To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected...To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.展开更多
A conventional multi-channel pulse amplitude analyzer acquires single energy spectrum,but provides no information on its tendency with time.To address the limitation,we propose a scheme of time-sharing multichannel pu...A conventional multi-channel pulse amplitude analyzer acquires single energy spectrum,but provides no information on its tendency with time.To address the limitation,we propose a scheme of time-sharing multichannel pulse amplitude analyzer(TSMCA).A dual-port random access memory is divided into two storage spaces,one for current energy spectrum data acquisition and another for previous energy spectrum data storage.The two tasks can be performed simultaneously,and the time-related variation tendency of energy spectrum can be obtained.A prototype system of TSMCA is designed.It performs nicely,with maximum channel number of 4096 in capacity of 2^(32)/Ch,minimal time-sharing slice of 25 ms,the differential nonlinearity of <1.5%,and the integral nonlinearity of <0.3%.展开更多
A multi-channel retarding field analyzer(MC-RFA) including two RFA modules and two Langmuir probes to measure the ion and electron temperature profiles within the scrape-off layer was developed for investigations of...A multi-channel retarding field analyzer(MC-RFA) including two RFA modules and two Langmuir probes to measure the ion and electron temperature profiles within the scrape-off layer was developed for investigations of the interplay between magnetic topology and plasma transport at the plasma boundary.The MC-RFA probe for the stellarator W7-X and first measurements at the tokamak EAST was designed.The probe head allows simultaneous multichannel ion temperature as well as for electron temperature measurements.The usability for radial correlation measurements of the measured ion currents is also given.展开更多
The system of Integrated-Optics Acousto-Optic RF Spectrum Analyzer (IOAOSA)consists of a laser diode, an Acousto-Optic (A-O) modulator, geodesic lenses and CCD detectorarray. The optical signal projected on the CCD ar...The system of Integrated-Optics Acousto-Optic RF Spectrum Analyzer (IOAOSA)consists of a laser diode, an Acousto-Optic (A-O) modulator, geodesic lenses and CCD detectorarray. The optical signal projected on the CCD array is converted into electrical signal andprocessed by the signal processing center which consists of a TMS 32010 system and an IBM-PC.The TMS 32010 with very high speed is used in a microcomputer system. A cycle sample methodis adopted to collect the data of the CCD video signal, sampling one per 40-point. After theprocessing, the frequency bandwidth, the resolution and the dynamic range of the system aremeasured to be 100 MHz, 8 MHz and 20 dB, respectively.展开更多
The outstanding properties of CVD diamond film such as electronic, optical, thermal and mechanical and the high radiation hardness have made it an ideal candidate material for radiation detectors in severe environment...The outstanding properties of CVD diamond film such as electronic, optical, thermal and mechanical and the high radiation hardness have made it an ideal candidate material for radiation detectors in severe environments. Fabrication of 'detector grade' CVD diamond films and development of CVD diamond detectors have been leading edge subjects. Micro-strip gas chamber (MSGC) fabricated on CVD diamond substrate would overcome the charge-up effect and the substrate instability, which has been a hotspot in the research of gas detectors.展开更多
In a recent previous work, we proposed a rotating polarizer-analyzer ellipsometer (RPAE) in which the two elements are rotating synchronously in the same direction with a speed ratio 1:3. We applied this technique to ...In a recent previous work, we proposed a rotating polarizer-analyzer ellipsometer (RPAE) in which the two elements are rotating synchronously in the same direction with a speed ratio 1:3. We applied this technique to bulk samples. In this work, we present theoretically the characterization of 100 nm SiO2 thin film using this spectroscopic RPAE. We assume a structure consisting of air (ambient)/SiO2 (thin film)/c-Si (substrate). The ellipsometric parameters ψ and Δ are calculated when a clean signal is received by the detector and when a hypothetical noise is imposed on this signal. The film thickness and the optical constants of the film are calculated for the noisy signal in the spectrum range 200 - 800 nm. The results are compared with the proposed thickness and with the accepted values for SiO2 optical constants.展开更多
