With the development of cutting-edge multi-object spectrographs,fiber positioners located in the focal plane are being scaled down in size,and miniature hollow-cup Permanent Magnet motors are now being considered as a...With the development of cutting-edge multi-object spectrographs,fiber positioners located in the focal plane are being scaled down in size,and miniature hollow-cup Permanent Magnet motors are now being considered as a suitable replacement for Faulhaber Precistep stepper motors.However,the small electrical time constant of such coreless motors poses a challenge,as the problem of severe commutation torque ripple in a fiber positioner running a position loop has been tricky.To overcome this challenge,it is advised to increase the Pulse Width Modulation(PWM)frequency as much as possible to mitigate the effects of the current fluctuation.This must be done while ensuring adequate resolution of the PWM generator.By employing a voltage open-loop field-oriented control based on a modulation frequency of 1 MHz,the drive current only costs 25 m A under a 3.3 V power supply.The sine degree of phase current is immaculate,and the repeat positioning accuracy can reach 2μm.Moreover,it is possible to further shrink the bill of devices and the layout area of the Printed Circuit Board,especially in sizesensitive applications.This device has been developed under the new generation of The Large Sky Area MultiObject Fiber Spectroscopic Telescope.展开更多
The portable adaptive optics(PAO)device is a low-cost and compact system,designed for 4-meter class telescopes that have no adaptive optics(AO)system,because of the physical space limitation at the Nasmyth or Cassegra...The portable adaptive optics(PAO)device is a low-cost and compact system,designed for 4-meter class telescopes that have no adaptive optics(AO)system,because of the physical space limitation at the Nasmyth or Cassegrain focus and the historically high cost of conventional AO.The initial scientific observations of the PAO are focused on the direct imaging of exoplanets and sub-stellar companions.This paper discusses the concept of PAO and the associated high-contrast imaging performance in our recent observational runs.PAO deliver a Strehl ratio better than 60%in H band under median seeing conditions of 1".Combined with our dedicated image rotation and subtraction(IRS)technique and the optimized IRS(O-IRS)algorithm,the averaged contrast ratio for a 5≤V_(mag)≤9 primary star is 1.3×10^(-5)and3.3×10^(-6)at angular distance of 0.36"with exposure time of 7 minutes and 2 hours,respectively.PAO has successfully revealed the known exoplanet ofκAnd b in our recent observation with the 3.5-meter ARC telescope at Apache Point Observatory.We have performed the associated astrometry and photometry analysis of the recoveredκAnd b planet,which gives a projected separation of 0.98"±0.05",a position angle of 51.1°±0.5°and a mass of 10.15_(-1.255)^(+2.19) MJup.These results demonstrate that PAO can be used for direct imaging of exoplanets with medium-sized telescopes.展开更多
Non-Common Path Error(NCPE) is one of the factors that limit an Adaptive Optics(AO)system from delivering ultra-high performance. To correct the NCPE associated static aberration, we propose a simple but robust and hi...Non-Common Path Error(NCPE) is one of the factors that limit an Adaptive Optics(AO)system from delivering ultra-high performance. To correct the NCPE associated static aberration, we propose a simple but robust and high-performance pupil-plane based wavefront measurement and correction technique, which can copy a single-mode fiber generated perfect wavefront to the AO system via an iteration optimization process, and the NCPE can be effectively corrected by directly commanding the Deformable Mirror(DM) of the AO system. Compared with the previous focal-plane based approach that uses focal plane based Point Spread Function(PSF) for correction evaluation, the pupil-plane based approach can be reliably and rapidly converged to a global optimization result and provides better performance, in particular for an AO system with a large initial static wavefront error. This technique we proposed can be implemented in astronomical AO systems where extremely high performance is required.展开更多
We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compa...We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compared to available sensors.Quantitative phantom and interference measurements showed that both methods can be combined without reciprocal adverse effects.The direct localization of the optical sensor on MR images acquired with a T1-weighted echo sequence simplifies the co-registration of NIRI and MRI data.In addition,the optical sensor is simple to attach,which is crucial for measurements on vulnerable subjects.The fNIRI and T2^(*)-weighted fMRI data of a cerebral activation were simultaneously acquired proving the practicability of the setup.展开更多
