An optical micro electron mechanical system (MEMS) pressure sensor with a mesa membrane is presented. The operating principle of the MEMS pressure sensor is expatiated by the Fabry-Perot (F-P) interference and the...An optical micro electron mechanical system (MEMS) pressure sensor with a mesa membrane is presented. The operating principle of the MEMS pressure sensor is expatiated by the Fabry-Perot (F-P) interference and the relation between deflection and pressure is analyzed. Both the mechanical model of the mesa structure diaphragm and the signal averaging effect is validated by simulation, which declares that the mesa structure diaphragm is superior to the planar one on the parallelism and can reduce the signal averaging effect. Experimental results demonstrate that the mesa structure sensor has a reasonable linearity and sensitivity.展开更多
This paper presents a novel miniaturized fiber-optic Fabry-Peort interferometer (FPI) for highly sensitive refractive index measurement. This device was tested for the refractive indices of various liquids including...This paper presents a novel miniaturized fiber-optic Fabry-Peort interferometer (FPI) for highly sensitive refractive index measurement. This device was tested for the refractive indices of various liquids including acetone and ethanol at room temperature. The sensitivity for measurement of refractive index change of ethanol is 1138 nm/RIU at the wavelength of 1550 nm. In addition, the sensor fabrication is simple including only cleaving, splicing, and etching. The signal is stable with high visibility. Therefore, it provides a valuable tool in biological and chemical applications.展开更多
To achieve high quality factor and high-sensitivity refractive index sensor,a slot micro-ring resonator(MRR)based on asymmetric Fabry-Perot(FP)cavity was proposed.The structure consisted of a pair of elliptical holes ...To achieve high quality factor and high-sensitivity refractive index sensor,a slot micro-ring resonator(MRR)based on asymmetric Fabry-Perot(FP)cavity was proposed.The structure consisted of a pair of elliptical holes to form an FP cavity and a microring resonator.The two different optical modes generated by the micro-ring resonator were destructively interfered to form a Fano line shape,which improved the system sensitivity while obtaining a higher quality factor and extinction ratio.The transmission principle of the structure was analyzed by the transfer matrix method.The transmission spectrum and mode field distribution of the proposed structure were simulated by the finite difference time domain(FDTD)method,and the key structural parameters affecting the Fano line shape in the device were optimized.The simulation results show that the quality factor of the device reached 22037.1,and the extinction ratio was 23.9 dB.By analyzing the refractive index sensing characteristics,the sensitivity of the structure was 354 nm·RIU−1,and the detection limit of the sensitivity was 2×10−4 RIU.Thus,the proposed compact asymmetric FP cavity slot micro-ring resonator has obvious advantages in sensing applications owing to its excellent performance.展开更多
A narrow linewidth continuous wave Ho:YAP laser with two Fabry-Perot etalons pumped by a Tm:YLF laser is reported. The maximum output power reaches 8.3 W when the incident pump power is 15.8 W, with 52.5% optical-to...A narrow linewidth continuous wave Ho:YAP laser with two Fabry-Perot etalons pumped by a Tm:YLF laser is reported. The maximum output power reaches 8.3 W when the incident pump power is 15.8 W, with 52.5% optical-to- optical conversion efficiency and 62.6% slope efficiency. A stable laser output at 2118.1 nm is achieved, with a linewidth less than 0.4 nm (full width at half maximum). The beam quality factor is M2- 1.25, measured by the traveling knife-edge method.展开更多
Based on dual-differential comparing principle, an experimental system of optical fiber F-P interferometric micro-displacement measurement is introduced. It is capable of achieving the absolute displacement measuremen...Based on dual-differential comparing principle, an experimental system of optical fiber F-P interferometric micro-displacement measurement is introduced. It is capable of achieving the absolute displacement measurement, and wavelet transforms is adopted as theory fundament to extract the optical F-P interferometric characteristic signal and remove the noise, so its resolution can reach 0. 01 μm in the dynamic range of 0~ 1 mm.展开更多
The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is pe...The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is performed and the analytical equations describing the dependence of resolution on parameters of the interrogation setup are derived. The efficiency of the proposed signal processing approaches and the validity of analytical derivations are supported by experiments. The proposed approaches allow the interrogation of up to four multiplexed sensors with attained resolution between 30 pm and 80 pm, up to three times improvement of microdisplacement resolution of a single sensor by means of using the reference interferometer and noisecompensating approach, and ability to register signals with frequencies up to 1 kHz in the case of 1 Hz spectrum acquisition rate. The proposed approaches can be used for various applications, including biomedical, industrial inspection, and others, amongst the microdisplacement measurement.展开更多
The design concepts, modelling and implementation of various fibre optic sensor protection systems for development in concrete structures were investigated. Design concepts and on-site requirements for surface-mounted...The design concepts, modelling and implementation of various fibre optic sensor protection systems for development in concrete structures were investigated. Design concepts and on-site requirements for surface-mounted and embedded optical fibre sensor in concrete were addressed. Finite element (FE) modelling of selected sensor protection systems in strain-transfer efficiency from the structure to the sensing region was also studied. And experimental validation of specified sensor protection system was reported. Results obtained indicate that the protection system for the sensors performs adequately in concrete environment and there is very good correlation between results obtained by the protected fibre optic sensors and conventional electrical resistance strain gauges.展开更多
文摘An optical micro electron mechanical system (MEMS) pressure sensor with a mesa membrane is presented. The operating principle of the MEMS pressure sensor is expatiated by the Fabry-Perot (F-P) interference and the relation between deflection and pressure is analyzed. Both the mechanical model of the mesa structure diaphragm and the signal averaging effect is validated by simulation, which declares that the mesa structure diaphragm is superior to the planar one on the parallelism and can reduce the signal averaging effect. Experimental results demonstrate that the mesa structure sensor has a reasonable linearity and sensitivity.
