Out-of-step oscillation is a very destructive physical phenomenon in power system, which could directly cause big blackout accompanied by serious sociology-economic impacts. Out-of-step splitting control is an indispe...Out-of-step oscillation is a very destructive physical phenomenon in power system, which could directly cause big blackout accompanied by serious sociology-economic impacts. Out-of-step splitting control is an indispensable means, which could protect the system from major shocks of out-of-step oscillation. After years of development, it has achieved certain amount of research results. Have the existing methods been able to meet the requirements of out-of-step splitting? What improvements are needed? Under this background, this review is written. It combs the development of out-of-step splitting control technologies and analyzes the technical routes and characteristics of different methods. It points out the contradiction between rapidity and optimality is the biggest technical problem, existing in both the traditional local measurement based out-of-step splitting protection and the wide-area information based out-of-step splitting protection. It further points out that the advantages of the two types of protections can be combined with the unique physical characteristics of the out-of-step center to form a more advantageous splitting strategy. Besides, facing the fact of large-scale renewable energy access to power grid in recent years, this review also analyzes the challenges brought by it and provides some corresponding suggestions. It is hoped to provide some guidance for the subsequent research work.展开更多
Under the background of complicated interconnected network,the splitting criterion for accurately capturing the electrical center in real time is the prerequisite of power grid splitting.This paper studies the feature...Under the background of complicated interconnected network,the splitting criterion for accurately capturing the electrical center in real time is the prerequisite of power grid splitting.This paper studies the features of electric quantity in the electrical center in aspect of the instantaneous frequency,and proposes the out-of-step splitting criterion for power systems based on bus voltage frequency.Firstly,through the establishment and solution to the out-of-step model of the power grid,the analytical expression of the voltage frequency at any position is obtained in the out-of-step oscillation,and the voltage frequency features of electrical center and non-electrical center are analyzed in details.Then,this paper constructs the typical scene of migration of electrical center to study the change rules of voltage frequency.Finally,the splitting criterion based on bus voltage frequency is proposed as well as the instruction for use.This criterion is easy to be realized and can adapt to the migration of electrical center.Also it is free from the limits of power network structure and operational mode.Simulation results of CEPRI-36 system and interconnected network example of one actual region verify the accuracy and the effectiveness of the proposed criterion.展开更多
基金supported by the National Natural Science Foundation of China(Grant No.62273207,61821004,62350083,62192755)the Future Young Scholars Program of Shandong University,China.
文摘Out-of-step oscillation is a very destructive physical phenomenon in power system, which could directly cause big blackout accompanied by serious sociology-economic impacts. Out-of-step splitting control is an indispensable means, which could protect the system from major shocks of out-of-step oscillation. After years of development, it has achieved certain amount of research results. Have the existing methods been able to meet the requirements of out-of-step splitting? What improvements are needed? Under this background, this review is written. It combs the development of out-of-step splitting control technologies and analyzes the technical routes and characteristics of different methods. It points out the contradiction between rapidity and optimality is the biggest technical problem, existing in both the traditional local measurement based out-of-step splitting protection and the wide-area information based out-of-step splitting protection. It further points out that the advantages of the two types of protections can be combined with the unique physical characteristics of the out-of-step center to form a more advantageous splitting strategy. Besides, facing the fact of large-scale renewable energy access to power grid in recent years, this review also analyzes the challenges brought by it and provides some corresponding suggestions. It is hoped to provide some guidance for the subsequent research work.
基金This work was supported by State Grid Corporation of China,Major Projects on Planning and Operation Control of Large Scale Grid(No.SGCC-MPLG029-2012)China Postdoctoral Science Foundation(No.2014M552080).
文摘Under the background of complicated interconnected network,the splitting criterion for accurately capturing the electrical center in real time is the prerequisite of power grid splitting.This paper studies the features of electric quantity in the electrical center in aspect of the instantaneous frequency,and proposes the out-of-step splitting criterion for power systems based on bus voltage frequency.Firstly,through the establishment and solution to the out-of-step model of the power grid,the analytical expression of the voltage frequency at any position is obtained in the out-of-step oscillation,and the voltage frequency features of electrical center and non-electrical center are analyzed in details.Then,this paper constructs the typical scene of migration of electrical center to study the change rules of voltage frequency.Finally,the splitting criterion based on bus voltage frequency is proposed as well as the instruction for use.This criterion is easy to be realized and can adapt to the migration of electrical center.Also it is free from the limits of power network structure and operational mode.Simulation results of CEPRI-36 system and interconnected network example of one actual region verify the accuracy and the effectiveness of the proposed criterion.