The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange...The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.展开更多
Prediction of bacteria-carrying particle (BCP) dispersion and particle distribution released from staffmem- bers in an operating room (OR) is very important for creating and sustaining a safe indoor environment. P...Prediction of bacteria-carrying particle (BCP) dispersion and particle distribution released from staffmem- bers in an operating room (OR) is very important for creating and sustaining a safe indoor environment. Postoperative wound infections cause significant morbidity and mortality, and contribute to increased hospitalization time. Increasing the number of personnel within the OR disrupts the ventilation airflow pattern and causes enhanced contamination risk in the area of an open wound. Whether the amount of staffwithin the OR influences the BCP distribution in the surgical zone has rarely been investigated. This study was conducted to explore the influence of the number of personnel in the OR on the airflow field and the BCP distribution. This was performed by applying a numerical calculation to map the airflow field and Lagrangian particle tracking (LPT) for the BCP phase. The results are reported both for active sampling and passive monitoring approaches. Not surprisingly, a growing trend in the BCP concentration (cfu/ms) was observed as the amount of staff in the OR increased. Passive sampling shows unpredictable results due to the sedimentation rate, especially for small particles (5-10 i^m). Risk factors for surgical site infections (SSls) must be well understood to develop more effective prevention programs.展开更多
文摘The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.
文摘Prediction of bacteria-carrying particle (BCP) dispersion and particle distribution released from staffmem- bers in an operating room (OR) is very important for creating and sustaining a safe indoor environment. Postoperative wound infections cause significant morbidity and mortality, and contribute to increased hospitalization time. Increasing the number of personnel within the OR disrupts the ventilation airflow pattern and causes enhanced contamination risk in the area of an open wound. Whether the amount of staffwithin the OR influences the BCP distribution in the surgical zone has rarely been investigated. This study was conducted to explore the influence of the number of personnel in the OR on the airflow field and the BCP distribution. This was performed by applying a numerical calculation to map the airflow field and Lagrangian particle tracking (LPT) for the BCP phase. The results are reported both for active sampling and passive monitoring approaches. Not surprisingly, a growing trend in the BCP concentration (cfu/ms) was observed as the amount of staff in the OR increased. Passive sampling shows unpredictable results due to the sedimentation rate, especially for small particles (5-10 i^m). Risk factors for surgical site infections (SSls) must be well understood to develop more effective prevention programs.