Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary ...Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary electrochromatography by the in situ polymerization of sodium p-styrene sulfonate(VBS)with cross-linkers 3-(acryloyloxy)-2-hydroxypropyl methacrylate(AHM)and 1,3,5-triacryloylhexahydro-1,3,5-triazine(TAT).The preparation conditions of the monolith were optimized.The morphology and formation of the poly(VBS-co-TAT-co-AHM)monolith were confirmed by scanning electron microscopy(SEM)and Fourier transform infrared spectroscopy(FT-IR).The separation perfor-mances of the monolith were evaluated systematically.It should be noted that the incorporation of VBS functional monomer can provideπ-πinteractions,hydrophilic interactions,and ion-exchange in-teractions.Hence,the prepared poly(VBS-co-TAT-co-AHM)monolith can achieve efficient separation of thiourea compounds,benzene series,phenol compounds,aniline compounds and sulfonamides in RPLC or HILIC separation mode.The largest theoretical plate number for N,N0-dimethylthiourea reached 1.7×10^(5)plates/m.In addition,the poly(VBS-co-TAT-co-AHM)monolithic column showed excellent reproducibility and stability.This novel monolithic column has great application value and potential in capillary electrochromatography(CEC).展开更多
Molecularly imprinted polymers (MIPs), using (S)-naproxen as template and the combination of butyl methacrylate (BMA) and MAA (1:1 molar ratio) as functional monomers were synthesized by an in situ polymeriza...Molecularly imprinted polymers (MIPs), using (S)-naproxen as template and the combination of butyl methacrylate (BMA) and MAA (1:1 molar ratio) as functional monomers were synthesized by an in situ polymerization reaction. The rendered monolithic column was evaluated in HPLC mode. The result showed that the monolithic MIPs with the combination of two monomers produced better chiral resolution of rac-naproxen (Rs = 1.55) and column efficiencies of imprinted molecules (N = 2860 plates/m) than that with pure MAA.展开更多
Fritless packed silica gel columns were prepared using sol-gel technology, The part of a 75 μm i.d. capillary was filled with a mixture of methacryloxypropyltrimethoxysilane, toluene and hydrochloric acid. Four diffe...Fritless packed silica gel columns were prepared using sol-gel technology, The part of a 75 μm i.d. capillary was filled with a mixture of methacryloxypropyltrimethoxysilane, toluene and hydrochloric acid. Four different photoinitiators such as benzoin methyl ether, Irgacure 819, Irgacure 1700 and Irgacure 1800 were added in the presence or absence of sodium dodecyl sulfate during the polymerization process. The above eight solutions were irradiated at 365 nm about 5-10 min to prepare the porous monolithic sol-gel columns by a one-step process.展开更多
To make more homogenous organic monolithic structure, reversible addition-fragmentation chain transfer (RAFT) process was employed in the synthesis of the clenbuterol imprinted polymer. In the synthesis, the influen...To make more homogenous organic monolithic structure, reversible addition-fragmentation chain transfer (RAFT) process was employed in the synthesis of the clenbuterol imprinted polymer. In the synthesis, the influence of synthetic conditions on the polymer structure and separation efficiency was studied. The result demonstrated that the imprinted columns prepared with RAFT process have higher column efficiency and selectivity than the columns prepared with conventional polymerization in the present study, which may result from the higher surface area, smaller pore size and the narrower globule size distribution in their structures. The result indicated that RAFT polymerization provided better conditions for the clenbuterol imprinted monolithic polymer preparation. 2009 Xiang Chao Dong. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.展开更多
