A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the rel...A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the relatively simple configuration and optics were employed to measure the steel samples at a remote distance and a hot sample temperature. The system has obtained a robustness for the deviation of the sample position because of the open-path and alloptical structure. The measurement was carried out at different sample temperatures by placing the samples in a muffle furnace with a window in the front door. The results show that the intensity of the spectral lines increased as the sample temperature increased. The influence of the sample temperature on the quantitative analysis of manganese in the steel samples was investigated by measuring ten standard steel samples at different temperatures. Three samples were selected as the test sample for the simulation measurement. The results show that, at the sample temperature of 500 ℃, the average relative error of prediction is 3.1% and the average relative standard deviation is 7.7%, respectively.展开更多
An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) la...An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) laser emitting at 1.578 μm and a homemade gas cell with 1-m-long optical path length. The novel sensor is constructed by an electrical cabinet and an optical reflecting and receiving end. The DFB laser is employed for targeting a strong H_2S line at 6 336.62 cm^(-1) in the fundamental absorption band of H_2S. The sensor performance, including the minimum detection limit and the stability, can be improved by reducing the laser intensity drift and common mode noise by means of the WMS-2f/1f technique. The experimental results indicate that the linearity and response time of the sensor are 0.999 26 and 6 s(in concentration range of 15.2—45.6 mg/m^3), respectively. The maximum relative deviation for continuous detection(60 min) of 30.4 mg/m^3 H_2S is 0.48% and the minimum detection limit obtained by Allan variance is 79 μg/m^3 with optimal integration time of 32 s. The optical H_2S sensor can be applied to environmental monitoring and industrial production, and it has significance for real-time online detection in many fields.展开更多
基金supported by National Natural Science Foundation of China (Nos. 51506171 and 51675415)National Natural Science Foundation of China for Key Program (No. 51335009)+1 种基金National Key Research and Development Program of China (No. 2017YFD0700200)the joint research fund between Tokushima University and Xi’an Jiaotong University
文摘A remote open-path laser-induced breakdown spectroscopy(LIBS) system was designed and studied in the present work for the purpose of combining the LIBS technique with the steel production line. In this system, the relatively simple configuration and optics were employed to measure the steel samples at a remote distance and a hot sample temperature. The system has obtained a robustness for the deviation of the sample position because of the open-path and alloptical structure. The measurement was carried out at different sample temperatures by placing the samples in a muffle furnace with a window in the front door. The results show that the intensity of the spectral lines increased as the sample temperature increased. The influence of the sample temperature on the quantitative analysis of manganese in the steel samples was investigated by measuring ten standard steel samples at different temperatures. Three samples were selected as the test sample for the simulation measurement. The results show that, at the sample temperature of 500 ℃, the average relative error of prediction is 3.1% and the average relative standard deviation is 7.7%, respectively.
基金supported by the National Natural Science Foundation of China(Nos.60808020 and 61078041)the Natural Science Foundation of Tianjin(Nos.16JCQNJC02100,15JCYBJC51700 and 16JCYBJC15400)the National Science and Technology Support(No.2014BAH03F01)
文摘An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) laser emitting at 1.578 μm and a homemade gas cell with 1-m-long optical path length. The novel sensor is constructed by an electrical cabinet and an optical reflecting and receiving end. The DFB laser is employed for targeting a strong H_2S line at 6 336.62 cm^(-1) in the fundamental absorption band of H_2S. The sensor performance, including the minimum detection limit and the stability, can be improved by reducing the laser intensity drift and common mode noise by means of the WMS-2f/1f technique. The experimental results indicate that the linearity and response time of the sensor are 0.999 26 and 6 s(in concentration range of 15.2—45.6 mg/m^3), respectively. The maximum relative deviation for continuous detection(60 min) of 30.4 mg/m^3 H_2S is 0.48% and the minimum detection limit obtained by Allan variance is 79 μg/m^3 with optimal integration time of 32 s. The optical H_2S sensor can be applied to environmental monitoring and industrial production, and it has significance for real-time online detection in many fields.