Characteristics of atmospheric carbonaceous aerosols in Lanzhou City from December 2014 to November 2015 are analyzed using a multiwavelength thermal/optical carbon analyzer. Results reveal that average concentrations...Characteristics of atmospheric carbonaceous aerosols in Lanzhou City from December 2014 to November 2015 are analyzed using a multiwavelength thermal/optical carbon analyzer. Results reveal that average concentrations of black carbon (BC) and organic carbon in atmospheric aerosols at Lanzhou are 6.7 and 25.4 μg m^(-3), respectively, showing obvious seasonality (higher in winter and lower in summer). This is consistent with findings in cities of northern China. Primary organic aerosols and secondary organic aerosols respectively account for approximately 60% and 17% of carbonaceous aerosols. No significant seasonality is found for secondary organic carbon, indicating that its potential sources do not vary significantly throughout the study period. The mass absorption cross-section (MAC_(632nm)) of BC is 7.1 m^2g^(-1), slightly higher than that of immediately emitted BC. MAC values of BC at different wavelengths vary drastically; they are higher for ultraviolet and visible light (8.5–10.2 m^2g^(-1)) than for near-infrared light (4.9–5.7 m^2g^(-1)). The aerosol absorption optical depth generally declines from the near-infrared to the near-ultraviolet region. The values are higher in winter than in summer, thus showing there are different contributions of BC deposition in different seasons. Brown carbon (BrC) has an ?ngstr?m absorption exponent (AAE) value of approximately 2.75, which is similar to the AAE value of BrC generated by diesel combustion (2.3). The contribution of BrC to light absorption is as much as 34% at a wavelength of 635 nm. This study demonstrates that the multiwavelength thermal/optical carbon analyzer can quantify absorption properties of BrC in atmospheric aerosols. This can enhance understanding of carbonaceous aerosols and provide key parameters for simulations of climate models.展开更多
The recent advances on the research and the applications of the integrated optics acousto-optic spectrum analyzer(IOSA) are reviewed. The operating principle, architecture, characteristics and technology, and future d...The recent advances on the research and the applications of the integrated optics acousto-optic spectrum analyzer(IOSA) are reviewed. The operating principle, architecture, characteristics and technology, and future development of the different receivers are described.展开更多
In order to realize laser frequency stabilization,the global evolution of an analyzer angle on the electrodeless-discharge-vaporlamp-based excited-state Faraday anomalous dispersion optical filter(LESFADOF)with a sing...In order to realize laser frequency stabilization,the global evolution of an analyzer angle on the electrodeless-discharge-vaporlamp-based excited-state Faraday anomalous dispersion optical filter(LESFADOF)with a single transmission peak operating on the Rb1529 nm(5P3/2-4D5/2)is presented.We find that the transmission of the line center peak at 80°arrives at 14%in a 3 cm length lamp contained natural Rb mixed with 2 torr Xe buffer gas operating at 250°C with 176 MHz radio frequency.When it is used to realize laser frequency stabilization,the LESFADOF at near 80°is appropriate.Whether a single transmission peak or double transmission peaks depend on the rf voltage when two polarizers are crossed.展开更多
文摘To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.
基金supported by the National Natural Science Foundation of China(Nos.11375195,11375263,and 11105143)the project of National Magnetic Confinement Fusion Energy Development Research(No.2013GB104003)
文摘A conventional multi-channel pulse amplitude analyzer acquires single energy spectrum,but provides no information on its tendency with time.To address the limitation,we propose a scheme of time-sharing multichannel pulse amplitude analyzer(TSMCA).A dual-port random access memory is divided into two storage spaces,one for current energy spectrum data acquisition and another for previous energy spectrum data storage.The two tasks can be performed simultaneously,and the time-related variation tendency of energy spectrum can be obtained.A prototype system of TSMCA is designed.It performs nicely,with maximum channel number of 4096 in capacity of 2^(32)/Ch,minimal time-sharing slice of 25 ms,the differential nonlinearity of <1.5%,and the integral nonlinearity of <0.3%.
基金funding from the Euratom research and training programme 2014–2018 under grant agreement No.633053supported by the National Magnetic Confinement Fusion Science Program of China under Contracts No.20113GB106003
文摘A multi-channel retarding field analyzer(MC-RFA) including two RFA modules and two Langmuir probes to measure the ion and electron temperature profiles within the scrape-off layer was developed for investigations of the interplay between magnetic topology and plasma transport at the plasma boundary.The MC-RFA probe for the stellarator W7-X and first measurements at the tokamak EAST was designed.The probe head allows simultaneous multichannel ion temperature as well as for electron temperature measurements.The usability for radial correlation measurements of the measured ion currents is also given.
基金Supported by National "863" High Technology Plans of China
文摘The system of Integrated-Optics Acousto-Optic RF Spectrum Analyzer (IOAOSA)consists of a laser diode, an Acousto-Optic (A-O) modulator, geodesic lenses and CCD detectorarray. The optical signal projected on the CCD array is converted into electrical signal andprocessed by the signal processing center which consists of a TMS 32010 system and an IBM-PC.The TMS 32010 with very high speed is used in a microcomputer system. A cycle sample methodis adopted to collect the data of the CCD video signal, sampling one per 40-point. After theprocessing, the frequency bandwidth, the resolution and the dynamic range of the system aremeasured to be 100 MHz, 8 MHz and 20 dB, respectively.
