期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Establishment of a new method of digital orthopedic surgery and its widespread clinical application
1
作者 丁焕文 《外科研究与新技术》 2011年第2期126-127,共2页
Objective To create an unique new method of digital orthopedic surgery and widely apply to spinal surgery,treatment of bone and joint injuries,ligament reconstruction and repair,bone minor resection and reconstruction... Objective To create an unique new method of digital orthopedic surgery and widely apply to spinal surgery,treatment of bone and joint injuries,ligament reconstruction and repair,bone minor resection and reconstruction,serious bone and 展开更多
关键词 Establishment of a new method of digital orthopedic surgery and its widespread clinical application
下载PDF
Recent Progress in Cartilage Tissue Engineering--Our Experience and Future Directions 被引量:10
2
作者 Yu Liu Guangdong Zhou Yilin Cao 《Engineering》 SCIE EI 2017年第1期28-35,共8页
Given the limited spontaneous repair that follows cartilage injury, demand is growing for tissue engi- neering approaches for cartilage regeneration. There are two major applications for tissue-engineered cartilage. O... Given the limited spontaneous repair that follows cartilage injury, demand is growing for tissue engi- neering approaches for cartilage regeneration. There are two major applications for tissue-engineered cartilage. One is in orthopedic surgery, in which the engineered cartilage is usually used to repair cartilage defects or loss in an articular joint or meniscus in order to restore the joint function. The other is for head and neck reconstruction, in which the engineered cartilage is usually applied to repair cartilage defects or loss in an auricle, trachea, nose, larynx, or eyelid. The challenges faced by the engineered car- tilage for one application are quite different from those faced by the engineered cartilage for the other application. As a result, the emphases of the engineering strategies to generate cartilage are usually quite different for each application. The statuses of preclinical animal investigations and of the clinical translation of engineered cartilage are also at different levels for each application. The aim of this review is to provide an opinion piece on the challenges, current developments, and future directions for cartilage engineering for both applications. 展开更多
关键词 Cartilage tissue engineering Preclinical immunocompetent animal investigation clinical translation Orthopedic surgery Head and neck reconstruction
下载PDF
Radiation Protection of a Patient Undergoing an Orthopedic Procedure by Using a Mobile C-Arm X-Ray System 被引量:1
3
作者 Natasha Ivanova 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2020年第3期141-156,共16页
Modern medicine is unthinkable without X-rays. Accurate diagnosis, leading to effective treatment, is largely based on precise X-ray examinations. The creation of new, modern equipment and various medical procedures t... Modern medicine is unthinkable without X-rays. Accurate diagnosis, leading to effective treatment, is largely based on precise X-ray examinations. The creation of new, modern equipment and various medical procedures that meet the increased requirements are a priority in our time. X-ray examinations are of particular importance for the orthopedic and traumatological clinics, where they provide information about presence of a fracture in the patient’s body, about the concrete operation performed or about the effect of a suitable treatment. Along with their benefits X-rays have also a harmful effect. This requires special care to protect from this radiation. In this direction, research is constantly being done to improve the quality of radiation protection. Park MR, Lee KM and co-authors, compare the dose load obtained using C-arm and O-arm X-ray systems (which have the capability of combined 2D fluoroscopy and 3D computed tomography imaging). In their study, an orthopedic surgical procedure using C-arm and O-arm systems in 2D fluoroscopy modes was simulated. The radiation doses to susceptible organs of the operators were investigated. He results obtained show that the O-arm system delivered higher doses to the sensitive organs of the operator in all configurations [1]. The article of Stephen Balte briefly reviews the available technologies for measuring or estimation of patient skin dose in the interventional fluoroscopic environment, created by various X-ray equipment including C-arm systems. Given that many patients require multiple procedures, this documentation also aids in the planning of follow up visits [2]. Chong Hing Wong, Yoshihisa Kotani and co-authors evaluate the radiation exposures (RE) to the patient and surgeon during minimally invasive lumbar spine surgery with instrumentation using C-arm image intensifier or O-arm intraoperative CT. The results they get are in favor of the O-arm system [3]. The article “Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction” discusses positioning of an intraoperative C-arm system to achieve clear visualization of a particular anatomical feature by a system for virtual fluoroscopy (called FluoroSim) that could dramatically reduce time and received dose during the