In the past few years,Chinese astronomical community is actively testing astronomical sites for several new optical/infrared ground-based telescopes.These site testing campaigns conducted were mainly focused on fundam...In the past few years,Chinese astronomical community is actively testing astronomical sites for several new optical/infrared ground-based telescopes.These site testing campaigns conducted were mainly focused on fundamental performances of the sites,such as cloud coverage,seeing,temperature,etc.With increasing interests in sodium laser guide star adaptive optics for these new telescopes in the Chinese astronomical community,it is interesting to investigate the performance of the laser guide star at these sites,especially considering that the sodium laser guide star’s on-sky performance is significantly influenced by sites’local performances,such as geomagnetic field,sodium layer dynamics,density of air molecule,etc.In this paper,we studied sodium laser guide star’s performance of a 20 W class Quasi Continuous Wave(QCW)pulsed laser developed by TIPC with numerical simulation for five selected sites in China.展开更多
This study proposed a coarse-fine mixed model for describing the rail surface unevenness of an ultra-large fully steerable radio telescope(Qi Tai Telescope) with a diameter of 110 meters. The rail surface unevenness i...This study proposed a coarse-fine mixed model for describing the rail surface unevenness of an ultra-large fully steerable radio telescope(Qi Tai Telescope) with a diameter of 110 meters. The rail surface unevenness includes information on error arising from two different scales, i.e., the long-periodshort-change and the short-period-long-change. Consequently, in this study an idea of a mixed model was proposed, in which trigonometric and fractal functions were, respectively, used to describe information on error from two scales. Key parameters were determined by using the least squares method and the wavelet transform method, and finally, a specific mathematical expression of the model was obtained by optimization. To validate the effectiveness of the new modeling method, the mixed model was then used to describe the rails of the Green Bank Telescope, the Large Millimeter Telescope, and a radio telescope in Miyun, Beijing. A comparative study revealed that the maximum error was less than15%, thus the result was superior to those of existing modeling methods.展开更多
We constrain the host-star flux of the microlensing planet OGLE-2014-BLG-0676 Lb using adaptive optics(AO)images taken by the Magellan and Keck telescopes.We measure the flux of the light blended with the microlensed ...We constrain the host-star flux of the microlensing planet OGLE-2014-BLG-0676 Lb using adaptive optics(AO)images taken by the Magellan and Keck telescopes.We measure the flux of the light blended with the microlensed source to be K=16.79±0.04 mag and J=17.76±0.03 mag.Assuming that the blend is the lens star,we find that the host is a 0.73_(-0.29)^(+0.14)M_(⊙)star at a distance of2.67_(-1.41)^(+0.77)kpc,where the relatively large uncertainty in angular Einstein radius measurement is the major source of uncertainty.With mass of M_(p)=3.68_(-1.44)^(+0.69)M_J,the planet is likely a"super Jupiter"at a projected separation of r_(⊥)=4.53_(-2.50)^(+1.49)AU,and a degenerate model yields a similar M_p=3.73_(-1.47)^(+0.73)M_(J)at a closer separation of r_(⊥)=2.56_(-1.41)^(+0.84)AU.Our estimates are consistent with the previous Bayesian analysis based on a Galactic model.OGLE-2014-BLG-0676 Lb belongs to a sample of planets discovered in a"secondgeneration"planetary microlensing survey and we attempt to systematically constrain host properties of this sample with high-resolution imaging to study the distribution of planets.展开更多
文摘With the development of cutting-edge multi-object spectrographs,fiber positioners located in the focal plane are being scaled down in size,and miniature hollow-cup Permanent Magnet motors are now being considered as a suitable replacement for Faulhaber Precistep stepper motors.However,the small electrical time constant of such coreless motors poses a challenge,as the problem of severe commutation torque ripple in a fiber positioner running a position loop has been tricky.To overcome this challenge,it is advised to increase the Pulse Width Modulation(PWM)frequency as much as possible to mitigate the effects of the current fluctuation.This must be done while ensuring adequate resolution of the PWM generator.By employing a voltage open-loop field-oriented control based on a modulation frequency of 1 MHz,the drive current only costs 25 m A under a 3.3 V power supply.The sine degree of phase current is immaculate,and the repeat positioning accuracy can reach 2μm.Moreover,it is possible to further shrink the bill of devices and the layout area of the Printed Circuit Board,especially in sizesensitive applications.This device has been developed under the new generation of The Large Sky Area MultiObject Fiber Spectroscopic Telescope.