文摘The outstanding properties of CVD diamond film such as electronic, optical, thermal and mechanical and the high radiation hardness have made it an ideal candidate material for radiation detectors in severe environments. Fabrication of 'detector grade' CVD diamond films and development of CVD diamond detectors have been leading edge subjects. Micro-strip gas chamber (MSGC) fabricated on CVD diamond substrate would overcome the charge-up effect and the substrate instability, which has been a hotspot in the research of gas detectors.
文摘In a recent previous work, we proposed a rotating polarizer-analyzer ellipsometer (RPAE) in which the two elements are rotating synchronously in the same direction with a speed ratio 1:3. We applied this technique to bulk samples. In this work, we present theoretically the characterization of 100 nm SiO2 thin film using this spectroscopic RPAE. We assume a structure consisting of air (ambient)/SiO2 (thin film)/c-Si (substrate). The ellipsometric parameters ψ and Δ are calculated when a clean signal is received by the detector and when a hypothetical noise is imposed on this signal. The film thickness and the optical constants of the film are calculated for the noisy signal in the spectrum range 200 - 800 nm. The results are compared with the proposed thickness and with the accepted values for SiO2 optical constants.
基金supported by the National Natural Science Foundation of China (Grant Nos. 41671067, 41630754)the Key Research Program of Frontier Sciences CAS (Grant No. QYZDJSSW-DQC039)+1 种基金the State Key Laboratory of Cryospheric Sciences, Chinese Academy of Sciences (Grant No. SKLCS-ZZ-2018)the Youth Talents Project of Northwest Institute of Environmental Resources, Chinese Academy of Sciences, China Scholarship Council Project
文摘Characteristics of atmospheric carbonaceous aerosols in Lanzhou City from December 2014 to November 2015 are analyzed using a multiwavelength thermal/optical carbon analyzer. Results reveal that average concentrations of black carbon (BC) and organic carbon in atmospheric aerosols at Lanzhou are 6.7 and 25.4 μg m^(-3), respectively, showing obvious seasonality (higher in winter and lower in summer). This is consistent with findings in cities of northern China. Primary organic aerosols and secondary organic aerosols respectively account for approximately 60% and 17% of carbonaceous aerosols. No significant seasonality is found for secondary organic carbon, indicating that its potential sources do not vary significantly throughout the study period. The mass absorption cross-section (MAC_(632nm)) of BC is 7.1 m^2g^(-1), slightly higher than that of immediately emitted BC. MAC values of BC at different wavelengths vary drastically; they are higher for ultraviolet and visible light (8.5–10.2 m^2g^(-1)) than for near-infrared light (4.9–5.7 m^2g^(-1)). The aerosol absorption optical depth generally declines from the near-infrared to the near-ultraviolet region. The values are higher in winter than in summer, thus showing there are different contributions of BC deposition in different seasons. Brown carbon (BrC) has an ?ngstr?m absorption exponent (AAE) value of approximately 2.75, which is similar to the AAE value of BrC generated by diesel combustion (2.3). The contribution of BrC to light absorption is as much as 34% at a wavelength of 635 nm. This study demonstrates that the multiwavelength thermal/optical carbon analyzer can quantify absorption properties of BrC in atmospheric aerosols. This can enhance understanding of carbonaceous aerosols and provide key parameters for simulations of climate models.
文摘The recent advances on the research and the applications of the integrated optics acousto-optic spectrum analyzer(IOSA) are reviewed. The operating principle, architecture, characteristics and technology, and future development of the different receivers are described.
基金supported by the National Natural Science Foundation of China(10874009 and 11074011)
文摘In order to realize laser frequency stabilization,the global evolution of an analyzer angle on the electrodeless-discharge-vaporlamp-based excited-state Faraday anomalous dispersion optical filter(LESFADOF)with a single transmission peak operating on the Rb1529 nm(5P3/2-4D5/2)is presented.We find that the transmission of the line center peak at 80°arrives at 14%in a 3 cm length lamp contained natural Rb mixed with 2 torr Xe buffer gas operating at 250°C with 176 MHz radio frequency.When it is used to realize laser frequency stabilization,the LESFADOF at near 80°is appropriate.Whether a single transmission peak or double transmission peaks depend on the rf voltage when two polarizers are crossed.