procedures. FluoroSim was found to reduce the radiation exposure required for C-arm positioning without reducing positioning time or accuracy, providing a potentially valuable tool to assist surgeons [4]. In our study, we performed practical measurements to show how the patient can be treated by applying most effective radiation protection when using a mobile C-arm X-ray system. For the study, we used exposure upon a phantom placed on the patient’s table. For an X-ray shielding, we used a protective apron with a lead equivalent of 1 mm, placed in two layers on the phantom. In each subsequent series of exposures, the protective apron was placed on the phantom, in a different position relative to the X-ray beam. The general conclusion of our study is that in order to obtain maximum protection from scattered radiation when using C-arm X-ray systems, the patient must be protected by a shielding with a suitable lead equivalent for the procedure performed which must be placed between patient’s body and X-ray tube, perpendicular to the X-ray beam pointed toward the region of interest. 展开更多
关键词 C-Arm X-Ray Equipment Radiation Protection PATIENT orthopedics and Traumatology Clinic
下载PDF
Implementation of evidence-based practice by standardized care plans: A study protocol
4
作者 Inger Jansson Eva Tornvall 《Open Journal of Nursing》 2013年第8期51-57,共7页
Background: Patient records should both transfer and create knowledge about patients and their health care. A standardized care plan could be a way to implement evidence-based care directly in practice and improve the... Background: Patient records should both transfer and create knowledge about patients and their health care. A standardized care plan could be a way to implement evidence-based care directly in practice and improve the documentation in patient records. The aim of this study is to investigate and compare the development and implementation process of a standardized care plan in hospital and primary health care. A further aim is to evaluate the effects on the quality of documentation and the care given in two contexts. Methods and Analysis: Realistic evaluation will be used as a framework to investigate the implementation process. According to this framework, possible contexts, mechanisms, and outcomes in the study will be considered. The study will be performed in two contexts: an orthopedic clinic and primary health care centers. In both contexts, the two key mechanisms will be the same: the implementation process will be driven by internal facilitators (practitioners at the units) and the process will be guided by the Rules and Regulations for interoperability in the Health and Social Care specification, “National information structure for standardized care plans”. Two outcomes of the study will be studied: to investigate the development and implementation process by an evaluation of fidelity and to evaluate how a standardized care plan affects the quality of documentation and the use of evidence-based care. Discussion: Implementation of the SCP will probably meet the same resistance as implementation of guidelines. Documentation of care is an important but resource-consuming requirement in health care, a more standardized method of documenting is requested by health professionals. This project can provide insight into the complex process of developing and implement an SCP in different contexts, which will be useful in further implementation processes. 展开更多
关键词 Standardized Care Plan Orthopedic Clinic Primary Health Care Realistic Evaluation
下载PDF
The relationship between orthopedic clinical imaging and bone strength prediction 被引量:1
5
作者 He Gong Meng Zhang +1 位作者 Shaowei Jia Linwei Lv 《Medicine in Novel Technology and Devices》 2021年第1期9-17,共9页
Pathologic fracture is caused by bone diseases,which is common in middle-aged and elderly adults.Compromised bone strength is the leading contributor to this type of fracture.Therefore,accurately quantifying bone stre... Pathologic fracture is caused by bone diseases,which is common in middle-aged and elderly adults.Compromised bone strength is the leading contributor to this type of fracture.Therefore,accurately quantifying bone strength could help clinicians assess individualized fracture risk and develop therapeutic interventions.Orthopedic clinical imaging including dual X-ray absorptiometry(DXA),computed tomography(CT),and magnetic resonance imaging(MRI)has been an important tool to obtain radiology images of bone,which could be further used for noninvasive assessment of bone strength and related fracture risk.With the development of biomechanics and computer technology,the combination of finite element analysis with orthopedic imaging is the most advanced method for noninvasive prediction of bone strength in clinics.In this review,an overview is provided for the commonly noninvasive methods based on the radiology images(i.e.,DXA,CT,and MRI)to predict bone strength,which may improve the understanding of the relationship between orthopedic clinical imaging and biomechanics. 展开更多
关键词 Orthopedic clinical imaging BIOMECHANICS Bone strength Finite element analysis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部