基金supported by the Key Project of Natural Science Foundation of China under Grant No. 60537040the Natural Science Foundation Project of CQ CSTC under Grant No. 2007BB3125
文摘This paper presents a novel miniaturized fiber-optic Fabry-Peort interferometer (FPI) for highly sensitive refractive index measurement. This device was tested for the refractive indices of various liquids including acetone and ethanol at room temperature. The sensitivity for measurement of refractive index change of ethanol is 1138 nm/RIU at the wavelength of 1550 nm. In addition, the sensor fabrication is simple including only cleaving, splicing, and etching. The signal is stable with high visibility. Therefore, it provides a valuable tool in biological and chemical applications.
基金supported by Natural Science Foundation of Gansu Province(No.22JR5RA320).
文摘To achieve high quality factor and high-sensitivity refractive index sensor,a slot micro-ring resonator(MRR)based on asymmetric Fabry-Perot(FP)cavity was proposed.The structure consisted of a pair of elliptical holes to form an FP cavity and a microring resonator.The two different optical modes generated by the micro-ring resonator were destructively interfered to form a Fano line shape,which improved the system sensitivity while obtaining a higher quality factor and extinction ratio.The transmission principle of the structure was analyzed by the transfer matrix method.The transmission spectrum and mode field distribution of the proposed structure were simulated by the finite difference time domain(FDTD)method,and the key structural parameters affecting the Fano line shape in the device were optimized.The simulation results show that the quality factor of the device reached 22037.1,and the extinction ratio was 23.9 dB.By analyzing the refractive index sensing characteristics,the sensitivity of the structure was 354 nm·RIU−1,and the detection limit of the sensitivity was 2×10−4 RIU.Thus,the proposed compact asymmetric FP cavity slot micro-ring resonator has obvious advantages in sensing applications owing to its excellent performance.
基金Project supported by the Fundamental Research Funds for the Central Universities,China(Grant No.GK2030260112)
文摘A narrow linewidth continuous wave Ho:YAP laser with two Fabry-Perot etalons pumped by a Tm:YLF laser is reported. The maximum output power reaches 8.3 W when the incident pump power is 15.8 W, with 52.5% optical-to- optical conversion efficiency and 62.6% slope efficiency. A stable laser output at 2118.1 nm is achieved, with a linewidth less than 0.4 nm (full width at half maximum). The beam quality factor is M2- 1.25, measured by the traveling knife-edge method.
文摘Based on dual-differential comparing principle, an experimental system of optical fiber F-P interferometric micro-displacement measurement is introduced. It is capable of achieving the absolute displacement measurement, and wavelet transforms is adopted as theory fundament to extract the optical F-P interferometric characteristic signal and remove the noise, so its resolution can reach 0. 01 μm in the dynamic range of 0~ 1 mm.
文摘The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is performed and the analytical equations describing the dependence of resolution on parameters of the interrogation setup are derived. The efficiency of the proposed signal processing approaches and the validity of analytical derivations are supported by experiments. The proposed approaches allow the interrogation of up to four multiplexed sensors with attained resolution between 30 pm and 80 pm, up to three times improvement of microdisplacement resolution of a single sensor by means of using the reference interferometer and noisecompensating approach, and ability to register signals with frequencies up to 1 kHz in the case of 1 Hz spectrum acquisition rate. The proposed approaches can be used for various applications, including biomedical, industrial inspection, and others, amongst the microdisplacement measurement.
文摘The design concepts, modelling and implementation of various fibre optic sensor protection systems for development in concrete structures were investigated. Design concepts and on-site requirements for surface-mounted and embedded optical fibre sensor in concrete were addressed. Finite element (FE) modelling of selected sensor protection systems in strain-transfer efficiency from the structure to the sensing region was also studied. And experimental validation of specified sensor protection system was reported. Results obtained indicate that the protection system for the sensors performs adequately in concrete environment and there is very good correlation between results obtained by the protected fibre optic sensors and conventional electrical resistance strain gauges.