基金supported by the National Natural Science Foundation of China(Grant Nos.11827804,U2031210)。
文摘The portable adaptive optics(PAO)device is a low-cost and compact system,designed for 4-meter class telescopes that have no adaptive optics(AO)system,because of the physical space limitation at the Nasmyth or Cassegrain focus and the historically high cost of conventional AO.The initial scientific observations of the PAO are focused on the direct imaging of exoplanets and sub-stellar companions.This paper discusses the concept of PAO and the associated high-contrast imaging performance in our recent observational runs.PAO deliver a Strehl ratio better than 60%in H band under median seeing conditions of 1".Combined with our dedicated image rotation and subtraction(IRS)technique and the optimized IRS(O-IRS)algorithm,the averaged contrast ratio for a 5≤V_(mag)≤9 primary star is 1.3×10^(-5)and3.3×10^(-6)at angular distance of 0.36"with exposure time of 7 minutes and 2 hours,respectively.PAO has successfully revealed the known exoplanet ofκAnd b in our recent observation with the 3.5-meter ARC telescope at Apache Point Observatory.We have performed the associated astrometry and photometry analysis of the recoveredκAnd b planet,which gives a projected separation of 0.98"±0.05",a position angle of 51.1°±0.5°and a mass of 10.15_(-1.255)^(+2.19) MJup.These results demonstrate that PAO can be used for direct imaging of exoplanets with medium-sized telescopes.
文摘Non-Common Path Error(NCPE) is one of the factors that limit an Adaptive Optics(AO)system from delivering ultra-high performance. To correct the NCPE associated static aberration, we propose a simple but robust and high-performance pupil-plane based wavefront measurement and correction technique, which can copy a single-mode fiber generated perfect wavefront to the AO system via an iteration optimization process, and the NCPE can be effectively corrected by directly commanding the Deformable Mirror(DM) of the AO system. Compared with the previous focal-plane based approach that uses focal plane based Point Spread Function(PSF) for correction evaluation, the pupil-plane based approach can be reliably and rapidly converged to a global optimization result and provides better performance, in particular for an AO system with a large initial static wavefront error. This technique we proposed can be implemented in astronomical AO systems where extremely high performance is required.
基金The authors gratefully acknowledge the support of the Swiss National Foundation(National Research Programme NRP 57)and like to thank Andreas Metz for his dedication.We thank Klaas Enno Stephan for supporting this study and Philips Healthcare for technical andfinancial support.We like to address special thanks to Elisabeth Moore from Philips Healthcare for providing and answering questions about the MRI stability test postprocessing software,to Dennis Hueber from ISS Inc.for answering questions about the ISS OxiplexTSTM and to Cornelia Hagmann for proofreading the manuscript.
文摘We present a novel optical sensor to acquire simultaneously functional near-infrared imaging(fNIRI)and functional magnetic resonance imaging(fMRI)data with an improved handling and direct localization in the MRI compared to available sensors.Quantitative phantom and interference measurements showed that both methods can be combined without reciprocal adverse effects.The direct localization of the optical sensor on MR images acquired with a T1-weighted echo sequence simplifies the co-registration of NIRI and MRI data.In addition,the optical sensor is simple to attach,which is crucial for measurements on vulnerable subjects.The fNIRI and T2^(*)-weighted fMRI data of a cerebral activation were simultaneously acquired proving the practicability of the setup.
