期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
ELASTOHYDRODYNAMIC LUBRICATION OF LOGARITHMIC PROFILE ROLLER CONTACTS 被引量:2
1
作者 Chen Xiaoyang, Shen Xuejin (Research Institute of Bearings,Shanghai University) Xu Wen, Ma Jiaju (Zhejiang University) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第4期347-352,共6页
An account of numerical solutions to the isothermal and flooded elastohydrodynamic lubrication(EHL)of a logarithmic profile roller,which is rolling over a flat plane,is given The analysis takes account of sideways fl... An account of numerical solutions to the isothermal and flooded elastohydrodynamic lubrication(EHL)of a logarithmic profile roller,which is rolling over a flat plane,is given The analysis takes account of sideways flow of lubricant in the inlet region of the contact When the results are presented in suitable non dimensional groups,it is shown that more uniformly pressure and shape of the film distributing in axial direction is taken place under light loading As the increase of the load,the end closure is displayed and the oil pressure rises sharply at the ends The seal action formed by the end closure makes the film thickness a little And the minimum film thickness is transferred from the central to the ends and the value is reduced rapidly As the increase of the speed,the end closure becomes much serious The optimum crowning value obtained in EHL state is larger than the design value obtained in elastostatic contact state for the same working conditions In order to verify the correctness of theory,optical interferometry is applied to measure the oil film thickness between a logarithmic profiled roller and a glass plate under pure rolling conditions It is found the agreement between numerical solutions and experiments is very good. 展开更多
关键词 Elastohydrodynamic lubrication(EHL) Logarithmic profile roller Finite line contacts optical interferom etry measurement
下载PDF
Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
2
作者 Utkarsh Sharma Jin U.Kang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第12期910-912,共3页
The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with... The objective of this study is to demonstrate that tensile stress resulting due to applied force on cornea can be accurately measured by using a time-domain common-path optical coherence tomography (OCT) system with an external contact reference. The unique design of the common-path OCT is utilized to set up an imaging system in which a chicken eye is placed adjacent to a glass plate serving as the external reference plane for the imaging system. As the force is applied to the chicken eye, it presses against the reference glass plate. The modified OCT image obtained is used to calculate the size of contact area, which is then used to derive the tensile stress on the cornea. The drop in signal levels upon contact of reference glass plate with the tissue are extremely sharp because of the sharp decline in reference power levels itself, thus providing us with an accurate measurement of contact area. The experimental results were in good agreement with the numerical predictions. The results of this study might be useful in providing new insights and ideas to improve the precision and safety of currently used ophthalmic surgical techniques. This research outlines a method which could be used to provide high resolution OCT images and a precise feedback of the forces applied to the cornea simultaneously. 展开更多
关键词 Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部