DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structu...DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.展开更多
Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increas...Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increasing in a data center. Thus, the heat density in a data center is much higher than that of usual offices. And typically, almost 40% of the total power consumption is used for cooling servers in a data center. Thus, cooling effectiveness is one of the most important factors in evaluating the value of the data center. The data center taken up in this paper is located in Ishikari, where is a cold district in Japan. Using the cool outdoor air for cooling servers helps us to cut the power consumption for cooling. This paper first assesses the efficiency of Ishikari data center measuring the temperature of seven parts in a building where the cooling air flowing. Second, this paper describes the most efficient method for the operation and estimates 1.11 of PUE (power usage effectiveness).展开更多
The paper presents a simple model for outdoor air contaminant transmission into occupied rooms. In the model, several factors such as filtration, ventilation, deposition, re-emission, outdoor concentration and indoor ...The paper presents a simple model for outdoor air contaminant transmission into occupied rooms. In the model, several factors such as filtration, ventilation, deposition, re-emission, outdoor concentration and indoor sources are included. The model results show that the air exchange rate plays an important role in the transmission of outdoor contaminants into the indoor environment. The model shows that increasing the value of the filtration efficiency decreases the mass concentration of indoor particles. In addition, if outdoor aerosol particles have a periodic behaviour, indoor aerosol particles also behave periodically but smoother. Indoor sources are found to be able to increase indoor concentrations greatly and continuously.展开更多
Mitigation of urban air pollution has been constrained by the availability of urban spaces for greening.Green walls offer the prospect of greening spaces and surfaces without requiring large areas.Green walls can larg...Mitigation of urban air pollution has been constrained by the availability of urban spaces for greening.Green walls offer the prospect of greening spaces and surfaces without requiring large areas.Green walls can largely be divided into green facades where the aboveground parts of plants rooted in soil and pots grow directly on,and living walls holding bags,planter tiles,trays and vessels containing substrates in which plants are grown.Green facades and living walls can be continuous or modular with repeating units that can be assembled for extension.This review aims to present the effectiveness of green walls in removing different types of air pollutants in indoor and outdoor environments.It examined more than 45 peer-reviewed recently published scholarly articles to achieve the aim.It highlights that most of the studies on green walls focus on particulate matter removal and green walls could effectively remove particulate matter though the effectiveness varies with plant types,air humidity,rainfall and its intensity,leaf area index and contact angle,green wall surface coverage ratio,as well as the height of green walls.Increasing the height of green walls and optimizing their distance from roadsides could promote the deposition of particulate matter.Washing off could regenerate plant surfaces for capturing pollutants.Green walls are also effective in removing NO2,O3,SO2 and CO.Indoor active living walls,when properly designed,could have air purifying performance comparable to a HVAC system.The performance of green walls could be optimized through polycultures,selection of plants,surface coverage and height,and air inflow.展开更多
基金Supported by Program for Changjiang Scholars and Innovative Research Team in University,Ministry of Education of China(PCSIRT)
文摘DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.
文摘Advancement of the information society has proceeded with the development of information and communication technology, and a demand on a data center has increased. In such a situation, the number of servers is increasing in a data center. Thus, the heat density in a data center is much higher than that of usual offices. And typically, almost 40% of the total power consumption is used for cooling servers in a data center. Thus, cooling effectiveness is one of the most important factors in evaluating the value of the data center. The data center taken up in this paper is located in Ishikari, where is a cold district in Japan. Using the cool outdoor air for cooling servers helps us to cut the power consumption for cooling. This paper first assesses the efficiency of Ishikari data center measuring the temperature of seven parts in a building where the cooling air flowing. Second, this paper describes the most efficient method for the operation and estimates 1.11 of PUE (power usage effectiveness).
基金Funded by Beijing Higher Education Young Elite Teacher Project(No.YETP0371)National Key Technologies R&D Program of China(No.2012BAJ02B02)
文摘The paper presents a simple model for outdoor air contaminant transmission into occupied rooms. In the model, several factors such as filtration, ventilation, deposition, re-emission, outdoor concentration and indoor sources are included. The model results show that the air exchange rate plays an important role in the transmission of outdoor contaminants into the indoor environment. The model shows that increasing the value of the filtration efficiency decreases the mass concentration of indoor particles. In addition, if outdoor aerosol particles have a periodic behaviour, indoor aerosol particles also behave periodically but smoother. Indoor sources are found to be able to increase indoor concentrations greatly and continuously.
文摘Mitigation of urban air pollution has been constrained by the availability of urban spaces for greening.Green walls offer the prospect of greening spaces and surfaces without requiring large areas.Green walls can largely be divided into green facades where the aboveground parts of plants rooted in soil and pots grow directly on,and living walls holding bags,planter tiles,trays and vessels containing substrates in which plants are grown.Green facades and living walls can be continuous or modular with repeating units that can be assembled for extension.This review aims to present the effectiveness of green walls in removing different types of air pollutants in indoor and outdoor environments.It examined more than 45 peer-reviewed recently published scholarly articles to achieve the aim.It highlights that most of the studies on green walls focus on particulate matter removal and green walls could effectively remove particulate matter though the effectiveness varies with plant types,air humidity,rainfall and its intensity,leaf area index and contact angle,green wall surface coverage ratio,as well as the height of green walls.Increasing the height of green walls and optimizing their distance from roadsides could promote the deposition of particulate matter.Washing off could regenerate plant surfaces for capturing pollutants.Green walls are also effective in removing NO2,O3,SO2 and CO.Indoor active living walls,when properly designed,could have air purifying performance comparable to a HVAC system.The performance of green walls could be optimized through polycultures,selection of plants,surface coverage and height,and air inflow.