期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis 被引量:11
1
作者 Hong-Ting Liu Zhou Zhou +8 位作者 Wu-Qiang Luo Wen-Jing He Owhofasa Agbedia Jiang-Xia Wang Jian-Zhong Huang Xin Gao Min Kong Min Li Li Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第4期656-661,共6页
AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia... AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index(OSI), the values of modulation transfer function(MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System(OQAS) values(OVs) were accessed. The higher order aberrations(HOAs) data including coma, trefoil, spherical, 2^(nd) astigmatism and tetrafoil were also obtained. For patients with pupil size 〈6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded.RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent(P〈 0.001). After the ICL implantation, the OSI decreasedslightly from 2.34±1.92 to 2.24±1.18 with no statistical significance(P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively(Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mmpupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2^(nd) astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05,-0.04±0.04, 0.03±0.01 respectively(Wilcoxon signed ranks test, all P〈0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality. 展开更多
关键词 optical quality implantable collamer lens wavefront-guided laser in situ keratomileusis
下载PDF
Comparison of choroidal thickness in high myopic eyes after FS-LASIK versus implantable collamer lens implantation with swept-source optical coherence tomography 被引量:2
2
作者 Jing Zhang Fang-Lin He +1 位作者 Yan Liu Xian-Qun Fan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第5期773-781,共9页
AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation usin... AIM:To investigate the changes in choroidal thickness(CT)in high myopic eyes after femtosecond laser-assisted in situ keratomileusis(FS-LASIK)surgery or central hole implantable collamer lens(ICL V4c)implantation using swept-source optical coherence tomography(SS-OCT).METHODS:We examined the right eyes of 116 patients with high myopia who were candidates for FS-LASIK surgery and ICL implantation.Sixty eyes underwent ICL V4c implantation and 56 eyes were subjected to FS-LASIK surgery.The CT was measured with SS-OCT.All data were recorded preoperatively and 2 h,1 wk,1 and 3 mo postoperatively.Other demographic information was collected,including age,sex,uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),spherical equivalent(SE),intraocular pressure(IOP)and