Monolithic silica spin column extraction (MonoSpin-SPE) was developed as a simple, sensitive, and eco-friendly pretreatment method which combined with ultra-fast liquid chromatography-mass spectrometry (UFLC-MS) t...Monolithic silica spin column extraction (MonoSpin-SPE) was developed as a simple, sensitive, and eco-friendly pretreatment method which combined with ultra-fast liquid chromatography-mass spectrometry (UFLC-MS) to determine the levels of six phthalate esters, dimethyl- (DMP), diethyl- (DEP), dipropyl- [ DPrP], butyl-benzyl- (BBP), dicyclohexyl- (DcHP), and di-n-octyl-(DOP) phthalate in physiological saline samples. Under optimized experimental conditions, the method was linear in the following ranges: 0.2- 50 μg/L for DMP, DEP, DPrP, DcHP and DOP; 5- 100 μg/L for BBP. The correlation coefficients (R2 ) were in the range of 0. 9951 - 0. 9995 for all the analytes and the limits of detection (LODs) and limits of quantification (LOQs) were in the ranges of 0.02 - 0.9 μg/L and 0.08 - 2.7μg/L, respectively. The pretreatment process showed good reproducibility with inter-day and intra-day relative standard deviations (RSDs) below 8.5% and 11.2%, respectively. This method was used to determine the levels of six phthalate esters in physiological saline samples and the recoveries ranged from 71.2% to 107.3%. DMP and DEP were found in actual physical saline samples (brand A and brand B).展开更多
Microwave irradiation was firstly attempted for the preparation of organic-based monoliths of poly(styrene-divinylbenzene- methacrylic acid), which single step in situ polymerization was carried out during 15 min. T...Microwave irradiation was firstly attempted for the preparation of organic-based monoliths of poly(styrene-divinylbenzene- methacrylic acid), which single step in situ polymerization was carried out during 15 min. The colunm permeability, electrophoretic and chromatographac behaviors were comparatively evaluated using pressure-assisted CEC, GEC and low pressure-driven separation modes. The largest theoretical plates for the preparing column could be close to 18,0000 plates/m for thiourea in the mode of p-CEC. It provided a viable alternative to traditional initiation means for the perparation of monolithic capillary columns.展开更多
A monolithic molecularly imprinted polymer with specific recognition ability for 4-hydroxybenzoic acid (4-HBA) was prepared by in situ photopolymerization, using methacrylic acid (MAA) as a functional monomer, ethylen...A monolithic molecularly imprinted polymer with specific recognition ability for 4-hydroxybenzoic acid (4-HBA) was prepared by in situ photopolymerization, using methacrylic acid (MAA) as a functional monomer, ethylene glycol dimethacrylate (EDMA) as a cross-linking agent, toluene and isooctane as porogenic solvents and Irgacure 1800 as an initiator. Baseline separation of isomers of hydroxybenzoic acid was achieved in less than 8 min on this monolithic column using 4-HBA as template, but not on the blank polymer. Furthermore, some neutral compounds could also be baseline-separated on the imprinted polymer column in the mode of pressure-driven capillary electrochromatography.展开更多
An analytical methodology based on an O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-dihydroquinidine(MQD)-silica hybrid monolithic column was developed for the enantioseparation of 9-fluorenylmethoxycarbonyl(FMOC)deriv...An analytical methodology based on an O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-dihydroquinidine(MQD)-silica hybrid monolithic column was developed for the enantioseparation of 9-fluorenylmethoxycarbonyl(FMOC)derivatized amino acids by nano-liquid chromatography.The mobile phase was optimized including the apparent pH,content of ACN,and concentration of the buffer to obtain a satisfactory enantioresolution performance.27 FMOC derivatized amino acids including 19 protein and 8 non-protein amino acids were tested,and 19 out of them were enantiomerically discriminated obtaining baseline separation for 11 of them.Analytical characteristics of the method were evaluated for norvaline and tryptophan in terms of linearity,precision,accuracy,limits of detection(LOD)and quantitation(LOQ)showing good performance to be applied to the enantiomeric determination of these amino acids in dietary supplements.LOD and LOQ values were 9.3 and 31 mM for norvaline enantiomers and 7.5 and 25 mM for tryptophan enantiomers,respectively.The contents of D-norvaline and D-tryptophan were below their respective LODs in all the analyzed samples.Quantitation of L-tryptophan and L-norvaline showed good agreement with the labeled contents except for one sample which did not show presence of L-norvaline,contrary to the label indication.展开更多
