A streaked optical pyrometer (SOP) is developed and calibrated for the measurement of the temperature of shocked materials. In order to achieve a higher relative sensitivity, a onechannel scheme is adopted for the s...A streaked optical pyrometer (SOP) is developed and calibrated for the measurement of the temperature of shocked materials. In order to achieve a higher relative sensitivity, a onechannel scheme is adopted for the system. The system is calibrated with a shocked step-shaped aluminum sample in the SG-III prototype laser facility. The relation between the count number in the detection system and the sample temperature is thus obtained, which can be adopted to infer the temperature of any shocked materials in future experiments.展开更多
Based on the theory of thermal radiation,a contact type optical fiber pyrometer applied in IC engine is put forward.It is composed of three parts:a blackbody probe,optical system,electrical process system.The key tech...Based on the theory of thermal radiation,a contact type optical fiber pyrometer applied in IC engine is put forward.It is composed of three parts:a blackbody probe,optical system,electrical process system.The key technology of design is discussed.Experiment is given to prove that the pyrometer has much higher responsive speed,distinguishability and much longer running life than other pyrometers.展开更多
Based on the concept of thermo-radiation theory,the principle of non-contact temperature measurement with optical fiber is introduced.The new pyrometer operates on the basis of two-way temperature signal division calc...Based on the concept of thermo-radiation theory,the principle of non-contact temperature measurement with optical fiber is introduced.The new pyrometer operates on the basis of two-way temperature signal division calculation via microcomputer signal processing system.Its design method and smart construction of the electro-optical system possess such advantages as high measurement accuracy,freedom from electric interference and other perturbations as well as flexible applications.The indication scale of the measured temperature and experiment results are given in this paper.展开更多
The velocity interferometer system for any reflector(VISAR) coupled with a streaked optical pyrometer(SOP) system is used as a diagnostic tool in inertial confinement fusion(ICF) experiments involving equations of sta...The velocity interferometer system for any reflector(VISAR) coupled with a streaked optical pyrometer(SOP) system is used as a diagnostic tool in inertial confinement fusion(ICF) experiments involving equations of state and shock timing.To validate the process of adiabatically compressing the fuel shell through precise tuning of shocks in experimental campaigns for the double-cone ignition(DCI) scheme of ICF, a compact line-imaging VISAR with an SOP system is designed and implemented at the Shenguang-II upgrade laser facility. The temporal and spatial resolutions of the system are better than 30 ps and 7 μm, respectively. An illumination lens is used to adjust the lighting spot size matching with the target size. A polarization beam splitter and λ/4 waveplate are used to increase the transmission efficiency of our system. The VISAR and SOP work at 660 and 450 nm, respectively, to differentiate the signals from the scattered lights of the drive lasers. The VISAR can measure the shock velocity. At the same time, the SOP system can give the shock timing and relative strength. This system has been used in different DCI campaigns, where the generation and propagation processes of multi-shock are carefully diagnosed.展开更多
In order to study the light flash radiant intensity produced by strong shock on a 2A12 aluminum target at the same projectile incidence angles and different shock velocities,experimental measurements were conducted fo...In order to study the light flash radiant intensity produced by strong shock on a 2A12 aluminum target at the same projectile incidence angles and different shock velocities,experimental measurements were conducted for light flash phenomena of a 2A12 aluminum projectile impacting a 2A12 aluminum target under the conditions of different impact velocity and the same projectile incidence angles of 45° by using an optical pyrometer measurement system and a two-stage light gas gun loading system.Experimental results show that the peak values of the light flash radiant intensity for the wavelength of 550 nm are largest in the wavelength ranges of 600 nm,650 nm and 700 nm when a 2A12 aluminum projectile impacts a double-layer 2A12 aluminum plate in the present experimental conditions.展开更多
基金supported by National Natural Science Foundation of China(Nos.11005097 and 1175179)the Innovation Project of the Chinese Academy of Sciences(No.KJCX2-YW-N36)the Project 2010A0102003 supported by CAEP
文摘A streaked optical pyrometer (SOP) is developed and calibrated for the measurement of the temperature of shocked materials. In order to achieve a higher relative sensitivity, a onechannel scheme is adopted for the system. The system is calibrated with a shocked step-shaped aluminum sample in the SG-III prototype laser facility. The relation between the count number in the detection system and the sample temperature is thus obtained, which can be adopted to infer the temperature of any shocked materials in future experiments.
文摘Based on the theory of thermal radiation,a contact type optical fiber pyrometer applied in IC engine is put forward.It is composed of three parts:a blackbody probe,optical system,electrical process system.The key technology of design is discussed.Experiment is given to prove that the pyrometer has much higher responsive speed,distinguishability and much longer running life than other pyrometers.
文摘Based on the concept of thermo-radiation theory,the principle of non-contact temperature measurement with optical fiber is introduced.The new pyrometer operates on the basis of two-way temperature signal division calculation via microcomputer signal processing system.Its design method and smart construction of the electro-optical system possess such advantages as high measurement accuracy,freedom from electric interference and other perturbations as well as flexible applications.The indication scale of the measured temperature and experiment results are given in this paper.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(Grant Nos.XDA25030500 and XDA25010300)the CAS Youth Interdisciplinary Team(Grant No.JCTD-2022-05)+2 种基金the Youth Innovation Promotion Association of the Chinese Academy of Sciencesthe National Natural Science Foundation of China(Grant Nos.11873061 and 12073043)the National Key R&D Program of China(Grant Nos.2022YFA1603200 and 2022YFA1603204)。
文摘The velocity interferometer system for any reflector(VISAR) coupled with a streaked optical pyrometer(SOP) system is used as a diagnostic tool in inertial confinement fusion(ICF) experiments involving equations of state and shock timing.To validate the process of adiabatically compressing the fuel shell through precise tuning of shocks in experimental campaigns for the double-cone ignition(DCI) scheme of ICF, a compact line-imaging VISAR with an SOP system is designed and implemented at the Shenguang-II upgrade laser facility. The temporal and spatial resolutions of the system are better than 30 ps and 7 μm, respectively. An illumination lens is used to adjust the lighting spot size matching with the target size. A polarization beam splitter and λ/4 waveplate are used to increase the transmission efficiency of our system. The VISAR and SOP work at 660 and 450 nm, respectively, to differentiate the signals from the scattered lights of the drive lasers. The VISAR can measure the shock velocity. At the same time, the SOP system can give the shock timing and relative strength. This system has been used in different DCI campaigns, where the generation and propagation processes of multi-shock are carefully diagnosed.
基金supported by National Natural Science Foundation of China(Nos.10972145,11272218,11472178)State Key Program of National Natural Science of China(No.11032003)Program for Liaoning Excellent Talents in University,China(No.LR2013008)
文摘In order to study the light flash radiant intensity produced by strong shock on a 2A12 aluminum target at the same projectile incidence angles and different shock velocities,experimental measurements were conducted for light flash phenomena of a 2A12 aluminum projectile impacting a 2A12 aluminum target under the conditions of different impact velocity and the same projectile incidence angles of 45° by using an optical pyrometer measurement system and a two-stage light gas gun loading system.Experimental results show that the peak values of the light flash radiant intensity for the wavelength of 550 nm are largest in the wavelength ranges of 600 nm,650 nm and 700 nm when a 2A12 aluminum projectile impacts a double-layer 2A12 aluminum plate in the present experimental conditions.