BACKGROUND Recently,medical three-dimensional printing technology(3DPT)has demonstrated potential benefits for the treatment of cubitus varus deformity(CVD)by improving accuracy of the osteotomy through the use of an ...BACKGROUND Recently,medical three-dimensional printing technology(3DPT)has demonstrated potential benefits for the treatment of cubitus varus deformity(CVD)by improving accuracy of the osteotomy through the use of an osteotomy guide,with or without a patient-mated plate.Here,we present an interesting CVD case,involving a patient who was treated with corrective biplanar chevron osteotomy using an innovative customized osteotomy guide and a newly designed patient-matched monoblock crosslink plate created with 3DPT.CASE SUMMARY A 32-year-old female presented with a significant CVD from childhood injury.A computer simulation was processed using images from computerized tomography scans of both upper extremities.The biplanar chevron osteotomy was designed to create identical anatomy between the mirror image of the contralateral distal humerus and the osteotomized distal humerus.Next,the customized osteotomy guide and patient-matched monoblock crosslink plate were designed and printed.A simulation osteotomy was created for the real-sized bone model,and the operation was performed using the posterior paratricipital approach with k-wire positioning from the customized osteotomy guide as a predrilled hole for screw fixation to achieve immediate control of the reduction after osteotomy.Our method allowed for successful treatment of the CVD case,significantly improving the patient’s radiographic and clinical outcomes,with satisfactory result.CONCLUSION 3DPT-created patient-matched osteotomy guide and instrumentation provides accurate control during CVD correction.展开更多
Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA).This study investigated a customized guide ...Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA).This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee.Methods: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method.In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation.TSG cases were treated with the conventional method.Outcomes were obtained from the postoperative image examination and short-term follow-up.Results: Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG.The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively.The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG.Statistically significant differences were found between GPG and TSG in all measurements.Conclusions: A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images.This allows for shorter operative times and better postoperative alignment than the traditional surgery.Application of the digital guide plate may also result in better short-term outcomes.展开更多
Aim:To present a simple technical modification of a medial osteotomy cut which prevents its misdirection and overcomes various anatomical variations as well as technical problems.Methods:The medial osteotomy cut is mo...Aim:To present a simple technical modification of a medial osteotomy cut which prevents its misdirection and overcomes various anatomical variations as well as technical problems.Methods:The medial osteotomy cut is modified in the posterior half at an angle of 15°-20°following novel landmarks.Results:The proposed cut exclusively directs the splitting forces downwards to create a favorable lingual fracture,preventing the possibility of an upwards split which would cause a coronoid or condylar fracture.Conclusion:This modification has proven to be successful to date without encountering the complications of a bad split or nerve damage.展开更多
文摘BACKGROUND Recently,medical three-dimensional printing technology(3DPT)has demonstrated potential benefits for the treatment of cubitus varus deformity(CVD)by improving accuracy of the osteotomy through the use of an osteotomy guide,with or without a patient-mated plate.Here,we present an interesting CVD case,involving a patient who was treated with corrective biplanar chevron osteotomy using an innovative customized osteotomy guide and a newly designed patient-matched monoblock crosslink plate created with 3DPT.CASE SUMMARY A 32-year-old female presented with a significant CVD from childhood injury.A computer simulation was processed using images from computerized tomography scans of both upper extremities.The biplanar chevron osteotomy was designed to create identical anatomy between the mirror image of the contralateral distal humerus and the osteotomized distal humerus.Next,the customized osteotomy guide and patient-matched monoblock crosslink plate were designed and printed.A simulation osteotomy was created for the real-sized bone model,and the operation was performed using the posterior paratricipital approach with k-wire positioning from the customized osteotomy guide as a predrilled hole for screw fixation to achieve immediate control of the reduction after osteotomy.Our method allowed for successful treatment of the CVD case,significantly improving the patient’s radiographic and clinical outcomes,with satisfactory result.CONCLUSION 3DPT-created patient-matched osteotomy guide and instrumentation provides accurate control during CVD correction.
文摘Background: The conventional method cannot guarantee the precise osteotomies required for a perfect realignment and a better prognosis after total knee arthroplasty (TKA).This study investigated a customized guide plate for osteotomy placement in TKAs with the aid of the statistical shape model technique using weight-bearing lower-extremity X-rays and computed tomography (CT) images of the knee.Methods: From October 2014 to June 2015, 42 patients who underwent a TKA in Guizhou Provincial People's Hospital were divided into a guide plate group (GPG, 21 cases) and a traditional surgery group (TSG, 21 cases) using a random number table method.In the GPG group, a guide plate was designed and printed using preoperative three-dimensional measurements to plan and digitally simulate the operation.TSG cases were treated with the conventional method.Outcomes were obtained from the postoperative image examination and short-term follow-up.Results: Operative time was 49.0 ± 10.5 min for GPG, and 62.0 ± 9.7 min in TSG.The coronal femoral angle, coronal tibial angle, posterior tibial slope, and the angle between the posterior condylar osteotomy surface and the surgical transepicondylar axis were 89.2 ± 1.7°, 89.0 ± 1.1°, 6.6 ± 1.4°, and 0.9 ± 0.3° in GPG, and 86.7 ± 2.9°, 87.6 ± 2.1°, 8.9 ± 2.8°, and 1.7 ± 0.8° in TSG, respectively.The Hospital for Special Surgery scores 3 months after surgery were 83.7 ± 18.4 in GPG and 71.5 ± 15.2 in TSG.Statistically significant differences were found between GPG and TSG in all measurements.Conclusions: A customized guide plate to create an accurate osteotomy in TKAs may be created using lower-extremity X-ray and knee CT images.This allows for shorter operative times and better postoperative alignment than the traditional surgery.Application of the digital guide plate may also result in better short-term outcomes.
文摘Aim:To present a simple technical modification of a medial osteotomy cut which prevents its misdirection and overcomes various anatomical variations as well as technical problems.Methods:The medial osteotomy cut is modified in the posterior half at an angle of 15°-20°following novel landmarks.Results:The proposed cut exclusively directs the splitting forces downwards to create a favorable lingual fracture,preventing the possibility of an upwards split which would cause a coronoid or condylar fracture.Conclusion:This modification has proven to be successful to date without encountering the complications of a bad split or nerve damage.