Methacrylate-based monolithic column was prepared in fused-silica capillary (80 ′ 0.32 mm i.d.) by in situ polymerizetion reaction using glycidyl methacrylate as monomer;ethylene dimethacrylate as crosslinker;1-propa...Methacrylate-based monolithic column was prepared in fused-silica capillary (80 ′ 0.32 mm i.d.) by in situ polymerizetion reaction using glycidyl methacrylate as monomer;ethylene dimethacrylate as crosslinker;1-propanol, 1,4-butanediol, and water as porogenic solvents. The monolith matrix was modified with trimethylamine to create strong anion exchanger via ring opening reaction of epoxy groups. The morphology of the monolithic column was studied by using Scanning Electron Microscope (SEM). This column had good mechanical stability and permeability. The effects of various mobile phases for separation of inorganic anions were investigated. Iodate, bromate, nitrite, bromide, and nitrate were separated within 11 min using100 mMpotassium chloride as mobile phase and detected at 210 nm. This method showed good precision of retention time, acceptable linearity and good sensitivity. Under the optimum condition, the RSD of the retention time was in the range of 1.09%-1.75% (n = 6). The calibration curve showed linear relationships between the peak area and the concentration. The limits of detection (LOD) and the limits of quantitation (LOQ) were between 0.08-0.18 mM and 0.26-0.61 mM, respectively. This method was applied to the determination of inorganic anions in tap water and ground water samples.展开更多
A porous monolithic sol-gel column with the solution of methacryloxypropyltrimethoxysilane in toluene with an acid catalyst was prepared in the presence and absence of sodium dodecyl sulfate. In situ polymerization wa...A porous monolithic sol-gel column with the solution of methacryloxypropyltrimethoxysilane in toluene with an acid catalyst was prepared in the presence and absence of sodium dodecyl sulfate. In situ polymerization was carded out by γ-ray irradiation within the capillary. The γ-radiation-initiated synthesis could generate radicals directly on the monomer avoiding use of any initiator. The chromatographic behavior of the capillary monolithic columns were studied in the modes of CEC, p-CEC and low pressure-driven separation, all the tests exhibited reversed-phase character. It provided a viable alternative to either thermally initiated or photo polymerization method for the preparation of monolithic columns.展开更多
A novel monolithic stationary phase having long alkyl chain ligands was introduced and evaluated in pressurized-capillary electrochromatography of small neutral and charged compounds. The monolithic column was prepare...A novel monolithic stationary phase having long alkyl chain ligands was introduced and evaluated in pressurized-capillary electrochromatography of small neutral and charged compounds. The monolithic column was prepared by the in situ copolymerization of ethylene dimethacrylate, 1-hexadecene, allyl alcohol and 2-acrylamido-2-methyl-1-propanesulfonic acid in a quaternary porogenic solvent mixture consisting of 1, 4-butanediol, cyclohexanol, dodecanol and water.展开更多
Photopolymerized sol-gel(PSG) columns were prepared using methacryloxypropyltrimethoxysilane as the monomer,toluene as the porogen and hydrochloric acid as the catalyst.Four different photoinitiators such as benzoin m...Photopolymerized sol-gel(PSG) columns were prepared using methacryloxypropyltrimethoxysilane as the monomer,toluene as the porogen and hydrochloric acid as the catalyst.Four different photoinitiators such as benzoin methyl ether,Irgacure 819,Irgacure 1700 and Irgacure 1800 were comparatively used in the reaction solution in the presence and absence of sodium dodecyl sulfate.The above eight solutions were respectively irradiated at 365 nm for 5?10 min in each capillary(75 μm inside diameter) to prepare the porous monolithic sol-gel column by a one-step,in situ,process.The chromatographic behavior of the eight PSG columns were comparatively studied,all of which exhibit reversed-phase character.Using these columns,several neutral compounds,namely thiourea,benzene,toluene,ethyl benzene,biphenyl and naphthalene can be separated from mixtures with a largest column efficiency of 74 470 plate/column for thiourea.Addition of sodium dodecyl sulfate in the polymerization process has a significant influence on the morphology and migration time.展开更多
