Analysis of influence of RF power and buffer gas pressure on sensitivity of optically pumped cesium magnetometer
1
作者 石荣晔 王延辉 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第10期206-212,共7页
A further study is conducted on two factors which respectively influence the sensitivity of optically pumped cesium magnetometer (CsOPM). The influence of radio frequency (RF) power and the buffer gas pressure on ... A further study is conducted on two factors which respectively influence the sensitivity of optically pumped cesium magnetometer (CsOPM). The influence of radio frequency (RF) power and the buffer gas pressure on the sensitivity is theoretically analyzed, and some properties are predicted. Based on the established measurement system and the visible Zeeman spectrum, not only is the real influence of these factors studied, but also, under our experimental condition, optimum parameters based on the measured curves are ascertained. The properties of these measured curves match the theoretical result very well. Our research attempts to provide theory reference to help magnetometer designers determine optimum parameters under certain conditions. 展开更多
关键词 optically pumped cesium magnetometer buffer gas pressure sensitivity
下载PDF
A laser pump-re-pump atomic magnetometer 被引量:2
2
作者 杨爱林 杨国卿 +2 位作者 蔡勋明 徐云飞 林强 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第12期177-181,共5页
We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the con... We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the conventional method using one radiation field, which is used not only as the probe beam but also as a pump beam, the additional re-pump beam can increase remarkably the amplitude of the signal. It is shown that the amplitude of the magnetic field resonance signal can increase more than 55% by using an additional re-pump beam, which makes the sensitivity of the magnetometer higher. Finally, we investigate the relation between amplitude of the signal and re-pump laser power, and calculate the atomic population in the trapping states with rate equations. 展开更多
关键词 atomic magnetometer optical pumping sensitivity
下载PDF
A dual-axis, high-sensitivity atomic magnetometer
3
作者 李茹杰 全伟 +4 位作者 范文峰 邢力 王卓 翟跃阳 房建成 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第12期196-200,共5页
Atomic magnetometer (AM) operated in a spin-exchange relaxation-free (SERF) regime features superior sensitivity and non-cryogenic operation, and thus is competitive with the best superconducting quantum interfere... Atomic magnetometer (AM) operated in a spin-exchange relaxation-free (SERF) regime features superior sensitivity and non-cryogenic operation, and thus is competitive with the best superconducting quantum interference devices. Previously, SERF AM with fT/Hz1/2 level sensitivity commonly acted as a single-axis sensor. Here we demonstrate a dual-axis SERF AM capable of simultaneously and independently detecting x-and y-field components with a sensitivity of 20 fT/Hz1/2. As there is no necessity to worry about the cross-talk effects arising from field modulations, the dual-axis scheme proposed here is of particular interest to AM array and hence the biomagnetic applications. 展开更多
关键词 optically pumped magnetometers multi-axis field measurements high-sensitivity field measurements polarized atoms
下载PDF
Measurement of T wave in magnetocardiography using tunnel magnetoresistance sensor
4
作者 陆知宏 纪帅 杨建中 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期5-10,共6页
Several critical clinical applications of magnetocardiography(MCG)involve its T wave.The T wave’s accuracy directly affects the diagnostic accuracy of MCG for ischemic heart disease and arrhythmogenic.Tunnel magnetor... Several critical clinical applications of magnetocardiography(MCG)involve its T wave.The T wave’s accuracy directly affects the diagnostic accuracy of MCG for ischemic heart disease and arrhythmogenic.Tunnel magnetoresistance(TMR)attracts attention as a new MCG measurement technique.However,the T waves measured by TMR are often drowned in noise.The accuracy of T waves needs to be discussed to determine the clinical value of MCG measured by TMR.This study uses an improved empirical mode decomposition(EMD)algorithm and averaging to eliminate the noise in the MCG measured by TMR.The MCG signals measured by TMR are compared with MCG measured by the optically pumped magnetometer(OPM)to judge its accuracy.Using the MCG measured by OPM as a reference,the relative errors in time and amplitude of the T wave measured by TMR are 3.4%and 1.8%,respectively.This is the first demonstration that TMR can accurately measure the time and amplitude of MCG T waves.The ability to provide reliable T wave data illustrates the significant clinical application value of TMR in MCG measurement. 展开更多
关键词 MAGNETOCARDIOGRAPHY tunnel magnetoresistance optically pumped magnetometer T wave detection
下载PDF
VCSEL frequency stabilization for optically pumped magnetometers 被引量:3
5
作者 闫业广 刘刚 +3 位作者 林海笑 尹凯峰 王锟 陆吉玺 《Chinese Optics Letters》 SCIE EI CAS CSCD 2021年第12期64-69,共6页
Optically pumped magnetometers(OPMs)have developed rapidly in the bio-magnetic measurement field,which requires lasers with stable frequency and intensity for high sensitivity.Herein we stabilize a vertical-cavity sur... Optically pumped magnetometers(OPMs)have developed rapidly in the bio-magnetic measurement field,which requires lasers with stable frequency and intensity for high sensitivity.Herein we stabilize a vertical-cavity surface-emitting laser(VCSEL)without any additional setup except for the parts of an OPM.The linewidth of the absorption spectrum as a frequency reference is broadened to 40 GHz owing to pressure broadening.To enhance performance,the VCSEL injection current and temperature are tuned simultaneously using a closed-loop control system.The experiments reveal that the VCSEL frequency stability achieves 2×10^(-7) at an average time of 1 s,and the intensity noise is 1×10^(-6)V/Hz^(1/2) at 1-100 Hz.This approach is useful for suppressing OPM noise without additional sensor probe parts. 展开更多
关键词 optically pumped magnetometer vertical-cavity surface-emitting laser single-closed-loop double-closed-loop
原文传递
Zero field optically pumped magnetometer with independent dual-mode operation 被引量:1
6
作者 张少文 陆吉玺 +5 位作者 周莹 逯斐 尹凯峰 詹迪 翟跃阳 叶茂 《Chinese Optics Letters》 SCIE EI CAS CSCD 2022年第8期18-23,共6页
We propose a dual-mode optically pumped magnetometer(OPM)that can flexibly switch between single-beam modulation mode and double-beam DC mode.Based on a 4 mm×4 mm×4 mm miniaturized vapor cell,the double-beam... We propose a dual-mode optically pumped magnetometer(OPM)that can flexibly switch between single-beam modulation mode and double-beam DC mode.Based on a 4 mm×4 mm×4 mm miniaturized vapor cell,the double-beam DC mode achieves a sensitivity of 7 fT=Hz^(1/2) with probe noise below 4 fT=Hz^(1/2) and working bandwidth over 65 Hz.This mode is designed to precisely measure the noise floor of a mu-metal magnetic shield.The single-beam modulation mode(sensitivity 20 fT=Hz^(1/2))exhibits bandwidth characteristics suitable for biomagnetic measurements.Thus,our design is suitable for a miniaturized OPM with multiple functions,including magnetic-shield background noise measurement and medical imaging. 展开更多
关键词 optically pumped magnetometer atomic optics dual-mode magnetometer MAGNETOENCEPHALOGRAPHY medical imaging