基金supported by the Operation,Maintenance and Upgrading Fund for Astronomical Telescopes and Facility Instruments,budgeted from the Ministry of Finance of China(MOF)and administrated by the Chinese Academy of Sciences(CAS)。
文摘In the past few years,Chinese astronomical community is actively testing astronomical sites for several new optical/infrared ground-based telescopes.These site testing campaigns conducted were mainly focused on fundamental performances of the sites,such as cloud coverage,seeing,temperature,etc.With increasing interests in sodium laser guide star adaptive optics for these new telescopes in the Chinese astronomical community,it is interesting to investigate the performance of the laser guide star at these sites,especially considering that the sodium laser guide star’s on-sky performance is significantly influenced by sites’local performances,such as geomagnetic field,sodium layer dynamics,density of air molecule,etc.In this paper,we studied sodium laser guide star’s performance of a 20 W class Quasi Continuous Wave(QCW)pulsed laser developed by TIPC with numerical simulation for five selected sites in China.
基金financial support from the National Natural Science Foundation of China (Grant Nos. 51305322, 51405364 and 51490660)
文摘This study proposed a coarse-fine mixed model for describing the rail surface unevenness of an ultra-large fully steerable radio telescope(Qi Tai Telescope) with a diameter of 110 meters. The rail surface unevenness includes information on error arising from two different scales, i.e., the long-periodshort-change and the short-period-long-change. Consequently, in this study an idea of a mixed model was proposed, in which trigonometric and fractal functions were, respectively, used to describe information on error from two scales. Key parameters were determined by using the least squares method and the wavelet transform method, and finally, a specific mathematical expression of the model was obtained by optimization. To validate the effectiveness of the new modeling method, the mixed model was then used to describe the rails of the Green Bank Telescope, the Large Millimeter Telescope, and a radio telescope in Miyun, Beijing. A comparative study revealed that the maximum error was less than15%, thus the result was superior to those of existing modeling methods.
基金the support by National Key R&D Program of China(No.2019YFA0405100)the China Manned Space Project with NO.CMS-CSST-2021-A11 and+6 种基金Project 11573003 supported by the National Natural Science Foundation of China(NSFC)supported by a NASA Keck PI Data Awardpossible by the generous financial support of the W.M.Keck Foundationfunding from the National Science Centre,Poland,grant MAESTRO 2014/14/A/ST9/00121 to AUthe financial support of the ANR COLD WORLDS(ANR-18-CE31-0002)supported by the NASA Exoplanets Research Program(XRP)by cooperative agreement NNX16AD44Gsupported by the University of Tasmania through the UTAS Foundation and the endowed Warren Chair in Astronomy。
文摘We constrain the host-star flux of the microlensing planet OGLE-2014-BLG-0676 Lb using adaptive optics(AO)images taken by the Magellan and Keck telescopes.We measure the flux of the light blended with the microlensed source to be K=16.79±0.04 mag and J=17.76±0.03 mag.Assuming that the blend is the lens star,we find that the host is a 0.73_(-0.29)^(+0.14)M_(⊙)star at a distance of2.67_(-1.41)^(+0.77)kpc,where the relatively large uncertainty in angular Einstein radius measurement is the major source of uncertainty.With mass of M_(p)=3.68_(-1.44)^(+0.69)M_J,the planet is likely a"super Jupiter"at a projected separation of r_(⊥)=4.53_(-2.50)^(+1.49)AU,and a degenerate model yields a similar M_p=3.73_(-1.47)^(+0.73)M_(J)at a closer separation of r_(⊥)=2.56_(-1.41)^(+0.84)AU.Our estimates are consistent with the previous Bayesian analysis based on a Galactic model.OGLE-2014-BLG-0676 Lb belongs to a sample of planets discovered in a"secondgeneration"planetary microlensing survey and we attempt to systematically constrain host properties of this sample with high-resolution imaging to study the distribution of planets.