Silica-based monolithic column material was synthesized and an enrichment device was fabricated with the material by assembling the material inside a glass column. The enrichment device was applied for the determinati...Silica-based monolithic column material was synthesized and an enrichment device was fabricated with the material by assembling the material inside a glass column. The enrichment device was applied for the determination of micro-carbaryl with near-infrared spectroscopy (NIRS). The aqueous solutions of carbaryl passed through the device and the carbaryl was enriched on the surface of the material where diffuse reflection NIR spectra were measured. These procedures of enrichment and measurement ensured to concentrate analytes for the measurement, so that the sensitivity of determination of MRS could be improved. NIR spectra of carbaryl solutions (0.01-1.00μg mL^-1), measured after the application of the enrichment device, were pretreated with multiplicative scatter correction (MSC) and regressed against the concentrations of the carbaryl solutions with partial least squares (PLS) method. The results showed that the minimum value of root-mean-square error of prediction (RMSEP) was 0.1771 μg mL^-1 when the number of latent variables was 3 of PLS regression. Therefore, the number of latent variables 3 was selected as the optimum value. RMSEP was not very low but acceptable considering that NIRS is commonly used in macro amount analysis and it is quite difficult for NIRS to determine micro amount analytes, especially, less than 1 μg mL^-1.展开更多
Precast segmental column bridges exhibit various construction advantages in comparison to traditional monolithic column bridges.However,the lack of cognitions on seismic behaviors has seriously restricted their applic...Precast segmental column bridges exhibit various construction advantages in comparison to traditional monolithic column bridges.However,the lack of cognitions on seismic behaviors has seriously restricted their applications and developments.In this paper,comprehensive investigations are conducted to analyze the dynamic characteristics of precast segmental column bridges under near-fault,forward-directivity ground motions.First,the finite-element models of two comparable bridges with precast segmental columns and monolithic columns are constructed by using OpenSees software,and the nonlinearities of the bridges are considered.Next,three different earthquake loadings are meticulously set up to handle engineering problems,namely recorded near-and far-field ground motions,parameterized pulses,and pulse and residual components extracted from real records.Finally,based on the models and earthquake sets,extensive explorations are carried out.The results show that near-fault forward-directivity ground motions are more threatening than far-field ones;precast segmental column bridges may suffer more pounding impacts than monolithic bridges;the“narrow band”effect caused by near-fault,forward-directivity ground motions may occur in bridges with shorter periods than pulse periods;and pulse and residual components play different roles in seismic responses.展开更多
基金the National Natural Science Foundation of China(Grant Nos.:82273885,82073808 and 81872828).
文摘Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary electrochromatography by the in situ polymerization of sodium p-styrene sulfonate(VBS)with cross-linkers 3-(acryloyloxy)-2-hydroxypropyl methacrylate(AHM)and 1,3,5-triacryloylhexahydro-1,3,5-triazine(TAT).The preparation conditions of the monolith were optimized.The morphology and formation of the poly(VBS-co-TAT-co-AHM)monolith were confirmed by scanning electron microscopy(SEM)and Fourier transform infrared spectroscopy(FT-IR).The separation perfor-mances of the monolith were evaluated systematically.It should be noted that the incorporation of VBS functional monomer can provideπ-πinteractions,hydrophilic interactions,and ion-exchange in-teractions.Hence,the prepared poly(VBS-co-TAT-co-AHM)monolith can achieve efficient separation of thiourea compounds,benzene series,phenol compounds,aniline compounds and sulfonamides in RPLC or HILIC separation mode.The largest theoretical plate number for N,N0-dimethylthiourea reached 1.7×10^(5)plates/m.In addition,the poly(VBS-co-TAT-co-AHM)monolithic column showed excellent reproducibility and stability.This novel monolithic column has great application value and potential in capillary electrochromatography(CEC).