axial length(AL).RESULTS:The UCVA improved in both groups and showed no significant differences between groups.There also were no significant differences between the two groups in postoperative BCVA and SE(P=0.581 and 0.203,respectively).The foveal CTs,inner nasal and outer nasal CTs were significantly thicker at 2 h postoperatively in both groups(P<0.05)but returned to baseline levels in 1 wk;after 1 mo,no significant differences were found relative to the preoperative values.At 3 mo in each group,nine regions showed variations in the CT as compared with preoperative thickening,but only the foveal and nasal area CTs preoperative differences were statistically significant(P<0.05).In addition,there was no significant difference in 9 regions of CT between the two groups at all follow-up times(P>0.05).CONCLUSION:The CTs after ICL implantation and FSLASIK surgery are significantly thicker than those before operation,especially in the foveal and nasal areas,but there is no significant difference between the two methods. 展开更多
关键词 choroidal thickness high myopia laser in situ keratomileusis implantable collamer lens implantation swept-source optical coherence tomography
下载PDF
ICL与LASIK治疗角膜屈光术后屈光回退患者的效果比较
3
作者 张语洋 《中国民康医学》 2023年第14期152-154,共3页
目的:比较有晶体眼后房型人工晶体植入术(ICL)与准分子激光原位角膜磨镶术(LASIK)治疗角膜屈光术后屈光回退患者的效果。方法:回顾性分析2020年7月至2022年1月该院收治的60例角膜屈光术后屈光回退患者的临床资料,按照手术方式不同将其... 目的:比较有晶体眼后房型人工晶体植入术(ICL)与准分子激光原位角膜磨镶术(LASIK)治疗角膜屈光术后屈光回退患者的效果。方法:回顾性分析2020年7月至2022年1月该院收治的60例角膜屈光术后屈光回退患者的临床资料,按照手术方式不同将其分为观察组和对照组各30例。对照组行LASIK治疗,观察组行ICL治疗,术后均随访3个月。比较两组临床疗效,术前和术后3个月裸眼视力、屈光度、视觉质量指标[客观视觉质量指数量化(MTF截止频率)、斯特列尔比(SR)、客观散射指数(OSI)]水平,以及并发症发生率。结果:观察组治疗总有效率为90.00%(27/30),高于对照组的66.67%(20/30),差异有统计学意义(P<0.05);观察组裸眼视力、MTF截止频率、SR水平均高于对照组,OSI水平低于对照组,差异有统计学意义(P<0.05);观察组并发症发生率为6.67%(2/30),低于对照组的26.67%(8/30),差异有统计学意义(P<0.05);两组屈光度水平比较,差异无统计学意义(P>0.05)。结论:ICL治疗角膜屈光术后屈光回退患者可提高治疗总有效率和裸眼视力水平,改善视觉质量指标水平,降低并发症发生率,效果优于LASIK治疗。 展开更多
关键词 有晶体眼后房型人工晶体植入术 准分子激光原位角膜磨镶术 角膜屈光术 屈光回退 裸眼视力 视觉质量 并发症
下载PDF
有晶状体后房型人工晶状体植入术与飞秒激光LASIK术后视觉质量的比较 被引量:13
4
作者 王瑞娜 郭红亮 +2 位作者 马挺 梁厚成 龙潭 《中华实验眼科杂志》 CAS CSCD 北大核心 2017年第9期833-837,共5页
背景随着近视患病率的增加,近视患者如何选择合适的矫正方法以达到更好的视觉质量成为研究热点。目的采用双通道视觉质量分析仪(OQAS)对有晶状体眼后房型人工晶状体(ICL)植入术治疗中高度近视的效果和视觉质量与飞秒激光准分子激... 背景随着近视患病率的增加,近视患者如何选择合适的矫正方法以达到更好的视觉质量成为研究热点。目的采用双通道视觉质量分析仪(OQAS)对有晶状体眼后房型人工晶状体(ICL)植入术治疗中高度近视的效果和视觉质量与飞秒激光准分子激光角膜原位磨镶术(FS—LASIK)进行对比分析。方法采用非随机临床对照研究设计,于2015年1月至2016年1月在西安市第一医院纳入屈光度为-4.00- -9.00D且拟行近视矫正手术者26例52眼,按照角膜厚度分为ICL植入术组和FS—LASIK组,角膜厚度〈500μm者12例24眼接受ICL植入术,角膜厚度≥500μm的14例28眼接受FS—LASIK手术,2个组间年龄、性别、术前最佳矫正远视力(BCDVA)和术前等效球镜度(SE)的差异均无统计学意义(均P〉0.05)。