compared and analyzed to construct the power quality grey correlation difference information space.Finally,the target center coefficient and target degree of power quality are calculated to realize the comprehensive evaluation of power quality,and the evaluation grade of power quality monitoring data to be evaluated is obtained.Compared with the evaluation results of the existing literature,the effectiveness of the proposed method is verified,which shows that grey target theory is reasonable in the comprehensive evaluation of power quality.
基金supported by the State Grid Science and Technology Project (GEIRI-DL-71-17-002)
文摘This paper introduces the implementation and data analysis associated with a state-wide power quality monitoring and analysis system in China. Corporation specifications on power quality monitors as well as on communication protocols are formulated for data transmission. Big data platform and related technologies are utilized for data storage and computation. Compliance verification analysis and a power quality performance assessment are conducted, and a visualization tool for result presentation is finally presented.
基金the State Grid Corporation and Computer Science Experimental Center of Beihang University,China
文摘The visualization techniques were explored for power quality monitoring.And remote visualization solutions were proposed for highspeed rail power quality monitoring.Taking the Beijing-Shanghai highspeed rail power monitoring as a study case,a remote visualization client,based on our proposed solutions,was developed for high-speed rail power quality monitoring to efficiently support power quality data analysis of the electricity business.The solutions collected data from monitoring stations deployed along the high-speed rail route and visualized the data set with a variety of visualization technologies to alert the specific stations of catastrophic events.The proposed solutions have been proved to be effective in supporting decision-making for the railway power scheduling and providing diagnosis information for quickly spotting any possible runtime failure in operation.
文摘This paper presents an overview about the new Brazilian Power Quality Standard and provides a low cost device PQ meter, developed and implemented to assist the national campaign to assess the Brazilian power quality indices, unknown until now. This work contributes with the search of a low cost devices PQ meter for a cost sensitive market, and introduces the new Brazilian Power Quality Standard to the international community.