基金This work was supported by the National Natural Science Foundation of China(20575045)outstanding scholar programs of Tianjin Medical University(to Z.S.Liu).
文摘Molecularly imprinted polymers (MIPs), using (S)-naproxen as template and the combination of butyl methacrylate (BMA) and MAA (1:1 molar ratio) as functional monomers were synthesized by an in situ polymerization reaction. The rendered monolithic column was evaluated in HPLC mode. The result showed that the monolithic MIPs with the combination of two monomers produced better chiral resolution of rac-naproxen (Rs = 1.55) and column efficiencies of imprinted molecules (N = 2860 plates/m) than that with pure MAA.
文摘Fritless packed silica gel columns were prepared using sol-gel technology, The part of a 75 μm i.d. capillary was filled with a mixture of methacryloxypropyltrimethoxysilane, toluene and hydrochloric acid. Four different photoinitiators such as benzoin methyl ether, Irgacure 819, Irgacure 1700 and Irgacure 1800 were added in the presence or absence of sodium dodecyl sulfate during the polymerization process. The above eight solutions were irradiated at 365 nm about 5-10 min to prepare the porous monolithic sol-gel columns by a one-step process.
基金supported by the National Natural Science Foundation of China(No.20575030)
文摘To make more homogenous organic monolithic structure, reversible addition-fragmentation chain transfer (RAFT) process was employed in the synthesis of the clenbuterol imprinted polymer. In the synthesis, the influence of synthetic conditions on the polymer structure and separation efficiency was studied. The result demonstrated that the imprinted columns prepared with RAFT process have higher column efficiency and selectivity than the columns prepared with conventional polymerization in the present study, which may result from the higher surface area, smaller pore size and the narrower globule size distribution in their structures. The result indicated that RAFT polymerization provided better conditions for the clenbuterol imprinted monolithic polymer preparation. 2009 Xiang Chao Dong. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
基金supported by the National Natural Science Foundation of China(Nos.90813015,20935002)
文摘Monolithic silica spin column extraction (MonoSpin-SPE) was developed as a simple, sensitive, and eco-friendly pretreatment method which combined with ultra-fast liquid chromatography-mass spectrometry (UFLC-MS) to determine the levels of six phthalate esters, dimethyl- (DMP), diethyl- (DEP), dipropyl- [ DPrP], butyl-benzyl- (BBP), dicyclohexyl- (DcHP), and di-n-octyl-(DOP) phthalate in physiological saline samples. Under optimized experimental conditions, the method was linear in the following ranges: 0.2- 50 μg/L for DMP, DEP, DPrP, DcHP and DOP; 5- 100 μg/L for BBP. The correlation coefficients (R2 ) were in the range of 0. 9951 - 0. 9995 for all the analytes and the limits of detection (LODs) and limits of quantification (LOQs) were in the ranges of 0.02 - 0.9 μg/L and 0.08 - 2.7μg/L, respectively. The pretreatment process showed good reproducibility with inter-day and intra-day relative standard deviations (RSDs) below 8.5% and 11.2%, respectively. This method was used to determine the levels of six phthalate esters in physiological saline samples and the recoveries ranged from 71.2% to 107.3%. DMP and DEP were found in actual physical saline samples (brand A and brand B).
文摘Microwave irradiation was firstly attempted for the preparation of organic-based monoliths of poly(styrene-divinylbenzene- methacrylic acid), which single step in situ polymerization was carried out during 15 min. The colunm permeability, electrophoretic and chromatographac behaviors were comparatively evaluated using pressure-assisted CEC, GEC and low pressure-driven separation modes. The largest theoretical plates for the preparing column could be close to 18,0000 plates/m for thiourea in the mode of p-CEC. It provided a viable alternative to traditional initiation means for the perparation of monolithic capillary columns.
