An on-chip power-on reset circuit with a brown-out detection capability is implemented in a 0. 18 μm CMOS. A pF-order capacitor is charged with a proportional-to-absolute-temperature (PTAT) current from a bandgap r...An on-chip power-on reset circuit with a brown-out detection capability is implemented in a 0. 18 μm CMOS. A pF-order capacitor is charged with a proportional-to-absolute-temperature (PTAT) current from a bandgap reference with limited loop bandwidth and slow start-up feature, to generate a reset signal with high robustness and wide-range supply rise time. An embedded brown- out detector based on complementary voltage-to-current (V-to-I) conversion and current comparison can accurately respond to the brown-out event with high robustness over process and temperature when the supply is lower than 1.5 V and the brown-out duration is longer than 0. 1 ms. The presented design with embedded offset voltage cancellation consumes a quiescent current of 8. 5 μA from a 1. 8 V supply and works over ambient temperature of -40° to 120°.展开更多
Power swing evoked by sudden changes like faults or switching operations will become more and more important for protective relaying, due to the growing load flow in electrical power networks. Unwanted trips of the di...Power swing evoked by sudden changes like faults or switching operations will become more and more important for protective relaying, due to the growing load flow in electrical power networks. Unwanted trips of the distance protection function must be avoided to prevent cascading effects and blackouts in the network. Selective out-of-step-tripping is required to stop unstable power swing and to prevent damage to affected generators. Therefore a reliable method for detection of power swing is presented, which requires no settings for operation. Power swing can be detected from 0.1 Hz up to 10 Hz swing frequency, also during open pole condition and during asymmetrical operation. A blocking logic prevents unselective trips by the distance protection. However, faults that occur during a power swing must be detected and cleared with a high degree of selectivity and dependability. For unstable power swing a flexible out of step tripping function will be proposed. The coordination of power swing detection, distance protection and out of step protection provides a reliable system protection.展开更多
Based on the idea of risk evaluation, the existing lightning damage risk assessment methods are reviewed and summarized in this paper. And the power grid lightning damage risk assessment system is established on the b...Based on the idea of risk evaluation, the existing lightning damage risk assessment methods are reviewed and summarized in this paper. And the power grid lightning damage risk assessment system is established on the basis of lightning flashover risk evaluation methodology for transmission lines, and adopts the improved Analytic Hierarchy Process as the core algorithm. It can comprehensively evaluate the risk for transmission lines of regional grid, various sections of a line and each tower of the section, considering much more impact factors, including the running time of line, importance of grades, equipment damage, and the success rate of lightning stroke reclosing and so on. According to the calculation results of the risk assessment of the analytic hierarchy process and lightning flashover risk evaluation, the principles and methods of grade classification for power grid lightning damage risk map are studied, and give typical examples in the paper. It can describe the lightning withstanding ability much more scientifically and provide important references for the manage department of power system.展开更多
This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil c...This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission.展开更多
The subsea anchor piles of offshore wind power floating platform structures are mainly subjected to uplift and horizontal loads, and this paper focuses on the case of horizontal loads. A three-dimensional numerical si...The subsea anchor piles of offshore wind power floating platform structures are mainly subjected to uplift and horizontal loads, and this paper focuses on the case of horizontal loads. A three-dimensional numerical simulation study of the horizontal pullout characteristics of wind power suction anchor piles in clay layers was carried out to reveal the horizontal movement state of the anchor piles during horizontal pile pullout, the range of pile depth at the pullout point where the horizontal movement is achieved (referred to as the horizontal movement range), the relationship between the pullout load and the ultimate load during the horizontal movement, and the optimal location of the pullout point for the horizontal movement. The results show that at certain pull-out points, the anchor pile produces an overall horizontal movement state under suitable horizontal pull-out loads. The depth of the pile pull-out point for horizontal movement is in the middle and lower part of the pile, i.e. 14.2 m to 14.5 m. The horizontal pull-out load of 24,000 kN at a depth of 14.5 m within the pile horizontal movement range of 14.2m to 14.5 m is the maximum ultimate horizontal pull-out load;the optimum pull-out point depth is 14.5 m at 0.275 L (L is the pile length). For each pull-out point of the anchor pile in horizontal movement, the horizontal pull-out load in horizontal movement and the horizontal ultimate pull-out load existed and it was found that the two values were not exactly the same, the values were compared and it was found that at the optimum pull-out point the value of the ultimate horizontal pull-out load/horizontal pull-out load in horizontal movement tended to 1.展开更多
In recent 20 years, energy saving has been done in many projects. However, in pneumatic system, it is not easy to determine or measure the air power flow because of the compressibility of pneumatic system. In this pap...In recent 20 years, energy saving has been done in many projects. However, in pneumatic system, it is not easy to determine or measure the air power flow because of the compressibility of pneumatic system. In this paper, we used air power meter (APM) to measure the energy consumption of flow in pneumatic cylinder actuator system. Meter-in circuit and meter-out circuit of speed control system are used in this research. The model of cylinder system is based on four equations: state equation of air, energy equation, motion equation and flow equation. The model estimates the pressure change in charge and discharge side of cylinder, and also the displacement and velocity of the piston. Furthermore, energy consumption could theoretically be calculated when the change of air state is regarded as isothermal change. Lastly, some data of these two circuits are shown, and the consumption of energy is discussed.展开更多
基金Supported by the National Natural Science Foundation of China(6130603761201182)
文摘An on-chip power-on reset circuit with a brown-out detection capability is implemented in a 0. 18 μm CMOS. A pF-order capacitor is charged with a proportional-to-absolute-temperature (PTAT) current from a bandgap reference with limited loop bandwidth and slow start-up feature, to generate a reset signal with high robustness and wide-range supply rise time. An embedded brown- out detector based on complementary voltage-to-current (V-to-I) conversion and current comparison can accurately respond to the brown-out event with high robustness over process and temperature when the supply is lower than 1.5 V and the brown-out duration is longer than 0. 1 ms. The presented design with embedded offset voltage cancellation consumes a quiescent current of 8. 5 μA from a 1. 8 V supply and works over ambient temperature of -40° to 120°.
