Central air-conditioning systems predominantly operate under partial load conditions.The optimization of a differential pressure setpoint in the chilled water system of a central air-conditioning system leads to a mor...Central air-conditioning systems predominantly operate under partial load conditions.The optimization of a differential pressure setpoint in the chilled water system of a central air-conditioning system leads to a more energy-efficient operation.Determining the differential pressure adjustment value based on the terminal user's real-time demand is one of the critical issues to be addressed during the optimal control process.Furthermore,the online application of the differential pressure setpoint optimization method needs to be considered,along with the stability of the system.This paper proposes a variable differential pressure reset method with an adaptive adjustment algorithm based on the Mamdani fuzzy model.The proposed method was compared with differential pressure reset methods with reference to the chilled water differential temperature,outdoor temperature,and linear model based on the adjustment algorithm.The energy-saving potential,temperature control effect,and avoidance of the most unfavorable thermodynamic loop effects of the four methods were investigated experimentally.The results indicated that,while satisfying the terminal user's energy supply demand and ensuring the avoidance of the most unfavorable thermodynamic loop,the proposed adaptive adjustment algorithm also decreased the differential pressure setpoint value by 25.1%—59.1%and achieved energy savings of 10.6%-45.0%.By monitoring the valve position and supply air temperature of each terminal user,the proposed method exhibited suitable online adaptability and could be flexibly applied to buildings with random load changes.展开更多
工业过程中大量使用的变频器(variable frequency drive,VFD)在采用传统交流供电时易受到电压暂降影响,传统治理方式存在检测延时、控制复杂等问题。为此,该文从敏感负荷变频器在电网扰动工况下的供电需求量化出发,围绕供电拓扑设计、DC...工业过程中大量使用的变频器(variable frequency drive,VFD)在采用传统交流供电时易受到电压暂降影响,传统治理方式存在检测延时、控制复杂等问题。为此,该文从敏感负荷变频器在电网扰动工况下的供电需求量化出发,围绕供电拓扑设计、DC/DC变换器的控制策略及储能单元容量配置等方面,构建一种实用化工业用交-直流级联供电方案。该文利用电压暂降过程中直流供电回路与敏感负荷间的压差自感应控制,实现交-直流供电回路无扰动切换,提高电压暂降治理响应的快速性;采用两相交错并联DC/DC变换器接入集中式储能,减少储能系统纹波系数,并给出两相均流控制方法。最后,通过Matlab/Simulink中的建模仿真与样机的实验测试,验证所提方案能够在交流系统发生不同严重程度电压暂降过程中为各类敏感负荷提供稳定的连续供电,为解决工业敏感用户高品质供电问题提供可实用的新思路。展开更多
基金support provided by the National Key Research and Development Project of China(No.2017YFC0704100,under the title New Generation Intelligent Building Platform Techniques)Liaoning Natural Science Foundation Guidance Plan(No.20180551057)+1 种基金Dalian High-level Talent Innovation Support Program(Youth Technology Star)(No.2017RQ099)Fundamental Research Funds for the Central Universities(No.DUT20JC47)。
文摘Central air-conditioning systems predominantly operate under partial load conditions.The optimization of a differential pressure setpoint in the chilled water system of a central air-conditioning system leads to a more energy-efficient operation.Determining the differential pressure adjustment value based on the terminal user's real-time demand is one of the critical issues to be addressed during the optimal control process.Furthermore,the online application of the differential pressure setpoint optimization method needs to be considered,along with the stability of the system.This paper proposes a variable differential pressure reset method with an adaptive adjustment algorithm based on the Mamdani fuzzy model.The proposed method was compared with differential pressure reset methods with reference to the chilled water differential temperature,outdoor temperature,and linear model based on the adjustment algorithm.The energy-saving potential,temperature control effect,and avoidance of the most unfavorable thermodynamic loop effects of the four methods were investigated experimentally.The results indicated that,while satisfying the terminal user's energy supply demand and ensuring the avoidance of the most unfavorable thermodynamic loop,the proposed adaptive adjustment algorithm also decreased the differential pressure setpoint value by 25.1%—59.1%and achieved energy savings of 10.6%-45.0%.By monitoring the valve position and supply air temperature of each terminal user,the proposed method exhibited suitable online adaptability and could be flexibly applied to buildings with random load changes.
文摘工业过程中大量使用的变频器(variable frequency drive,VFD)在采用传统交流供电时易受到电压暂降影响,传统治理方式存在检测延时、控制复杂等问题。为此,该文从敏感负荷变频器在电网扰动工况下的供电需求量化出发,围绕供电拓扑设计、DC/DC变换器的控制策略及储能单元容量配置等方面,构建一种实用化工业用交-直流级联供电方案。该文利用电压暂降过程中直流供电回路与敏感负荷间的压差自感应控制,实现交-直流供电回路无扰动切换,提高电压暂降治理响应的快速性;采用两相交错并联DC/DC变换器接入集中式储能,减少储能系统纹波系数,并给出两相均流控制方法。最后,通过Matlab/Simulink中的建模仿真与样机的实验测试,验证所提方案能够在交流系统发生不同严重程度电压暂降过程中为各类敏感负荷提供稳定的连续供电,为解决工业敏感用户高品质供电问题提供可实用的新思路。