文摘A monolithic molecularly imprinted polymer with specific recognition ability for 4-hydroxybenzoic acid (4-HBA) was prepared by in situ photopolymerization, using methacrylic acid (MAA) as a functional monomer, ethylene glycol dimethacrylate (EDMA) as a cross-linking agent, toluene and isooctane as porogenic solvents and Irgacure 1800 as an initiator. Baseline separation of isomers of hydroxybenzoic acid was achieved in less than 8 min on this monolithic column using 4-HBA as template, but not on the blank polymer. Furthermore, some neutral compounds could also be baseline-separated on the imprinted polymer column in the mode of pressure-driven capillary electrochromatography.
文摘An analytical methodology based on an O-[2-(methacryloyloxy)-ethylcarbamoyl]-10,11-dihydroquinidine(MQD)-silica hybrid monolithic column was developed for the enantioseparation of 9-fluorenylmethoxycarbonyl(FMOC)derivatized amino acids by nano-liquid chromatography.The mobile phase was optimized including the apparent pH,content of ACN,and concentration of the buffer to obtain a satisfactory enantioresolution performance.27 FMOC derivatized amino acids including 19 protein and 8 non-protein amino acids were tested,and 19 out of them were enantiomerically discriminated obtaining baseline separation for 11 of them.Analytical characteristics of the method were evaluated for norvaline and tryptophan in terms of linearity,precision,accuracy,limits of detection(LOD)and quantitation(LOQ)showing good performance to be applied to the enantiomeric determination of these amino acids in dietary supplements.LOD and LOQ values were 9.3 and 31 mM for norvaline enantiomers and 7.5 and 25 mM for tryptophan enantiomers,respectively.The contents of D-norvaline and D-tryptophan were below their respective LODs in all the analyzed samples.Quantitation of L-tryptophan and L-norvaline showed good agreement with the labeled contents except for one sample which did not show presence of L-norvaline,contrary to the label indication.
文摘Methacrylate-based monolithic column was prepared in fused-silica capillary (80 ′ 0.32 mm i.d.) by in situ polymerizetion reaction using glycidyl methacrylate as monomer;ethylene dimethacrylate as crosslinker;1-propanol, 1,4-butanediol, and water as porogenic solvents. The monolith matrix was modified with trimethylamine to create strong anion exchanger via ring opening reaction of epoxy groups. The morphology of the monolithic column was studied by using Scanning Electron Microscope (SEM). This column had good mechanical stability and permeability. The effects of various mobile phases for separation of inorganic anions were investigated. Iodate, bromate, nitrite, bromide, and nitrate were separated within 11 min using100 mMpotassium chloride as mobile phase and detected at 210 nm. This method showed good precision of retention time, acceptable linearity and good sensitivity. Under the optimum condition, the RSD of the retention time was in the range of 1.09%-1.75% (n = 6). The calibration curve showed linear relationships between the peak area and the concentration. The limits of detection (LOD) and the limits of quantitation (LOQ) were between 0.08-0.18 mM and 0.26-0.61 mM, respectively. This method was applied to the determination of inorganic anions in tap water and ground water samples.
文摘A porous monolithic sol-gel column with the solution of methacryloxypropyltrimethoxysilane in toluene with an acid catalyst was prepared in the presence and absence of sodium dodecyl sulfate. In situ polymerization was carded out by γ-ray irradiation within the capillary. The γ-radiation-initiated synthesis could generate radicals directly on the monomer avoiding use of any initiator. The chromatographic behavior of the capillary monolithic columns were studied in the modes of CEC, p-CEC and low pressure-driven separation, all the tests exhibited reversed-phase character. It provided a viable alternative to either thermally initiated or photo polymerization method for the preparation of monolithic columns.
文摘A novel monolithic stationary phase having long alkyl chain ligands was introduced and evaluated in pressurized-capillary electrochromatography of small neutral and charged compounds. The monolithic column was prepared by the in situ copolymerization of ethylene dimethacrylate, 1-hexadecene, allyl alcohol and 2-acrylamido-2-methyl-1-propanesulfonic acid in a quaternary porogenic solvent mixture consisting of 1, 4-butanediol, cyclohexanol, dodecanol and water.
