A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s...A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment.展开更多
For purpose of purification and enrichment, environmental samples usually need to be pretreated before analysis because of low concentration of residual organic matters. Solid-phase extraction (SPE) is one of the fr...For purpose of purification and enrichment, environmental samples usually need to be pretreated before analysis because of low concentration of residual organic matters. Solid-phase extraction (SPE) is one of the frequently used methods of pretreatment. This article introduces the methodological principle and flow channel of SPE as well as the categories of frequently used small extraction column, analyzes the application of online SPE technology in environmental analysis, generalizes the advantages of online SPE and sets forth its developmental trend.展开更多
[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From...[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.展开更多
The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasm...The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Standard addition method was applied for the calibration using aqueous solutions. The metals ions absorption were achieved by multiwalled carbon nanotubes (MWNTs) at pH 8.0, and then these retained metals on MWNTs column were eluted by 1.0 mol.L^-1 HNO3. The analytical parameters for the determination ofFe, Cu, and Zn in tap water samples which have been investigated previously were applied. Fifteen tap water samples were collected from different locations of Riyadh metropolitan area and then determined the concentration ofFe, Cu, and Zn by ICP-MS after preconcentration with MWNTs. The concentration range for Fe, Cu, and Zn measured (μg/L) in water samples are 23.37-137.91, 2.12-121.36, and 14.43-202.47 respectively. The level of Fe exceeded the limits set by WHO and SASO for drinking water.展开更多
A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-l...A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction, the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity, accuracy (recovery from urine), repeatability (within-day and between-day precision), specificity, sensitivity, and stability. This SPE-liquid/liquid extraction-RPLC is rapid, simple, accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus, personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments.展开更多
Based on solid phase extraction method, a novel silicon-PDMS-glass microchip for high purity DNA extraction has been developed by using KI as the binding salt. The microfluidic chip fabricated by MEMS technology was c...Based on solid phase extraction method, a novel silicon-PDMS-glass microchip for high purity DNA extraction has been developed by using KI as the binding salt. The microfluidic chip fabricated by MEMS technology was composed of a silicon substrate with a coiled channel and a compounded PDMS-glass cover. With this microfluidic chip, the wall of the coiled channel was used as solid phase matrix for binding DNA and DNA was extracted by the fluxion of the binding buffer, washing buffer and elution buffer. KI as a substitute for guanidine, was used successfully as binding salt for purification DNA, obtaining higher purity of genomic DNA and about 13.9 ng DNA from 1 μL rat whole blood in 35 minutes.展开更多
文摘A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment.
文摘For purpose of purification and enrichment, environmental samples usually need to be pretreated before analysis because of low concentration of residual organic matters. Solid-phase extraction (SPE) is one of the frequently used methods of pretreatment. This article introduces the methodological principle and flow channel of SPE as well as the categories of frequently used small extraction column, analyzes the application of online SPE technology in environmental analysis, generalizes the advantages of online SPE and sets forth its developmental trend.
基金Supported by National Science and Technology Key Project of Water Pollution Control and Management (2012ZX07209-003)
文摘[Method] This study aimed to determine trace amount of polycyclic aromatic hydrocarbons(PAHs) in urban sewage by using solid-phase extraction(SPE) coupled with high performance liquid chromatograph(HPLC).[Method] From the aspects of solid-phase extraction column,elution solvent,elution volume,elution speed and so forth,the test conditions of SPE-HPLC method were optimized,and trace amount of PAHs in urban sewage was determined.[Result] The optimized solid-phase extraction conditions were SUPELCLEAN LC-18 solid-phase extraction column,methylene dichloride as elution solvent,15 ml elution volume,2 ml/min elution speed,5 ml/min loading speed,1 000 ml water with 200 ml methanol loading volume.Under the optimized extraction conditions,the recovery was high,namely 76.3%-105.2%;relative standard deviation was 3.8%-6.0%,showing good precision;detection limit was low,only 0.000 8-0.048 0 μg/L.[Conclusion] This method is user-friendly,with high sensitivity and good precision,and suitable for continuous determination of a large volume of water samples.
文摘The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Standard addition method was applied for the calibration using aqueous solutions. The metals ions absorption were achieved by multiwalled carbon nanotubes (MWNTs) at pH 8.0, and then these retained metals on MWNTs column were eluted by 1.0 mol.L^-1 HNO3. The analytical parameters for the determination ofFe, Cu, and Zn in tap water samples which have been investigated previously were applied. Fifteen tap water samples were collected from different locations of Riyadh metropolitan area and then determined the concentration ofFe, Cu, and Zn by ICP-MS after preconcentration with MWNTs. The concentration range for Fe, Cu, and Zn measured (μg/L) in water samples are 23.37-137.91, 2.12-121.36, and 14.43-202.47 respectively. The level of Fe exceeded the limits set by WHO and SASO for drinking water.
基金supported by the Shanghai Pharmaceutical Association
文摘A highly sensitive SPE-liquid/liquid extraction RPLC method has been developed for the analysis of 6β-hydroxycortisol and cortisol in the urine of cancer patients. Methods: After SPE column purification and liquid-liquid extraction, the sample test solutions were analyzed with RPLC using a C18 analytical column. This improved analytical method has been validated for linearity, accuracy (recovery from urine), repeatability (within-day and between-day precision), specificity, sensitivity, and stability. This SPE-liquid/liquid extraction-RPLC is rapid, simple, accurate and reproducible. The technique is particularly useful for monitoring the CYP3A activity of cancer patients in clinical settings. The results are expressed as the ratio of 6β-hydroxycortisol to cortisol. Results: The CYP3A activity from a total of 153 samples was measured using this improved method. Considerable variation in the CYP3A activity of different cancer patients has been documented. Thus, personalized medical treatment based on the individual metabolic enzyme activity level is necessary. Conclusion: This new analytical method facilitates such individualized medical treatments.
基金the financial support from the National Natural Science Foundation of China(No.20299030,60427001 and 60501020).
文摘Based on solid phase extraction method, a novel silicon-PDMS-glass microchip for high purity DNA extraction has been developed by using KI as the binding salt. The microfluidic chip fabricated by MEMS technology was composed of a silicon substrate with a coiled channel and a compounded PDMS-glass cover. With this microfluidic chip, the wall of the coiled channel was used as solid phase matrix for binding DNA and DNA was extracted by the fluxion of the binding buffer, washing buffer and elution buffer. KI as a substitute for guanidine, was used successfully as binding salt for purification DNA, obtaining higher purity of genomic DNA and about 13.9 ng DNA from 1 μL rat whole blood in 35 minutes.