The purpose of this paper is to discuss the suitability of out-of-codes tall slab-column and shearwall structure and to popularize the structure in seismic region.In the research,flat-plate floor was used in slab-colu...The purpose of this paper is to discuss the suitability of out-of-codes tall slab-column and shearwall structure and to popularize the structure in seismic region.In the research,flat-plate floor was used in slab-column and shearwall structure in the practical engineering,the key parameters of slab-column and shearwall structure and frame-shearwall structure such as deflection,punching shear behavior,story drift and capability curve were worked out by static plastic analysis,elastic-plastic time history analysis and pushover analysis,then the suitability of out-of-codes tall slab-column and shearwall structure was evaluated.The results show that the out-of-codes tall slab-column and shearwall structure studies could satisfy the require of deflection and punching shear behavior,the story drift under 7 degree expected rare earthquake waves could satisfy the limit value in the codes and the seismic design spectrum was crossed by the capability curve of the structure and the structure could not collapse.The conclusion is that slab-column and shearwall structure with reasonable design built in Ⅱ soil site of intensity 7 seismic fortification zone can be designed higher than the limit height in the codes.展开更多
The Code for Seismic Design of Buildings(GB50011-2010)in 2016 and the method of seismic performance-based design for high-rise buildings in the Guide for Performance-based Design of High-Rise Buildings(TBI2017)are com...The Code for Seismic Design of Buildings(GB50011-2010)in 2016 and the method of seismic performance-based design for high-rise buildings in the Guide for Performance-based Design of High-Rise Buildings(TBI2017)are compared.In view of the characteristics and limitations of the seismic performance index set by the Sino-US seismic code,a“three-index”performance index system and evaluation process considering the displacement angle of the structural interlayer,the plastic damage degree of components and the plastic strain of material is put forward;combining the example of time-history analysis of a out-of-code high-rise building under the rare earthquakes is verified.The results show that the method of seismic performance evaluation by using deformation control index in Sino-US seismic code is relatively simple;however,both are lacking in the setting of specific components and the whole structure level respectively.The"three-index"system can comprehensively and quantitatively evaluate the seismic performance of out-of-code high-rise buildings.展开更多
文摘The purpose of this paper is to discuss the suitability of out-of-codes tall slab-column and shearwall structure and to popularize the structure in seismic region.In the research,flat-plate floor was used in slab-column and shearwall structure in the practical engineering,the key parameters of slab-column and shearwall structure and frame-shearwall structure such as deflection,punching shear behavior,story drift and capability curve were worked out by static plastic analysis,elastic-plastic time history analysis and pushover analysis,then the suitability of out-of-codes tall slab-column and shearwall structure was evaluated.The results show that the out-of-codes tall slab-column and shearwall structure studies could satisfy the require of deflection and punching shear behavior,the story drift under 7 degree expected rare earthquake waves could satisfy the limit value in the codes and the seismic design spectrum was crossed by the capability curve of the structure and the structure could not collapse.The conclusion is that slab-column and shearwall structure with reasonable design built in Ⅱ soil site of intensity 7 seismic fortification zone can be designed higher than the limit height in the codes.
文摘The Code for Seismic Design of Buildings(GB50011-2010)in 2016 and the method of seismic performance-based design for high-rise buildings in the Guide for Performance-based Design of High-Rise Buildings(TBI2017)are compared.In view of the characteristics and limitations of the seismic performance index set by the Sino-US seismic code,a“three-index”performance index system and evaluation process considering the displacement angle of the structural interlayer,the plastic damage degree of components and the plastic strain of material is put forward;combining the example of time-history analysis of a out-of-code high-rise building under the rare earthquakes is verified.The results show that the method of seismic performance evaluation by using deformation control index in Sino-US seismic code is relatively simple;however,both are lacking in the setting of specific components and the whole structure level respectively.The"three-index"system can comprehensively and quantitatively evaluate the seismic performance of out-of-code high-rise buildings.