文摘Power swing evoked by sudden changes like faults or switching operations will become more and more important for protective relaying, due to the growing load flow in electrical power networks. Unwanted trips of the distance protection function must be avoided to prevent cascading effects and blackouts in the network. Selective out-of-step-tripping is required to stop unstable power swing and to prevent damage to affected generators. Therefore a reliable method for detection of power swing is presented, which requires no settings for operation. Power swing can be detected from 0.1 Hz up to 10 Hz swing frequency, also during open pole condition and during asymmetrical operation. A blocking logic prevents unselective trips by the distance protection. However, faults that occur during a power swing must be detected and cleared with a high degree of selectivity and dependability. For unstable power swing a flexible out of step tripping function will be proposed. The coordination of power swing detection, distance protection and out of step protection provides a reliable system protection.
文摘Based on the idea of risk evaluation, the existing lightning damage risk assessment methods are reviewed and summarized in this paper. And the power grid lightning damage risk assessment system is established on the basis of lightning flashover risk evaluation methodology for transmission lines, and adopts the improved Analytic Hierarchy Process as the core algorithm. It can comprehensively evaluate the risk for transmission lines of regional grid, various sections of a line and each tower of the section, considering much more impact factors, including the running time of line, importance of grades, equipment damage, and the success rate of lightning stroke reclosing and so on. According to the calculation results of the risk assessment of the analytic hierarchy process and lightning flashover risk evaluation, the principles and methods of grade classification for power grid lightning damage risk map are studied, and give typical examples in the paper. It can describe the lightning withstanding ability much more scientifically and provide important references for the manage department of power system.
文摘This paper uses CT to gain the energy directly from the high-voltage transmission line, to address the problem of power supply for monitoring system in high voltage side of transmission line. The draw-out power coil can induce voltage from the transmission line, using single-chip microcomputer to analog and output PMW wave to control the charging module, provides a stable 3.4 V DC voltage to the load, and solve the problem of easy saturating of core. The power supply based on this kind of draw-out power coil has undergone the overall testing, and it is verified-showing that it can properly work in a non-saturated status within the current range of 50 - 1000 A, and provide a stable output. The equipment also design protection circuit to improve the reliability to avid the impacts of the impulse current or short-circuit current. It effectively solves the problem of power supply for On-line Monitoring System of Transmission.
文摘The subsea anchor piles of offshore wind power floating platform structures are mainly subjected to uplift and horizontal loads, and this paper focuses on the case of horizontal loads. A three-dimensional numerical simulation study of the horizontal pullout characteristics of wind power suction anchor piles in clay layers was carried out to reveal the horizontal movement state of the anchor piles during horizontal pile pullout, the range of pile depth at the pullout point where the horizontal movement is achieved (referred to as the horizontal movement range), the relationship between the pullout load and the ultimate load during the horizontal movement, and the optimal location of the pullout point for the horizontal movement. The results show that at certain pull-out points, the anchor pile produces an overall horizontal movement state under suitable horizontal pull-out loads. The depth of the pile pull-out point for horizontal movement is in the middle and lower part of the pile, i.e. 14.2 m to 14.5 m. The horizontal pull-out load of 24,000 kN at a depth of 14.5 m within the pile horizontal movement range of 14.2m to 14.5 m is the maximum ultimate horizontal pull-out load;the optimum pull-out point depth is 14.5 m at 0.275 L (L is the pile length). For each pull-out point of the anchor pile in horizontal movement, the horizontal pull-out load in horizontal movement and the horizontal ultimate pull-out load existed and it was found that the two values were not exactly the same, the values were compared and it was found that at the optimum pull-out point the value of the ultimate horizontal pull-out load/horizontal pull-out load in horizontal movement tended to 1.
文摘In recent 20 years, energy saving has been done in many projects. However, in pneumatic system, it is not easy to determine or measure the air power flow because of the compressibility of pneumatic system. In this paper, we used air power meter (APM) to measure the energy consumption of flow in pneumatic cylinder actuator system. Meter-in circuit and meter-out circuit of speed control system are used in this research. The model of cylinder system is based on four equations: state equation of air, energy equation, motion equation and flow equation. The model estimates the pressure change in charge and discharge side of cylinder, and also the displacement and velocity of the piston. Furthermore, energy consumption could theoretically be calculated when the change of air state is regarded as isothermal change. Lastly, some data of these two circuits are shown, and the consumption of energy is discussed.