所有患者随访至术后3个月,对2个组术眼术后裸眼远视力(UCDVA)、SE、OQAS测量的调制传递函数截止频率(MTF cut off)、客观散射指数(OSI)、斯特列尔(Strehl)比率及对比度100%、20%、9%时的对比度视力(OV100、OV20、OV9)进行比较,并对各自组内术眼手术后UCDVA与术前BCDVA进行比较。结果ICL组和FS.LASIK组术眼术后BCDVA均优于术前UCDVA(-0.04±0.10与0.05±0.12;-0.07±0.12与0.00±0.12),但差异均无统计学意义(t=3.128、2.358,均P〉0.05)。2个组间术眼术后SE、UCDVA和BCDVA的差异均无统计学意义(t=1.292、0.900、-0.653,均P〉0.05)。OQAS测量结果显示,2个组间术后MTF cut off、OSI、Strehl比和OV100值差异均无统计学意义(t=-2.032、-1.440、-0.224,均P〉0.05)。ICL组术眼术后OV20和OV9值分别为0.82±0.14和0.80±0.21,均明显高于FS—LASIK组的0.59±0.15和0.47±0.13,差异均有统计学意义(t=4.105、4.702,均P〈0,05)。结论]CL植入术和FS—LASIK矫正中高度近视均可有效改善患者的视力和屈光度,在20%和9%的对比度下,ICL术眼术后的视觉质量优于FS—LASIK。 展开更多
关键词 近视/手术 屈光手术 有晶状体眼人工晶状体 准分子激光角膜原位磨镶术 视觉质量 有晶状体眼后房型人工晶状体 双通道视觉质量分析仪
下载PDF
有晶状体眼后房型人工晶状体植入与FS-LASIK术后视觉质量分析 被引量:9
5
作者 马春霞 李文静 +4 位作者 蔡岩 王慧娴 邓月 马高阳 高晓唯 《国际眼科杂志》 CAS 北大核心 2019年第8期1305-1308,共4页
目的:比较有晶状体眼后房型人工晶状体(ICL)植入与FS-LASIK术治疗中高度近视术后的视觉质量。方法:前瞻性研究。选取2018-06/12分别行ICL植入术和FS-LASIK术的近视患者58例116眼(ICL组)和48例96眼(FS-LASIK组)。分析比较两组患者手术前... 目的:比较有晶状体眼后房型人工晶状体(ICL)植入与FS-LASIK术治疗中高度近视术后的视觉质量。方法:前瞻性研究。选取2018-06/12分别行ICL植入术和FS-LASIK术的近视患者58例116眼(ICL组)和48例96眼(FS-LASIK组)。分析比较两组患者手术前后屈光度、视力和视觉质量情况。结果:术后3mo,ICL组患者球镜度数高于FS-LASIK组(0.19±0.22D vs 0.09±0.29D,P<0.05),但两组患者视力、柱镜度数和等效球镜度数无差异(均P>0.05);ICL组患者调制传递函数截止频率(MTF cut off)、客观散射指数(OSI)和OV9%均明显优于FS-LASIK组,而SR较FS-LASIK组降低,且与术前相比,ICL组患者MTF cut off明显增高,SR、OSI值降低,FS-LASIK组患者SR值降低(均P<0.05)。结论:ICL植入和FS-LASIK术均可有效改善患者视力和屈光度,对于中高度近视患者ICL植入术可提供相对较好的视觉质量。 展开更多
关键词 有晶状体眼后房型人工晶状体植入术 高度近视 飞秒激光 准分子激光原位角膜磨镶术 双通道视觉质量分析系统 视觉质量
下载PDF
高度近视ICL植入术和飞秒激光制瓣LASIK术后视觉质量的比较 被引量:7
6
作者 赵宏 李彩红 +2 位作者 沈策英 赵晓金 朴勇虎 《中华眼外伤职业眼病杂志》 2017年第11期801-806,共6页
目的比较高度近视有晶状体眼人工晶状体(ICL)植入术与飞秒激光辅助制瓣的准分子激光原位角膜磨镶术(FS-LASIK)术后的视觉质量。方法回顾性分析屈光手术91例(182只眼)的临床资料。随机分成两组,ICL组:后房型ICL植入术39例(78只... 目的比较高度近视有晶状体眼人工晶状体(ICL)植入术与飞秒激光辅助制瓣的准分子激光原位角膜磨镶术(FS-LASIK)术后的视觉质量。方法回顾性分析屈光手术91例(182只眼)的临床资料。随机分成两组,ICL组:后房型ICL植入术39例(78只眼);LASIK组:FS-LASIK手术52例(104只眼)。对比分析两组术后的视觉质量。结果术后1、3及6个月的安全性指数两组间差异无统计学意义(P=1.000,0.373,0.230);术后3个月、6个月的有效性指数两组间差异有统计学意义(P=0.000,0.000);两组术后3个月、6个月的屈光度两组间差异有统计学意义(P=0.042,0.002);ICL组术后6个月总高阶像差、球差及彗差的升高幅度均低于FS—LASIK组(P=0.000,0.000,0.001)。术后6个月明视下1.5cpd、3.0cpd和6.0cpd空间频率对比敏感度两组差异无统计学意义(P=0.576,0.659,0.840),12.0cpd和18.0cpd空间频率ICL组较LASIK组高,差异有统计学意义(P=0.000,0.000);暗视下各空间频率对比敏感度ICL组均较LASIK组高,差异有统计学意义(P=0.000,0.000,0.000,0.000,0.000)。结论ICL术后长期裸眼视力和屈光状态较稳定,术后高阶像差增加较少,对比敏感度在各个空间频率均提高,术后视觉质量明显优于FS-LASIK组。ICL手术是矫正高度近视的一种预测性强、安全性高和稳定性好的手术方式。 展开更多
关键词 晶状体 人工 有晶状体眼 后房型 胶原聚合体透镜 可植入 准分子激光原位角膜磨镶术 飞秒激光制瓣 近视 高度 视觉质量
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部