基金Project(20611140646) supported by the NSFC-KOSEF Scientific Cooperation Program project(2006HANCET-01) supported by Program for New Century Talents of University of Henan Provinceproject(2005-461-140) supported by Program for Backbone Teacher in Henan Province
文摘Photopolymerized sol-gel(PSG) columns were prepared using methacryloxypropyltrimethoxysilane as the monomer,toluene as the porogen and hydrochloric acid as the catalyst.Four different photoinitiators such as benzoin methyl ether,Irgacure 819,Irgacure 1700 and Irgacure 1800 were comparatively used in the reaction solution in the presence and absence of sodium dodecyl sulfate.The above eight solutions were respectively irradiated at 365 nm for 5?10 min in each capillary(75 μm inside diameter) to prepare the porous monolithic sol-gel column by a one-step,in situ,process.The chromatographic behavior of the eight PSG columns were comparatively studied,all of which exhibit reversed-phase character.Using these columns,several neutral compounds,namely thiourea,benzene,toluene,ethyl benzene,biphenyl and naphthalene can be separated from mixtures with a largest column efficiency of 74 470 plate/column for thiourea.Addition of sodium dodecyl sulfate in the polymerization process has a significant influence on the morphology and migration time.
基金sponsored by Shanghai Pujiang Program(2006)supported by Science and Technology Commission of Shanghai Municipality(No.0652nm020).
文摘Silica-based monolithic column material was synthesized and an enrichment device was fabricated with the material by assembling the material inside a glass column. The enrichment device was applied for the determination of micro-carbaryl with near-infrared spectroscopy (NIRS). The aqueous solutions of carbaryl passed through the device and the carbaryl was enriched on the surface of the material where diffuse reflection NIR spectra were measured. These procedures of enrichment and measurement ensured to concentrate analytes for the measurement, so that the sensitivity of determination of MRS could be improved. NIR spectra of carbaryl solutions (0.01-1.00μg mL^-1), measured after the application of the enrichment device, were pretreated with multiplicative scatter correction (MSC) and regressed against the concentrations of the carbaryl solutions with partial least squares (PLS) method. The results showed that the minimum value of root-mean-square error of prediction (RMSEP) was 0.1771 μg mL^-1 when the number of latent variables was 3 of PLS regression. Therefore, the number of latent variables 3 was selected as the optimum value. RMSEP was not very low but acceptable considering that NIRS is commonly used in macro amount analysis and it is quite difficult for NIRS to determine micro amount analytes, especially, less than 1 μg mL^-1.
基金National Natural Science Foundation of China under Grant Nos.U1434205 and 51678490the Major Research Plan of China National Railway Ministry of China under Grant Nos.2015G002-B and P2018G007the National Key R&D Program of China under Grant No.2017YFC1500803。
文摘Precast segmental column bridges exhibit various construction advantages in comparison to traditional monolithic column bridges.However,the lack of cognitions on seismic behaviors has seriously restricted their applications and developments.In this paper,comprehensive investigations are conducted to analyze the dynamic characteristics of precast segmental column bridges under near-fault,forward-directivity ground motions.First,the finite-element models of two comparable bridges with precast segmental columns and monolithic columns are constructed by using OpenSees software,and the nonlinearities of the bridges are considered.Next,three different earthquake loadings are meticulously set up to handle engineering problems,namely recorded near-and far-field ground motions,parameterized pulses,and pulse and residual components extracted from real records.Finally,based on the models and earthquake sets,extensive explorations are carried out.The results show that near-fault forward-directivity ground motions are more threatening than far-field ones;precast segmental column bridges may suffer more pounding impacts than monolithic bridges;the“narrow band”effect caused by near-fault,forward-directivity ground motions may occur in bridges with shorter periods than pulse periods;and pulse and residual components play different roles in seismic responses.