A practical optical fiber differential pressure sensor is presented at first. Then the techniques of light source feedback, set up of reference channel, proportional measurement and other methods to improve the stabil...A practical optical fiber differential pressure sensor is presented at first. Then the techniques of light source feedback, set up of reference channel, proportional measurement and other methods to improve the stability of the system as well as to reduce the interference with same nature are emphatically discussed. Finally, the experiment results of the developed instrument are given.展开更多
The pressure distribution in an arcing chamber is critically important for the SF6 puffer circuit breaker design. In this paper, the pressure variation of four locations in the nozzle was measured by piezoresistive an...The pressure distribution in an arcing chamber is critically important for the SF6 puffer circuit breaker design. In this paper, the pressure variation of four locations in the nozzle was measured by piezoresistive and fiber optical pressure sensors at two current levels of 10 kA and 50 kA. An arc voltage measurement was also taken. The results demonstrate that using either type of sensor with a connecting tube is able to detect the fast pressure variation in circuit breakers, however the possible distortion and delay to the pressure transient caused by the tube need further study.展开更多
Based on thinned fiber Bragg grating and polymer material, we propose a novel high-sensitivity pressure sensor and obtained a new contribution to the pressure sensitivity, which is dependent on the derivative of the e...Based on thinned fiber Bragg grating and polymer material, we propose a novel high-sensitivity pressure sensor and obtained a new contribution to the pressure sensitivity, which is dependent on the derivative of the effective refractive index (RI) of core mode with respect to the surrounding medium RI, as well as on the relationship between the polymer RI and the pressure; moreover, it is inversely proportional to Young's modulus of the polymer material. For the polymer with Young's modulus of 1.0 MPa, the total pressure sensitivity 1.54×10-2 MPa-1 can be obtained.展开更多
文摘A practical optical fiber differential pressure sensor is presented at first. Then the techniques of light source feedback, set up of reference channel, proportional measurement and other methods to improve the stability of the system as well as to reduce the interference with same nature are emphatically discussed. Finally, the experiment results of the developed instrument are given.
文摘The pressure distribution in an arcing chamber is critically important for the SF6 puffer circuit breaker design. In this paper, the pressure variation of four locations in the nozzle was measured by piezoresistive and fiber optical pressure sensors at two current levels of 10 kA and 50 kA. An arc voltage measurement was also taken. The results demonstrate that using either type of sensor with a connecting tube is able to detect the fast pressure variation in circuit breakers, however the possible distortion and delay to the pressure transient caused by the tube need further study.
基金Supported by the National Natural Science Foundation of China (50802069)
文摘Based on thinned fiber Bragg grating and polymer material, we propose a novel high-sensitivity pressure sensor and obtained a new contribution to the pressure sensitivity, which is dependent on the derivative of the effective refractive index (RI) of core mode with respect to the surrounding medium RI, as well as on the relationship between the polymer RI and the pressure; moreover, it is inversely proportional to Young's modulus of the polymer material. For the polymer with Young's modulus of 1.0 MPa, the total pressure sensitivity 1.54×10-2 MPa-1 can be obtained.